Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = panelized light frame roof

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
29 pages, 16997 KB  
Article
Novel Apex Connection for Light Wood Frame Panelized Roof
by Md Saiful Islam, Ying Hei Chui and Zengtao Chen
Materials 2022, 15(21), 7457; https://doi.org/10.3390/ma15217457 - 24 Oct 2022
Cited by 4 | Viewed by 2892
Abstract
Panelized fabrication of light-frame wood buildings has higher productivity than the traditional stick-built method. However, the roof production process is not very efficient due to the structural system and construction method. This study proposes a novel apex connection that allows for a folding [...] Read more.
Panelized fabrication of light-frame wood buildings has higher productivity than the traditional stick-built method. However, the roof production process is not very efficient due to the structural system and construction method. This study proposes a novel apex connection that allows for a folding mechanism in a panelized light wood frame roof system. Proof of concept of the proposed connection assembly is presented by a 3D printout of the developed connection. Following the steel design code and timber code, the initial estimation of different parameters, such as the pinhole diameter and number screws, were established. A detailed finite element analysis (FEA) was performed to determine the connection strength requirement for different load case scenarios. The results of the FEA and 3D printout of the assembly show that the proposed connection can provide the required folding mechanism before roof installation and can withstand the load in the unfolding state at service. Full article
(This article belongs to the Special Issue Wood-Based Materials in Building)
Show Figures

Figure 1

19 pages, 6726 KB  
Article
Performance of a Mid-Size Net-Zero Energy Solar House
by Hessam Taherian and Robert W. Peters
Appl. Sci. 2022, 12(6), 3005; https://doi.org/10.3390/app12063005 - 15 Mar 2022
Cited by 2 | Viewed by 2718
Abstract
The University of Alabama at Birmingham (UAB) was one of 16 collegiate teams from around the world that participated in the U.S. Department of Energy Solar Decathlon 2017 competition. An interdisciplinary team of students from across the university was engaged in a 2-year [...] Read more.
The University of Alabama at Birmingham (UAB) was one of 16 collegiate teams from around the world that participated in the U.S. Department of Energy Solar Decathlon 2017 competition. An interdisciplinary team of students from across the university was engaged in a 2-year long process to design and build a house that is powered completely by solar power. The house was equipped to run all the typical appliances of an average modern house at similar levels on a conventional power grid. The net-zero house was built and tested on the UAB campus. Considering Birmingham’s weather, a safe room was built to ensure the safety of occupants during events of extreme weather, such as a tornado. A ductless HVAC unit consisting of an inverter-type 3-speed outdoor unit supplied refrigerant to four high-wall indoor units providing the primary source of space conditioning. To achieve a model of efficiency and cost effectiveness, the house incorporated a heavily insulated envelope and precise glazing protection. The roof, floor framing and walls had R-30 batt and foam insulation. With a design informed by southern vernacular language, the building is oriented to maximize solar access and to use roof planes for shading the majority of the year. Peak power generation of the panels was recorded at 9.6 kW. The home has a centralized energy management system that can provide access to energy consumption data and allow control of lighting, appliances, and plug loads remotely. Energy modeling showed that the annual electricity consumption for heating and cooling with variation in wall types were 8470 to 11,661 kWh. For the month of October, it was calculated varying from 683 to 763 kWh, with varying air changes per hour from 0 to 1.5. Full article
Show Figures

Figure 1

Back to TopTop