Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = optical glucometer

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
9 pages, 1925 KB  
Article
Validation of the Application of Solid Contact Ion-Selective Electrode for Off-Body Sweat Ion Monitoring
by Huixin Liu, Zhen Gu, Yuan Liu, Xinxin Xiao and Guangli Xiu
Biosensors 2022, 12(4), 229; https://doi.org/10.3390/bios12040229 - 9 Apr 2022
Cited by 4 | Viewed by 4502
Abstract
The solid contact ion-selective electrode (ISE) is a promising skin-interfaced monitoring system for sweat ions. Despite a growing number of on-body usages of ISE with fancy new materials and device fabrications, there are very few reports attempting to validate ISE results with a [...] Read more.
The solid contact ion-selective electrode (ISE) is a promising skin-interfaced monitoring system for sweat ions. Despite a growing number of on-body usages of ISE with fancy new materials and device fabrications, there are very few reports attempting to validate ISE results with a gold standard technique. For this purpose, this work uses inductively coupled plasma-optical emission spectrometry (ICP-OES) as a reference technique to conduct a direct evaluation of the sweat sodium and potassium ion levels obtained by ISE in an off-body approach. Eight healthy male subjects were recruited to collect exercise-induced sweat. It was found that sweat sodium and potassium ions present a rather wide concentration range. The sweat sodium concentration did not vary greatly in an exercise period of half an hour, while the sweat potassium concentration typically decreased with exercise. Mineral drink intake had no clear impact on the sweat sodium level, but increased the sweat potassium level. A paired t-test and mean absolute relative difference (MARD) analysis, a method typically used for evaluating the performance of glucometers, was employed to compare the results of ISE and ICP-OES. The statistical analysis validated the feasibility of ISE for measuring sweat ions, although better accuracy is required. Our data suggests that overweight subjects are likely to possess a higher sweat sodium level. Full article
(This article belongs to the Section Biosensors and Healthcare)
Show Figures

Figure 1

11 pages, 1970 KB  
Article
Noncontact Optical Measurement of Aqueous Humor Glucose Levels and Correlation with Serum Glucose Levels in Rabbit
by Yih-Shiou Hwang, Eugene Yu-Chuan Kang, Chia-Rui Shen, Wei-Hsin Hong and Wei-Chi Wu
Biosensors 2021, 11(10), 387; https://doi.org/10.3390/bios11100387 - 13 Oct 2021
Cited by 6 | Viewed by 4091
Abstract
The noninvasive measurement of serum glucose levels has been investigated for the monitoring of blood sugar control in diabetes. In our study, we aimed to develop a novel noncontact glucometer (NCGM) utilizing an optical approach to measure the intraocular aqueous humor glucose levels [...] Read more.
The noninvasive measurement of serum glucose levels has been investigated for the monitoring of blood sugar control in diabetes. In our study, we aimed to develop a novel noncontact glucometer (NCGM) utilizing an optical approach to measure the intraocular aqueous humor glucose levels in the anterior chamber of rabbit eyes. The NCGM consists of a hybrid optical system that simultaneously measures near-infrared absorption and the polarized rotatory distribution of glucose molecules in the aqueous humor. In vitro optical measurements demonstrated that NCGM measurements had high precision and repeatability for different glucose levels, including 50 mg/dL (14.36%), 100 mg/dL (−4.05%), 200 mg/dL (−5.99%), 300 mg/dL (4.86%), 400 mg/dL (−2.84%), 500 mg/dL (−0.11%), and 600 mg/dL (4.48%). In the rabbit experiments, we found a high correlation between aqueous glucose levels and serum glucose levels, with a mean difference of 8 mg/dL. According to the testing results, the in vivo NCGM measurement of aqueous humor glucose levels also displayed a high correlation with serum glucose levels, with a mean difference of 29.2 mg/dL. In conclusion, aqueous humor glucose levels were accurately measured using the NCGM, and the results correlated with serum glucose levels. Full article
(This article belongs to the Special Issue Glucose Sensors—an Essential Tool in Diabetes Management)
Show Figures

Figure 1

12 pages, 2858 KB  
Article
Effective Diagnosis of Foot-And-Mouth Disease Virus (FMDV) Serotypes O and A Based on Optical and Electrochemical Dual-Modal Detection
by Yun-Jung Hwang, Kyung-Kwan Lee, Jong-Won Kim, Kwang-Hyo Chung, Sang-Jick Kim, Wan-Soo Yun and Chang-Soo Lee
Biomolecules 2021, 11(6), 841; https://doi.org/10.3390/biom11060841 - 5 Jun 2021
Cited by 13 | Viewed by 5394
Abstract
Foot-and-mouth disease virus (FMDV) is a highly contagious disease that affects cloven-hoofed animals. The traditional diagnostic methods for FMDV have several drawbacks such as cross-reactivity, low sensitivity, and low selectivity. To overcome these drawbacks, we present an optical and electrochemical dual-modal approach for [...] Read more.
Foot-and-mouth disease virus (FMDV) is a highly contagious disease that affects cloven-hoofed animals. The traditional diagnostic methods for FMDV have several drawbacks such as cross-reactivity, low sensitivity, and low selectivity. To overcome these drawbacks, we present an optical and electrochemical dual-modal approach for the specific detection of FMDV serotypes O and A by utilizing a magnetic nanoparticle labeling technique with resorufin β-d-glucopyranoside (res-β-glc) and β-glucosidase (β-glc), without the use of typical lateral flow assay or polymerase chain reaction. FMDV serotypes O and A were reacted with pan-FMDV antibodies that recognize all seven FMDV serotypes (O, A, C, Asia 1, SAT 1, SAT 2, and SAT 3). The antigen–antibody complex was then immobilized on magnetic nanoparticles and reacted with β-glc-conjugated FMDV type O or type A antibodies. Subsequently, the addition of res-β-glc resulted in the release of fluorescent resorufin and glucose owing to catalytic hydrolysis by β-glc. The detection limit of fluorescent signals using a fluorescence spectrophotometer was estimated to be log(6.7) and log(5.9) copies/mL for FMDV type O and A, respectively, while that of electrochemical signals using a glucometer was estimated to be log(6.9) and log(6.1) copies/mL for FMDV type O and A, respectively. Compared with a commercially available lateral flow assay diagnostic kit for immunochromatographic detection of FMDV type O and A, this dual-modal detection platform offers approximately four-fold greater sensitivity. This highly sensitive and accurate dual-modal detection method can be used for effective disease diagnosis and treatment, and will find application in the early-stage diagnosis of viral diseases and next-generation diagnostic platforms. Full article
Show Figures

Figure 1

20 pages, 5263 KB  
Article
Blood Glucose Level Regression for Smartphone PPG Signals Using Machine Learning
by Tanvir Tazul Islam, Md Sajid Ahmed, Md Hassanuzzaman, Syed Athar Bin Amir and Tanzilur Rahman
Appl. Sci. 2021, 11(2), 618; https://doi.org/10.3390/app11020618 - 10 Jan 2021
Cited by 57 | Viewed by 18522
Abstract
Diabetes is a chronic illness that affects millions of people worldwide and requires regular monitoring of a patient’s blood glucose level. Currently, blood glucose is monitored by a minimally invasive process where a small droplet of blood is extracted and passed to a [...] Read more.
Diabetes is a chronic illness that affects millions of people worldwide and requires regular monitoring of a patient’s blood glucose level. Currently, blood glucose is monitored by a minimally invasive process where a small droplet of blood is extracted and passed to a glucometer—however, this process is uncomfortable for the patient. In this paper, a smartphone video-based noninvasive technique is proposed for the quantitative estimation of glucose levels in the blood. The videos are collected steadily from the tip of the subject’s finger using smartphone cameras and subsequently converted into a Photoplethysmography (PPG) signal. A Gaussian filter is applied on top of the Asymmetric Least Square (ALS) method to remove high-frequency noise, optical noise, and motion interference from the raw PPG signal. These preprocessed signals are then used for extracting signal features such as systolic and diastolic peaks, the time differences between consecutive peaks (DelT), first derivative, and second derivative peaks. Finally, the features are fed into Principal Component Regression (PCR), Partial Least Square Regression (PLS), Support Vector Regression (SVR) and Random Forest Regression (RFR) models for the prediction of glucose level. Out of the four statistical learning techniques used, the PLS model, when applied to an unbiased dataset, has the lowest standard error of prediction (SEP) at 17.02 mg/dL. Full article
Show Figures

Figure 1

10 pages, 3391 KB  
Article
A Plasmonic Fiber Based Glucometer and Its Temperature Dependence
by Jisoo Kim, Changjin Son, Sunjak Choi, Won Jung Yoon and Heongkyu Ju
Micromachines 2018, 9(10), 506; https://doi.org/10.3390/mi9100506 - 5 Oct 2018
Cited by 14 | Viewed by 3210
Abstract
We present the plasmonic fiber based optical glucometer. A thin gold layer is coated on clad-free core of multimode optical fiber along 3 cm length to excite surface plasmons at 632.8 nm wavelength. Glucose oxidase is immobilized on the metal surface for glucose [...] Read more.
We present the plasmonic fiber based optical glucometer. A thin gold layer is coated on clad-free core of multimode optical fiber along 3 cm length to excite surface plasmons at 632.8 nm wavelength. Glucose oxidase is immobilized on the metal surface for glucose sensing. The effective surface refractive index increases by gluconic acid and hydrogen peroxide that are generated upon glucose injection, leading to plasmonic condition change with a consequence of optical power change at the fiber output. We obtain limit of detection of glucose concentration of 6.75 mg/dL, indicating higher sensitivity than the wavelength interrogating SPR glucometer that uses a spectrometer of 1nm spectral resolution. The coefficient of variation is 8.6% at a glucose concentration of 80 mg/dL at room temperature. We also examine the effects of ambient temperature variations from −10 °C to 40 °C on the performance of the presented sensor and compared them with those on commercially available glucometers that are based on enzyme electrodes. We find that the presented fiber sensor produced standard deviation of 12.1 mg/dL at a glucose concentration of 80 mg/dL under such varying temperature, which is, even without additional temperature correction function, comparable to the commercialized ones. Full article
(This article belongs to the Special Issue NANO KOREA 2018)
Show Figures

Figure 1

Back to TopTop