Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = malaria pan rapid diagnostic strip

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 5698 KiB  
Article
Evaluation of the Performance of Rapid Diagnostic Tests for Malaria Diagnosis and Mapping of Different Plasmodium Species in Mali
by Pascal Dembélé, Mady Cissoko, Adama Zan Diarra, Lassana Doumbia, Aïssata Koné, Mahamadou H. Magassa, Maissane Mehadji, Mahamadou A. Thera and Stéphane Ranque
Int. J. Environ. Res. Public Health 2024, 21(2), 228; https://doi.org/10.3390/ijerph21020228 - 15 Feb 2024
Cited by 4 | Viewed by 3399
Abstract
Background: The first-line diagnosis of malaria in Mali is based on the use of rapid diagnostic tests (RDT) that detect the Histidin Rich Protein 2 (HRP2) antigen specific to Plasmodium falciparum. Our study, based on a real-time polymerase chain reaction (qPCR) gold [...] Read more.
Background: The first-line diagnosis of malaria in Mali is based on the use of rapid diagnostic tests (RDT) that detect the Histidin Rich Protein 2 (HRP2) antigen specific to Plasmodium falciparum. Our study, based on a real-time polymerase chain reaction (qPCR) gold standard, aimed to describe the distribution of the Plasmodium species in each administrative region of Mali and to assess the performance of RDTs. Methods: We randomly selected 150 malaria-negative and up to 30 malaria-positive RDTs in 41 sites distributed in 9 regions of Mali. DNA extracted from the RDT nitrocellulose strip was assayed with a pan-Plasmodium qPCR. Positive samples were then analyzed with P. falciparum-, P. malariae-, P. vivax-, or P. ovale-specific qPCRs. Results: Of the 1496 RDTs, 258 (18.6%) were positive for Plasmodium spp., of which 96.9% were P. falciparum. The P. vivax prevalence reached 21.1% in the north. RDT displayed acceptable diagnostic indices; the lower CI95% bounds of Youden indices were all ≥0.50, except in the north (Youden index 0.66 (95% CI [0.44–0.82]) and 0.63 (95% CI [0.33–0.83]. Conclusions: Overall, RDT diagnostic indices are adequate for the biological diagnosis of malaria in Mali. We recommend the use of RDTs detecting P. vivax-specific antigens in the north. Full article
Show Figures

Figure 1

12 pages, 7485 KiB  
Technical Note
Optical Density Optimization of Malaria Pan Rapid Diagnostic Test Strips for Improved Test Zone Band Intensity
by Prince Manta, Rupak Nagraik, Avinash Sharma, Akshay Kumar, Pritt Verma, Shravan Kumar Paswan, Dmitry O. Bokov, Juber Dastagir Shaikh, Roopvir Kaur, Ana Francesca Vommaro Leite, Silas Jose Braz Filho, Nimisha Shiwalkar, Purnadeo Persaud and Deepak N. Kapoor
Diagnostics 2020, 10(11), 880; https://doi.org/10.3390/diagnostics10110880 - 29 Oct 2020
Cited by 11 | Viewed by 5590
Abstract
For the last few decades, the immunochromatographic assay has been used for the rapid detection of biological markers in infectious diseases in humans and animals The assay, also known as lateral flow assay, is utilized for the detection of antigen or antibody in [...] Read more.
For the last few decades, the immunochromatographic assay has been used for the rapid detection of biological markers in infectious diseases in humans and animals The assay, also known as lateral flow assay, is utilized for the detection of antigen or antibody in human infectious diseases. There are a series of steps involved in the development of these immuno-chromatographic test kits, from gold nano colloids preparation to nitrocellulose membrane coating (NCM). These tests are mostly used for qualitative assays by a visual interpretation of results. For the interpretation of the results, the color intensity of the test zone is therefore very significant. Herein, the study was performed on a malaria antigen test kit. Several studies have reported the use of gold nanoparticles (AuNPs) with varying diameters and its binding with various concentrations of protein in order to optimize tests. However, none of these studies have reported how to fix (improve) test zone band intensity (color), if different sized AuNPs were synthesized during a reaction and when conjugated equally with same amount of protein. Herein, different AuNPs with average diameter ranging from 10 nm to 50 nm were prepared and conjugated equally with protein concentration of 150 µg/mL with KD = 1.0 × 10−3. Afterwards, the developed kits’ test zone band intensity for all different sizes AuNPs was fixed to the same band level (high) by utilization of an ultraviolet-visible spectrophotometer. The study found that the same optical density (OD) has the same test zone band intensity irrespective of AuNP size. This study also illustrates the use of absorption maxima (λ max) techniques to characterize AuNPs and to prevent wastage of protein while developing immunochromatographic test kits. Full article
(This article belongs to the Special Issue Point-of-Care Detection Devices for Healthcare)
Show Figures

Graphical abstract

Back to TopTop