Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = impermeable partition wall

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 9128 KiB  
Article
Determining Moisture Condition of External Thermal Insulation Composite System (ETICS) of an Existing Building
by Paweł Krause, Iwona Pokorska-Silva and Łukasz Kosobucki
Materials 2025, 18(3), 614; https://doi.org/10.3390/ma18030614 - 29 Jan 2025
Viewed by 932
Abstract
ETICS is a popular external wall insulation system, which is not without possible defects and damages. A frequent cause, direct or indirect, of damage to buildings is the impact of water (moisture). This article presents, among others, the results of tests of the [...] Read more.
ETICS is a popular external wall insulation system, which is not without possible defects and damages. A frequent cause, direct or indirect, of damage to buildings is the impact of water (moisture). This article presents, among others, the results of tests of the moisture content of ETICS layers, the water absorption and capillary absorption of the render by means of the Karsten tube method, numerical thermo-moisture simulations, and tests of interlayer adhesion, in sample residential buildings. Mass moisture content testing of the wall substrate showed acceptable moisture levels (1–4%m) within masonry walls made of silicate blocks, as well as locally elevated moisture levels (4–8%m) in the case of reinforced concrete walls. Moisture testing of the insulation samples showed a predominantly dry condition, and testing of the reinforcement layer showed an acceptable level of moisture. Severe moisture was found in the sample taken in the ground-floor zone at the interface between mineral wool and EPS-P insulation underneath the reinforced layer. Capillary water absorption tests helped classify silicone render as an impermeable and surface hydrophobic coating. Tests of the water absorption of the facade plaster showed that the value declared by the manufacturer (<0.5 kg/m2) was mostly met (not in the ground-floor zone). The simulation calculations gave information that there was no continuous increase in condensation during the assumed analysis time (the influence of interstitial condensation on the observed anomalies was excluded). The tests carried out indicated the occurrence of numerous errors in the implementation of insulation works affecting the moisture content and durability of external partitions. Full article
(This article belongs to the Section Construction and Building Materials)
Show Figures

Figure 1

15 pages, 2904 KiB  
Article
Comparative Study on the Hydraulic Characteristics of Nature-Like Fishways
by Tiegang Zheng, Zhipan Niu, Shuangke Sun, Jiayue Shi, Haitao Liu and Guangning Li
Water 2020, 12(4), 955; https://doi.org/10.3390/w12040955 - 27 Mar 2020
Cited by 6 | Viewed by 3272
Abstract
Due to the complex structure and the multiformity of boulder arrangements, there is currently no perfect design criterion for nature-like fishways. This paper proposes four types of nature-like fishways arranged with an impermeable partition wall (IPW), a semi-permeable partition wall (SPPW) or a [...] Read more.
Due to the complex structure and the multiformity of boulder arrangements, there is currently no perfect design criterion for nature-like fishways. This paper proposes four types of nature-like fishways arranged with an impermeable partition wall (IPW), a semi-permeable partition wall (SPPW) or a fully permeable partition wall (FPPW). The hydraulic characteristics of these fishways were investigated experimentally. The results show that the discharge of the fishway arranged with a FPPW was almost twice that of an IPW fishway, and the discharge of a SPPW fishway was between the two extremes. The mean flow velocity of the FPPW fishway was larger than that of the other schemes. For the fishway arranged with an IPW, the flow information was basically consistent with that of the engineered technical fishway. In the FPPW or SPPW fishway, there was more abundant flow information and no obvious recirculation zones in the fishway pool, and these conditions are suitable for migratory fish moving up- and downstream. Notably, for the fishway arranged with two fish passages, two mainstreams were formed in the pool, which divided the flow pattern of the pool into three flow regions. A weak recirculation area was formed in the low-velocity region, which facilitates swimming for migratory fish. According to this comprehensive comparative study, the SPPW fishway with two fish passages had low discharge, abundant flow information and favorable fish migration characteristics; thus, it is the optimal fishway scheme among those studied in this paper. Full article
(This article belongs to the Section Hydraulics and Hydrodynamics)
Show Figures

Figure 1

Back to TopTop