Search Results (2)

Search Parameters:
Keywords = flat-detector computed tomography (FD-CT)

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 1017 KiB  
Article
Accuracy of Dose-Saving Artificial-Intelligence-Based 3D Angiography (3DA) for Grading of Intracranial Artery Stenoses: Preliminary Findings
by Stefan Lang, Philip Hoelter, Manuel Alexander Schmidt, Anne Mrochen, Joji Kuramatsu, Christian Kaethner, Philipp Roser, Markus Kowarschik and Arnd Doerfler
Diagnostics 2023, 13(4), 712; https://doi.org/10.3390/diagnostics13040712 - 14 Feb 2023
Cited by 5 | Viewed by 2971
Abstract
Background and purpose: Based on artificial intelligence (AI), 3D angiography (3DA) is a novel postprocessing algorithm for “DSA-like” 3D imaging of cerebral vasculature. Because 3DA requires neither mask runs nor digital subtraction as the current standard 3D-DSA does, it has the potential to [...] Read more.
Background and purpose: Based on artificial intelligence (AI), 3D angiography (3DA) is a novel postprocessing algorithm for “DSA-like” 3D imaging of cerebral vasculature. Because 3DA requires neither mask runs nor digital subtraction as the current standard 3D-DSA does, it has the potential to cut the patient dose by 50%. The object was to evaluate 3DA’s diagnostic value for visualization of intracranial artery stenoses (IAS) compared to 3D-DSA. Materials and methods: 3D-DSA datasets of IAS (nIAS = 10) were postprocessed using conventional and prototype software (Siemens Healthineers AG, Erlangen, Germany). Matching reconstructions were assessed by two experienced neuroradiologists in consensus reading, considering image quality (IQ), vessel diameters (VD1/2), vessel-geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of IAS (e.g., location, visual IAS grading [low-/medium-/high-grade] and intra-/poststenotic diameters [dintra-/poststenotic in mm]). Using the NASCET criteria, the percentual degree of luminal restriction was calculated. Results: In total, 20 angiographic 3D volumes (n3DA = 10; n3D-DSA = 10) were successfully reconstructed with equivalent IQ. Assessment of the vessel geometry in 3DA datasets did not differ significantly from 3D-DSA (VD1: r = 0.994, p = 0.0001; VD2:r = 0.994, p = 0.0001; VGI: r = 0.899, p = 0.0001). Qualitative analysis of IAS location (3DA/3D-DSA:nICA/C4 = 1, nICA/C7 = 1, nMCA/M1 = 4, nVA/V4 = 2, nBA = 2) and the visual IAS grading (3DA/3D-DSA:nlow-grade = 3, nmedium-grade = 5, nhigh-grade = 2) revealed identical results for 3DA and 3D-DSA, respectively. Quantitative IAS assessment showed a strong correlation regarding intra-/poststenotic diameters (rdintrastenotic = 0.995, pdintrastenotic = 0.0001; rdpoststenotic = 0.995, pdpoststenotic = 0.0001) and the percentual degree of luminal restriction (rNASCET 3DA = 0.981; pNASCET 3DA = 0.0001). Conclusions: The AI-based 3DA is a resilient algorithm for the visualization of IAS and shows comparable results to 3D-DSA. Hence, 3DA is a promising new method that allows a considerable patient-dose reduction, and its clinical implementation would be highly desirable. Full article
(This article belongs to the Special Issue Advancements in Neuroimaging)
Show Figures

Figure 1

10 pages, 7872 KiB  
Article
Clinical Comparison of FD-CT and MS-CT in Aneurysmal Subarachnoid Haemorrhage: A Single Center Experience
by Felix Eisenhut, Cornelius Heidelbach, Elisabeth Heynold, Michael Manhart, Tobias Struffert, Sebastian Brandner, Arnd Doerfler and Stefan Lang
Diagnostics 2022, 12(10), 2443; https://doi.org/10.3390/diagnostics12102443 - 9 Oct 2022
Viewed by 2366
Abstract
Single-center comparison of postinterventional multislice computed tomography (MS-CT) and flat-detector computed tomography (FD-CT) in patients with subarachnoid haemorrhage (SAH) and endovascularly treated cerebral aneurysms with a focus on detection of posttherapeutical complications. Patients with endovascularly treated aneurysmal SAH undergoing both MS-CT and FD-CT [...] Read more.
Single-center comparison of postinterventional multislice computed tomography (MS-CT) and flat-detector computed tomography (FD-CT) in patients with subarachnoid haemorrhage (SAH) and endovascularly treated cerebral aneurysms with a focus on detection of posttherapeutical complications. Patients with endovascularly treated aneurysmal SAH undergoing both MS-CT and FD-CT within 24 h after intervention were included. Datasets were compared regarding image quality (IQ) as well as qualitative (detection of SAH, intracerebral haemorrhage [ICH], intraventricular haemorrhage [IVH], external ventricular drain [EVD] position, acute obstructive hydrocephalus [AOH]) and quantitative (cella media distance [CMD], modified Graeb score [GS]) parameters. 410 patients with endovascularly treated aneurysmal SAH were included. IQ was equal between MS-CT and FD-CT. FD-CT allowed equal detection of SAH and ICH in comparison to MS-CT. FD-CT allowed excellent detection of IVH and delineation of EVD position with strong agreement to MS-CT findings. FD-CT allowed equal detection of AOH in comparison to MS-CT. There was no significant difference of CMD and GS between FD-CT and MS-CT. Postinterventional FD-CT yields equivalent diagnostic value in patients with endovascular treated SAH as MS-CT. Enabling reliable detection of SAH-associated complications within the angiosuite, FD-CT might be an efficient and safe imaging modality in these clinical emergencies. Full article
(This article belongs to the Section Medical Imaging and Theranostics)