Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = cold arm width

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2584 KB  
Article
Measurement of Coherence Time in Cold Atom-Generated Tunable Photon Wave Packets Using an Unbalanced Fiber Interferometer
by Ya Li, Wanru Wang, Qizhou Wu, Youxing Chen, Can Sun, Hai Wang and Weizhe Qiao
Photonics 2025, 12(5), 415; https://doi.org/10.3390/photonics12050415 - 25 Apr 2025
Viewed by 1087
Abstract
In the realm of quantum communication and photonic technologies, the extension of coherence time for photon wave packets is essential for improving system efficacy. This research introduces a methodology for measuring coherence time utilizing an unbalanced fiber interferometer, specifically designed for tunable pulse-width [...] Read more.
In the realm of quantum communication and photonic technologies, the extension of coherence time for photon wave packets is essential for improving system efficacy. This research introduces a methodology for measuring coherence time utilizing an unbalanced fiber interferometer, specifically designed for tunable pulse-width photon wave packets produced by cold atoms. By synchronously generating write pulses, signal light, and frequency-locking light from a single laser source, the study effectively mitigated frequency discrepancies that typically arise from the use of multiple light sources. The implementation of frequency-resolved photon counting under phase-locked conditions was accomplished through the application of polarization filtering and cascaded filtering techniques. The experimental results indicated that the periodicity of frequency shifts in interference fringe patterns diminishes as the differences in delay arm lengths increase, while fluctuations in fiber length and high-frequency laser jitter adversely affect interference visibility. Through an analysis of the correlation between delay and photon counts, the coherence time of the write laser was determined to be 2.56 µs, whereas the Stokes photons produced through interactions with cold atoms exhibited a reduced coherence time of 1.23 µs. The findings suggest that enhancements in laser bandwidth compression and fiber phase stability could further prolong the coherence time of photon wave packets generated by cold atoms, thereby providing valuable technical support for high-fidelity quantum information processing. Full article
Show Figures

Figure 1

18 pages, 7865 KB  
Article
The Effects of Cold Arm Width and Metal Deposition on the Performance of a U-Beam Electrothermal MEMS Microgripper for Biomedical Applications
by Marija Cauchi, Ivan Grech, Bertram Mallia, Pierluigi Mollicone and Nicholas Sammut
Micromachines 2019, 10(3), 167; https://doi.org/10.3390/mi10030167 - 28 Feb 2019
Cited by 30 | Viewed by 4127
Abstract
Microelectromechanical systems (MEMS) have established themselves within various fields dominated by high-precision micromanipulation, with the most distinguished sectors being the microassembly, micromanufacturing and biomedical ones. This paper presents a horizontal electrothermally actuated ‘hot and cold arm’ microgripper design to be used for the [...] Read more.
Microelectromechanical systems (MEMS) have established themselves within various fields dominated by high-precision micromanipulation, with the most distinguished sectors being the microassembly, micromanufacturing and biomedical ones. This paper presents a horizontal electrothermally actuated ‘hot and cold arm’ microgripper design to be used for the deformability study of human red blood cells (RBCs). In this study, the width and layer composition of the cold arm are varied to investigate the effects of dimensional and material variation of the cold arm on the resulting temperature distribution, and ultimately on the achieved lateral displacement at the microgripper arm tips. The cold arm widths investigated are 14 μ m, 30 μ m, 55 μ m, 70 μ m and 100 μ m. A gold layer with a thin chromium adhesion promoter layer is deposited on the top surface of each of these cold arms to study its effect on the performance of the microgripper. The resultant ten microgripper design variants are fabricated using a commercially available MEMS fabrication technology known as a silicon-on-insulator multi-user MEMS process (SOIMUMPs)™. This process results in an overhanging 25 μ m thick single crystal silicon microgripper structure having a low aspect ratio (width:thickness) value compared to surface micromachined structures where structural thicknesses are of the order of 2 μ m. Finite element analysis was used to numerically model the microgripper structures and coupled electrothermomechanical simulations were implemented in CoventorWare ® . The numerical simulations took into account the temperature dependency of the coefficient of thermal expansion, the thermal conductivity and the electrical conductivity properties in order to achieve more reliable results. The fabricated microgrippers were actuated under atmospheric pressure and the experimental results achieved through optical microscopy studies conformed with those predicted by the numerical models. The gap opening and the temperature rise at the cell gripping zone were also compared for the different microgripper structures in this work, with the aim of identifying an optimal microgripper design for the deformability characterisation of RBCs. Full article
(This article belongs to the Special Issue 10th Anniversary of Micromachines)
Show Figures

Figure 1

9 pages, 2274 KB  
Article
Thermoelectric Mixed Thick-/Thin Film Microgenerators Based on Constantan/Silver
by Mirosław Gierczak, Joanna Prażmowska-Czajka and Andrzej Dziedzic
Materials 2018, 11(1), 115; https://doi.org/10.3390/ma11010115 - 12 Jan 2018
Cited by 26 | Viewed by 5755
Abstract
This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy) and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm [...] Read more.
This paper describes the design, manufacturing and characterization of newly developed mixed thick-/thin film thermoelectric microgenerators based on magnetron sputtered constantan (copper-nickel alloy) and screen-printed silver layers. The thermoelectric microgenerator consists of sixteen thermocouples made on a 34.2 × 27.5 × 0.25 mm3 alumina substrate. One of thermocouple arms was made of magnetron-sputtered constantan (Cu-Ni alloy), the second was a Ag-based screen-printed film. The length of each thermocouple arm was equal to 27 mm, and their width 0.3 mm. The distance between the arms was equal to 0.3 mm. In the first step, a pattern mask with thermocouples was designed and fabricated. Then, a constantan layer was magnetron sputtered over the whole substrate, and a photolithography process was used to prepare the first thermocouple arms. The second arms were screen-printed onto the substrate using a low-temperature silver paste (Heraeus C8829A or ElectroScience Laboratories ESL 599-E). To avoid oxidation of constantan, they were fired in a belt furnace in a nitrogen atmosphere at 550/450 °C peak firing temperature. Thermoelectric and electrical measurements were performed using the self-made measuring system. Two pyrometers included into the system were used for temperature measurement of hot and cold junctions. The estimated Seebeck coefficient, α was from the range 35 − 41 µV/K, whereas the total internal resistances R were between 250 and 3200 ohms, depending on magnetron sputtering time and kind of silver ink (the resistance of a single thermocouple was between 15.5 and 200 ohms). Full article
Show Figures

Figure 1

Back to TopTop