Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = barometric formula

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 5482 KB  
Article
Assessment of ZTD Derived from COSMIC Occultation Data with ECWMF, Radiosondes, and GNSS
by Naifeng Fu, Mingbo Jiang, Fenghui Li, Peng Guo, Chunping Hou, Mengjie Wu, Jianming Wu, Zhipeng Wang and Liang Kan
Sensors 2022, 22(14), 5209; https://doi.org/10.3390/s22145209 - 12 Jul 2022
Cited by 3 | Viewed by 2815
Abstract
Global Navigation Satellite System (GNSS) signals generate slant tropospheric delays when they pass through the atmosphere, which is recognized as the main source of error in many spatial geodetic applications. The zenith tropospheric delay (ZTD) derived from radio occultation data is of great [...] Read more.
Global Navigation Satellite System (GNSS) signals generate slant tropospheric delays when they pass through the atmosphere, which is recognized as the main source of error in many spatial geodetic applications. The zenith tropospheric delay (ZTD) derived from radio occultation data is of great significance to atmospheric research and meteorology and needs to be assessed in the use of precision positioning. Based on the atmPrf, sonPrf, and echPrf data from the Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC) Data Analysis and Archiving Center (CDAAC) from 1 January to 31 December 2008 and 2012, we obtained the ZTDs of the radio occultation data (occZTD) and the corresponding radiosonde (sonZTD) and ECWMF data (echZTD). The ZTDs derived from ground-based global positioning system (GPS) observations from the International GNSS Service (IGS) were corrected to the lowest tangent point height of the matched radio occultation profile by the barometric height formula (gnsZTD). The statistical results show that the absolute values of the bias between occZTD and echZTD, sonZTD, or gnsZTD are less than 5 mm, and the standard deviations are approximately 20 mm or less, indicating that occZTD had significant accuracy in the GNSS positioning model even when the local spherical symmetry assumption error was introduced when the Abel inversion algorithm was used to obtain the refractive index profile of atmPrf. The effects of the horizontal/vertical matching resolution and the variation in the station height/latitude on the biases of occZTD and gnsZTD were analyzed. The results can be used to quantify the performance of radio occultation data for tropospheric delay error correction in dynamic high-precision positioning. Full article
(This article belongs to the Special Issue Multi-GNSS Positioning in Remote Sensing Applications)
Show Figures

Figure 1

24 pages, 6134 KB  
Article
Impact of Air Density Variation on a Simulated Earth-to-Air Heat Exchanger’s Performance
by Piotr Michalak
Energies 2022, 15(9), 3215; https://doi.org/10.3390/en15093215 - 27 Apr 2022
Cited by 8 | Viewed by 3342
Abstract
Due to their simple design and reliable operation, earth-to-air heat exchangers (EAHE) are used in modern buildings to reduce ventilation heat losses. EAHE operation in atmospheric conditions results in variation in ambient air temperature and pressure affecting air density. The paper presents the [...] Read more.
Due to their simple design and reliable operation, earth-to-air heat exchangers (EAHE) are used in modern buildings to reduce ventilation heat losses. EAHE operation in atmospheric conditions results in variation in ambient air temperature and pressure affecting air density. The paper presents the study on the impact of ambient air density variation on the calculated hourly air temperature at the EAHE outlet and the resulting energy use for space heating and cooling of an exemplary residential building. The ground temperature was computed from the model given in EN 16798-5-1. Then, air density was obtained using five various methods. Energy use for space heating and cooling of the building was computed using the 5R1C thermal network model of EN ISO 13790. Depending on the chosen method and concerning the base case without EAHE, a reduction in annual heating and cooling needs was obtained from 7.5% to 8.8% in heating and from 15.3% to 19% in cooling. Annual heating and cooling gain from EAHE were 600.9 kWh and 628.3 kWh for heating and 616.9 kWh and 603.5 kWh for cooling for the Typical Meteorological Years (TMY) and International Weather for Energy Calculation (IWEC) files, respectively. Unit heating and cooling gains per heat exchanger area were from 34.9 kWh/m2 to 36.8 kWh/m2 and from −35.1 kWh/m2 to −36.3 kWh/m2. Density variation with temperature from the relevant typical Polish meteorological year at constant pressure, in comparison to the method of EN 16798-5-1, resulted in an hourly difference of that unit gain up to 4.3 W/m2 and 2.0 W/m2 for heating and cooling, respectively. The same was true inthe case of IWEC files that resulted in differences of 5.5 W/m2 and 1.1 W/m2. Full article
(This article belongs to the Special Issue Heat Transfer and Heat Recovery Systems)
Show Figures

Figure 1

21 pages, 1127 KB  
Article
Using Multiple Barometers to Detect the Floor Location of Smart Phones with Built-in Barometric Sensors for Indoor Positioning
by Hao Xia, Xiaogang Wang, Yanyou Qiao, Jun Jian and Yuanfei Chang
Sensors 2015, 15(4), 7857-7877; https://doi.org/10.3390/s150407857 - 31 Mar 2015
Cited by 92 | Viewed by 10951
Abstract
Following the popularity of smart phones and the development of mobile Internet, the demands for accurate indoor positioning have grown rapidly in recent years. Previous indoor positioning methods focused on plane locations on a floor and did not provide accurate floor positioning. In [...] Read more.
Following the popularity of smart phones and the development of mobile Internet, the demands for accurate indoor positioning have grown rapidly in recent years. Previous indoor positioning methods focused on plane locations on a floor and did not provide accurate floor positioning. In this paper, we propose a method that uses multiple barometers as references for the floor positioning of smart phones with built-in barometric sensors. Some related studies used barometric formula to investigate the altitude of mobile devices and compared the altitude with the height of the floors in a building to obtain the floor number. These studies assume that the accurate height of each floor is known, which is not always the case. They also did not consider the difference in the barometric-pressure pattern at different floors, which may lead to errors in the altitude computation. Our method does not require knowledge of the accurate heights of buildings and stories. It is robust and less sensitive to factors such as temperature and humidity and considers the difference in the barometric-pressure change trends at different floors. We performed a series of experiments to validate the effectiveness of this method. The results are encouraging. Full article
(This article belongs to the Special Issue Sensors for Indoor Mapping and Navigation)
Show Figures

Figure 1

Back to TopTop