Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = angulated screw channel

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 4122 KB  
Article
Comparison of Aesthetic, Mechanical Outcome, and Bone Loss in Angulated Screw Channels (ASCs) and Cement-Retained Implant-Supported Prosthesis: A Case-Control Study
by Edoardo Rella, Paolo De Angelis, Laura Papetti, Giovanni Damis, Giulio Gasparini, Antonio D’Addona and Paolo Francesco Manicone
Dent. J. 2024, 12(8), 233; https://doi.org/10.3390/dj12080233 - 24 Jul 2024
Cited by 2 | Viewed by 2314
Abstract
Angulated-screw channels (ASCs) allow the clinician to employ screw-retained restorations in almost all cases, as the access hole can be moved away from the vestibular portion of the crown, where it would jeopardize the final esthetic result. The objective of this study was [...] Read more.
Angulated-screw channels (ASCs) allow the clinician to employ screw-retained restorations in almost all cases, as the access hole can be moved away from the vestibular portion of the crown, where it would jeopardize the final esthetic result. The objective of this study was to compare screw-retained restorations employing ASCs with restorations cemented on angled abutments. In this study, 30 subjects, equally divided into two groups: group 1 (cemented restorations on angulated abutments) and group 2 (screw-retained restorations adopting ASCs), were treated and retrospectively compared after 2 years using the pink esthetic score (PES) and the white esthetic score (WES). All restorations were in use at the last follow-up, with a survival rate of 100%. Three mechanical complications were observed (2 chippings and 1 crown came loose), with a success rate of 93% in group 1 and 87% in group 2 (p > 0.05). No statistically significant differences were reported regarding the esthetic outcome; the marginal bone loss (MBL) showed better results for the screw-retained restorations, both at the distal aspect (group 1 = 0.98 mm ± 0.16; group 2 = 0.45 mm ± 0.06; p = 0.006) and at the mesial aspect (group 1 = 1.04 ± 0.27; group 2 = 0.45 ± 0.005; p < 0.001). From an esthetical perspective, screw-retained restorations with ASCs and cemented restorations on angulated abutments are both effective means of restoring implants; both have excellent esthetic outcomes, but screw-retained restorations have reduced bone loss when compared to cemented ones but are more prone to mechanical complications. Still, our results must be cautiously observed given the reduced dimension of our sample. Larger studies are needed to confirm our findings. Full article
(This article belongs to the Special Issue Dental Materials Design and Innovative Treatment Approach)
Show Figures

Figure 1

13 pages, 11839 KB  
Article
Reverse Torque Value of Angulated Screw Channel Abutment before and after Cyclic Loading: An In Vitro Study
by Yu-Hsuan Chen, Yu-Ling Wu, Hung-Shyong Chen, Ching-Ping Lin and Aaron Yu-Jen Wu
J. Funct. Biomater. 2023, 14(3), 124; https://doi.org/10.3390/jfb14030124 - 24 Feb 2023
Cited by 5 | Viewed by 4150
Abstract
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two [...] Read more.
This in vitro experiment aimed to understand the difference in preload acting on an abutment screw under different angles of angulated screw-retained crown and the performance after cyclic loading. In total, thirty implants with angulated screw channel (ASC) abutments were divided into two parts. The first part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5), a 15° access channel with a specially designed zirconia crown (sASC-15) (n = 5), and a 25° access channel with a specially designed zirconia crown (sASC-25) (n = 5). The reverse torque value (RTV) was measured at 0° for each specimen. The second part consisted of three groups: a 0° access channel with a zirconia crown (ASC-0) (n = 5); a 15° access channel with a zirconia crown (ASC-15) (n = 5), and a 25° access channel with a zirconia crown (ASC-25) (n = 5). The manufacturer’s recommended torque was applied to each specimen, and baseline RTV was measured before cyclic loading. Each ASC implant assembly was cyclically loaded at 0 to 40 N with 1 million cycles at 10 Hz. RTV was measured after cyclic loading. Kruskal–Wallis test and Jonckheere–Terpstra test were used for statistical analysis. All specimens were examined under a digital microscope and scanning electron microscope (SEM) to observe the wear of the screw head before and after the whole experiment. A significant difference in the different percentages of straight RTV (sRTV) between the three groups was found (p = 0.027). The angle of ASC to the different percentages of sRTV showed a significant linear trend (p = 0.003). No significant differences were found in RTV difference after cyclic loading among the ASC-0, ASC-15, and ASC-25 groups (p = 0.212). The ASC-25 group had the most serious degree of wear based on a digital microscope and SEM examination. The ASC angle will affect the actual preload acting on a screw: the larger the ASC angle, the smaller the preload. The performance of the angled ASC groups in RTV difference was comparable to that of 0° ASC after cyclic loading. Full article
(This article belongs to the Special Issue New Trends in Biomaterials and Implants for Dentistry)
Show Figures

Figure 1

11 pages, 6518 KB  
Article
The Application of Angulated Screw-Channels in Metal-Free, Implant-Supported Restorations: A Retrospective Survival Analysis
by Edoardo Rella, Paolo De Angelis, Giovanni Damis, Antonio D’Addona and Paolo Francesco Manicone
Materials 2021, 14(22), 7006; https://doi.org/10.3390/ma14227006 - 19 Nov 2021
Cited by 14 | Viewed by 2726
Abstract
Angulated screw channels (ASC) allow the clinician to reposition the access hole of screw-retained restorations, improving the design of the rehabilitation and the esthetic outcome. Few clinical studies are available on the efficacy of these restorations, especially at longer follow-ups and with a [...] Read more.
Angulated screw channels (ASC) allow the clinician to reposition the access hole of screw-retained restorations, improving the design of the rehabilitation and the esthetic outcome. Few clinical studies are available on the efficacy of these restorations, especially at longer follow-ups and with a large number of subjects. The objective of this study was therefore to retrospectively evaluate patients rehabilitated with screw-retained restorations using ASC. The time of delivery and their adherence to the maintenance program was obtained, as well as the characteristics of the restoration and of the patient’s occlusion; a Kaplan–Meier survival curve was then built to investigate the success rate of these restorations and the effects of several variables were evaluated with a Cox model. A total of 105 subjects and 162 implants were enrolled in this study; after 42 months a success rate (92%) similar to what is reported for conventional screw-retained restorations was encountered. Monolithic zirconia restorations (n = 52) had a higher success rate (95%) when compared to partially veneered restorations (n = 53), which suffered a higher number of complications (90%). The other variables had no statistically significant effect. Implant supported prostheses adopting ASC provide a favorable outcome both in the posterior and anterior regions and can therefore be adopted to treat cases where the implant angulation is unfavorable for a conventional screw-retained prosthesis. Full article
(This article belongs to the Special Issue Innovative Restoration Dentistry Materials)
Show Figures

Figure 1

Back to TopTop