Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (8)

Search Parameters:
Keywords = acetabular labrum

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 1947 KB  
Article
Quantitative Magnetic Resonance Imaging and Patient-Reported Outcomes in Patients Undergoing Hip Labral Repair or Reconstruction
by Kyle S. J. Jamar, Adam Peszek, Catherine C. Alder, Trevor J. Wait, Caleb J. Wipf, Carson L. Keeter, Stephanie W. Mayer, Charles P. Ho and James W. Genuario
J. Imaging 2025, 11(8), 261; https://doi.org/10.3390/jimaging11080261 - 5 Aug 2025
Viewed by 1019
Abstract
This study evaluates the relationship between preoperative cartilage quality, measured by T2 mapping, and patient-reported outcomes following labral tear treatment. We retrospectively reviewed patients aged 14–50 who underwent primary hip arthroscopy with either labral repair or reconstruction. Preoperative T2 values of femoral, acetabular, [...] Read more.
This study evaluates the relationship between preoperative cartilage quality, measured by T2 mapping, and patient-reported outcomes following labral tear treatment. We retrospectively reviewed patients aged 14–50 who underwent primary hip arthroscopy with either labral repair or reconstruction. Preoperative T2 values of femoral, acetabular, and labral tissue were assessed from MRI by blinded reviewers. International Hip Outcome Tool (iHOT-12) scores were collected preoperatively and up to two years postoperatively. Associations between T2 values and iHOT-12 scores were analyzed using univariate mixed linear models. Twenty-nine patients were included (mean age of 32.5 years, BMI 24 kg/m2, 48.3% female, and 22 repairs). Across all patients, higher T2 values were associated with higher iHOT-12 scores at baseline and early postoperative timepoints (three months for cartilage and six months for labrum; p < 0.05). Lower T2 values were associated with higher 12- and 24-month iHOT-12 scores across all structures (p < 0.001). Similar trends were observed within the repair and reconstruction subgroups, with delayed negative associations correlating with worse tissue quality. T2 mapping showed time-dependent correlations with iHOT-12 scores, indicating that worse cartilage or labral quality predicts poorer long-term outcomes. These findings support the utility of T2 mapping as a preoperative tool for prognosis in hip preservation surgery. Full article
(This article belongs to the Special Issue New Developments in Musculoskeletal Imaging)
Show Figures

Figure 1

27 pages, 5071 KB  
Article
Immunohistochemical and Ultrastructural Study of the Degenerative Processes of the Hip Joint Capsule and Acetabular Labrum
by Riana Maria Huzum, Bogdan Huzum, Marius Valeriu Hînganu, Ludmila Lozneanu, Fabian Cezar Lupu and Delia Hînganu
Diagnostics 2025, 15(15), 1932; https://doi.org/10.3390/diagnostics15151932 - 31 Jul 2025
Cited by 2 | Viewed by 792
Abstract
Background/Objectives: Degenerative processes of the hip joint increasingly affect not only the articular cartilage but also periarticular structures such as the joint capsule and acetabular labrum. This study aimed to investigate the structural and molecular changes occurring in these tissues during advanced [...] Read more.
Background/Objectives: Degenerative processes of the hip joint increasingly affect not only the articular cartilage but also periarticular structures such as the joint capsule and acetabular labrum. This study aimed to investigate the structural and molecular changes occurring in these tissues during advanced hip osteoarthritis. Methods: A combined analysis using immunohistochemistry (IHC), scanning electron microscopy (SEM), and micro-computed tomography (microCT) was conducted on tissue samples from patients undergoing total hip arthroplasty and from controls with morphologically normal joints. Markers associated with proliferation (Ki67), inflammation (CD68), angiogenesis (CD31, ERG), chondrogenesis (SOX9), and lubrication (Lubricin) were evaluated. Results: The pathological group showed increased expression of Ki67, CD68, CD31, ERG, and SOX9, with a notable decrease in Lubricin. SEM analysis revealed ultrastructural disorganization, collagen fragmentation, and neovascular remodeling in degenerative samples. A significant correlation between structural damage and molecular expression was identified. Conclusions: These results suggest that joint capsule and acetabular labrum degeneration are interconnected and reflect a broader pathophysiological continuum, supporting the use of integrated IHC and SEM profiling for early detection and targeted intervention in hip joint disease. Full article
(This article belongs to the Special Issue Diagnosis and Management of Osteoporosis)
Show Figures

Figure 1

14 pages, 7655 KB  
Article
Retrospective Evaluation of Cryopreserved Human Umbilical Cord Tissue Allografts in the Supplementation of Cartilage Defects Associated with Hip Osteoarthritis
by Albert Lai, Conrad Tamea, John Shou, Anthony Okafor, Jay Sparks, Renee Dodd, Naomi Lambert, Crislyn Woods, Orion Schulte, Sarah Kovar and Tyler Barrett
J. Clin. Med. 2024, 13(14), 4040; https://doi.org/10.3390/jcm13144040 - 10 Jul 2024
Cited by 2 | Viewed by 2371
Abstract
Background: Osteoarthritis is a chronic disorder that affects the synovial joints by the progressive loss of articular cartilage. In the hip, the largest weight-bearing joint, the deterioration of articular cartilage and acetabular labrum can cause pain, diminishing the quality of life for [...] Read more.
Background: Osteoarthritis is a chronic disorder that affects the synovial joints by the progressive loss of articular cartilage. In the hip, the largest weight-bearing joint, the deterioration of articular cartilage and acetabular labrum can cause pain, diminishing the quality of life for patients. This study presents changes in reported pain scales from patients who received Wharton’s jelly applications to cartilage deterioration in the hip from the observational retrospective repository at Regenative Labs. Methods: Sixty-nine patients were selected based on inclusion criteria with patient-reported pain scales, including the Numeric Pain Rating Scale and the Western Ontario and McMaster University Osteoarthritis Index, collected at the initial application, 30, and 90-day follow-up visits. Thirteen patients received a second allograft application and had additional follow-up visits at 120 and 180 days. Results: Five of the six scales used showed a statistically significant improvement in average scores across the cohort. The greatest improvements were observed in the NPRS with a 31.36% improvement after 90 days and a 44.64% improvement for patients with two applications after 180 days. The minimal clinically important difference (MCID) was also calculated to determine the perceived value of care for each patient with 44.9% of patients exceeding the MCID and 78.3% reporting at least one level of improvement. Conclusions: The positive outcomes for the patients in this cohort suggest WJ to be a promising alternative care option for patients with structural tissue degeneration in the hip refractory to the current standard of care. Full article
Show Figures

Figure 1

13 pages, 3419 KB  
Article
Expression of Acetabular Labral Vascular Endothelial Growth Factor and Nerve Growth Factor Is Directly Associated with Hip Osteoarthritis Pain: Investigation by Immunohistochemical Staining
by Yoshihiro Sato, Tomonori Tetsunaga, Kazuki Yamada, Yoshi Kawamura, Aki Yoshida and Toshifumi Ozaki
Int. J. Mol. Sci. 2023, 24(3), 2926; https://doi.org/10.3390/ijms24032926 - 2 Feb 2023
Cited by 4 | Viewed by 2468
Abstract
The acetabular labrum enhances hip joint stability and plays a key role in osteoarthritis (OA) progression. Labral nerve endings contribute to hip OA pain. Moreover, vascular endothelial growth factor (VEGF) and nerve growth factor (NGF) are associated with pain. Consequently, we analysed VEGF [...] Read more.
The acetabular labrum enhances hip joint stability and plays a key role in osteoarthritis (OA) progression. Labral nerve endings contribute to hip OA pain. Moreover, vascular endothelial growth factor (VEGF) and nerve growth factor (NGF) are associated with pain. Consequently, we analysed VEGF and NGF expression levels in the labrum and their roles in OA. Labra obtained from OA patients were stained immunohistochemically, and labral cells were cultured and subjected to a reverse transcription (RT)–polymerase chain reaction (PCR) to analyse VEGF and NGF mRNA expression. VEGF and NGF expression were compared in each region of the labrum. Correlations between VEGF and NGF expression and age, body mass index, Kellgren–Lawrence grade, Harris Hip Score, the visual analogue scale (VAS), and Krenn score were analysed, and the RT-PCR confirmed the findings. VEGF and NGF expression were high on the labral articular side, negatively correlated with the Krenn score, and positively correlated with the VAS in early OA. VEGF and NGF mRNA expression increased significantly in patients with severe pain and decreased significantly in severely degenerated labra. In early OA, VEGF and NGF expression in the acetabular labrum was associated with the occurrence of hip pain; therefore, these factors could be effective targets for pain management. Full article
(This article belongs to the Section Molecular Neurobiology)
Show Figures

Figure 1

16 pages, 5327 KB  
Article
Mechanical and Biological Evaluation of Melt-Electrowritten Polycaprolactone Scaffolds for Acetabular Labrum Restoration
by Matthias X. T. Santschi, Stephanie Huber, Jan Bujalka, Nouara Imhof, Michael Leunig and Stephen J. Ferguson
Cells 2022, 11(21), 3450; https://doi.org/10.3390/cells11213450 - 31 Oct 2022
Cited by 13 | Viewed by 3238
Abstract
Repair or reconstruction of a degenerated or injured acetabular labrum is essential to the stability and health of the hip joint. Current methods for restoration fail to reproduce the structure and mechanical properties of the labrum. In this study, we characterized the structure [...] Read more.
Repair or reconstruction of a degenerated or injured acetabular labrum is essential to the stability and health of the hip joint. Current methods for restoration fail to reproduce the structure and mechanical properties of the labrum. In this study, we characterized the structure and tensile mechanical properties of melt-electrowritten polycaprolactone scaffolds of varying architectures and assessed the labrum cell compatibility of selected graft candidates. Cell compatibility was assessed using immunofluorescence of the actin skeleton. First, labrum explants were co-cultured with scaffold specimen to investigate the scaffold compatibility with primary cells. Second, effects of pore size on pre-cultured seeded labrum cells were studied. Third, cell compatibility under dynamic stretching was examined. Grid-like structures showed favorable tensile properties with decreasing fibre spacing. Young’s moduli ranging from 2.33 ± 0.34 to 13.36 ± 2.59 MPa were measured across all structures. Primary labrum cells were able to migrate from co-cultured labrum tissue specimens into the scaffold and grow in vitro. Incorporation of small-diameter-fibre and interfibre spacing improved cell distribution and cell spreading, whereas mechanical properties were only marginally affected. Wave-patterned constructs reproduced the non-linear elastic behaviour of native labrum tissue and, therefore, allowed for physiological cyclic tensile strain but showed decreased cell compatibility under dynamic loading. In conclusion, melt-electrowritten polycaprolactone scaffolds are promising candidates for labral grafts; however, further development is required to improve both the mechanical and biological compatibility. Full article
Show Figures

Figure 1

9 pages, 665 KB  
Article
The Modified Longitudinal Capsulotomy by Outside-In Approach in Hip Arthroscopy for Femoroplasty and Acetabular Labrum Repair—A Cohort Study
by Shuang Cong, Jianying Pan, Guangxin Huang, Denghui Xie and Chun Zeng
J. Clin. Med. 2022, 11(15), 4548; https://doi.org/10.3390/jcm11154548 - 4 Aug 2022
Cited by 10 | Viewed by 2171
Abstract
Hip arthroscopy is difficult to perform due to the limited arthroscopic view. To solve this problem, the capsulotomy is an important technique. However, the existing capsulotomy approaches were not perfect in the surgical practice. Thus, this study aimed to propose a modified longitudinal [...] Read more.
Hip arthroscopy is difficult to perform due to the limited arthroscopic view. To solve this problem, the capsulotomy is an important technique. However, the existing capsulotomy approaches were not perfect in the surgical practice. Thus, this study aimed to propose a modified longitudinal capsulotomy by outside-in approach and demonstrate its feasibility and efficacy in arthroscopic femoroplasty and acetabular labrum repair. A retrospective cohort study was performed and twenty-two postoperative patients who underwent hip arthroscopy in our hospital from January 2019 to December 2021 were involved in this study. The patients (14 females and 8 males) had a mean age of 38.26 ± 12.82 years old. All patients were diagnosed cam deformity and labrum tear in the operation and underwent arthroscopic femoroplasty and labrum repair by the modified longitudinal capsulotomy. The mean follow-up time was 10.4 months with a range of 6–12 months. There were no major complications, including infection, neurapraxias, hip instability or revision in any patients. The average mHHS were 74.4 ± 15.2, 78.2 ± 13.7 and 85.7 ± 14.5 in 3 months, 6 months and 12 months after surgery, respectively, which were all better than that before surgery (44.9 ± 8.6) (p < 0.05). The average VAS were 2.8 ± 1.2, 1.5 ± 0.6 and 1.2 ± 0.7 in 3 months, 6 months and 12 months after surgery, respectively, which were all lower than that before surgery (5.5 ± 2.0) (p < 0.05). The modified longitudinal capsulotomy by outside-in approach is proved to be a safe and feasible method for hip arthroscopy considering to the feasibility, efficacy and security. The arthroscopic femoroplasty and labrum repair can be performed conveniently by this approach and the patient reported outcomes after surgery were better that before surgery in short-term follow-up. This new method is promising and suggested to be widely used clinically. Full article
(This article belongs to the Special Issue Advancements in Sports Medicine)
Show Figures

Figure 1

14 pages, 4092 KB  
Article
Mechanical and Cytocompatibility Evaluation of UHMWPE/PCL/Bioglass® Fibrous Composite for Acetabular Labrum Implant
by Adhi Anindyajati, Philip Boughton and Andrew J. Ruys
Materials 2019, 12(6), 916; https://doi.org/10.3390/ma12060916 - 19 Mar 2019
Cited by 9 | Viewed by 3757
Abstract
In this study, a fibrous composite was developed as synthetic graft for labral reconstruction treatment, comprised of ultra-high molecular weight polyethylene (UHMWPE) fabric, ultrafine fibre of polycaprolactone (PCL), and 45S5 Bioglass®. This experiment aimed to examine the mechanical performance and cytocompatibility [...] Read more.
In this study, a fibrous composite was developed as synthetic graft for labral reconstruction treatment, comprised of ultra-high molecular weight polyethylene (UHMWPE) fabric, ultrafine fibre of polycaprolactone (PCL), and 45S5 Bioglass®. This experiment aimed to examine the mechanical performance and cytocompatibility of the composite. Electrospinning and a slurry dipping technique were applied for composite fabrication. To assess the mechanical performance of UHMWPE, tensile cyclic loading test was carried out. Meanwhile, cytocompatibility of the composite on fibroblastic cells was examined through a viability assay, as well as SEM images to observe cell attachment and proliferation. The mechanical test showed that the UHMWPE fabric had a mean displacement of 1.038 mm after 600 cycles, approximately 4.5 times greater resistance compared to that of natural labrum, based on data obtained from literature. A viability assay demonstrated the predominant occupation of live cells on the material surface, suggesting that the composite was able to provide a viable environment for cell growth. Meanwhile, SEM images exhibited cell adhesion and the formation of cell colonies on the material surface. These results indicated that the UHMWPE/PCL/Bioglass® composite could be a promising material for labrum implants. Full article
(This article belongs to the Special Issue Bioceramics: Bioinert, Bioactive, and Coatings)
Show Figures

Figure 1

23 pages, 10645 KB  
Article
Modelling and Optimization of Polycaprolactone Ultrafine-Fibres Electrospinning Process Using Response Surface Methodology
by Adhi Anindyajati, Philip Boughton and Andrew J. Ruys
Materials 2018, 11(3), 441; https://doi.org/10.3390/ma11030441 - 17 Mar 2018
Cited by 21 | Viewed by 4992
Abstract
Electrospun fibres have gained broad interest in biomedical applications, including tissue engineering scaffolds, due to their potential in mimicking extracellular matrix and producing structures favourable for cell and tissue growth. The development of scaffolds often involves multivariate production parameters and multiple output characteristics [...] Read more.
Electrospun fibres have gained broad interest in biomedical applications, including tissue engineering scaffolds, due to their potential in mimicking extracellular matrix and producing structures favourable for cell and tissue growth. The development of scaffolds often involves multivariate production parameters and multiple output characteristics to define product quality. In this study on electrospinning of polycaprolactone (PCL), response surface methodology (RSM) was applied to investigate the determining parameters and find optimal settings to achieve the desired properties of fibrous scaffold for acetabular labrum implant. The results showed that solution concentration influenced fibre diameter, while elastic modulus was determined by solution concentration, flow rate, temperature, collector rotation speed, and interaction between concentration and temperature. Relationships between these variables and outputs were modelled, followed by an optimization procedure. Using the optimized setting (solution concentration of 10% w/v, flow rate of 4.5 mL/h, temperature of 45 °C, and collector rotation speed of 1500 RPM), a target elastic modulus of 25 MPa could be achieved at a minimum possible fibre diameter (1.39 ± 0.20 µm). This work demonstrated that multivariate factors of production parameters and multiple responses can be investigated, modelled, and optimized using RSM. Full article
Show Figures

Figure 1

Back to TopTop