Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = SpyGlass™ DS

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 492 KiB  
Article
Clinical Outcomes of Digital Cholangioscopy-Guided Procedures for the Diagnosis of Biliary Strictures and Treatment of Difficult Bile Duct Stones: A Single-Center Large Cohort Study
by Hirohito Minami, Shuntaro Mukai, Atsushi Sofuni, Takayoshi Tsuchiya, Kentaro Ishii, Reina Tanaka, Ryosuke Tonozuka, Mitsuyoshi Honjo, Kenjiro Yamamoto, Kazumasa Nagai, Yukitoshi Matsunami, Yasutsugu Asai, Takashi Kurosawa, Hiroyuki Kojima, Toshihiro Homma and Takao Itoi
J. Clin. Med. 2021, 10(8), 1638; https://doi.org/10.3390/jcm10081638 - 12 Apr 2021
Cited by 20 | Viewed by 3008
Abstract
Although Spy DS (SpyGlass DS Direct Visualization System) is considered to be useful for the diagnosis of bile duct strictures and the treatment of bile duct stones, there is limited data to date validating its efficacy. We hence retrospectively evaluated the clinical outcomes [...] Read more.
Although Spy DS (SpyGlass DS Direct Visualization System) is considered to be useful for the diagnosis of bile duct strictures and the treatment of bile duct stones, there is limited data to date validating its efficacy. We hence retrospectively evaluated the clinical outcomes of the use of Spy DS in a large number of patients. A total of 183 patients who underwent Spy DS-guided procedures for indeterminate bile duct strictures (n = 93) and bile duct stones (n = 90) were analyzed retrospectively. All patients (93/93) with bile duct strictures successfully underwent visual observation, and 95.7% (89/93) of these patients successfully underwent direct biopsy. The sensitivity, specificity, and overall accuracy were 94.7%, 83.3%, and 90.3%, respectively, for visual impression; 80.9%, 100%, and 89.2%, respectively, for histopathological analysis of a direct biopsy; and 96.5%, 91.7%, and 94.6%, respectively, for visual impression combined with biopsy. Successful visualization of the stones was achieved in 98.9% (89/90) of the patients, and complete stone removal was achieved in 92.2% (83/90) of the patients, with an average of 3.3 procedures. The adverse events rate was 17.5% (32/183; cholangitis in 15 patients, fever the following day in 25, pancreatitis in 1, hemorrhage in 1, and gastrointestinal perforation in 1). No administration of antibiotics before the procedure was found to be a statistically significant risk factor for the development of fever after the procedure (p < 0.01). Spy DS-guided procedures are effective for the diagnosis and treatment of bile duct lesions and can be performed with a low risk of serious adverse events. Full article
(This article belongs to the Special Issue Clinical Advances of Endoscopy in Pancreaticobiliary Disease)
Show Figures

Figure 1

11 pages, 1326 KiB  
Review
Efficacy and Safety of Digital Single-Operator Cholangioscopy in the Diagnosis of Indeterminate Biliary Strictures by Targeted Biopsies: A Systematic Review and Meta-Analysis
by Li-Jia Wen, Jun-Hong Chen, Hong-Ji Xu, Qiong Yu and Kai Liu
Diagnostics 2020, 10(9), 666; https://doi.org/10.3390/diagnostics10090666 - 2 Sep 2020
Cited by 43 | Viewed by 4022
Abstract
Background: Biliary strictures are frequently encountered in clinical practice. The determination of their nature is often difficult. This study aims to systematically evaluate the efficacy and safety of the second generation of digital single-operator cholangioscopy (SpyGlass DS, DSOC) in indeterminate biliary strictures (IBDS) [...] Read more.
Background: Biliary strictures are frequently encountered in clinical practice. The determination of their nature is often difficult. This study aims to systematically evaluate the efficacy and safety of the second generation of digital single-operator cholangioscopy (SpyGlass DS, DSOC) in indeterminate biliary strictures (IBDS) through biopsies. Methods: All relative studies published in Medline, the Cochrane Library, Web of Science, and EMBASE were included. The diagnostic tests for IBDS were compared to the surgical histology, autopsy, or long-term clinical follow-up. The methodological quality of the included studies was evaluated by the Quality Assessment of Studies of Diagnostic Accuracy Included in Systematic Reviews (QUADAS-2). Results: A total of 11 studies, which involved 356 patients diagnosed through biopsies, were included. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio were 0.74 (95% CI: 0.67–0.80), 0.98 (95% CI: 0.95–1.00), 10.52 (95% CI: 5.45–20.32), 0.31 (95% CI: 0.23–0.41), and 65.18 (95% CI: 26.79–158.61), respectively. The area under the curve (AUC) was 0.9479, and the pooled adverse event rate was 7%. The sensitivity and specificity in the heterogeneity analysis were I2 = 48.1% and I2 = 25.4%, respectively. Conclusion: SpyGlass DS is a safe and effective technique for IBDS. However, future randomized trials are needed to determine optimal number of biopsies. Full article
Show Figures

Figure 1

Back to TopTop