Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = Siemens immulite

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 2591 KiB  
Article
Method Validation and Establishment of Reference Intervals for an Insulin-like Growth Factor-1 Chemiluminescent Immunoassay in Cats
by Arne Güssow, Sabine Thalmeier, Ruth Gostelow, Judith Langenstein, Gesine Foerster, Natali Bauer and Katarina Hazuchova
Vet. Sci. 2023, 10(9), 575; https://doi.org/10.3390/vetsci10090575 - 15 Sep 2023
Cited by 3 | Viewed by 2962
Abstract
Previously, radioimmunoassay (RIA) has been the only assay to measure insulin-like growth factor-1 (IGF-1) to diagnose hypersomatotropism (HS). Due to radiation concerns, availability, and the cost of IGF-1 RIA, validation of assays for automated analysers such as a chemiluminescent immunoassay (CLIA) is needed. [...] Read more.
Previously, radioimmunoassay (RIA) has been the only assay to measure insulin-like growth factor-1 (IGF-1) to diagnose hypersomatotropism (HS). Due to radiation concerns, availability, and the cost of IGF-1 RIA, validation of assays for automated analysers such as a chemiluminescent immunoassay (CLIA) is needed. The aim of this study was to validate a CLIA for measurement of feline IGF-1 (IMMULITE 2000® XPi, Siemens Medical Solutions Diagnostics, Malvern, PA, USA) compared to IGF1 RIA, establish reference interval (RI), and determine a cut-off value for diagnosis of HS in diabetic cats. Validation of assay performance included precision, linearity, and recovery studies. Right-sided RI was determined using surplus serum of 50 healthy adult cats. Surplus serum samples of diabetic cats with known IGF-1 concentration with (n = 32/68) and without HS (n = 36/68) were used for method comparison with RIA. The cut-off for diagnosis of HS was established using receiver operating characteristic (ROC) analysis. The intra-assay coefficient of variation (CV) was ≤4.7%, and the inter-assay CV was ≤5.6% for samples with low, medium, and high IGF-1 concentration. Linearity was excellent (R2 > 0.99). The correlation between CLIA and RIA was very high (rs = 0.97), with a mean negative bias for CLIA of 24.5%. The upper limit of RI was 670 ng/mL. ROC analysis showed an area under the curve of 0.94, with best cut-off for diagnosis of HS at 746 ng/mL (sensitivity, 84.4%; specificity, 97.2%). The performance of CLIA was good, and the RI and cut-off for HS diagnosis established in this study allow for CLIA to be used in routine work-up of diabetic cats. Full article
(This article belongs to the Section Veterinary Internal Medicine)
Show Figures

Figure 1

14 pages, 2272 KiB  
Article
Analytical Validation of the IMMULITE® 2000 XPi Progesterone Assay for Quantitative Analysis in Ovine Serum
by Kristi L. Jones, Ameer A. Megahed, Brittany N. Diehl, Ann M. Chan, Oscar Hernández, Catalina Cabrera and João H. J. Bittar
Animals 2022, 12(24), 3534; https://doi.org/10.3390/ani12243534 - 14 Dec 2022
Cited by 2 | Viewed by 2391
Abstract
Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. [...] Read more.
Monitoring circulating progesterone (P4) concentration is an important component of basic and applied reproduction research and clinical settings. IMMULITE® 2000 XPi (Siemens) is a newly upgraded fully automated immunoassay system marketed for human use to measure concentrations of different analytes including P4. Our objective was therefore to characterize the analytical performance of the IMMULITE® 2000 XPi P4 immunoassay across the reportable range in ovine serum. This validation of analytical performance included determining (1) linearity, (2) precision through within-run, and between-run coefficient of variation (CV) calculations, (3) accuracy through bias calculations for spiking-recovery bias and interlaboratory (range and average based) bias for two laboratories across the reportable range (0.2–40 ng/mL). The average within-run and between-run precision (CV%) across the reportable range of the IMMULITE® 2000 XPi P4 immunoassay for serum P4 concentration were both <5%, ranging between 2–8%. The average Observed Total Analytic Error (TEo) reported here for serum P4 concentration across the reportable range was ~30%, ranging from 14.8–59.4%, regardless of the considered bias. Based on these data we conclude that the automated IMMULITE® 2000 XPi P4 immunoassay provides a precise, accurate, reliable, and safe method for measuring P4 concentration ovine serum. Full article
(This article belongs to the Section Small Ruminants)
Show Figures

Figure 1

8 pages, 719 KiB  
Article
Aspergillus fumigatus and Aspergillus flavus-Specific IgG Cut-Offs for the Diagnosis of Chronic Pulmonary Aspergillosis in Pakistan
by Kauser Jabeen, Joveria Farooqi, Nousheen Iqbal, Khalid Wahab and Muhammad Irfan
J. Fungi 2020, 6(4), 249; https://doi.org/10.3390/jof6040249 - 26 Oct 2020
Cited by 10 | Viewed by 4379
Abstract
Despite a high burden of chronic pulmonary aspergillosis (CPA) in Pakistan, Aspergillus-specific IgG testing is currently not available. Establishing cut-offs for Aspergillus-specific IgG for CPA diagnosis is crucial due to geographical variation. In settings such as Pakistan, where non-Aspergillus fumigatus [...] Read more.
Despite a high burden of chronic pulmonary aspergillosis (CPA) in Pakistan, Aspergillus-specific IgG testing is currently not available. Establishing cut-offs for Aspergillus-specific IgG for CPA diagnosis is crucial due to geographical variation. In settings such as Pakistan, where non-Aspergillus fumigatus (mainly A. flavus) Aspergillus species account for the majority of CPA cases, there is a need to explore additional benefit of Aspergillus flavus-specific IgG detection along with A. fumigatus-specific IgG detection. This study was conducted at the Aga Khan University, Karachi, Pakistan after ethical approval. Serum for IgG detection were collected after informed consent from healthy controls (n = 21), diseased controls (patients with lung diseases, n = 18), and CPA patients (n = 21). A. fumigatus and A. flavus IgG were detected using Siemens immulite assay. The sensitivity and specificity of A. fumigatus-specific IgG were 80.95% and 82.05%, respectively at a cut-off of 20 mg/L. The sensitivity and specificity of A. flavus-specific IgG were 80.95% and 79.49% at a cut-off of 30 mg/L. We report, for the first time, performance of A. flavus-specific IgG for CPA diagnosis. Although there was no statistically significant difference between the performance of both antigens, it seems contextually relevant to include A. flavus IgG in the CPA diagnostic algorithm in regions with higher non-A. fumigatus CPA infections. Full article
(This article belongs to the Special Issue Chronic Pulmonary Aspergillosis)
Show Figures

Figure 1

Back to TopTop