Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (10)

Search Parameters:
Keywords = Plex Elite 9000

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
9 pages, 1213 KiB  
Article
Choroidal and Choriocapillaris Changes after Photodynamic Therapy and Subthreshold Micropulse Laser Treatment for Central Serous Chorioretinopathy
by Maria Ludovica Ruggeri, Marta Di Nicola, Marzia Passamonti, Carolina Lorenzi, Alberto Quarta, Rodolfo Mastropasqua and Lisa Toto
Medicina 2024, 60(10), 1674; https://doi.org/10.3390/medicina60101674 - 12 Oct 2024
Cited by 2 | Viewed by 1260
Abstract
Background and Objectives: The aim of the present study is to analyze choroidal and choriocapillaris structural and functional changes in eyes affected by Central serous chorioretinopathy after Photodynamic Therapy (PDT) and Subthreshold Micropulse laser (SML) treatment. Materials and Methods: Forty-two eyes [...] Read more.
Background and Objectives: The aim of the present study is to analyze choroidal and choriocapillaris structural and functional changes in eyes affected by Central serous chorioretinopathy after Photodynamic Therapy (PDT) and Subthreshold Micropulse laser (SML) treatment. Materials and Methods: Forty-two eyes of forty-two patients were analyzed in this observational study. Twenty-four patients underwent SML treatment, whereas eighteen patients were treated with PDT. Examinations were performed at baseline and after 3 months of treatment. Main outcome measures were: Best corrected visual acuity (BCVA), central macular thickness (CMT), central choroidal thickness (CCT), pigment epithelial detachment (PED) presence and maximum height (PEDMH), and choroidal vascularity index (CVI) measured by means of Spectralis HRA + OCT (Heidelberg Engineering, Heidelberg, Germany) Optical coherence tomography (OCT) and choriocapillaris flow voids (CCFV) measured on Optical Coherence Tomography Angiography (OCT-A) platform PLEX Elite 9000 device (Carl Zeiss Meditec Inc., Dublin, CA, USA). Results: Changes in BCVA were registered in both groups over time (p < 0.001). Structural changes in terms of reduced CMT and PED presence were noted in the two groups at follow-up (p < 0.001 and p = 0.001, respectively). Structural and functional choroidal changes were found in the two groups with reduced CCT and CVI over time (p = 0.004 and p = 0.007, respectively), with significant differences between the two groups for CVI parameter (p = 0.001). CCFV increased over time in the PDT group and decreased in the SML group. Conclusions: PDT and SML are effective approaches in CSC eyes and are able to improve structural and functional parameters over time. Choroidal and choriocapillaris parameters are promising biomarkers able to monitor disease course, showing greater impact of PDT on choroid-choriocapillaris complex over time. Full article
(This article belongs to the Special Issue Retinal Diseases: Clinical Presentation and Novel Treatments)
Show Figures

Figure 1

11 pages, 475 KiB  
Article
Analysis of Macular Vascularization Using Optical Coherence Tomography Angiography in Patients with Obstructive Sleep Apnea Syndrome: A Prospective Clinical Study
by Laura Abdessater, Matthieu Hein and Florence Rasquin
Medicina 2024, 60(5), 757; https://doi.org/10.3390/medicina60050757 - 2 May 2024
Cited by 2 | Viewed by 1876
Abstract
Background and Objectives: Given the conflicting data available in the literature, this study aimed to investigate the impact of obstructive sleep apnea syndrome (OSAS) on the macular vascular density (VD) and perfusion density (PD). Materials and Methods: Based on the obstructive apnea–hypopnea index [...] Read more.
Background and Objectives: Given the conflicting data available in the literature, this study aimed to investigate the impact of obstructive sleep apnea syndrome (OSAS) on the macular vascular density (VD) and perfusion density (PD). Materials and Methods: Based on the obstructive apnea–hypopnea index (OAHI), 61 prospectively recruited patients were assigned to either a control group (n = 12; OAHI < 5/h) or an OSAS group (n = 49; OAHI ≥ 5/h). The macular VD and PD of the superficial and deep capillary plexuses (SCP and DCP, respectively) were measured in the parafoveolar and perifoveolar areas using Zeiss PLEX Elite 9000 (6 × 6 mm). The values were compared between the control and OSAS groups. Results: Compared with the control group, the OSAS group demonstrated an increased VD of the DCP in the parafoveolar and perifoveolar areas and PD of the DCP in the perifoveolar area. No significant differences in either the macular VD or PD of the SCP were observed. There was no correlation between the OAHI and macular VD or PD. Conclusions: This study indicates that collateral vessel formation and possible retinal vasodilation occur in the DCP of patients with OSAS. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

18 pages, 13880 KiB  
Article
Hybrid Fusion of High-Resolution and Ultra-Widefield OCTA Acquisitions for the Automatic Diagnosis of Diabetic Retinopathy
by Yihao Li, Mostafa El Habib Daho, Pierre-Henri Conze, Rachid Zeghlache, Hugo Le Boité, Sophie Bonnin, Deborah Cosette, Stephanie Magazzeni, Bruno Lay, Alexandre Le Guilcher, Ramin Tadayoni, Béatrice Cochener, Mathieu Lamard and Gwenolé Quellec
Diagnostics 2023, 13(17), 2770; https://doi.org/10.3390/diagnostics13172770 - 26 Aug 2023
Cited by 7 | Viewed by 2142
Abstract
Optical coherence tomography angiography (OCTA) can deliver enhanced diagnosis for diabetic retinopathy (DR). This study evaluated a deep learning (DL) algorithm for automatic DR severity assessment using high-resolution and ultra-widefield (UWF) OCTA. Diabetic patients were examined with 6×6 mm2 high-resolution [...] Read more.
Optical coherence tomography angiography (OCTA) can deliver enhanced diagnosis for diabetic retinopathy (DR). This study evaluated a deep learning (DL) algorithm for automatic DR severity assessment using high-resolution and ultra-widefield (UWF) OCTA. Diabetic patients were examined with 6×6 mm2 high-resolution OCTA and 15×15 mm2 UWF-OCTA using PLEX®Elite 9000. A novel DL algorithm was trained for automatic DR severity inference using both OCTA acquisitions. The algorithm employed a unique hybrid fusion framework, integrating structural and flow information from both acquisitions. It was trained on data from 875 eyes of 444 patients. Tested on 53 patients (97 eyes), the algorithm achieved a good area under the receiver operating characteristic curve (AUC) for detecting DR (0.8868), moderate non-proliferative DR (0.8276), severe non-proliferative DR (0.8376), and proliferative/treated DR (0.9070). These results significantly outperformed detection with the 6×6 mm2 (AUC = 0.8462, 0.7793, 0.7889, and 0.8104, respectively) or 15×15 mm2 (AUC = 0.8251, 0.7745, 0.7967, and 0.8786, respectively) acquisitions alone. Thus, combining high-resolution and UWF-OCTA acquisitions holds the potential for improved early and late-stage DR detection, offering a foundation for enhancing DR management and a clear path for future works involving expanded datasets and integrating additional imaging modalities. Full article
Show Figures

Figure 1

17 pages, 9660 KiB  
Article
Does PLEX® Elite 9000 OCT Identify and Characterize Most Posterior Pole Lesions in Highly Myopic Patients?
by Pablo Arlanzon-Lope, Miguel Angel. Campos, Ivan Fernandez-Bueno and Rosa M. Coco-Martin
J. Clin. Med. 2023, 12(5), 1846; https://doi.org/10.3390/jcm12051846 - 25 Feb 2023
Cited by 2 | Viewed by 3500
Abstract
High myopia (HM) is defined as an axial length (AL) ≥ 26 mm that may result in various pathologies that constitute pathologic myopia (PM). The PLEX® Elite 9000 (Carl Zeiss AC, Jena, Germany) is a new swept-source optical coherence tomography (SS-OCT) underdevelopment [...] Read more.
High myopia (HM) is defined as an axial length (AL) ≥ 26 mm that may result in various pathologies that constitute pathologic myopia (PM). The PLEX® Elite 9000 (Carl Zeiss AC, Jena, Germany) is a new swept-source optical coherence tomography (SS-OCT) underdevelopment that allows wider, deeper and more detailed posterior-segment visualization; it can acquire ultra-wide OCT angiography (OCTA) or new ultra-wide high-density scans in one image. We assessed the technology’s ability to identify/characterize/quantify staphylomas and posterior pole lesions or image biomarkers in highly myopic Spanish patients and estimate the technology’s potential to detect macular pathology. The instrument acquired 6 × 6 OCTA, 12 × 12 or 6 × 6 OCT cubes, and at least two high-definition spotlight single scans. A hundred consecutive patients (179 eyes; age, 51.4 ± 16.8 years; AL, 28.8 ± 2.33 mm) were recruited in one center for this prospective observational study. Six eyes were excluded because images were not acquired. The most common alterations were perforating scleral vessels (88.8%), classifiable staphyloma (68.7%), vascular folds (43%), extrafoveal retinoschisis (24%), dome-shaped macula (15.6%), and more uncommonly, scleral dehiscence (4.46%), intrachoroidal cavitation (3.35%), and macular pit (2.2%). The retinal thickness of these patients decreased, and the foveal avascular zone increased in the superficial plexus compared with normal eyes. SS-OCT is a novel potent tool that can detect most main posterior pole complications in PM and may provide us with a better understanding of the associated pathologies; some pathologies were identifiable only with this new kind of equipment, such as perforating scleral vessels, which seem to be the most common finding and not so frequently related to choroidal neovascularization, as previously reported. Full article
(This article belongs to the Special Issue Imaging in Ophthalmology—Volume I)
Show Figures

Figure 1

8 pages, 2730 KiB  
Article
Iris Racemose Hemangioma Assessment with Swept Source Optical Coherence Tomography Angiography: A Feasibility Study and Stand-Alone Comparison
by Filippo Confalonieri, Huy Bao Ngo, Helga Halldorsdottir Petersen, Nils Andreas Eide and Goran Petrovski
J. Clin. Med. 2022, 11(21), 6575; https://doi.org/10.3390/jcm11216575 - 6 Nov 2022
Cited by 1 | Viewed by 2485
Abstract
Purpose: To evaluate arteriovenous malformations (AVM) with swept-source (SS) optical coherence tomography (OCT) angiography (OCTA) in iris racemose hemangioma and compare it with traditional intravenous iris fluorescein angiography (IVFA). Methods: A cross-sectional observational clinical study was conducted on patients with iris racemose hemangioma [...] Read more.
Purpose: To evaluate arteriovenous malformations (AVM) with swept-source (SS) optical coherence tomography (OCT) angiography (OCTA) in iris racemose hemangioma and compare it with traditional intravenous iris fluorescein angiography (IVFA). Methods: A cross-sectional observational clinical study was conducted on patients with iris racemose hemangioma with the ZEISS PLEX Elite 9000 SS OCT & OCTA. Results: Three eyes of three patients were imaged. Iris racemose hemangiomas demonstrated a tortuous, well-defined, and continuous course of the AVM. The ZEISS PLEX Elite 9000 SS OCT & OCTA allowed for a detailed visualization of the ARM and was superior to IVFA in depicting small caliber, fine vessels. Conclusions: SS-OCTA may provide a dye-free, no-injection, cost-effective method comparable to spectral domain OCTA and IVFA for diagnosing and monitoring iris racemose hemangiomas for growth and vascularity. Full article
(This article belongs to the Special Issue Optical Coherence Tomography Imaging: Advances in Ophthalmology)
Show Figures

Figure 1

12 pages, 3675 KiB  
Article
Undetectable Macular Neovascularization on OCT Angiography in Age Related Macular Degeneration: Comparison between Different Devices
by Meryem Filali Ansary, Emanuele Crincoli, Oudy Semoun, Joel Uzzan, Francesca Amoroso, Camille Jung, Alexandra Miere and Eric Souied
Medicina 2022, 58(9), 1246; https://doi.org/10.3390/medicina58091246 - 8 Sep 2022
Cited by 4 | Viewed by 2403
Abstract
Background and Objectives: The aim of this study was to report the characteristics of macular neovascularization (MNV) with undetectable flow on optical coherence tomography angiography (OCTA) in neovascular age related macular degeneration (nAMD), and compare them with the characteristics of detectable MNV. [...] Read more.
Background and Objectives: The aim of this study was to report the characteristics of macular neovascularization (MNV) with undetectable flow on optical coherence tomography angiography (OCTA) in neovascular age related macular degeneration (nAMD), and compare them with the characteristics of detectable MNV. Materials and Methods: Patients with a diagnosis of nAMD who underwent dye imaging and OCTA in the same day were included and divided into two groups: undetectable and detectable flow on OCTA. Three OCTA devices were used, two with spectral-domain technology (AngioVue, RTVue 100xAvanti, Optovue, Freemont, CA, USA and Heidelberg OCT2 Beta Angiography Module, Heidelberg Engineering, Germany) and one swept-source OCTA (PlexElite 9000; Carl Zeiss Meditec, Inc., Dublin, CA, USA). We studied the demographics, neovascularization characteristics, and OCTA device and acquisition characteristics for both groups. Results: A global comparison between Group 1 and Group 2 was made, followed by an analysis of variables associated with (un)detectability for each OCTA device. A total of 108 eyes were included: 90 in the detectable group (Group 1) and 18 in the undetectable group (Group 2), corresponding to a global sensitivity of OCTA for the detection of MNV of 83.49%. There was a statistically significant difference between the two groups regarding MNV type (p = 0.02) and PED height (p = 0.017). For the three devices, detection sensitivity with automatic segmentation was significantly lower than with manual segmentation. For Heidelberg, PED Height and scan quality explained 68.3% of the undetectability. For AngioVue, PED Height and absence of hemorrhage explained 67.9% of undetectability. Conclusions: In this study, we found a global sensitivity of 83.49% for the three OCTA devices combined, with a range from 55.5% to 96.26% depending on the segmentation and OCTA device. This means that undetectable/undetected MNV can represent up to 45% of the examinations, eventually misdiagnosing choroidal neovascularization for 1 out every 2 patients. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

13 pages, 2667 KiB  
Article
Repeatability and Reproducibility of Retinal Fractal Dimension Measured with Swept-Source Optical Coherence Tomography Angiography in Healthy Eyes: A Proof-of-Concept Study
by Louis Arnould, Déa Haddad, Florian Baudin, Pierre-Henry Gabrielle, Marc Sarossy, Alain M. Bron, Behzad Aliahmad and Catherine Creuzot-Garcher
Diagnostics 2022, 12(7), 1769; https://doi.org/10.3390/diagnostics12071769 - 21 Jul 2022
Cited by 4 | Viewed by 2706
Abstract
The retinal vascular network fractal dimension (FD) could be a promising imaging biomarker. Our objective was to evaluate its repeatability and reproducibility in healthy eyes. A cross-sectional study was undertaken with young, healthy volunteers who had no reported cardiac risk factors or ocular [...] Read more.
The retinal vascular network fractal dimension (FD) could be a promising imaging biomarker. Our objective was to evaluate its repeatability and reproducibility in healthy eyes. A cross-sectional study was undertaken with young, healthy volunteers who had no reported cardiac risk factors or ocular disease history. For each participant, three SS-OCTA images (12 × 12 mm) were acquired using the Plex Elite 9000 (Carl Zeiss Meditec AG, Jena, Germany) by two ophthalmologists. Automated segmentation was obtained from both the superficial and deep capillary plexuses. FD was estimated by box counting. The intraclass correlation coefficients (ICC) were used as measures for repeatability and reproducibility. A total of 43 eyes of healthy volunteers were included. The mean ± standard deviation (SD) age was 30 ± 6.2 years. The results show good repeatability. The ICC was 0.722 (95% CI, 0.541–0.839) in the superficial capillary plexus and 0.828 (95% CI, 0.705–0.903) in the deep capillary plexus. For reproducibility, the ICC was 0.651 (95% CI, 0.439–0.795) and 0.363 (95% CI, 0.073–0.596) at the superficial and deep capillary plexus, respectively. In this study, the FD of the vascular network measured via SS-OCTA showed good repeatability and reproducibility in healthy participants. Full article
Show Figures

Figure 1

11 pages, 1553 KiB  
Article
Changes in Iris Perfusion Following Scleral Buckle Surgery for Rhegmatogenous Retinal Detachment: An Anterior Segment Optical Coherence Tomography Angiography (AS-OCTA) Study
by Rossella D’Aloisio, Pasquale Viggiano, Enrico Borrelli, Mariacristina Parravano, Aharrh-Gnama Agbèanda, Federica Evangelista, Giada Ferro, Lisa Toto and Rodolfo Mastropasqua
J. Clin. Med. 2020, 9(4), 1231; https://doi.org/10.3390/jcm9041231 - 24 Apr 2020
Cited by 20 | Viewed by 3991
Abstract
Purpose: To investigate iris vasculature changes following scleral buckling (SB) surgery in eyes with rhegmatogenous retinal detachment (RRD) with anterior-segment (AS) optical coherence tomography angiography (OCTA). Methods: In this prospective study, enrolled subjects were imaged with an SS-OCTA system (PLEX Elite 9000, Carl [...] Read more.
Purpose: To investigate iris vasculature changes following scleral buckling (SB) surgery in eyes with rhegmatogenous retinal detachment (RRD) with anterior-segment (AS) optical coherence tomography angiography (OCTA). Methods: In this prospective study, enrolled subjects were imaged with an SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). Image acquisition of the iris was obtained using an AS lens and a manual focusing adjustment in the iris using the retina imaging software. The quantitative analysis was performed in eight different iris regions: (i) superior, (ii) supero-temporal, (iii) supero-nasal, (iv) nasal, (v) temporal, (vi) inferior, (vii) infero-temporal, (viii) infero nasal which, were defined as squares with area of 1.5 mm2. Results: Fifteen eyes of 15 patients (six females; nine males) were included. Anterior segment optical coherence tomography angiography (AS-OCTA) parameters of the iris were statistically compared at baseline (preoperatively), 1 week, 1 month and 6 months after SB. At post-operative 1 week, perfusion density (PD) showed a significant decrease from 66.8 ± 13.2% to 58.55 ± 12.0% in the iris supero-nasal region (p = 0.016). However, at the 1-month follow-up visit, iris PD was significantly lower in all the analyzed iris regions, apart from the superior one. Conclusions: This study is the first description of AS-OCTA in patients undergoing SB. Our results showed a uniform reduction of the iris vessel network at 1 month after surgery, supporting the clinical use of AS-OCTA to identify early iris perfusion changes as potential predictive biomarkers of vascular disorders. Full article
(This article belongs to the Special Issue New Advances in Retinal Research)
Show Figures

Figure 1

13 pages, 1903 KiB  
Article
Widefield Swept Source OCTA in Retinitis Pigmentosa
by Rodolfo Mastropasqua, Rossella D’Aloisio, Chiara De Nicola, Giada Ferro, Alfonso Senatore, Daniele Libertini, Guido Di Marzio, Marta Di Nicola, Giuseppe Di Martino, Luca Di Antonio and Lisa Toto
Diagnostics 2020, 10(1), 50; https://doi.org/10.3390/diagnostics10010050 - 19 Jan 2020
Cited by 20 | Viewed by 4345
Abstract
(1) Background: To evaluate superficial capillary plexus (SCP), deep capillary plexus (DCP), choriocapillaris (CC), perfusion density (PD), and vessel length density (VLD) in macular and near/mid periphery regions in patients with retinitis pigmentosa (RP) using widefield swept source optical coherence tomography angiography (WSS-OCTA). [...] Read more.
(1) Background: To evaluate superficial capillary plexus (SCP), deep capillary plexus (DCP), choriocapillaris (CC), perfusion density (PD), and vessel length density (VLD) in macular and near/mid periphery regions in patients with retinitis pigmentosa (RP) using widefield swept source optical coherence tomography angiography (WSS-OCTA). (2) Methods: Twelve RP patients (20 eyes) and 20 age-matched subjects (20 eyes) were imaged with the SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). Quantitative analysis was performed in the macular and peripheral regions. The main outcome measures were SCP, DCP, CC, PD, and VLD in central and peripheral areas. (3) Results: Mean visual acuity, central macular thickness, and microperimetry were significantly reduced in RP patients compared to normal subjects (p < 0.05). The perfusion density and VLD of SCP, DCP, and CC were significantly reduced in RP patients compared to normal controls both in the central and peripheral retina (p < 0.05). A significant direct correlation was found in RP patients between PD of the 1.5 mm central retina both in DCP and CC and microperimetry at 4° and 8°. (4) Conclusions: Widefield SS-OCTA shows an impairment of retinal and choroidal perfusion density and vessel length density in central and peripheral retina of RP patients. The reduction of flow features correlates with the macular function. Full article
(This article belongs to the Section Medical Imaging and Theranostics)
Show Figures

Figure 1

11 pages, 8001 KiB  
Article
Early Retinal Flow Changes after Vitreoretinal Surgery in Idiopathic Epiretinal Membrane Using Swept Source Optical Coherence Tomography Angiography
by Rodolfo Mastropasqua, Rossella D’Aloisio, Pasquale Viggiano, Enrico Borrelli, Carla Iafigliola, Marta Di Nicola, Agbéanda Aharrh-Gnama, Guido Di Marzio, Lisa Toto, Cesare Mariotti and Paolo Carpineto
J. Clin. Med. 2019, 8(12), 2067; https://doi.org/10.3390/jcm8122067 - 24 Nov 2019
Cited by 32 | Viewed by 4033
Abstract
(1) Background: The aim of this observational cross-sectional work was to investigate early retinal vascular changes in patients undergoing idiopathic epiretinal membrane (iERM) surgery using swept source optical coherence tomography angiography (SS-OCTA); (2) Methods: 24 eyes of 24 patients who underwent vitrectomy with [...] Read more.
(1) Background: The aim of this observational cross-sectional work was to investigate early retinal vascular changes in patients undergoing idiopathic epiretinal membrane (iERM) surgery using swept source optical coherence tomography angiography (SS-OCTA); (2) Methods: 24 eyes of 24 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling were evaluated pre- and postoperatively using SS-OCTA system (PLEX Elite 9000, Carl Zeiss Meditec Inc., Dublin, CA, USA). For each eye, five 6x6-mm OCTA volume scans were acquired by two observers independently. The en face images of superficial capillary plexus (SCP) were then exported to imageJ and a semi-automated algorithm was used for subsequent quantitative analysis. Perfusion density (PD), vessel length density (VLD), vessel diameter index (VDI) and vessel tortuosity (VT) of SCP were evaluated in both the parafoveal (2.5 mm diameter) and perifoveal areas (5.5 mm diameter); (3) Results: At OCTA analysis statistically significant differences were found between controls and diseased eyes for all parameters in parafoveal and perifoveal regions (p < 0.001; p < 0.05) except for perifoveal VLD. During 6-month follow up, both anatomical/perfusion and functional parameters showed a statistically significant improvement if compared to preoperative values. In detail, at one-month post vitrectomy, VLD and VT significantly changed in parafoveal region (p = 0.043; p = 0.045), while PD and VDI showed a trend of increase in both parafoveal and perifoveal region. At 6 months after surgery, PD, VLD and VT of parafoveal region significantly improved (p = 0.021, p = 0.018, p = 0.047 respectively). (4) Conclusions: SS-OCTA provides a quantitative and qualitative analysis of the superficial capillary plexus allowing for early vascular changes assessment after vitrectomy with iERM and ILM peeling. Full article
(This article belongs to the Special Issue Application of Retinal and Optic Nerve Imaging in Clinical Medicine)
Show Figures

Figure 1

Back to TopTop