Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = Bevacizumab-IRDye 800CW

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 641 KiB  
Systematic Review
Identifying Molecular Probes for Fluorescence-Guided Surgery in Neuroblastoma: A Systematic Review
by Megan Hennessy, Jonathan J. Neville, Laura Privitera, Adam Sedgwick, John Anderson and Stefano Giuliani
Children 2025, 12(5), 550; https://doi.org/10.3390/children12050550 - 24 Apr 2025
Viewed by 727
Abstract
Background/Objectives: Targeted and non-targeted fluorescent molecular probes (FMPs) can be used intra-operatively to visualise tumour tissue. Multiple probes have been clinically approved for fluorescence-guided surgery (FGS) in adult oncology, and the translation of these technologies to paediatric neuroblastoma may provide novel strategies [...] Read more.
Background/Objectives: Targeted and non-targeted fluorescent molecular probes (FMPs) can be used intra-operatively to visualise tumour tissue. Multiple probes have been clinically approved for fluorescence-guided surgery (FGS) in adult oncology, and the translation of these technologies to paediatric neuroblastoma may provide novel strategies for optimising tumour resection whilst minimising morbidity. We aimed to identify clinically approved FMPs with potential utility for FGS in neuroblastoma. Methods: A systematic review of the literature was performed in accordance with the PRISMA guidelines (PROSPERO CRD42024541623). PubMed and Web of Science databases were searched to identify studies investigating clinically approved FGS probes and/or their targets in the context of neuroblastoma. Pre-clinical and clinical studies looking at human neuroblastoma were included. The primary outcomes were that the FGS probe was tested in patients with neuroblastoma, the probe selectively accumulated in neuroblastoma tissue, or that the target of the probe was selectively over-expressed in neuroblastoma tissue. Results: Forty-two studies were included. Four were clinical studies, and the remainder were pre-clinical studies using human neuroblastoma cell lines, human tumour tissue, or xenograft models using human neuroblastoma cells. The only FMP clinically evaluated in neuroblastoma is indocyanine green (ICG). FMP targets that have been investigated in neuroblastoma include poly-ADP ribose polymerase (PARP) (targeted by PARPiFL), endothelial growth factor receptor (EGFR) (targeted by Panitumumab-IRDye800CW, Cetuximab-IRDye800CW, Nimotuzumab-IRDye800CW and QRHKPRE-Cy5), vascular endothelial growth factor receptor (VEGFR) (targeted by Bevacizumab IRDye800CW), and proteases such as cathepsins and matrix metalloproteinases that activate the fluorescent signal of FMPs, such as LUM015 and AVB-620. Of the clinical studies included, all were found to have a high risk of bias. Conclusions: ICG is the only clinically approved fluorescent dye currently used for FGS in neuroblastoma; however, studies suggest that its ability to recognise neuroblastoma tissue is inconsistent. There are several clinically approved FMPs, or FMPs in clinical trials, that are used in adult oncology surgery that have targets expressed in neuroblastoma. Further research should validate these probes in neuroblastoma to enable their rapid translation into clinical practice. Full article
(This article belongs to the Section Pediatric Surgery)
Show Figures

Figure 1

21 pages, 3912 KiB  
Article
Detection of Tumour-Targeted IRDye800CW Tracer with Commercially Available Laparoscopic Surgical Systems
by Daan J. Sikkenk, Andrea J. Sterkenburg, Iris Schmidt, Dimitris Gorpas, Wouter B. Nagengast and Esther C. J. Consten
Diagnostics 2023, 13(9), 1591; https://doi.org/10.3390/diagnostics13091591 - 29 Apr 2023
Cited by 4 | Viewed by 2806
Abstract
(1) Introduction: Near-infrared fluorescence (NIRF) combined with tumour-targeted tracers, such as bevacizumab-800CW, could aid surgical decision-making. This study explored the use of IRDye800CW, conjugated to bevacizumab, with four commercially available NIRF laparoscopes optimised for indocyanine green (ICG). (2) Methods: A (lymph node) phantom [...] Read more.
(1) Introduction: Near-infrared fluorescence (NIRF) combined with tumour-targeted tracers, such as bevacizumab-800CW, could aid surgical decision-making. This study explored the use of IRDye800CW, conjugated to bevacizumab, with four commercially available NIRF laparoscopes optimised for indocyanine green (ICG). (2) Methods: A (lymph node) phantom was made from a calibration device for NIRF and tissue-mimicking material. Serial dilutions of bevacizumab-800CW were made and ICG functioned as a reference. System settings, working distance, and thickness of tissue-mimicking material were varied to assess visibility of the fluorescence signal and tissue penetration. Tests were performed with four laparoscopes: VISERA ELITE II, Olympus; IMAGE1 S™ 4U Rubina, KARL STORZ; ENDOCAM Logic 4K platform, Richard Wolf; da Vinci Xi, Intuitive Surgical. (3) Results: The lowest visible bevacizumab-800CW concentration ranged between 13–850 nM (8–512 times diluted stock solution) for all laparoscopes, but the tracer was not visible through 0.8 cm of tissue in all systems. In contrast, ICG was still visible at a concentration of 0.4 nM (16,384 times diluted) and through 1.6–2.4 cm of tissue. Visibility and tissue penetration generally improved with a reduced working distance and manually adjusted system settings. (4) Conclusion: Depending on the application, bevacizumab-800CW might be sufficiently visible with current laparoscopes, but optimisation would widen applicability of tumour-targeted IRDye800CW tracers. Full article
Show Figures

Figure 1

16 pages, 1655 KiB  
Article
Tumor-Specific Imaging with Angiostamp800 or Bevacizumab-IRDye 800CW Improves Fluorescence-Guided Surgery over Indocyanine Green in Peritoneal Carcinomatosis
by Véronique Josserand, Claire Bernard, Thierry Michy, Mélanie Guidetti, Julien Vollaire, Jean-Luc Coll and Amandine Hurbin
Biomedicines 2022, 10(5), 1059; https://doi.org/10.3390/biomedicines10051059 - 3 May 2022
Cited by 6 | Viewed by 2933
Abstract
Complete surgical removal of lesions improves survival of peritoneal carcinomatosis and can be enhanced by intraoperative near-infrared fluorescence imaging. Indocyanine green (ICG) is the only near-infrared fluorescent dye approved for clinical use, but it lacks specificity for tumor cells, highlighting the need for [...] Read more.
Complete surgical removal of lesions improves survival of peritoneal carcinomatosis and can be enhanced by intraoperative near-infrared fluorescence imaging. Indocyanine green (ICG) is the only near-infrared fluorescent dye approved for clinical use, but it lacks specificity for tumor cells, highlighting the need for tumor-selective targeting agents. We compared the tumor-specific near-infrared fluorescent probes Bevacizumab-IRDye 800CW and Angiostamp800, which target tumor angiogenesis and cancer cells, to ICG for fluorescence-guided surgery in peritoneal carcinomatosis of ovarian origin. The probes were administered to mice with orthotopic peritoneal carcinomatosis prior to conventional and fluorescence-guided surgery. The influence of neoadjuvant chemotherapy was also assessed. Conventional surgery removed 88.0 ± 1.2% of the total tumor load in mice. Fluorescence-guided surgery allowed the resection of additional nodules, enhancing the total tumor burden resection by 9.8 ± 0.7%, 8.5 ± 0.8%, and 3.9 ± 1.2% with Angiostamp800, Bevacizumab-IRDye 800CW and ICG, respectively. Interestingly, among the resected nodules, 15% were false-positive with ICG, compared to only 1.4% with Angiostamp800 and 3.5% with Bevacizumab-IRDye 800CW. Furthermore, conventional surgery removed only 69.0 ± 3.9% of the total tumor burden after neoadjuvant chemotherapy. Fluorescence-guided surgery with Angiostamp800 and Bevacizumab-IRDye 800CW increased the total tumor burden resection to 88.7 ± 4.3%, whereas ICG did not improve surgery at all. Bevacizumab-IRDye 800CW and Angiostamp800 better detect ovarian tumors and metastases than the clinically used fluorescent tracer ICG, and can help surgeons completely remove tumors, especially after surgery neoadjuvant chemotherapy. Full article
(This article belongs to the Special Issue Advances in Therapeutic Strategies in Gynecological Malignant Tumors)
Show Figures

Figure 1

Back to TopTop