Next Article in Journal
Aqueous Adsorptive Removal of Bisphenol A Using Tripartite Magnetic Montmorillonite Composites
Previous Article in Journal
Photodegradation of Polycyclic Aromatic Hydrocarbons from Coal Tar into Mine Wastewaters and Sewage Wastewater on a Flat-Bed Photoreactor
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Carbon Footprint of the University of Patras in Greece: Evaluating Environmental Culture and Campus’ Energy Management towards 2030

by
Alexandra Vrachni
1,2,
Angeliki Christogerou
1,
George A. Thomopoulos
2,
Constantina Marazioti
1 and
George N. Angelopoulos
1,*
1
Department of Chemical Engineering, Caratheodory 1, University of Patras, 26504 Rio, Greece
2
Department of Electrical and Computer Engineering, University of Patras, 26504 Rio, Greece
*
Author to whom correspondence should be addressed.
Pollutants 2022, 2(3), 347-362; https://doi.org/10.3390/pollutants2030024
Submission received: 27 February 2022 / Revised: 7 April 2022 / Accepted: 25 April 2022 / Published: 1 August 2022

Abstract

:
Climate change has already had observable effects due to greenhouse gases (GHG) produced by human activities. Over the years, this becomes more evident as the concentration of GHG released in the atmosphere is concerningly increased as does the earth’s average temperature too. Hence, all countries and many independent organizations are taking actions to reduce the Global Warming phenomenon by setting targets for carbon dioxide emissions. The energy sector is proved to play the most important role in emissions reduction. Greece’s target for this sector is very ambitious in total transformation of energy mixture in the forthcoming years. Universities are also contributing to GHG emissions through their operations and members’ activities. Energy management at the University of Patras in Greece has already started since 2019 by installing energy meters going from manual calculations to an online system. The reliable records and accurate calculations proved as a very important action and a starting point for performing detailed analysis. In this study, there was an effort to calculate the CO2 emissions of the University of Patras using the Carbon Campus Calculator. The results showed that the students commuting is the main source of GHG emissions at the University of Patras and the purchased electricity comes next. These two factors together comprise 60.2% of the total emissions and priority should be given to reducing their footprint. Specific targets were set up for 2030 in compliance with the National Plan for Energy and Climate of Greece. Moreover, an Action Plan managing carbon and energy more efficiently and creating a strong environmental culture among the community is proposed. In the future, the university’s management team should act proactively in every change at Patras University. An assessment on the environmental impact should take place before any decision making. If necessary, extra actions should be defined in order not to deviate from the targets and new standards set.

1. Introduction

Climate change is perceptible nowadays. Extensive drought or rainfall, extreme temperatures, glacier melting, and sea level rise have been observed, all of which have a direct impact on human health, the economy, society, flora, and fauna [1]. The most significant consequence of climate change is that our planet will become uninhabitable for life in few years, and the situation is worsening by day.
In June 1992, the United Nations Framework Convention on Climate Change was signed in Rio de Janeiro, with the goal of limiting climate change [2]. The aim of this Convention was to keep greenhouse gas concentrations in the atmosphere stable at a level that would prevent hazardous anthropogenic climate intervention. The Convention also stated that the developed countries should do more to combat climate change by adopting policies and initiatives to mitigate climate change, with the goal of returning CO2 and GHG emissions to 1990 levels by the year 2000 [2]. In order to operationalize the United Nations Framework Convention, the Kyoto Protocol was established in 1997 [3], with legally binding targets for industrialized countries to limit and reduce GHG emissions in accordance with agreed individual targets. The EU and its Member States agreed to an 8% reduction compared to 1990s emissions during 2008–2012 [4]. Finally, the main target of the Paris Agreement in 2015 was to strengthen the global response to the threat of climate change by keeping the rise of average global temperature below 2 °C and to strive to limit the temperature increase even further to 1.5 °C [2]. Additionally, the aim is to reach a zero-emission state immediately after 2050 [5].
The National Energy and Climate Plan (NECP) of Greece in compliance with the Paris Agreement is the strategic plan of the Greek Government for climate and energy issues, setting out a detailed roadmap regarding the achievement of specific energy and climate targets by 2030. The NECP describes priorities and policy measures in respect to a wide range of development and economic activities intended to benefit Greek society, and therefore it is considered as a reference for the forthcoming decade [6]. Europe’s targets up to 2030 include 40–45% GHG emissions reduction in comparison to 1990s emissions, 32.5% improvement in energy efficiency and 32% share of renewable energy in total energy consumption. Policy measures include various directives to improve energy efficiency, renewable energy, electricity supply, reformation of the European Emissions Trading Scheme, as well as governance measures including national energy and climate plans [7].
Furthermore, in view of a total energy system reformation and the transition away from fossil fuels, specific initiatives are already being promoted and implemented such as the simplification and acceleration of the licensing framework in Greece, the optimal integration of Renewable Energies in the electrical network, the operation of storage systems, and the promotion of electricity use as a fuel. The target for 2030 energy consumption is set to be lower than the consumption in 2017 [8]. Additionally, energy renovation of a large number of buildings (especially of the old ones, i.e., over 30 years old) will also contribute to achieving the long-term target of neutrality by 2050 [9]. In any case, the war in Ukraine and the uncertainty of the future Russian gas supply, especially in Europe, will reshape the global energy status. Therefore, estimations and provisions of today should be reconsidered.
However, the energy sector is still playing a very important role in GHG emission inventories and is the biggest contributor of GHG emissions in the developed countries [10] due to coal-related processes (mining and combustion). Moreover, the improvement in human living standards has also influenced the CO2 emission trend over the years related to the increase in energy/electricity consumption. At the same time, total CO2e emissions per electricity produced have decreased mainly as a result of the introduction of natural gas and renewable energy sources into the electricity system (partial energy network reformation). Nevertheless, the decreasing trend for emissions in the years 2008–2018 is also strongly related to the economic recession that Greece is facing and to the mitigation actions that took place [2,11]. The availability of hydropower, on the other hand, has a considerable impact on emission levels. For instance, due to the penetration of natural gas and the high availability of hydropower, the considerable rise in electricity consumption in 2008 was not followed by a similar increase in emissions [2,12,13].
The most common technique to represent and calculate the climate change is through the use of carbon and ecological footprints. The carbon footprint estimates the amount of carbon dioxide emitted into the atmosphere as a result of a specific lifestyle or operation and contributes to global warming, whereas the ecological footprint estimates the amount of land required to support a specific lifestyle or operation by measuring the use of bio-productive space [14].
Carbon footprint considers all six greenhouse gases included in the Kyoto Protocol: Carbon Dioxide (CO2), Methane (CH4), Nitrogen Monoxide (N2O), Hydrofluorocarbons (HFCs), Perfluorocarbons (PFCs), and Sulfur Hexafluoride (SF6) and is measured in tons of carbon dioxide equivalent (tCO2e). Carbon dioxide equivalent (CO2e) allows different greenhouse gases to be comparable with each other on a calculation basis having one unit of carbon dioxide (CO2) as a unit of measurement. CO2e is calculated if we multiply the emissions of each of the six greenhouse gases with their global warming potential period of 100 years [14]. More specifically, CO2e compares emissions from all greenhouse gases in relation to CO2 which has a GWP equal to one. The carbon dioxide is set as the reference gas and the basis of comparison for all other gases. ISO Standards are well-structured tools that integrate scientific knowledge into comprehensive methodology and the best way to accomplish a goal. In this case, ISO 14060 is a group of standards related to GHG emissions and include ISO 14064-1, ISO 14064-2 ISO 14064-3, ISO 14065, ISO 14066, and ISO/TR 14069. Many companies and organizations comply to and are certified by these standards for carbon footprint control [15]. On the other hand, universities have their own carbon and ecological footprint as a result of their operations and activities, taking into consideration their multidimensional mission. Hence, several studies have been conducted at universities throughout the world calculating either their carbon or ecological footprint.
The majority of the studies that are calculating the carbon footprint found that, regarding energy consumption, electricity consumption was the biggest most significant contributor. According to the guidelines of the Intergovernmental Panel on Climate Change (IPCC), activity data and data from campus operations (i.e., liters of fuel, kWh of electricity, commuting, eating habits) were converted into tons of equivalent carbon dioxide (tCO2e) using the relevant emissions factor. The necessary input data were obtained from online questionnaires. A number of studies conducted by Suan Sunandha Rajabhat University in Thailand [16] and Tongji University in China [17] expressed their calculations per personal average carbon footprint. In the case of Thailand University [16], where students reside near the university and commute primarily by public transportation, the estimated personal footprint of 35 students was about 2.16 tCO2e/yr. In a more detailed study of Li et al. [17], the answers given by 1029 people at Tongji University resulted in approximately 3.84 tCO2e for a 9-month academic duration. Dining was found to have the biggest share of the daily activities (65%) with 34% against 15% which results from academic activities (i.e., use of computers for studying, printing and scanning) and 14% from electricity consumption in dormitories. Finally, it is proposed that to reduce the universities’ carbon footprints, an environmental campaign (e.g., use of new low energy consumption technologies, energy saving, and waste sorting) needs to be launched focusing on the right behaviors of each individual person from the academic society.
Furthermore, the Southeast European University in Tetovo (N. Macedonia) [18] not only calculated the carbon footprint using an improved campus carbon calculator for Clean Air–Cool Planet (CA-CP), but also prepared a Climate Action Plan (CAP) that prioritizes actions and sets milestones to achieve carbon neutrality. The university has an area of 20.000 m2 and 6000 students while the starting point is the year 2009. The strategy for reducing GHG emissions included the design of environmentally friendly buildings including actions such as building insulation, light bulb replacement with lower-consumption bulbs, and the installation of solar panels, water heaters, and photovoltaic systems capable of covering 28% of total load. Regarding commuting, alternative forms of transportation include carpooling, public transportation, and alternative cars such as hybrids and electric vehicles, as well as long-term usage of biofuels. In this case, the usage of video conferencing as a means of communication is utilized in order to reduce commuting as well. Finally, waste management and recycling were incorporated into the university’s policy since they not only reduce CO2 emissions but also contribute to behavior change.
The carbon footprint of Birla Institute of Technology and Science, Pilani Campus (India [19], was calculated using the life cycle analysis for the academic year 2014–2015, with the goal of serving as a model for other universities in India. For the CO2 emissions estimate, the ISO 14064 GHG protocol was used. The life cycle approach was used to quantify the emissions via Umberto NXT Universal software and Ecoinvent v 3.0 database. An offline survey was conducted to collect data regarding travel, commuting, and food habits. Other consumption and procurement data were collected from various authorities within the institute. Results showed that 50% of GHG emissions are coming from scope 2 due to high operation hours of air-conditioning systems while 48.9% are coming from scope 3 due to commuting and business travel (68%) and engineering services.
What was missing from the above-mentioned studies was a universal carbon footprint standard as analyzed by Robinson et al. [20]. In other words, a standard methodology, a consistent and transparent approach in assessing the carbon footprint. The study resulted in a four-step process by: (a) establishing organizational boundaries, (b) defining the operational limits, (c) quantifying the carbon footprint, and (d) reporting and validating the outcomes. Alternatively, scoping (which includes organizational boundaries and activities), conceptualizing, and communicating. The methodology is similar to that of ISO standards.
Later, the carbon footprint assessment of Universitat Jaume I in Spain [21] was an attempt to construct an excel file tool called CO2UNV to calculate the carbon footprint of universities and be the evolution of the Campus Carbon Calculator. The main goal of this tool was to be applicable for universities worldwide and the results among them to be comparable. All three scopes are included as well as offsets, report generation, and trend analysis. It also gives the opportunity to insert emission sources and their emission factors. Existing emission factors can be expanded and updated as well. The case of Universitat Jaume I was the verification of the tool, but its importance is indisputable because calculation is simple, flexible, accurate, and complete.
Finally, Bournemouth University [22] in the UK calculated the impact of COVID-19 lockdown on its CO2 footprint. The study covers the period from 1 April to 30 June 2020, when the campus was closed, all operations were ceased, and working/learning operations were online. The results were compared with those of previous years (2018 and 2019) in the same period using GHG conversion factors from GOV. UK. As expected, data used in 2018 and 2019 calculations (such as processes required for on-campus teaching, research and support services, staff travel using the university’s fleet, staff business travel, and staff and student commutes) were not applicable in the 2020 calculation. On the other hand, extra emission sources were added, relevant to working and studying from home (use of laptop and desktop PCs, electrical consumption for lighting, breakfast, and lunch preparation). Results revealed that the total carbon footprint was reduced by about 29% and the largest contribution was from distant working/studying. The interesting finding is that despite the lockdown, work/study from home can generate as much emissions as commuting!
In the case of Greece, the Campus University of Patras firstly calculated its carbon footprint in 2013 [23] with necessary data taken from online surveys and relevant offices. Information on energy and water consumption, as well as waste management, were also provided for each department from the University’s “Environmental Management and Sustainability Office”. It is noteworthy that the carbon footprint of an organization is the key indicator not just of its energy consumption profile, but also of its people’s behavior and culture. Moreover, it can be used as a starting point for GHG and energy reduction initiatives by developing an action plan along with a sustainable environmental culture among the university members.
Therefore, the current study aims to precisely measure the carbon footprint as well as the electricity consumption of the University of Patras collecting data that were not available in the initial effort and deriving from all existing sources of CO2 emissions. For the calculations, a “Carbon Campus Calculator” was used. To the best of the authors knowledge, till submitting the present study, no similar work was reported in the literature concerning the Campus University of Patras. The calculations are based on closing the loop by identifying applicable actions for every valid root cause, aiming to eliminate manual work and calculations, supporting automation and digitalization. In addition, it is a systematic approach to deal with fundamental organizational changes in the future management of the university. The following questions guided this study:
  • What are the exact GHG emissions of the University of Patras considering all emission sources (all scopes)?
  • Which are the biggest contributors to the carbon footprint?
  • What is the university’s ranking among local consumers in the Region of Western Peloponnese according to the outcomes?
  • Can the GHG emissions of Patras University be reduced in compliance with the NECP?
  • How feasible is it to draw up an environmental action plan for a ‘green’ university?

2. Materials and Methods

2.1. University of Patras—General Information

University of Patras was founded in November of 1964. From 2013 to 2019, the University of Western Greece and Educational Institute of Western Greece joined the University of Patras and its departments now are located in a large area in five cities of Western Greece, namely in Patras, Mesologi, Agrinio, Aigio, Pyrgos, and Amaliada [24]. In total, 30,185 pre-graduate students were registered in 2016, 1704 post-graduate students, 2051 PhD candidates, 693 professors, 232 scientific staff, and 438 administrative staff.
The University of Patras plays an important research role, as it results from internal and external evaluations receiving funding from private and state bodies. The external evaluation of the Foundation that took place in December 2015 was particularly positive for the University of Patras, characterizing it as one of the most productive universities in Greece and emphasizing the continuous effort of the administration and its academic and administrative staff to improve.
Patras campus located in Rio is the largest of all campuses and is the objective of this study. It consists of five faculties and 23 departments distributed throughout 28 buildings [24].
Commuting options are by car, bus, light rail, taxi, bikes, motorbikes, etc.
All Rio–Patras campus buildings are supplied with purchased electricity and monitored via 28 electricity online meters for electricity consumption since 2017. For heating and cooling of the buildings, air conditioners are used. Deep cooling also is used in refrigerators of the medical department.

2.2. Data Collection

Data required such as size of the university, operation and research budget, energy cogeneration, community members, campus area, energy consumption, quantity of chemicals and refrigerants, and data for waste management and recycling were taken from the university’s relevant offices.
These data were the most difficult to collect because there is no central administrative office in the university that manages that kind of information. Collecting data from every department separately made collection a difficult and time-consuming procedure.
Data concerning public transport routes by bus and light rail that serve the campus area were obtained by personal communication with KTEL Achaias SA and TRAINOSE SA, respectively. These companies provided data such as the number of routes and their distance in kilometers, type and fuel consumption for the year 2015.
Finally, data about commuting and trips the members of the Rio Campus of the University of Patras, which is information directly related to the behavior of the members individually, was obtained using a questionnaire consisting of four main parts. Part A contained general questions and demographics of the respondents. Part B contained questions about commuting to/from the university while part C questioned about travel to/from the place of permanent residence. Lastly, part D contained questions about progress over the last three years and environmental culture.
All data required, applicable for the University of Patras and available are shown below in Table 1.
After a testing period of about 10 days (28 April–9 May), the questionnaire was conducted online, via Facebook (Green Upatras profile) and the university’s site. The survey took place from 10 May 2016 up to 6 July 2016 and a total of 192 members took part in it. The survey was addressed across all university members (under-graduate/post-graduate students, PhD candidates, educative and administrative staff).

2.3. Calculations

«Carbon Campus Calculator» [25] created by New Hampshire University was selected through a decision matrix among a number of other tools. Criteria set for decision making are shown below in Table 2 with weight coefficients. The weighting method used in this study is an integrated weighting approach combining a subjective weighting method (direct rating method) based on expert opinion due to their experience, and an objective weighting method (mean weight) [26]. Two of the factors that scored highly and gave the lead to the tool was the fact that it is designed for academic institutions and that this tool was also used in previous carbon footprint calculation of the University of Patras in 2013. This facilitates comparison and exports safer conclusions about a footprint’s evolution over time. The only difference between 2013 and 2015 is that the 2013 calculation version 6 (Calculator_v6.85.xls) was used and the 2015 calculation version 8 (Calculator_v8.0.xlsm) was used with some new updates such as the development of a web-based calculator, replaced/updated references, and updated emission coefficients. Apart from those factors, the Carbon Campus Calculator is specifically designed for academic institutions, it covers almost all possible carbon sources giving the opportunity for application in every area/country by changing the relevant coefficients, generating reports and charts automatically. It is a free excel tool, costless, providing the ability to add any extra data required (customization), is easy to use, and keeps data for many years to evaluate progress and assess the trend of evolution.
Regarding completeness of carbon sources mentioned above, the World Business Council for Sustainable Development and the World Resource Institute (WBCSD/WRI) established a set of standards. These standards identify operational boundaries for institutions to ‘scope’ their sources of emissions in order to prevent “double counting” [27]. Roughly, there are three scopes [27].
  • Scope 1 includes all direct sources of GHG emissions from sources that are owned or controlled by the institution, including production of electricity, heat, or steam; transportation or materials, products, waste, community members, and emissions from unintentional leakages may occur.
  • Scope 2 includes GHG emissions from imports of electricity, heat or steam—generally associated with the generation of imported sources of energy.
  • Scope 3 includes the remaining indirect sources of GHG emissions that may result from the activities of the institution but occur from sources owned or controlled by another company such as business travel, outsourced activities, and emissions from waste generated by the institution when the GHG emissions occur at a facility controlled by another company, e.g., emissions from landfilled waste.
An effective method to prevent undesirable or wrong outcomes is to conduct a proper analysis of the situation, establish the causes of the problem, and subsequently develop a fitting solution for the situation. Conducting a cause-and-effect analysis using a fishbone diagram as shown in Figure 1, effective solutions can be found and can be implemented as the root causes of the problem have been successfully identified. For every valid cause of the diagram (shown in green), at least one action must be defined.
Action finalizing should be undertaken after completion of calculation and deployment of emissions, giving priority depending on how large the contribution to emissions every source-cause is and taking into account specific targets set for a specific period of time.

3. Results

The carbon footprint of the Rio Campus of the University of Patras was calculated at 32,882.5 tCO2e for 2015. Contribution from scope 1 was 418.1 t CO2e, 9059.5 t CO2e from scope 2 (electricity consumption), and 23,404.9 t CO2e from scope 3 as shown in Figure 2.
It is noteworthy that the largest contribution to the footprint comes from scope 3 concerning commuting, travel, recycling and waste production of the Rio Campus, and disposal.
Further deployment, contribution to CO2 emissions per emission source, helps realize and set objective and realistic goals for their reduction. The largest contribution to the carbon footprint comes from students commuting to/from the university (32.6%), the second largest source of greenhouse gas emissions is electricity (27.6%), followed by travel to/from the place of permanent residence of university members (26.7%), while staff and faculty commuting is only 7.5%. All other sources contribute at a lower rate as shown in the chart below (Figure 3).
In terms of third-level deployment in student commuting, the results obtained from an online survey, Figure 4 showed that 44% prefer the bus, 20.1% the light rail, 16.4% the car (drive alone), 13.3% carpooling, 2.7% walking, 1.8% cycling, and 1.6% motorcycling. Therefore, the majority of students use public (64.1%) and carbon-free transportation (4.5%) which amounts to almost 70%.
At this point, it is obvious that initiatives that will form the Action Plan of the University of Patras must focus primarily on reducing scope 3 emissions, particularly student commuting and electricity consumption, which account for 60.2% of the University of Patras Carbon Footprint.
Data for electricity consumption were taken from department’s individual energy meters with manual processing from the “Environmental Management and Sustainability Office” of the University of Patras. Because of the gap and constraints met and the large number of assumptions made, the University of Patras moved on by installing 28 energy meters with an online monitoring system in 2017, highlighting the importance of correct and accurate data recording.
The electricity online monitoring system was the first step for data collection and generation of a reference point of electrical consumption of the university. For every meter, a monthly trigger point is set, taking into account several criteria such as consumption during office hours (or not), working days or Sundays/holidays, seasons, estimation of weather data, building type, or other specific restrictions for every building and its operation such as electricity account per month (cost based).
These energy meters are interconnected with a central controller via the university’s data network. Data are then collected, processed, and displayed on a map (Figure 5). It is possible to track real-time electricity consumption and total statistics for all buildings, draw useful conclusions, and monitor energy prices and intervene when they reach specified thresholds.
As a result, many findings emerged such as increased lighting (electricity consumption) and air conditioning in the Conference and Cultural Center of the University of Patras. After replacement of lighting with LED systems and air conditioning with high energy class systems (better CEER and COPS energy rate), a saving of 84.103 KWh (reduction 35%) between 2016 and 2017 was achieved which means 50.4 t CO2e annual reduction and EUR 8543.19 annual cost savings [28].

4. Discussion

Expressing the results as personal carbon footprint of university members, like Suan Sunandha Rajabhat in Thailand, Tongji university in China, and Birla Institute of Technology and Science in India, the case of the Rio Campus of the University of Patras is 0.85 tCO2e/person, much lower than the result of other universities although is much higher than their total carbon footprint. The reason is that this study involves the whole campus of the University of Patras and all potential carbon sources. For Birla Institute of Technology, the personal carbon footprint is much higher (4.6 tCO2e/student) mainly due to excessive electricity consumption and high coefficient factor as coal-based electricity is around 60%. The two universities used the same methodology for carbon footprint calculation (data collection from relevant offices and survey for commuting and travel).
In the other studies [16,17,18,19], the largest contribution to the carbon footprint comes from electrical consumption (except China’s case [17] where the maximum contribution comes from eating habits), while in the University of Patras for both calculations of 2013 [23] and 2015 the largest contribution comes from the commute of university members and travel, which are classified in scope 3.
In relation to the study in Tetovo [18], Northern Macedonia, the ratios per source are similar to the University of Patras. The biggest difference is observed in electricity and is about 10%. Apart from this, we confirm that there are great similarities in the carbon footprints of the two institutions.
Comparing the two calculations of the Rio Campus of the University of Patras, the attempt of 2013 faced difficulties in data gathering (travel data, refrigerants) which had a large impact on the correct calculation carbon footprints. In the 2015 calculation, the carbon footprint of the University of Patras was almost 8 times larger than in 2013.
The University of Patras belongs to the Western Greece region. Western Greece [29] is the fourth most populated region of Greece with Patras being its capital. Patras also is the third largest city of the country generating only 5% of the National GDP. Deindustrialization has been a serious problem of the area since 1990 and as a consequence high unemployment and ageing of the population are important issues in the region.
Electricity production in the region does not come from coal. Hydropower and renewable energy systems are installed in the area in wind and solar parks. Natural gas installation still does not exist.
Regarding transportation and commuting, there is only one airport in the region (with very small traffic) and four ports. The road network is the main way of commuting.
Agriculture (directly connected with fertilizer application from an environmental point of view) is significant only in remote areas and not close to cities.
Deployment of GHG emissions per capita and region showed that they are quite low (<10 tCO2e) [30]. This is totally compatible with the low personal carbon of the University of Patras, and the largest contribution comes from scope 3 (transportation, commuting, and travel)
In 2015, the University of Patras also evaluated the environmental culture among its members via the online questionnaire. Part D of the online survey was dedicated to environmental culture. The first question asked the candidates about the form of commuting they used 3 years previously to investigate the evolution over time. The second question asked the respondents if they know how they can affect the carbon footprint and the answers were 51% “no” and 49% “yes” which, in combination with the third (last) question (51% interested in being informed, 43% that it would be good for them to know, and only 6% answered no), we are led to the conclusion that an action plan and environmental campaign need to be developed in the near future.
The main benefits following the ISO Standards [15] for Carbon Footprint Calculation are:
  • Evaluation of the carbon footprint of an organization and possibilities of its reduction.
  • Identify opportunities for energy savings and energy efficiency improvement.
  • Reduction in business, organization, or institution operating costs.
  • Presentation of reliable data.
  • Increasing the environmental awareness of its staff/members.
  • Promoting the corporate social responsibility of the company/organization and improving its corporate image.
ISO 14064 includes three parts, which can be used independently. ISO 14064-1 defines the principles and requirements for the quantification and reporting of greenhouse gas emissions of an organization. It covers the design, development, management, reporting and verification of an organization’s GHG inventory. ISO 14064-2 supports multiple types of GHG projects, sets out the principles and requirements, and provides guidance for the implementation of projects aimed at quantifying, monitoring, and reporting on greenhouse gas emissions or reductions. It covers the design of GHG projects, the identification and selection of sources, absorption and retention sites of GHG related to the project and the baseline scenario, the monitoring, quantification, documentation, and reporting of the performance of the GHG project, and the quality management of data. ISO 14064-3 sets out the principles and requirements and guides those who conduct or administer GHG inventory validation and/or verification. It can be applied to the quantification, monitoring, and reporting of the organization or greenhouse gases.
Even though ISO Standards provide guidance for GHG emissions management, only one study, the one of Birla Institute of Technology and Science Pilani, implemented it to quantify its emissions. Although ISO Standards are applicable for all organizations, implementation in educational institutions often has poor outcomes. The way of working in all studies and all universities, although is quite similar and similar to the methodology of ISO 14064, it is not strictly followed. It is in the nature of higher education to question existing standards and to open the horizons and promote knowledge and the learning process, setting new standards if needed. In fact, the opposite is common. Many standards came from studies and work undertaken by universities.
Setting targets and creating an action plan is a very important process for the success of this study. Targets should never be arbitrary but align with the targets of a larger group, organization, or community. Therefore, targets of the University of Patras should follow the targets of the country (NECP) which are in compliance with the targets of the European Union and EU’s targets comply with Global Goals.
Therefore, targets for the University of Patras can be:
  • Reduction of 42% of greenhouse gas emissions by 2030 compared to 1990, 55% compared to 2005, and then a linear reduction to make the transition to carbon neutrality in 2050 value equivalent to 10473.07t CO2e and emissions target for 2030 set to 22409.42 t CO2e.
  • Waste management for different types of materials (e.g., paper, plastic, batteries, lamps, etc.)
  • Energy from renewable energy sources should account for 35% of the total energy consumption.
  • Energy consumption in 2030 to be lower than in 2017. Energy records of 2017 showed that the energy consumption of the University of Patras was about 13 GWh.
It makes sense to prioritize actions and focus on actions that have a larger contribution in achieving the target with as little effort and cost as possible. From the 1st level deployment of carbon footprint, the target of GHG emissions reduction should be met by reducing emissions of scope 3, but deployment of the 2nd level indicates that the students commuting and electricity consumption (scope 2) are the biggest contributors. Third-level deployment shows that almost 70% of the students use public transportation and carbon freeways for commuting. The remaining 30% has quite low space for reduction and requires large efforts and costs to achieve it. Moving to the second contributor, there is large room for improvement and also the actions for achieving target (a) are common with the actions achieving targets (c) and (d) (Figure 6).
It should be mentioned that by changing the energy mixture of the country, which is an external parameter for the University of Patras, there is a reduction in its carbon footprint without any other change but keeping energy consumption constant. Therefore, the University of Patras and other institutions can benefit from NECP actions carried out in parallel with their actions. One of the main targets of NECP is the coal exemption of Greece’s energy mixture by 2028.
The Action Plan planned until 2030 and the contribution of each action to the overall carbon footprint based on the previous target setting is presented in Table 3 and Figure 7. The proposed Action Plan does not contain actions that change, limit the operation of the university, or even sacrifice facilities and amenities of its members. It includes actions that reduce CO2 emissions by keeping all the functions the same but in a more environmentally friendly way.
Many of the actions included in the Action Plan are actually smaller or bigger projects which must be prepared in detail before execution. Financial constraints in implementing the actions for CO2 emissions reduction require a selection process (which building could contribute more in terms of carbon footprint in action No 5) and a prioritization of countermeasures in creating the action plan.
Regarding energy consumption and energy efficiency actions, the use of the BEM approach should be appropriate for small campuses [31]. It is indisputable that benefits from the online monitoring system are huge but there is also room for future improvement. Trigger points of the online system should take into account real weather data of the area and not only an estimation in order to be more accurate. When a trigger point is reached, an SMS or email alarm should be generated and be sent to one or more dedicated persons without requiring a unique dedicated person and continuous checking by him, being accurate and saving time.
Installation of a photovoltaic system should be undertaken after deciding the size of the plant, taking into account the energy consumption figures of the buildings by using a feasibility study like in the case of the Technical University of Crete [32].
Actions 1 and 3 are external actions (NECP actions) but with an impact on the University of Patras’ emissions and are taken into account in the action plan.
Action plan should be finalized in 2030 but milestones have to be set in order to keep on track. Energy audits should be implemented to verify, validate, and sustain the results achieved. If a deviation is observed, countermeasures should be taken. Action plans are always dynamic.

5. Conclusions

A well-implemented action plan with detailed action steps that describe how and when these steps will be taken is of paramount importance for the University of Patras. The present study is a step forward in this direction.
Once the action plan has been approved, a responsible person should be appointed for each action. If additional investigation, study, and/or investments are required, the competent persons, services, and departments should be notified in order to ensure that the project implementation is on track. Finally, in terms of cost, the action plan should be integrated into the total budget of the university.
Apart from the correct implementation of the action plan, extra attention should be paid to sustain its results. It is undoubtable that external factors in Greece, such as political and socio-economic changes occurring, would directly affect carbon footprint. In this case, CO2 emissions will benefit as energy consumption and redundant transportation will be reduced but it will be only temporary. Once the crisis is over, the impacts will return to higher emissions. Only building a strong environmental culture among the community will ensure sustainability of the results.
Taking into consideration that green growth is part of the 2030 Agenda of the Greek Government for Sustainable Development, the University of Patras should include green growth in its current agenda.
Moreover, further research is necessary to undertake in order to study:
  • The impact of the COVID-19 pandemic.
  • The war in Ukraine and its influence on the current energy status.
These two factors strongly influence the carbon footprint performance of the University of Patras.

Author Contributions

Conceptualization, A.V., C.M. and G.N.A.; methodology, A.V. and C.M.; software, A.V. and G.A.T.; investigation, A.V. and A.C.; data curation, A.V., A.C. and G.A.T.; writing—original draft preparation, A.V.; writing—review and editing, A.V., A.C. and G.N.A.; supervision, G.N.A.; project administration, G.N.A. All authors have read and agreed to the published version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

The authors acknowledge the University of Patras for supporting this work.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Climate Change Consequences. Available online: https://ec.europa.eu/clima/climate-change/climate-change-consequences_en (accessed on 14 December 2021).
  2. National Inventory Report of Greece for Greenhouse and Other Gases for the Years 1990–2018; Ministry of the Environment and Energy: Athens, Greece, 2020.
  3. Ratification of the Kyoto Protocol to the United Nations Convention on Climate Change, Government Gazette of the Hellenic Republic, Leaf No 117, 30 May 2002. Available online: http://www.et.gr/index.php/anazitisi-fek (accessed on 26 February 2022).
  4. Approval of the National Program for Reduction of Greenhouse Gas Emissions (2000–2010) According to Article Three (Paragraph 3) of Law 3017/2002 (Government Gazette A’ 117), Government Gazette of the Hellenic Republic, Leaf No 58, 5 March 2003. Available online: http://www.et.gr/index.php/anazitisi-fek (accessed on 26 February 2022).
  5. Report of the Conference of the Parties on Its Twenty-First Session, Held in Paris from 30 November to 13 December 2015, Addendum Part two: Action Taken by the Conference of the Parties at Its Twenty-First Session, Contents Decisions Adopted by the Conference of the Parties; FCCC (United Nations Framework Convention on Climate Change): New York, NY, USA, 2016.
  6. National Energy and Climate Plan; Hellenic Ministry of Environment and Energy: Athens, Greece, 2019.
  7. Long-Term Strategy for 2050; Hellenic Republic, Ministry of the Environment and Energy: Athens, Greece, 2019.
  8. National Plan for Energy and Climate; Hellenic Republic, Ministry of the Environment and Energy: Athens, Greece, 2019.
  9. Commission Staff Working Document, Assessment of the Final National Energy and Climate Plan of Greece; Corrigendum Swd (2020) 907 Final; European Commission: Brussels, Belgium, 2020.
  10. Parker, L.; Blodgett, J. Greenhouse Gas Emissions: Perspectives on the Top 20 Emitters and Developed Versus Developing Nations; CRS Report for Congress; Congressional Research Service: Washington, DC, USA, 2008. [Google Scholar]
  11. Our World in Data. Greece: CO2 Country Profile. Available online: https://ourworldindata.org/co2/country/greece (accessed on 9 November 2021).
  12. Simões, H.M.; Seppälä, V. Climate Action in Greece, Latest State of Play, Climate Action Research and Tracking Service, Members’ Research Service PE 690.685; European Parliamentary Research Service: Brussels, Belgium, 2021. [Google Scholar]
  13. Our World in Data. Greece: Energy Country Profile. Available online: https://ourworldindata.org/energy/country/greece (accessed on 12 November 2021).
  14. DS Consulting. Available online: http://gr.dsorganic.com/services/carbon-footprinting-services/carbon-footprint/ (accessed on 2 November 2021).
  15. Wintergreen, J.; Delaney, T. ISO 14064; International Standard for GHG Emissions Inventories and Verification. International Organization for Standardization: Geneva, Switzerland, 2018.
  16. Utaraskul, T. Carbon Footprint of Environmental Science Students in Suan Sunandha Rajabhat University, Thailand. In Proceedings of the 7th World Conference on Educational Sciences (WCES-2015), Athens, Greece, 5–7 February 2015. [Google Scholar]
  17. Li, X.; Tan, H.; Rackes, A. Carbon footprint analysis of student behavior for a sustainable university campus in China. J. Clean. Prod. 2015, 106, 97e108. [Google Scholar] [CrossRef]
  18. Spirovski, D.; Abazi, A.; Iljazi, I.; Ismaili, M.; Cassulo, G.; Venturin, A. Realization of a low emission university campus through the implementation of a climate action plan. In Proceedings of the WCES 2012, Barcelona, Spain, 1–4 February 2012. [Google Scholar]
  19. Sangwan, K.S.; Bhakar, V.; Arora, V.; Solanki, P. Measuring carbon footprint of an Indian university using life cycle assessment. In Proceedings of the 25th CIRP Life Cycle Engineering (LCE) Conference, Copenhagen, Denmark, 30 April–2 May 2018. [Google Scholar]
  20. Robinson, O.J.; Tewkesbury, A.; Kemp, S.; Williams, I.D. Towards a universal carbon footprint standard: A case study of carbon management at universities. J. Clean. Prod. 2017, 172, 4435–4455. [Google Scholar] [CrossRef]
  21. Valls-Val, K.; Bovea, M.D. Carbon Footprint Assessment Tool for Universities: CO2UNV; Elsevier B.V.: Amsterdam, The Netherlands, 2021. [Google Scholar]
  22. Filimonau, V.; Archer, D.; Bellamy, L.; Smith, N.; Wintrip, R. The Carbon Footprint of a UK University during the COVID-19 Lockdown; Elsevier B.V.: Amsterdam, The Netherlands, 2020. [Google Scholar]
  23. Diamantopoulou, M.; Marazioti, K.; Angelopoulos, G.N. CO2 Footprint of University of Patras; University of Patras: Patras, Greece, 2013. [Google Scholar]
  24. University of Patras. Available online: https://www.upatras.gr/upatras/about/profile/ (accessed on 16 November 2021).
  25. University of New Hampshire. University of New Hampshire Campus Carbon Calculator v8.0, ©2001–2015. Available online: http://www.sustainableunh.unh.edu (accessed on 26 February 2022).
  26. Odu, G.O. Weighting Methods for Multi-Criteria Decision Making Technique. J. Appl. Sci. Environ. Manag. 2019, 23, 1449–1457. [Google Scholar] [CrossRef] [Green Version]
  27. Clean Air Cool Planet, Conducting a Campus Greenhouse Gas Emissions Inventory on Your Campus. CAMPUS CARBON CALCULATOR User’s Guide Including Instructions and Documentation for CA-CP Calculator v5.0, ©2006. Available online: http://www.siue.edu›sos›CACP_UserGuide (accessed on 19 November 2021).
  28. Thomopoulos, A.G. Energy Capture, Forecast and Saving of the Energy Consumption of Department Buildings on the Campus of the University of Patras. Master’s Thesis, University of Patras, Patras, Greece, 2018. [Google Scholar]
  29. OECD. Regional Policy for Greece Post-2020; Regional Profiles; OECD: Paris, France, 2020. [Google Scholar]
  30. OECD, Greece. Progress in the Net Zero Transition; Regional Outlook 2021—Country Notes; OECD: Paris, France, 2021. [Google Scholar]
  31. Nagpal, S.; Hanson, J.; Reinhart, C. A framework for using calibrated campus-wide building energy models for continuous planning and greenhouse gas emissions reduction tracking. Appl. Energy 2019, 241, 82–97. [Google Scholar] [CrossRef]
  32. Hasapis, D.; Savvakis, N.; Tsoutsos, T.; Kalaitzakis, K.; Psychis, S.; Nikolaidis, N.P. Design of large scale prosuming in Universities: The solar energy vision of the TUC campus. Energy Build. 2017, 141, 39–55. [Google Scholar] [CrossRef]
Figure 1. Fishbone diagram.
Figure 1. Fishbone diagram.
Pollutants 02 00024 g001
Figure 2. University of Patras carbon footprint per scope.
Figure 2. University of Patras carbon footprint per scope.
Pollutants 02 00024 g002
Figure 3. Detailed contribution of every factor to the University of Patras’s carbon footprint.
Figure 3. Detailed contribution of every factor to the University of Patras’s carbon footprint.
Pollutants 02 00024 g003
Figure 4. Student commuting deployment.
Figure 4. Student commuting deployment.
Pollutants 02 00024 g004
Figure 5. University of Patras’s electricity map. There are nine submetering stations (legend on the left) that track the real-time electricity consumption of all buildings in the campus. The data are controlled centrally from the university’s energy network.
Figure 5. University of Patras’s electricity map. There are nine submetering stations (legend on the left) that track the real-time electricity consumption of all buildings in the campus. The data are controlled centrally from the university’s energy network.
Pollutants 02 00024 g005
Figure 6. Waterfall diagram per scope.
Figure 6. Waterfall diagram per scope.
Pollutants 02 00024 g006
Figure 7. Waterfall diagram of the University of Patras carbon footprint.
Figure 7. Waterfall diagram of the University of Patras carbon footprint.
Pollutants 02 00024 g007
Table 1. Data used for the University of Patras carbon footprint calculation.
Table 1. Data used for the University of Patras carbon footprint calculation.
ScopeEmission Source CategoryEmission Source Sub-CategoryApplicable for University of Patras (Y/N)Data Available (Y/N)
Scope 1On-Campus Stationary SourcesOn-Campus Cogeneration PlantsYY
Other On-Campus Stationary
Sources
YY
Direct Transportation SourcesUniversity FleetYY
Refrigerants and ChemicalsRefrigerants and ChemicalsYN
Agriculture SourcesFertilizer ApplicationNN
Animal HusbandryNN
Scope 2Purchased Electricity, Steam and Chilled WaterElectricityYY
SteamNN
Chilled WaterNN
Scope 3CommutingFaculty/Staff CommutingYY
Student CommutingYY
Directly Financed Outsourced TravelAir TravelYY
OtherYY
Study Abroad TravelStudy Abroad TravelYY
Student Travel to/from HomeStudent Travel to/from HomeYY
Solid WasteIncinerated Waste (not used for on-campus power)NN
Landfilled WasteYY
WastewaterSeptic SystemNN
Central Treatment SystemYY
PaperUncoated FreesheetYY
Paperboard: Uncoated Bleached KraftYY
OffsetsOffsets with AdditionalityYY
Non-Additional Renewable Energy Certificates (RECs)YY
Table 2. Criteria for selecting the calculation tool.
Table 2. Criteria for selecting the calculation tool.
CriteriaWeight FactorScore Range
1Data completeness—field coverage51–5
2Applicability to the Rio Campus of the University of Patras—geographical boundaries2Y:2 N:0
3Access and possibility for coefficient changes30–5
4Chart and report generating21–5
5Online tool/xls file1Online: −2, xls:1
6Subscription—cost of use−1Y:1 N:0
7Ability to add data (customization)3Y:1–2, N:0
8Release date—version update41–5: 2, 6–10: 1
9Trend of data and calculations2Y:1 N:0
10Previous use in terms of comparison3Y:1 N:0
11User friendly31–3
Table 3. University of Patras Action Plan for carbon footprint reduction.
Table 3. University of Patras Action Plan for carbon footprint reduction.
Action NumberDescription of ActionCarbon Footprint Reduction (tCO2e)Target to AchieveScope
1Change in Greece’s energy mixture (energy from coal = 0, energy from renewable energy sources = 35%)5083.73a, c2
2Total electricity consumption < 13 GWh
• LED lights
• Solar heaters for hot water (laboratories and dormitories)
600a, c, d2
3Use of alternative fuels3703.57a3
4Environmental campaign300a, b, c1, 2, 3
5Green buildings – energy renovation
(2 buildings up to 2030)
208.2a, b, c, d2
6Reduce the use of paper (50%) through the use of electronic media and paper recycling (80%)57.04a, b3
7Installation of PV panels (600 kWh for external lighting and 100 kWh for electronic device charging stations and safety bars for access control)4.5a, c, d2
8Tree planting87aOffset
9Carbon footprint calculation every 2 years100a1, 2, 3
10Survey conduction every 5 years200a3
11Refrigerants replacement with others with low GWP184.8a3
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Vrachni, A.; Christogerou, A.; Thomopoulos, G.A.; Marazioti, C.; Angelopoulos, G.N. Carbon Footprint of the University of Patras in Greece: Evaluating Environmental Culture and Campus’ Energy Management towards 2030. Pollutants 2022, 2, 347-362. https://doi.org/10.3390/pollutants2030024

AMA Style

Vrachni A, Christogerou A, Thomopoulos GA, Marazioti C, Angelopoulos GN. Carbon Footprint of the University of Patras in Greece: Evaluating Environmental Culture and Campus’ Energy Management towards 2030. Pollutants. 2022; 2(3):347-362. https://doi.org/10.3390/pollutants2030024

Chicago/Turabian Style

Vrachni, Alexandra, Angeliki Christogerou, George A. Thomopoulos, Constantina Marazioti, and George N. Angelopoulos. 2022. "Carbon Footprint of the University of Patras in Greece: Evaluating Environmental Culture and Campus’ Energy Management towards 2030" Pollutants 2, no. 3: 347-362. https://doi.org/10.3390/pollutants2030024

APA Style

Vrachni, A., Christogerou, A., Thomopoulos, G. A., Marazioti, C., & Angelopoulos, G. N. (2022). Carbon Footprint of the University of Patras in Greece: Evaluating Environmental Culture and Campus’ Energy Management towards 2030. Pollutants, 2(3), 347-362. https://doi.org/10.3390/pollutants2030024

Article Metrics

Back to TopTop