Next Article in Journal
Deployment of Mobile Air Sensing Network for Urban Air Pollution Monitoring in Hong Kong
Previous Article in Journal
Voltammetric Electronic Tongue for the Resolution of Ternary Nitrophenol Mixtures
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

SPR Chemosensors Based on D-Shaped POFs and MIPs: Investigation on Optimal Thickness of the Buffer Layer †

1
Department of Industrial and Information Engineering, University of Campania Luigi Vanvitelli, 81031 Aversa, Italy
2
RSE spa, Via Raffaele Rubattino, 20134 Milano, Italy
3
Department of Chemistry, University of Pavia, Via Taramelli 12, 27100 Pavia, Italy
*
Authors to whom correspondence should be addressed.
Presented at the 5th International Symposium on Sensor Science (I3S 2017), Barcelona, Spain, 27–29 September 2017.
Proceedings 2017, 1(8), 816; https://doi.org/10.3390/proceedings1080816
Published: 13 December 2017
A comparative analysis of different optical sensing platforms, designed for chemical applications and based on molecularly imprinted polymers (MIPs), is presented. The optical platforms are based on surface plasmon resonance (SPR) in a D-shaped plastic optical fiber (POF), with a buffer layer between the exposed POF core and the thin gold film (60 nm thick). These optical platforms are realized by removing the cladding of POFs along half circumference, spin coating a buffer layer on the exposed core (with different velocities to obtain different thicknesses), and finally sputtering a thin gold film. The buffer layer proposed in this analysis is the photoresist Microposit S1813, with a refractive index greater than the one of the POF core. This photoresist buffer layer is required in order to increase the performances of the sensor.
We intend to show how, in the refractive index range used for chemical applications based on MIPs, the sensor’s performances change when the thickness of the photoresist layer changes. The results show that when the thickness of the photoresist layer decreases, the sensor’s sensitivity increases. The experimental results are congruent with the numerical studies and this analysis is instrumental for chemical applications.

Conflicts of Interest

The authors declare no conflict of interest.
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Cennamo, N.; Maria, L.D.; Pesavento, M.; Mattiello, F.; Chemelli, C.; Zeni, L. SPR Chemosensors Based on D-Shaped POFs and MIPs: Investigation on Optimal Thickness of the Buffer Layer. Proceedings 2017, 1, 816. https://doi.org/10.3390/proceedings1080816

AMA Style

Cennamo N, Maria LD, Pesavento M, Mattiello F, Chemelli C, Zeni L. SPR Chemosensors Based on D-Shaped POFs and MIPs: Investigation on Optimal Thickness of the Buffer Layer. Proceedings. 2017; 1(8):816. https://doi.org/10.3390/proceedings1080816

Chicago/Turabian Style

Cennamo, Nunzio, Letizia De Maria, Maria Pesavento, Francesco Mattiello, Cristina Chemelli, and Luigi Zeni. 2017. "SPR Chemosensors Based on D-Shaped POFs and MIPs: Investigation on Optimal Thickness of the Buffer Layer" Proceedings 1, no. 8: 816. https://doi.org/10.3390/proceedings1080816

APA Style

Cennamo, N., Maria, L. D., Pesavento, M., Mattiello, F., Chemelli, C., & Zeni, L. (2017). SPR Chemosensors Based on D-Shaped POFs and MIPs: Investigation on Optimal Thickness of the Buffer Layer. Proceedings, 1(8), 816. https://doi.org/10.3390/proceedings1080816

Article Metrics

Back to TopTop