Next Article in Journal
Analysis of SPR Sensors in d-Shaped POF Realized by Hand and Mechanical Polishing
Previous Article in Journal
Cryptographic Protocols in Wireless Sensor Networks: A Critical Review
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Selenocystine Modified Screen-Printed Carbon Electrode as an Alternative Sensor for the Voltammetric Determination of Metal Ions †

Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, University of Barcelona, 08028 Barcelona, Spain
*
Author to whom correspondence should be addressed.
Presented at the 5th International Symposium on Sensor Science (I3S 2017), Barcelona, Spain, 27–29 September 2017.
Proceedings 2017, 1(8), 751; https://doi.org/10.3390/proceedings1080751
Published: 29 November 2017
Heavy metals are present in the environment from both natural and anthropogenic sources. Their bioaccumulation and persistence constitutes a serious threat to human health, demanding suitable methods for heavy metal monitoring. In this sense, anodic stripping voltammetry is especially appropriate for measuring trace metals. Conventionally, stripping techniques were connected to the use of mercury-based electrodes. Nevertheless, concerns about mercury toxicity have led to focus on the development of more environmentally friendly alternatives such as chemically modified electrodes (CME). The commercial availability of screen-printed electrodes (SPE) has largely expanded the field of application of modified electrodes as substitutes for mercury.
The molecule immobilization procedure is a key aspect in the design of CMEs. Particularly, the molecule immobilization based on aryl diazonium salt anchored on the electrode surface has proven to be a suitable approach for the development of sensors.
This work focuses on the development of a selenocystine modified sensor via electrografting on a screen-printed carbon-nanofiber substrate (SeCyst-SPCNFE). This sensor was applied to the determination of Cd(II) and Pb(II) and compared to a sensor modified with l-Cystine (Cyst-SPCNFE) providing a better analytical performance. Finally, the applicability of SeCyst-SPCNFE was tested in a wastewater sample.

Share and Cite

MDPI and ACS Style

Serrano, N.; Puy-Llovera, J.; Pérez-Ràfols, C.; Díaz-Cruz, J.M.; Ariño, C.; Esteban, M. Selenocystine Modified Screen-Printed Carbon Electrode as an Alternative Sensor for the Voltammetric Determination of Metal Ions. Proceedings 2017, 1, 751. https://doi.org/10.3390/proceedings1080751

AMA Style

Serrano N, Puy-Llovera J, Pérez-Ràfols C, Díaz-Cruz JM, Ariño C, Esteban M. Selenocystine Modified Screen-Printed Carbon Electrode as an Alternative Sensor for the Voltammetric Determination of Metal Ions. Proceedings. 2017; 1(8):751. https://doi.org/10.3390/proceedings1080751

Chicago/Turabian Style

Serrano, Núria, Jaume Puy-Llovera, Clara Pérez-Ràfols, José Manuel Díaz-Cruz, Cristina Ariño, and Miquel Esteban. 2017. "Selenocystine Modified Screen-Printed Carbon Electrode as an Alternative Sensor for the Voltammetric Determination of Metal Ions" Proceedings 1, no. 8: 751. https://doi.org/10.3390/proceedings1080751

Article Metrics

Back to TopTop