Next Article in Journal
Room Temperature Chemoresistive Gas Sensor Based on Organic-Functionalized Graphene Oxide
Previous Article in Journal
Find the Gap: Project MOEEBIUS, a Holistic Energy Performance Optimization Framework
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Abstract

Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy †

by
Dionisia Ortiz-Aguayo
and
Manel del Valle
*
Department of Chemistry, Universitat Autònoma de Barcelona, Edifici Cn, 08193 Bellaterra (Barcelona), Spain
*
Author to whom correspondence should be addressed.
Presented at the 5th International Symposium on Sensor Science (I3S 2017), Barcelona, Spain, 27–29 September 2017.
Proceedings 2017, 1(8), 734; https://doi.org/10.3390/proceedings1080734
Published: 13 December 2017
This research develops aptasensors for Lysozyme protein detection [1] using the Electrochemical Impedance Spectroscopy (EIS) technique which is simple, low-cost and follows the rapid high-sensitivity transduction principle to monitor biosensing events that take place at the surface of an electrode; the EIS technique is also capable of showing responses at a very low concentration level [2]. To achieve the main objective of this work, electrodes based on Graphite–Epoxy Composite (GECs) were constructed. The chosen immobilization technique was covalent bond using carbodiimide chemistry; for this purpose, carboxylic moieties were first generated on the graphite by electrochemical grafting.
The detection is performed using [Fe(CN)6]3−/[Fe(CN)6]4− as the redox marker. After recording the frequency response, values are fitted to its electric model; for this purpose, a nonlinear least-squares regression protocol with complex arithmetic using Z-view is performed using the principles of the equivalent circuit. The aptasensor showed a linear response range of 0.25 μM–5 μM for Lysozyme and a limit of detection (LOD) of 0.19 μM. The sensitivity of the method established was 0.0889 μM−1 in relative charge transfer resistance values.
The aptasensor can be regenerated by breaking the complex formed between the aptamer and Lysozyme using 2.0 M NaCl solution at 42 °C, showing its operation for five cycles. The main proteins’ interference response, such as bovine serum albumin (BSA) and Cytochrome c (Cyt c), has also been characterized. To finally verify the performance of the developed aptasensor, it was applied to wine analysis. The developed aptasensors indicate their suitability given that they can detect Lys in a complex matrix such as wine obtaining recovery yields of 77%.

References

  1. McDonald, J.R. Impedance Spectroscopy; John Wiley: New York, NY, USA, 1987. [Google Scholar]
  2. Vasilescu, A.; Wang, Q.; Li, M.; Boukherroub, R.; Szunerits, S. Aptamer-Based Electrochemical Sensing of Lysozyme. Chemosensors 2016, 4, 20. [Google Scholar] [CrossRef]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Ortiz-Aguayo, D.; Valle, M.d. Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy. Proceedings 2017, 1, 734. https://doi.org/10.3390/proceedings1080734

AMA Style

Ortiz-Aguayo D, Valle Md. Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy. Proceedings. 2017; 1(8):734. https://doi.org/10.3390/proceedings1080734

Chicago/Turabian Style

Ortiz-Aguayo, Dionisia, and Manel del Valle. 2017. "Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy" Proceedings 1, no. 8: 734. https://doi.org/10.3390/proceedings1080734

APA Style

Ortiz-Aguayo, D., & Valle, M. d. (2017). Label-Free Aptasensor for Lysozyme Detection Using Electrochemical Impedance Spectroscopy. Proceedings, 1(8), 734. https://doi.org/10.3390/proceedings1080734

Article Metrics

Back to TopTop