Article

Design and Optimization of an Anthropomorphic Robot Finger

The State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150008, China
*
Author to whom correspondence should be addressed.
Biomimetics 2025, 10(3), 170; https://doi.org/10.3390/biomimetics10030170
Submission received: 15 January 2025 / Revised: 2 March 2025 / Accepted: 9 March 2025 / Published: 11 March 2025
(This article belongs to the Special Issue Human-Inspired Grasp Control in Robotics)

Abstract

:
The coupled-adaptive underactuated finger offers two motion modes: pre-grasping and self-adaptive grasping. It can execute anthropomorphic pre-grasp motions before the proximal phalanx contacts an object and transitions to adaptive enveloping once contact occurs. The key to designing a coupled-adaptive finger lies in its configuration and parameter, which are crucial for achieving a more human-like design for the prosthetic hand. Thus, this paper proposes a configuration topology and parameter optimization design method for a three-joint coupled-adaptive underactuated finger. The finger mechanism utilizes a combination of prismatic pairs and a compression spring to facilitate the transition between coupled motion and adaptive motion. This enables the underactuated finger to perform coupled movements in free space and adaptive grasping motions once it makes contact with an object. Furthermore, this paper introduces a finger linkage parameter optimization method that takes the joint motion angles and overall dimensions as constraints, aiming to linearize the joint coupling motion ratios as the primary optimization objective. The design method proposed in this paper not only presents a novel linkage mechanism but also outlines and compares its isomorphic types. Furthermore, the optimization results provide an accurate maximum motion value for the finger.

1. Introduction

The exceptional manipulation abilities of human hands are not only reflected in their dexterity, but also in their mechanical compliance [1]. The human hand elastic drive system, consisting of bones, joints, and ligaments, can not only generate the desired motion trajectory but also automatically adjust the applied force and stiffness in response to changes in the surrounding environment and the object being manipulated. This adaptability is the key factor enabling the human hand to perform dexterous, stable, and compliant operations [2]. As a functional rehabilitation aids for amputees, the prosthetic hands are designed to restore their grasping and manipulative abilities [3]. Compared to general-purpose robotic hands, prosthetic hands demand a higher level of anthropomorphic design in terms of size, weight, control complexity, and motion patterns. Designing a prosthetic hand mechanism to reproduce the operation function of a human hand, the commonly used design philosophies can be summarized as follows:
(1) Fewer Actuators. The complexity of an anthropomorphic prosthetic hand’s control system is directly proportional to the number of actuators it employs. A higher number of actuators implies more complex control inputs, whereas fewer actuators reduce the control difficulty for the mechanical system. To help individuals with disabilities make better use of the limited myoelectric signals from their residual limbs, it is crucial to use as few actuators as possible in a mechanical prosthetic hand. Reducing the number of actuators not only lowers control complexity but also decreases the weight and overall cost of the hand [4]. (2) High Integration. It typically adopts a highly integrated mechatronic design approach that combines mechanical and control systems, leading to a more compact internal layout, smaller overall size, and lighter weight [5]. Furthermore, the anthropomorphic appearance and dimensions align closely with ergonomic requirements, enhancing both comfort and usability while also supporting modular design for easier maintenance and upgrades [6,7,8,9,10].
(3) Modularization. Modular design effectively reduces the weight of the prosthetic hand structure, enhances the interchangeability of parts, reduces manufacturing costs, and simplifies assembly complexity [11,12,13].
(4) Mechanical compliance. A transmission system with mechanical adaptability can quickly adjust the mechanism configuration to adapt to the grasped object without the intervention of sensing and feedback control. Mechanical compliance can effectively increase the level of mechanical intelligence of the prosthetic hand and improve the passive response ability of the prosthetic hand to the manipulated object [14,15,16,17].
(5) Extensive range of motion. A sufficiently large motion range can effectively enhance the grasping capability of the prosthetic hand [18,19].
To date, the prosthetic hands have primarily employed underactuated mechanisms as the core component of their transmission systems to achieve the above features [20,21,22]. The underactuated mechanism leverages the energy conversion characteristics of energy storage elements, endowing prosthetic hands with an embedded mechanically intelligent structure. This enables the prosthetic hand to quickly respond to external environmental disturbances and achieve adaptive enveloping grasps of objects at the hardware level without the need for intervention from the control system. However, due to the high degree of freedom, compact structure, and complexity of the human hand, most mechanical hands cannot perfectly replicate its functions. To address these challenges, researchers have explored the following approaches in prosthetic hand system design:
(1) Independent design of the thumb and modular design of the other four fingers. The thumb is designed separately due to its more complex trapezium bone structure compared to the other four fingers. Whether grasping, lifting, pushing, pulling, or supporting objects, multiple degrees of freedom in the thumb are required for these actions. As a result, most anthropomorphic prosthetic hands feature a uniquely designed thumb, where the abduction–adduction and flexion–extension motions are independently driven by separate motors. The other four fingers, in contrast, are designed as modular units with identical structures and functions [23,24].
(2) Reduce the degrees of freedom of the metacarpophalangeal joint (MCP joint) of the fingers. The MCP joint of the human hand is a dual-degree-of-freedom system. In addition to the bending degree of freedom, it also has the lateral freedom degree, making the operating space of the human hand fingers a three-dimensional space. In order to simplify the structure of the prosthetic hand, enhance the reliability of the prosthetic hand, and reduce the cost of the prosthetic hand, the MCP joint of the prosthetic hand mainly retains the bending degree of freedom while omitting the lateral freedom degree, retaining the configuration of three knuckles and three joints [25].
(3) Coupling-adaptive design: Human fingers can quickly approach the grasped object through pre-grasping movements in free space and then adjust the muscles to complete the grasping operation of complex-shaped objects. The pre-grasping refers to the proportional coupling of the three joints in human or robotic fingers before it makes contact with an object. In the design of underactuated fingers, this pre-grasp mode [26] is also called cage-grasp [27] or coupling-adaptive grasp [28,29], which has three advantages: (a) it can simulate the pre-bending movement of human fingers; (b) it can approach the manipulated object more quickly and complete the bending movement; (c) it can enable the underactuated fingers to effectively constrain the grasped object within the operating space, making it impossible for them to escape the closed space created by the underactuated prosthetic hand, and then adjust the finger configuration and joint angle until a stable grasp of the manipulated object is completed.
Despite the fact that lots of efficient attempts and efforts have been made for the prostheses design, indeed, it is a challenge to effectively integrate coupling-adaptive mechanisms into prosthetic hands with an anthropomorphic size, ensuring both robust pre-grasp and self-adaptive functionalities while maintaining a compact and reliable structure. Therefore, this paper proposes a novel compact design method for a coupled-adaptive finger transmission chain. To enable the finger to simultaneously perform coupled motion and adaptive decoupling motion, the study focuses on three key elements: the position of the driving linkage, the position of the decoupling joint, and the placement of elastic components. The design of the spring is a crucial element in underactuated finger mechanisms [30]. In linkage-based underactuated fingers, the position of the driving link directly affects the driving force and the complexity of the integrated design. Additionally, the most directly influential joint affecting the underactuated motion pattern is the decoupling joint. Therefore, for the coupled-adaptive mechanism proposed in this paper, these three aspects have been chosen as the core design criteria. The traditional cross-coupled four-bar mechanism can execute humanoid coupled motion without adaptive capacities [31]. On this basis, a topological analysis of the traditional cross-coupled four-bar mechanism is conducted to design an underactuated finger mechanism capable of replicating the grasping functionality of a human hand. Furthermore, a statistical method is employed to optimize the mechanism’s dimensional parameters. Using the initial and final positions of the finger configuration as boundary conditions, the optimization aims to linearize the transmission relationship between joint angles. This ensures that the underactuated finger can reach its absolute final position while maintaining effective performance.
This research expands on our previous work [32,33]. But there exist some significant differences. The previous works primarily focused on introducing stability analysis methods for coupled-adaptive fingers and biomechatronic integration design approaches for prosthetic hands. The main contributions of this paper are as follows: (1) Proposing a topological design method for coupled-adaptive linkage mechanisms, accompanied by a comparative analysis of this class of isomorphic fingers mechanisms; (2) Developing a parameter optimization design method for this finger linkage mechanism, using initial and final positions as constraint conditions.
The rest of this article is organized as follows. First, Section 2 elaborates the mechanism design of the coupled-adaptive finger. Then, Section 3 introduces the parameter optimization design method for this finger linkage mechanism. Finally, Section 4 concludes this article.

2. Coupled-Adaptive Finger Mechanism Design

The transmission systems of underactuated fingers commonly use mechanisms such as cables [34], gears [35], and linkages [36]. Cable-driven underactuated systems typically incorporate pulleys paired with elastic components as decoupling mechanisms for adaptive motion. The reverse motion of the finger is achieved through the potential energy stored in the elastic elements. The main advantage of the cable mechanism lies in its flexibility, enabling more adaptable motion transmission within the finger. However, its drawbacks include the difficulty of securing the cable, as it tends to slip off the drive or guide pulleys. This often necessitates the use of complex limiters and pre-tensioning mechanisms [37,38], resulting in reduced reliability. Gear mechanisms in underactuated prosthetic hand transmission systems offer smooth motion transmission but require significant space, entail high manufacturing costs, and demand precise assembly and alignment. These factors limit their suitability for integrated designs in anthropomorphic prosthetic hands. In comparison, linkage mechanisms generally employ geometrically constrained lower-pair joints, which provide surface contact, lower contact pressure, higher load capacity, and ease of manufacturing. Furthermore, linkage mechanisms offer high stiffness, bidirectional driving, and ease of achieving predefined motion trajectories [39,40]. In summary, this paper adopts planar linkage mechanisms to design the mechanical transmission system for underactuated fingers.
The planar four-bar mechanism is often used to design adaptive anthropomorphic fingers [41]. The cross-coupled four-bar mechanism is commonly chosen for designing coupled fingers [42]. As shown in Figure 1, traditional coupled finger designs usually place the driving source at the metacarpophalangeal (MCP) joint. The actuators directly drive the rotation of the proximal phalanx (AF), while the coupled linkages enable the other phalanges to execute anthropomorphic pre-grasping motions. Therefore, this study uses the cross-coupled four-bar mechanism as the basic unit for type synthesis to design a novel underactuated finger structure, meeting the functional and adaptive requirements of underactuated prosthetic hands.
The type synthesis of mechanisms involves arranging and combining a specified number of components and kinematic pairs based on the required degrees of freedom. This process generates various possible mechanism types, from which the optimal topology is selected by analyzing and identifying the one that best meets the design objectives.
To enable the finger to achieve adaptive decoupling motion, this study focuses on three key elements: the position of the driving linkage, the location of the decoupling joint, and the placement of the elastic components. These three elements form the core of the underactuated coupled-adaptive finger mechanism. The traditional cross-coupled four-bar mechanism (Figure 2a) is deconstructed and reconfigured to create new topological structures. These structures enable underactuated finger transmission systems to perform both coupled and adaptive motion modes, as shown in Figure 2b–h. Among these, Figure 2b–g represent a seven-bar kinematic chain, while Figure 2h represents a five-bar kinematic chain. To clearly describe the different types of topological structures, the corresponding topologies shown in Figure 2 are labeled with the bold identifiers SA to SH throughout the text.
  • The SA topological structure represents the traditional configuration of a cross-coupled four-bar mechanism.
  • The SB topological structure is created by embedding a prismatic joint (D) into the coupling linkage (CE) of the SA topological structure. This modification allows the coupling four-bar mechanism to perform decoupled motions under specific conditions. Building on this, a closed kinematic chain (A-B-D-C-A) is added, forming a composite joint (D) that combines a prismatic joint and a revolute joint. An elastic component is installed at the composite joint (D), and the driving linkage is relocated from link AF to link AB. This creates a new seven-bar mechanism capable of performing coupled-adaptive motion.
  • The SC topological structure is developed from the SB structure by merging joint D and joint E into a composite joint, resulting in a new seven-bar mechanism. Compared to the SB structure, the composite joint E in the SC structure combines two revolute joints and is simpler to implement structurally.
  • The SD topological structure is an isomorphic variant of the SC structure. The key difference is the placement of the elastic component, which is located at joint B in the SD structure. Prismatic joints are generally suitable for linear elastic components, such as tension–compression elements, while revolute joints are better suited for torque-based elastic components. Therefore, different topological structures can be chosen based on specific design requirements.
  • The SE topological structure is derived from the SB structure by relocating the driving position from joint A to joint C.
  • The SF topological structure is based on the SE structure, with joint D and joint E merged into a composite joint.
  • The SG topological structure is based on the SF structure, by relocating the elastic component from the prismatic joint D to joint B.
  • The SH topological structure simplifies the SG structure by removing the adaptive linkage CE and adding a mechanical limiter at joint B to replace the coupling constraint function of linkage CE. This results in a new five-bar mechanism, achieving a more streamlined design.
Additionally, the elastic component in the SB~SH topological structures can be repositioned to joint F, forming new isomorphic variants labeled SBI~SHI. These variants are not illustrated in this paper for brevity.
As shown in Table 1, the SB~SH topological structures can be categorized into three groups for discussion:
(1) Position of the Driving Linkage
In the SB–SD topology, the driving link AB rotates around joint A, whereas in the SE–SH topology, the driving link CB rotates around joint C. The key difference lies in the behavior during the coupled motion phase, which occurs before the adaptive motion begins. In the SB–SD structures, the angular displacement of the revolute joint B starts to increase, while the translational offset of the prismatic joint D remains unchanged. In contrast, in the SE–SH structures, both the angular displacement of joint B and the translational offset of joint D remain constant.
As a result, the elastic component in the SE–SH structures, whether installed at joint B or D, maintains a constant spring force before adaptive motion begins. Additionally, having the driving linkage rotate around joint A in the SB–SD structures is advantageous for reducing the thickness of the finger, which facilitates the integrated design of the finger mechanism.
(2) Position of the Composite Joint
In the SC, SD, SF, SG, and SH topological structures, the force transmission point is located at the composite joint E, whereas in the SB and SE structures, the transmission point is at the composite joint D. Comparing these two categories, the pressure angle of the transmission linkage BE and the linkage CE in the SB and SE structures is larger, while the transmission angle is smaller. Conversely, the SC, SD, SF, SG, and SH structures feature a smaller pressure angle and a larger transmission angle between the transmission rod BD and the linkage CE. Therefore, the SB and SE topologies are more advantageous for efficient force transmission between the mechanism components.
(3) Spring Placement
In the SB, SC, SE, and SF topological structures, the elastic components are installed at the prismatic joint D. In contrast, the SD, SG, and SH structures have the elastic components installed at the revolute joint B. Elastic components placed at the prismatic joint D exhibit no compression variation during the coupled motion phase, resulting in better mechanical performance with zero energy loss. This configuration is also beneficial for the integrated design of the finger. For the SBI~SHI topological structures, the elastic components are relocated from joints B or D in the SB~SH structures to joint F, providing another variation for specific design requirements.
Based on the above analysis, this study utilizes the SB topological structure to design the transmission systems for the MCP and PIP joints of the anthropomorphic finger, enabling coupled-adaptive functionality. To simplify the finger’s design, the SA cross-coupled four-bar mechanism is applied to the PIP and DIP joints, achieving anthropomorphic coupled motion between them.
The coupled-adaptive nine-linkage mechanism, which integrates the SA and SB topological structures, is shown in Figure 3. Based on its linkage composition and mechanical motion transmission, the mechanism can be decomposed into three closed kinematic chains: the four-bar driving mechanism (A-B-D-C), the five-bar adaptive mechanism (A-C-D-E-F), and the four-bar coupling mechanism (F-G-I-H). First, the four-bar driving mechanism and the five-bar adaptive mechanism are connected in parallel, forming a coupled-adaptive seven-bar mechanism, where composite joint D integrates both prismatic and revolute motions. Then, the coupled-adaptive seven-bar mechanism is connected in series with the four-bar coupling mechanism, resulting in a coupled-adaptive nine-bar mechanism. This hybrid system combines serial and parallel linkages. Due to the presence of elastic joint D, the anthropomorphic finger based on this nine-linkage mechanism outputs two degrees of freedom only under specific external disturbances.
In Figure 3, hinge A, hinge F, and hinge H correspond to the MCP, PIP, and DIP joints of the anthropomorphic finger, respectively. Links AF, FH, and HJ represent the proximal, middle, and distal phalanges of the finger. Link AC is a fixed linkage attached to the base joint, AB is the driving linkage connected to the driving source, and BD is the follower link that transmits motion and force. The adaptive linkage group CE is composed of a crank CD and a sliding linkage DE, connected via the prismatic joint D. An elastic component is installed between CD and DE with a pre-compression force, maintaining the stability of the finger configuration in free space and preventing undesired motion before the proximal phalange (AF) contacts an object. In this state, the displacement of joint D remains zero (δ = 0), as shown in Figure 4a,b.
The compression spring also enables controlled decoupling motion during the adaptive phase. As illustrated in Figure 4c,d, once the proximal phalange (AF) contacts an object and stops moving, the PIP and DIP joints continue to move until the finger fully envelops the object. At this point, joint D generates a displacement offset δ, and the spring compression increases by δ. There is no adaptive behavior between the PIP and DIP joints; instead, their coupled motion is transmitted through the coupling rod GI. The joint angle transmission ratio between the DIP and PIP joints is designed as 2:3 [43], striking a balance between mimicking human grasping behavior and simplifying the complexity of the prosthetic hand.

3. Parameter Design of the Linkage Mechanisms

The previous section introduced the design of the coupled-adaptive nine-linkage mechanism with prismatic joints and elastic components, as shown in Figure 3. This mechanism is based on traditional coupling linkage structures and consists of three main parts: a four-bar driving mechanism, a five-bar adaptive mechanism, and a four-bar coupling mechanism. These parts serve three key functions: transmitting motion and force from the actuator to the finger phalanx, enabling coupled-adaptive motion of the MCP and PIP joints, and achieving coupled motion between the PIP and DIP joints.
Furthermore, this section employs the statistical mean square error method and uses the initial and final joint positions as design constraints to optimize the linkage parameters of the coupled-adaptive finger mechanism. The aim is to identify structural parameters for the transmission system that align with the requirements of integrated anthropomorphic prosthetic hand design.
As shown in Figure 3, the coupled-adaptive nine-linkage mechanism can be divided into three kinematic chain subsystems: the coupled four-bar chain F-H-I-G-F, the adaptive five-bar chain A-F-E-D-C-A, and the driving four-bar chain A-B-D-C-A. As illustrated in Figure 5, in free space, the MCP and PIP joints, as well as the PIP and DIP joints, exhibit anthropomorphic coupled motion patterns. During this phase, the displacement δ of joint D remains zero. Thus, in free space, the kinematic chains A-F-E-D-C-A and F-H-I-G-F can be equivalently simplified into two isomorphic cross-coupled four-bar mechanisms A-F-E-C-A and F-H-I-G-F. Since motion transmission in non-parallelogram four-bar mechanisms is inherently nonlinear, the objective of subsequent parameter optimization is to achieve an approximately linear motion relationship between joint angles.
As shown in Figure 5, links AF, FH, and HJ correspond to the proximal, middle, and distal phalanges of the underactuated prosthetic finger, respectively. The angles are defined as follows: θ represents the driving angle of link AB; α represents the rotation angle of link AF relative to the base coordinate axis (MCP joint angular displacement); β represents the rotation angle of link FH relative to link AF (PIP joint angular displacement); and γ represents the rotation angle of link HJ relative to link FH (DIP joint angular displacement).
The coupled-adaptive linkage mechanism serves as the core component for transmitting motion and force in anthropomorphic fingers. Meanwhile it is one of the most complex structures in the mechanical replication of human fingers. Considering the requirements for anthropomorphic design and integrated functionality, the parameters of certain linkages in the coupled-adaptive mechanism can first be determined based on anthropomorphic design principles. Subsequently, the remaining linkage parameters can be calculated using geometric methods and the mean square error optimization approach, ensuring the mechanism’s kinematic relationships are accurately maintained.

3.1. Design of Finger Segment Lengths and Joint Angle Ranges

3.1.1. Length of the Finger Segments

Underactuated prosthetic fingers must mimic the natural structure of human fingers in terms of appearance, dimensions, and range of motion. Based on our previous measurements and statistical analysis of human hand parameters [44], and considering practical design requirements such as reducing width and thickness to accommodate additional components like sensors and gloves, the dimensions of the three segments of the anthropomorphic finger are designed as follows: AF = 45 mm, FH = 26 mm, HJ = 25 mm.

3.1.2. Width and Thickness of Finger Segments

The thickness and width of the finger segments are as follows: The proximal phalanx thickness Tfpp ≤ 17 mm; The media phalanx thickness Tfmp ≤ 15.5 mm; The distal phalanx thickness Tfdp ≤ 15.5 mm; The finger joint width Bf ≤ 16 mm.

3.1.3. Range of Motion of the Finger Joints

To ensure the underactuated finger achieves an anthropomorphic range of motion (ROM) and functionality, the motion ranges for the three joints are designed as follows: αmax = 90°, βmax = 102°, γmax = 68°. Additionally, the transmission ratio between the DIP and PIP joints is set to 2:3, allowing the coupled motion relationship between the middle and distal phalanges of the human finger to be replicated [45].

3.2. Sequence of Parameter Optimization for the Linkage Mechanism

To minimize the number of design parameters requiring optimization, after determining basic parameters such as finger segment lengths and joint angle ranges, the following methods are applied: (a) In the A-F-E-C-A kinematic chain, determine the installation position of hinge E, specifically the length and angle ζ of link EF. (b) In the F-H-I-G-F kinematic chain, determine the installation position of hinge I, specifically the length and angle ψ of link HI. (c) Optimize the lengths of links AC, CE, FG, and GI to achieve a quasi-linear transfer ratio between the joint angles.
These steps ensure effective parameter determination while reducing the complexity of the optimization process. The solution sequence is as follows: First, solve the linkage parameters in the coupled four-bar kinematic chain F-H-I-G-F. Then, determine the parameters in the adaptive five-bar kinematic chain A-F-E-D-C-A. Finally, solve the linkage parameters in the driving four-bar kinematic chain A-B-D-C-A.

3.3. Optimization Design of Linkage Parameters Based on Geometric and Mean Square Error Methods

As shown in Figure 5, to achieve the anthropomorphic design of the underactuated finger, this study sets the boundary conditions such that the MCP, PIP, and DIP joints of the underactuated finger can reach their maximum rotational positions, αmax, βmax, and γmax, respectively, in a free space. Based on these conditions, a constraint relationship can be established between the linkages GI and FG as
G I = F 1 F G , F H , H I , ψ ,
A constraint relationship is established between the linkages CE and AC as
C E = F 2 A C , A F , E F , ξ ,
The boundary constraint condition expression (1) for GI and FG can be derived from Equations (3) and (4)
G I = I y I 1 y I 1 x I x G y + I 1 x 2 + I 1 y 2 I x 2 I y 2 2 I 1 x 2 I x I x 2 + G y I y 2 ,
G x = I y I 1 y I 1 x I x G y + I 1 x 2 + I 1 y 2 I x 2 I y 2 2 I 1 x 2 I x ,
where Ix and Iy represent the horizontal and vertical coordinates of point I in the coordinate system {x1Fy1}; I1x and I1y represent the horizontal and vertical coordinates of point I1 in the coordinate system {x1Fy1}; and Gx and Gy represent the horizontal and vertical coordinates of point G in the coordinate system {x1Fy1}.
Based on the geometric constraints shown in Figure 5, the relationships between Ix, Iy, I1x, I1y, and the joint angle ranges αmax, βmax, and γmax can be derived as
I x = F H + H I cos ψ ,
I y = H I sin ψ ,
I 1 x = F H cos β max + H I cos β max + γ max ψ ,
I 1 y = F H sin β max + H I sin β max + γ max ψ ,
Based on the finger thickness constraint, the constraint range for G(Gx, Gy) is set as GyTfmp ⁄2. Additionally, since F-H-I-G is a cross-coupled four-bar mechanism, Gy ≥ 0. Combining these conditions, the constraint range for G(Gx, Gy) is
0 G y T f mp 2 ,
The boundary constraint condition expression (2) for CE and AC can be derived from Equations (10) and (11) as
C E = E y E 1 y E 1 x E x C y + E 1 x 2 + E 1 y 2 E x 2 E y 2 2 E 1 x 2 E x E x 2 + C y E y 2 ,
C x = E y E 1 y E 1 x E x C y + E 1 x 2 + E 1 y 2 E x 2 E y 2 2 E 1 x 2 E x ,
where Ex and Ey represent the horizontal and vertical coordinates of point E in the coordinate system {x0Ay0}; E1x and E1y represent the horizontal and vertical coordinates of point E1 in the coordinate system {x0Ay0}; Cx and Cy represent the horizontal and vertical coordinates of point C in the coordinate system {x0Ay0}.
Based on the geometric constraints shown in Figure 5, the relationships between Ex, Ey, E1x, E1y, and the joint angle ranges αmax, βmax, and γmax can be derived as
E x = A F + E F cos ζ ,
E y = E F sin ζ ,
E 1 x = A F cos α max + E F cos α max + β max ζ ,
E 1 y = A F sin α max + E F sin α max + β max ζ ,
Based on the finger thickness constraint, the constraint range for C(Cx, Cy) is set as CyTfpp ⁄2. Additionally, since A-F-E-C is a cross-coupled four-bar mechanism, Cy ≥ 0. Combining these conditions, the constraint range for C(Cx, Cy) is
0 C y T f pp 2 ,
The advantage of constraining the relationships between CE and AC, as well as between GI and FG, using the maximum joint angle positions is that it ensures zero error between the maximum joint angle positions and the anthropomorphic target values. Additionally, it reduces the number of parameters that need to be optimized. Through the above constraints, the remaining parameters to be determined in the transmission linkage mechanism are simplified to the design positions Gy for G(Gx,Gy) and Cy for C(Cx,Cy).
Unlike the design requirement for maximum joint angle positions, where joint angle vectors are fixed, the design goal for the driving angle is to achieve linearized transmission as much as possible while meeting the adaptive size constraints. To further reduce the number of parameters requiring optimization, the initial installation position of the prismatic joint D (the value of CDi) in the linkage C-D-E is first determined in the A-B-D-C-A kinematic chain. Additionally, the lengths of the driving linkages AB and BD are specified. Consequently, the parameters to be optimized in the A-B-D-C-A kinematic chain are the values of θ0 and θmax. Based on the geometric relationships, the constraint conditions can then be designed as
{ f ad α , β max < A B + B D 22.5 ° < θ 0 < 22.5 ° 90 ° < θ max < 180 ° ,
where fad(α, β) is the Distance from hinge A to hinge D. In the process of calculating the connecting rod parameters, the relationship between the joint angles δ1, δ2, and δ3 is used as the main reference index
δ 1 δ 2 δ 3 = β ƛ 1 γ α ƛ 2 β θ ƛ 3 α ,
Based on the geometric relationships between the linkages illustrated in Figure 5, the precise analytical expression for the coupling relationship among the joint angles α, β, and γ can be derived as
β = arccos F H + H I cos γ ψ F H 2 + H I 2 + 2 F H H I cos γ ψ + π φ arccos F G 2 + F H 2 + H I 2 G I 2 + 2 F H H I cos γ ψ 2 F G F H 2 + H I 2 + 2 F H H I cos γ ψ ,
α = arccos A F + E F cos β ζ A F 2 + E F 2 + 2 A F E F cos β ζ + ξ + 0.5 π arccos A C 2 + A F 2 + E F 2 C D i + D E 2 + 2 A F E F cos β ζ 2 A C A F 2 + E F 2 + 2 A F E F cos β ζ ,
θ = arccos A B 2 + A C 2 + C D i 2 B D 2 2 A C C D i cos X 1 2 A B A C 2 + C D i 2 2 A C C D i cos X 1 arccos A C C D i cos X 1 A C 2 + C D i 2 2 A C C D i cos X 1 + ξ + π θ 0 ,
where
X 1 = arccos A C + A F sin ξ α A C 2 + A F 2 + 2 A C A F sin ξ α arccos C D i + D E 2 + A C 2 + A F 2 E F 2 + 2 A C A F sin ξ α 2 C D i + D E A C 2 + A F 2 + 2 A C A F sin ξ α ,
The parameters ƛ 1 , ƛ 2 , and ƛ 3 are the proportional coefficients for the designed maximum joint angles of the coupled finger, which can be expressed as:
ƛ 1 ƛ 2 ƛ 3 = β max / γ max α max / β max θ max / α max ,
where αmax = 90° is the maximum motion angle of the MCP joint, βmax = 102° is the maximum motion angle of the PIP joint, and γmax = 68° is the maximum motion angle of the DIP joint.
The optimization objectives for the linkage parameters are as follows: when the MCP joint angle α varies within the range of 0 to αmax, the PIP joint angle β varies within the range of 0 to βmax, and the DIP joint angle γ varies within the range of 0 to γmax, the statistical values δ1, δ2, and δ3 (including their means E(δ1), E(δ2), and E(δ3), and their variances D(δ1), D(δ2), and D(δ3)) should be minimized, as defined by Equations (24) and (25)
E δ m = k = 1 n δ mk n , m 1 , 2 , 3 ,
D δ m = k = 1 n δ mk E δ m 2 n , m 1 , 2 , 3 ,
where n represents the number of sampling points for the joint angles within their respective motion ranges.
Based on the precision requirements in mechanical processing, the search accuracy for the installation positions of hinge C is set to 0.001 within the constraint range, while the search accuracy for the initial driving angle θ0 is set to 0.001° within its constraint range. Through iterative calculations, the computed values for the design parameters of the transmission linkage can be determined as
{ E δ 1 = 0.5471 ° D δ 1 = 0.0013 ° G x = 2.678 G y = + 2.766 ,
and
{ E δ 2 = 0.3378 ° D δ 2 = 0.0007 ° C x = 1.775 C y = + 5.886 ,
The computed values for the design parameters of the driving linkage are
{ E δ 3 = 0.2189 ° D δ 3 = 0.0003 ° θ 0 = 15.345 ° θ max = 148.00 ° ,
The joint angle error δ curves are shown in Figure 6. The horizontal axis represents time, corresponding to the process of the finger moving from its initial position to the maximum designed position, while the vertical axis represents the linear error δ of the joint angles. From the figure, it can be observed that the maximum linear errors resulting from the design parameters are δ 1 m a x = 0.923 ° , δ 1 m a x = 0.635 ° , and δ 1 m a x = 0.531 ° . These results indicate that the design parameters meet the required precision criteria.
The coupling ratio coefficients ƛ 1 , ƛ 2 , and ƛ 3 for the joint angles are shown in Figure 7. The horizontal axis represents time, indicating the process of the finger moving from its initial position to the maximum designed position, while the vertical axis represents the values of the coupling ratio coefficients ƛ 1 , ƛ 2 , and ƛ 3 . In the figure, the dashed lines represent the target coupling ratio coefficients ƛ 1 , ƛ 2 , and ƛ 3 at the maximum joint position, which correspond to the optimization target values. The solid lines represent the real-time coupling ratio coefficients ƛ 1 r , ƛ 2 r and ƛ 3 r . By combining these results with other predefined and derived parameter values, the design parameters for the coupled-adaptive linkage mechanism are summarized in Table 2 and Table 3. All length units are in millimeters.

4. Conclusions

The finger is the most fundamental execution unit for achieving dexterous and compliant manipulation tasks in prosthetic hands. This study focuses on a single modular underactuated finger mechanism and analyzes and compares homologous types of coupled-adaptive underactuated finger mechanisms, using a traditional cross-coupled lead screw mechanism as the topological analysis unit. Furthermore, the paper summarizes the characteristics of this class of underactuated fingers and proposes a design method for a coupled-adaptive nine-linkage mechanism suitable for humanoid fingers. The proposed three-joint finger mechanism incorporates multiple sets of linkage structures and utilizes linear motion pairs and compression springs to transition between coupled motion and adaptive motion. This design enables the underactuated finger to execute anthropomorphic coupled movements in free space and adaptive grasping motions when interacting with objects.
Moreover, by using the joint motion angles and dimensions of humanoid fingers as constraints and aiming to linearize the joint coupling motion ratios, a statistical approach was adopted to design the linkage parameters of the coupled-adaptive mechanism. The resulting optimized design achieved a maximum linear error of less than 1° for all three joint angles. This research provides a design basis for the integrated design of prosthetic hands. The design method proposed in this paper not only presents a novel linkage mechanism but also outlines and compares its isomorphic types. Furthermore, the optimization results provide an accurate maximum motion value for the finger. Future work will further investigate the integrated development and grasp planning of a five-fingered hand with coupled-adaptive fingers.

Author Contributions

Conceptualization, M.C. and L.J.; formal analysis, M.C. and Z.L.; investigation, M.C.; methodology, M.C.; software, Z.L.; supervision, L.J.; validation, M.C. and Z.L.; writing—original draft, M.C. and Z.L.; writing—review and editing, M.C., L.J. and Z.L. All authors have read and agreed to the published version of the manuscript.

Funding

This work is supported by the National Natural Science Foundation of China (Grant No. 52305299), China Postdoctoral Science Foundation (LBH-Z23135, 2023M740919), Pre-research Task (NO. SKLRS202409B) of State Key Laboratory of Robotics and Systems (HIT).

Institutional Review Board Statement

Not applicable.

Data Availability Statement

There are no data to be shared.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Bullock, I.M.; Borras, J.; Dollar, A.M. Assessing Assumptions in Kinematic Hand Models: A Review. In Proceedings of the 2012 4th IEEE RAS & EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob), Rome, Italy, 24–27 June 2012; pp. 139–146. [Google Scholar]
  2. Zheng, J.Z.; De La Rosa, S.; Dollar, A.M. An Investigation of Grasp Type and Frequency in Daily Household and Machine Shop Tasks. In Proceedings of the 2011 IEEE International Conference on Robotics and Automation, Shanghai, China, 9–13 May 2011; pp. 4169–4175. [Google Scholar]
  3. Iqbal, J.; Tsagarakis, N.G.; Caldwell, D.G. A Human Hand Compatible Optimised Exoskeleton System. In Proceedings of the 2010 IEEE International Conference on Robotics and Biomimetics, Tianjin, China, 14–18 December 2010; pp. 685–690. [Google Scholar]
  4. Li, G.; Li, B.; Sun, J.; Zhang, W.; Sun, Z.; Chen, Q. Development of a Directly Self-Adaptive Robot Hand with Pulley-Belt Mechanism. Int. J. Precis. Eng. Manuf. 2013, 14, 1361–1368. [Google Scholar] [CrossRef]
  5. Iqbal, J.; Ahmad, O.; Malik, A. HEXOSYS II—Towards Realization of Light Mass Robotics for the Hand. In Proceedings of the 2011 IEEE 14th International Multitopic Conference, Karachi, Pakistan, 22–24 December 2011; pp. 115–119. [Google Scholar]
  6. Mankowski, T.; Tomczynski, J.; Walas, K.; Belter, D. PUT-Hand-Hybrid Industrial and Biomimetic Gripper for Elastic Object Manipulation. Electronics 2020, 9, 1147. [Google Scholar] [CrossRef]
  7. Yang, H.; Wei, G.; Ren, L.; Qian, Z.; Wang, K.; Xiu, H.; Liang, W. A Low-Cost Linkage-Spring-Tendon-Integrated Compliant Anthropomorphic Robotic Hand: MCR-Hand III. Mech. Mach. Theory 2021, 158, 104210. [Google Scholar] [CrossRef]
  8. Quigley, M.; Salisbury, C.; Ng, A.Y.; Salisbury, J.K. Mechatronic Design of an Integrated Robotic Hand. Int. J. Robot. Res. 2014, 33, 706–720. [Google Scholar] [CrossRef]
  9. Zeng, B.; Fan, S.; Jiang, L.; Liu, H. Design and Experiment of a Modular Multisensory Hand for Prosthetic Applications. IR 2017, 44, 104–113. [Google Scholar] [CrossRef]
  10. Pertuz, S.A.; Llanos, C.H.; Munoz, D.M. Development of a Robotic Hand Using Bioinspired Optimization for Mechanical and Control Design: UnB-Hand. IEEE Access 2021, 9, 61010–61023. [Google Scholar] [CrossRef]
  11. Lee, D.-H.; Park, J.-H.; Park, S.-W.; Baeg, M.-H.; Bae, J.-H. KITECH-Hand: A Highly Dexterous and Modularized Robotic Hand. IEEE/ASME Trans. Mechatron. 2017, 22, 876–887. [Google Scholar] [CrossRef]
  12. Ma, R.R.; Odhner, L.U.; Dollar, A.M. A Modular, Open-Source 3D Printed Underactuated Hand. In Proceedings of the 2013 IEEE International Conference on Robotics and Automation, Karlsruhe, Germany, 6–10 May 2013; pp. 2737–2743. [Google Scholar]
  13. Martin, J.; Grossard, M. Design of a Fully Modular and Backdrivable Dexterous Hand. Int. J. Robot. Res. 2014, 33, 783–798. [Google Scholar] [CrossRef]
  14. Cui, Y.; An, X.; Lin, Z.; Guo, Z.; Liu, X.-J.; Zhao, H. Design and Implementation of an Underactuated Gripper with Enhanced Shape Adaptability and Lateral Stiffness through Semi-Active Multi-Degree-of-Freedom Endoskeletons. Int. J. Robot. Res. 2024, 43, 873–896. [Google Scholar] [CrossRef]
  15. Boisclair, J.-M.; Laliberte, T.; Gosselin, C. On the Design of an Adaptable Underactuated Hand Using Rolling Contact Joints and an Articulated Palm. J. Mech. Robot.-Trans. ASME 2023, 15, 051001. [Google Scholar] [CrossRef]
  16. Courchesne, J.; Cardou, P.; Rachide Onadja, P.A. A Compact Underactuated Gripper with Two Fingers and a Retractable Suction Cup. Front. Robot. AI 2023, 10, 1066516. [Google Scholar] [CrossRef]
  17. Hua, H.; Liao, Z.; Zhao, J. Design, Analysis, and Experiment of an Underactuated Robotic Gripper Actuated by Linear Series Elastic Actuator. J. Mech. Robot.-Trans. ASME 2023, 15, 021002. [Google Scholar] [CrossRef]
  18. Iqbal, J.; Tsagarakis, N.G.; Fiorilla, A.E.; Caldwell, D.G. Design Requirements of a Hand Exoskeleton Robotic Device. In Proceedings of the 14th IASTED International Conference on Robotics and Applications (RA), Cambridge, MA, USA, 2–4 November 2009; pp. 44–51. [Google Scholar]
  19. Iqbal, J.; Tsagarakis, N.G.; Caldwell, D.G. Design of a Wearable Direct-Driven Optimized Hand Exoskeleton Device. In Proceedings of the Fourth International Conference on Advances in Computer-Human Interactions (ACHI 2011), Gosier, France, 23–28 February 2011; Miller, L., Roncagliolo, S., Eds.; Iaria Xps Press: Wilmington, NC, USA, 2011; pp. 142–146. [Google Scholar]
  20. Xu, K.; Liu, H.; Du, Y.; Zhu, X. Design of an Underactuated Anthropomorphic Hand with Mechanically Implemented Postural Synergies. Adv. Robot. 2014, 28, 1459–1474. [Google Scholar] [CrossRef]
  21. Pedemonte, N.; Laliberté, T.; Gosselin, C. Design, Control, and Experimental Validation of a Handshaking Reactive Robotic Interface. J. Mech. Robot. 2016, 8, 011020. [Google Scholar] [CrossRef]
  22. Beschi, M.; Villagrossi, E.; Tosatti, L.M.; Surdilovic, D. Sensorless Model-Based Object-Detection Applied on an Underactuated Adaptive Hand Enabling an Impedance Behavior. Robot. Comput.-Integr. Manuf. 2017, 46, 38–47. [Google Scholar] [CrossRef]
  23. Jiang, L.; Zeng, B.; Fan, S. A Design Approach to the Configuration of a Prosthetic Hand. Ind. Robot Int. J. 2015, 42, 359–370. [Google Scholar] [CrossRef]
  24. Xu, K.; Liu, H.; Liu, Z.; Du, Y.; Zhu, X. A Single-Actuator Prosthetic Hand Using a Continuum Differential Mechanism. In Proceedings of the 2015 IEEE International Conference on Robotics and Automation (ICRA), Seattle, WA, USA, 26–30 May 2015; pp. 6457–6462. [Google Scholar]
  25. Belter, J.T.; Segil, J.L.; Dollar, A.M.; Weir, R.F. Mechanical Design and Performance Specifications of Anthropomorphic Prosthetic Hands: A Review. J. Rehabil. Res. Dev. (JRRD) 2013, 50, 599. [Google Scholar] [CrossRef]
  26. Bicchi, A.; Gabiccini, M.; Santello, M. Modelling Natural and Artificial Hands with Synergies. Philos. Trans. R. Soc. B Biol. Sci. 2011, 366, 3153–3161. [Google Scholar] [CrossRef]
  27. Hirano, D.; Nagaoka, K.; Yoshida, K. Design of Underactuated Hand for Caging-Based Grasping of Free-Flying Object. In Proceedings of the 2013 IEEE/SICE International Symposium on System Integration, Kobe, Japan, 15–17 December 2013; pp. 436–442. [Google Scholar]
  28. Zheng, E.; Zhang, W. An Underactuated PASA Finger Capable of Perfectly Linear Motion With Compensatory Displacement. J. Mech. Robot. 2019, 11, 014505. [Google Scholar] [CrossRef]
  29. Luo, C.; Zhang, W. VGS Hand: A Novel Hybrid Grasping Modes Robot Hand with Variable Geometrical Structure. Appl. Sci. 2019, 9, 1566. [Google Scholar] [CrossRef]
  30. Cui, J.; Yan, S.; Hu, J.; Chu, Z. A Metric to Design Spring Stiffness of Underactuated Fingers for Stable Grasp. Robot. Auton. Syst. 2018, 102, 1–12. [Google Scholar] [CrossRef]
  31. Liu, H.; Yang, D.; Jiang, L.; Fan, S. Development of a Multi-DOF Prosthetic Hand with Intrinsic Actuation, Intuitive Control and Sensory Feedback. Ind. Robot Int. J. 2014, 41, 381–392. [Google Scholar] [CrossRef]
  32. Cheng, M.; Fan, S.; Yang, D.; Jiang, L. Design of an Underactuated Finger Based on a Novel Nine-Bar Mechanism. J. Mech. Robot. 2020, 12, 065001. [Google Scholar] [CrossRef]
  33. Cheng, M.; Jiang, L.; Fan, S.; Yang, B.; Dai, J.; Liu, H. Development of a Multisensory Underactuated Prosthetic Hand With Fully Integrated Electronics. IEEE/ASME Trans. Mechatron. 2023, 28, 1187–1198. [Google Scholar] [CrossRef]
  34. Liu, H.; Xu, K.; Siciliano, B.; Ficuciello, F. The MERO Hand: A Mechanically Robust Anthropomorphic Prosthetic Hand Using Novel Compliant Rolling Contact Joint. In Proceedings of the 2019 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM), Hong Kong, China, 8–12 July 2019; pp. 126–132. [Google Scholar]
  35. Song, W.; Zhang, W. A Novel Coupling-Parallel-Adaption Merged Underactuated Finger with Link-Wheel Mechanism. In Proceedings of the 2018 IEEE International Conference on Robotics and Biomimetics (ROBIO), Kuala Lumpur, Malaysia, 12–15 December 2018; IEEE: Kuala Lumpur, Malaysia, 2018; pp. 2316–2321. [Google Scholar]
  36. Birglen, L. Type Synthesis of Linkage-Driven Self-Adaptive Fingers. J. Mech. Robot. 2009, 1, 021010. [Google Scholar] [CrossRef]
  37. Dechev, N.; Cleghorn, W.L.; Naumann, S. Multi-Segmented Finger Design of an Experimental Prosthetic Hand. In Proceedings of the Sixth National Applied Mechanisms & Robotics Conference, Cincinnati, OH, USA, 12–15 December 1999; pp. 1–8. [Google Scholar]
  38. Carrozza, M.C.; Suppo, C.; Sebastiani, F.; Massa, B.; Vecchi, F.; Lazzarini, R.; Cutkosky, M.R.; Dario, P. The SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping. Auton. Robot. 2004, 16, 125–141. [Google Scholar] [CrossRef]
  39. Sheng, X.; Hua, L.; Zhang, D.; Zhu, X. Design and Testing of a Self-Adaptive Prosthetic Finger with a Compliant Driving Mechanism. Int. J. Human. Robot. 2014, 11, 1450026. [Google Scholar] [CrossRef]
  40. Larouche, L.; Birglen, L. Assisted Design of Linkage-driven Adaptive Soft Fingers. Ind. Robot Int. J. 2013, 40, 337–346. [Google Scholar] [CrossRef]
  41. Birglen, L.; Gosselin, C. Optimal Design of 2-Phalanx Underactuated Fingers. In Proceedings of the International Conference on Intelligent Manipulation and Grasp, Genova, Italy, 1–2 July 2004; pp. 110–116. [Google Scholar]
  42. Zhang, W.; Zhao, D.; Zhou, H.; Sun, Z.; Du, D.; Chen, Q. Two-DOF coupled and self-adaptive (cosa) finger: A novel under-actuated mechanism. Int. J. Human. Robot. 2013, 10, 1330001. [Google Scholar] [CrossRef]
  43. Lee, J.; Kunii, T. Model-Based Analysis of Hand Posture. IEEE Comput. Graph. Appl. 1995, 15, 77–86. [Google Scholar] [CrossRef]
  44. Jiang, L.; Liu, Y.; Yang, D.; Liu, H. A Synthetic Framework for Evaluating and Designing an Anthropomorphic Prosthetic Hand. J. Bionic Eng. 2018, 15, 69–82. [Google Scholar] [CrossRef]
  45. Peerdeman, B.; Valori, M.; Brouwer, D.; Hekman, E.; Misra, S.; Stramigioli, S. UT Hand I: A Lock-Based Underactuated Hand Prosthesis. Mech. Mach. Theory 2014, 78, 307–323. [Google Scholar] [CrossRef]
Figure 1. Structure of the coupled mechanism. The joints A, F, and H correspond to the MCP joint, PIP joint, and DIP joint, respectively. The dash line indicates the initial position.
Figure 1. Structure of the coupled mechanism. The joints A, F, and H correspond to the MCP joint, PIP joint, and DIP joint, respectively. The dash line indicates the initial position.
Biomimetics 10 00170 g001
Figure 2. Type synthesis of linkage mechanism. Ta represents the driving position.
Figure 2. Type synthesis of linkage mechanism. Ta represents the driving position.
Biomimetics 10 00170 g002
Figure 3. Composition of the nine-bar linkage mechanism. Part I is four-bar driving mechanism, Part II is five-bar adaptive mechanism, and Part III is four-bar coupling mechanism.
Figure 3. Composition of the nine-bar linkage mechanism. Part I is four-bar driving mechanism, Part II is five-bar adaptive mechanism, and Part III is four-bar coupling mechanism.
Biomimetics 10 00170 g003
Figure 4. Sequence of the coupled-adaptive motion.
Figure 4. Sequence of the coupled-adaptive motion.
Biomimetics 10 00170 g004
Figure 5. Geometric constraints in the optimal design of four-bar linkage. The maximum rotation angles of the MCP, PIP, and DIP joints are as follows: αmax = 90°, βmax = 102°, γmax = 68°.
Figure 5. Geometric constraints in the optimal design of four-bar linkage. The maximum rotation angles of the MCP, PIP, and DIP joints are as follows: αmax = 90°, βmax = 102°, γmax = 68°.
Biomimetics 10 00170 g005
Figure 6. Linear errors of the joint angles.
Figure 6. Linear errors of the joint angles.
Biomimetics 10 00170 g006
Figure 7. Joint angles coupling coefficient.
Figure 7. Joint angles coupling coefficient.
Biomimetics 10 00170 g007
Table 1. Comparison of different topological structures.
Table 1. Comparison of different topological structures.
Topological
Structure
Mechanism
Type
Driving Joint
Position
Compound Joint
Position
Spring Installation
Position
SBSeven-bar mechanismJoint AJoint D: Prismatic + RevolutePrismatic Joint D
SCSeven-bar mechanismJoint AJoint E: Revolute + RevolutePrismatic Joint D
SDSeven-bar mechanismJoint AJoint E: Revolute + RevoluteRevolute Joint B
SESeven-bar mechanismJoint CJoint D: Prismatic + RevolutePrismatic Joint D
SFSeven-bar mechanismJoint CJoint E: Revolute + RevolutePrismatic Joint D
SGSeven-bar mechanismJoint CJoint E: Revolute + RevoluteRevolute Joint B
SHFive-bar mechanismJoint CJoint E: RevoluteRevolute Joint B
SBISeven-bar mechanismJoint AJoint D: Prismatic + RevoluteRevolute Joint F
SCISeven-bar mechanismJoint AJoint E: Revolute + RevoluteRevolute Joint F
SDISeven-bar mechanismJoint AJoint E: Revolute + RevoluteRevolute Joint F
SEISeven-bar mechanismJoint CJoint D: Prismatic + RevoluteRevolute Joint F
SFISeven-bar mechanismJoint CJoint E: Revolute + RevoluteRevolute Joint F
SGISeven-bar mechanismJoint CJoint E: Revolute + RevoluteRevolute Joint F
SHIFive-bar mechanismJoint CJoint E: RevoluteRevolute Joint F
SBSeven-bar mechanismJoint AJoint D: Prismatic + RevolutePrismatic Joint D
Table 2. Parameters of the links.
Table 2. Parameters of the links.
LinkAFFHHJABACBDCDiDEEFFGGIHI
Length (mm)4526255.86.151211.532.495.54.8524.255.5
Table 3. Parameters of the positions.
Table 3. Parameters of the positions.
Positionξφζψθ0θmax
Angle0.093π0.255π0.75π0.86π0.085π0.822π
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Cheng, M.; Jiang, L.; Liu, Z. Design and Optimization of an Anthropomorphic Robot Finger. Biomimetics 2025, 10, 170. https://doi.org/10.3390/biomimetics10030170

AMA Style

Cheng M, Jiang L, Liu Z. Design and Optimization of an Anthropomorphic Robot Finger. Biomimetics. 2025; 10(3):170. https://doi.org/10.3390/biomimetics10030170

Chicago/Turabian Style

Cheng, Ming, Li Jiang, and Ziqi Liu. 2025. "Design and Optimization of an Anthropomorphic Robot Finger" Biomimetics 10, no. 3: 170. https://doi.org/10.3390/biomimetics10030170

APA Style

Cheng, M., Jiang, L., & Liu, Z. (2025). Design and Optimization of an Anthropomorphic Robot Finger. Biomimetics, 10(3), 170. https://doi.org/10.3390/biomimetics10030170

Article Metrics

Back to TopTop