Next Article in Journal
Multi-Dimensional Validation of the Integration of Syntactic and Semantic Distance Measures for Clustering Fibromyalgia Patients in the Rheumatic Monitor Big Data Study
Next Article in Special Issue
Predictive Refined Computational Modeling of ACL Tear Injury Patterns
Previous Article in Journal
Dyadic and Individual Variation in 24-Hour Heart Rates of Cancer Patients and Their Caregivers
Previous Article in Special Issue
Inter-Specimen Analysis of Diverse Finite Element Models of the Lumbar Spine
 
 
Article
Peer-Review Record

Experimentally Validated Finite Element Analysis of Thoracic Spine Compression Fractures in a Porcine Model

Bioengineering 2024, 11(1), 96; https://doi.org/10.3390/bioengineering11010096
by Sacha Guitteny 1, Cadence F. Lee 1 and Farid Amirouche 1,2,*
Reviewer 1:
Reviewer 2:
Bioengineering 2024, 11(1), 96; https://doi.org/10.3390/bioengineering11010096
Submission received: 7 December 2023 / Revised: 22 December 2023 / Accepted: 11 January 2024 / Published: 18 January 2024
(This article belongs to the Special Issue Computational Biomechanics, Volume II)

Round 1

Reviewer 1 Report

Comments and Suggestions for Authors

Interesting paper about a Finite Element Analysis of thoracic spine compression fractures in a porcine Model. Analysis. The authors used only four porcine spines for their analysis. They may explain , whether this low number of specimen is really statistically sufficient for  FEA. 

Author Response

Response: Firstly, we thank you for your time and insight in reviewing this manuscript. The concern about the number of spines used for analysis is understandable—however, our work is analogous to existing studies performed in the field, utilizing multiple vertebrae from just a single porcine spine (Brummund et al., 2017) (Bright et al., 2017). We additionally observed consistency across the experimental compression results, which allowed us to perform FEA on multiple vertebrae from one porcine spine.

Reviewer 2 Report

Comments and Suggestions for Authors

Thank you for submitting your paper titled "Experimentally Validated Finite Element Analysis of Thoracic Spine Compression Fractures in a Porcine Model". We are very interested in this field of research and admire your work. After careful review and discussion, we would like to provide you with some suggestions and opinions to help you further improve your paper and make it more consistent with academic standards and publication requirements.

(1) In Section 2.1, we suggest that you further elaborate on why the middle part of the thoracic spine is more prone to wedge compression fractures, and provide relevant research or experimental evidence to support your viewpoint, making your writing more credible and persuasive.

(2) When polishing individual vertebrae, please further explain how to polish, what the purpose of polishing is, and how this affects the experimental results, helping readers better understand your experimental design and the reliability of the results.

(3) On page 4, it mentions the use of MIMICS and 3-MATIC software for three-dimensional reconstruction and refinement of the vertebral body. It is suggested to introduce the principles and applications of these two software, and provide some relevant literature support to help readers understand your experimental process and results.

(4) On page 5, please provide more information about multi-point constraints (MPC), such as how it connects control points with nodes that constitute the skull surface of the vertebral body, and its role and advantages.

(5) For the use of MTS units and OPTOTRAK devices, you can further introduce in detail the working principle, parameter settings, experimental steps of the equipment, as well as the analysis and processing methods of the obtained data.

(6) It is suggested that you introduce in detail the technical route and method flow of experimenting with simulated porcine thoracolumbar wedge fractures and establishing a finite element model based on CT in the method section, and explain the advantages and limitations of these techniques and methods.

(7) It is recommended that you add quality assurance and control measures for data collection and measurement in your study, such as how to ensure the accuracy and stability of the equipment during the experiment, how to eliminate experimental interference and errors, etc.

 

(8) While it mentions that animal specimens such as pig samples are suitable for similar studies on human spinal finite element models, there is no discussion on the limitations and restrictions of this research method. It is suggested that you discuss this, comparing the differences and applicable scenarios between human cadavers and animal specimens.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 2 Report

Comments and Suggestions for Authors

 My recommendation is accepted as it is.

Back to TopTop