Abstract
This systematic review and meta-analysis studied the clinical outcomes with physics forceps compared to those with conventional forceps for closed dental extraction. A systematic literature search was performed to identify all the published randomized clinical trials that compared the relevant clinical outcomes with physics forceps to those with conventional forceps for closed dental extraction. A total of 11 studies were included. The adverse events were significantly lower with physics forceps (n = 48) compared to with conventional forceps (n = 120), with an odds ratio of 0.42 [0.25, 0.70], Z = 3.78 (p = 0.0002), and I2 = 21%. There were statistically significant differences in the incidence of GL (p = 0.04), and tooth or root fracture (p = 0.0009). Operating time was significantly lower in physics forceps than that of conventional forceps, mean difference (−20.13 (−30.11, −10.15)), Z = 3.78 (p = 0.0001), I2 = 79%. The available evidence is limited by a high risk of bias and low evidence certainty. Based on the current evidence, physics forceps might be better than the conventional extraction forceps in terms of the extraction duration, pain after extraction, trauma to both hard and soft tissue, and complications. Physics forceps are newer instruments that have not yet been introduced in the teaching of dental graduates. The introduction of physics forceps can be time saving, less invasive and reduce post-extraction complications.
1. Introduction
Dental extraction is one of the most common procedures performed by dentists. Indications for extraction are impaction, tooth or root fracture, caries, or periodontal disease [1]. Using ideal principles of extraction permits the effective, efficient, and safe removal of teeth, reducing complications. The lack of proper instrumentation and physics principles can result in a long duration of extraction and iatrogenic trauma to the patient, and fatigue and injury to the clinician [1,2,3]. Atraumatic extraction is always preferred, especially in the case of a planned immediate implant placement, predictable orthodontic tooth movement, or in patients with compromised bone quality and quantity [4]. Immediate implant placement requires fully intact osseous and soft tissue, which can be achieved by less-traumatic tooth extraction [5,6,7]. Traditional forceps and elevators often result in soft- and hard-tissue damage to the loss of the buccal bony plate and interdental bone crest [8,9].
A variety of new instruments and techniques have been introduced for atraumatic tooth extractions. A powered periotome and newer implant drills are useful for immediate or delayed implant placement [6,10,11,12]. The physics forceps (GoldenDent, Roseville, MI, USA) provides a mechanical advantage to extract teeth reducing the use of excessive force [8]. This advantage minimizes root or alveolar bone fractures, and helps to preserves the surrounding bone. It has a bumper in the buccal vestibule and a thin beak on the lingual aspect of the tooth, and thus utilizes a first-class lever action by applying constant pressure that slowly elevates the root from the socket [13]. This causes the release of hyaluronidase in the periodontal-ligament (PDL) space, which results in the gradual release of the PDL, and the tooth becomes mobile and can be easily removed [14]. Multiple studies published comparative results of physics forceps compared to those of the conventional forceps [15,16,17,18,19,20,21,22,23,24,25]. A recent narrative systematic review also reported adverse events and operative time, comparing the physics and conventional forceps but a meta-analysis was not performed [26].
The objectives of this meta-analysis was to update the evidence comparing these two instruments and perform quantitative analysis of clinically important outcomes to present an absolute measure of effect. Additionally, a summary of findings table was constructed on the basis of the GRADE approach to ascertain the certainty of evidence, and provide a clinical recommendation based on the evidence.
2. Materials and Methods
2.1. Literature Search
This systematic review was registered on PROSPERO (CRD42021268530). Electronic literature search was performed on databases PubMed/Medline, Web of Science, U.S. clinical-trial registries (ClinicalTrials.gov), Google Scholar, and proceedings from major scientific meetings published by May 2020 in English language. The ClinicalTrials.gov website was searched for unpublished trials. The detailed search strategy is presented in Appendix A.
2.2. Study Selection
PRISMA reporting guidelines were followed. In addition, the PICOS principle that was used to select studies is provided in Table 1. Uncontrolled trials, reviews, letters to editors, case series and case reports, retrospective and prospective cohort studies, updates, interviews, commentaries, and animal studies were excluded.
Table 1.
PICOS (patients, intervention, comparison, outcomes, and study design) criteria to select studies.
2.3. Quality Assessment
The qualities of the included studies were assessed using criteria from the Cochrane Collaboration’s Handbook (Cochrane Handbook for Systematic Reviews of Interventions Version 5.1.0, Higgins and Greene) using the ROB 2 tool [27,28].
2.4. Statistical Analysis
This meta-analysis was performed with the Cochrane RevMan software version 5.4. Dichotomous nominal data with odds ratios and continuous scale data as mean differences at a 95% confidence interval were evaluated. In this meta-analysis, Mantel–Haenszel fixed effect models were established for dichotomous data and inverse variance random-effect models for continuous data. The I2 statistical test was conducted to study statistical heterogeneity. The evidence was graded, and certainty was derived with the GRADEpro Guideline Development Tool. When significant heterogeneity was encountered, visual inspection of the forest plot and formal sensitivity analysis were performed to explain the heterogeneity. Publication bias and the small-study effect were analysed with a funnel plot and formal statistical tests if required.
3. Results
We identified 11 articles that met our inclusion criteria (number of extracted teeth = 1028, physics forceps = 514, conventional forceps = 514) [15,16,17,18,19,20,21,22,23,24,25]. A diagram for the study selection is presented in Figure 1. The study characteristics, and results of primary and secondary outcomes are presented in Table 2.
Figure 1.
Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) flow diagram of trial selection.
Table 2.
Study characteristics.
All trials were performed in India except for one, which was conducted in Iraq. The included studies were published between 2014 and May 2020, with the sample size ranging from 14 to 200. Five trials [16,17,19,20,25] used the split-mouth technique to compare between two groups, while six other studies [15,18,21,22,24] used the parallel group-randomization technique. The randomization method was computer-generated in four studies [18,21,22,23], coin tossing in four studies [17,19,20], and there were no details of randomization in three studies [15,16,24]. Three studies included extractions of canines and incisors, eight of premolars, and four of molars. Three studies included more men, two studies had more women, one study had equal gender distribution, and five studies did not mention gender distribution. Buccal cortical plate fracture (BCPF), amount of soft-tissue or gingival loss (GL), post-operative pain, time taken for extraction, and crown or tooth and root fractures were the most common outcomes measured in most of the studies, followed by soft-tissue healing after extraction. Other outcomes that were measured were bleeding, the ease of the technique, the volume of analgesics taken, bone loss, dry socket, and infections. All the trials had a high risk of bias. The risk of bias in individual studies is shown in Figure 2. The risk of bias across the included studies is shown in Figure 3.
Figure 2.
Risk of bias within individual trials.
Figure 3.
Risk of bias across included trials.
The results of the meta-analysis of adverse events are presented in Figure 4, organised into subgroups (BCPF, gingival laceration, and tooth or root fracture). Adverse events were statistically significantly lower with the physics forceps (n = 48) compared to with the conventional forceps (n = 120), with odds ratio 0.42 (0.25, 0.70), Z = 3.78 (p = 0.0002), and I2 = 21%. There was a significant difference in the incidence of GL (p = 0.04), and tooth or root fracture (p = 0.0009).
Figure 4.
Meta-analysis of adverse events organised into subgroups (buccal cortical plate fracture, gingival laceration, and tooth or root fracture).
The meta-analytical results of operative time are presented in Figure 5. Operating time was statistically significantly lower in physics forceps than that in conventional forceps; mean difference (−20.13 (−30.11, −10.15)), Z = 3.78 (p = 0.0001), and I2 = 79%.
Figure 5.
Forest plot for the meta-analysis of operative time.
The results of the meta-analysis of pain on the first post-operative day are presented in Figure 6. The overall pain after extraction was better with physics forceps than that with conventional forceps (standardized mean difference = −0.81 (−1.64, 0.03)), but there was no significant difference (Z = 3.78 (p = 0.06) and I2 = 96%). The funnel plot presented in Figure 7 does not show significant asymmetry; hence, the probability of publication bias is lower. Formal statistical tests were not conducted because of the small number of studies consistently reporting on the same outcome.
Figure 6.
Forest plot for the meta-analysis of pain on first post-operative day.
Figure 7.
Funnel-plot analysis for publication bias.
4. Discussion
There was a significant reduction in adverse events (77 fewer per 1000) with the physics forceps compared to with the conventional forceps, which can be understood as 8 fewer adverse events per 100 extractions. Individually, the reduction in GL and tooth/root fracture are statistically significant with the physics forceps, but the difference did not achieve statistical significance for BCPF. This is a significant reduction in adverse clinical events with which to recommend a change in practice from regularly using the conventional to the physics forceps. The reduction in BCPF (56 fewer/1000), GL (138 fewer/1000), and tooth or root fracture (76 fewer/1000) is very promising and supports using the physics forceps over the conventional forceps. The evidence has low certainty for all the outcomes. Even the mean difference in operative time and pain on VAS favours the physics forceps with low-to-moderate certainty. The evidence for the outcomes of BCPF, GL and tooth or root fracture was very low because of inconsistencies in the measurement and the probability of selective reporting, and studies have a high risk of bias, used in the GRADE approach for the evaluation of evidence certainty (Table 3).
Table 3.
GRADE summary of findings.
The physics forceps design reduces the incidence of root fractures and maintains the buccal cortical plate. This is also necessary for the success of an immediate dental implant. The forceps is an innovative extraction instrument that can perform difficult extractions without the need to reflect a flap with predictable results [15,18,23]. The use of physics forceps helps in the prevention of marginal-bone and soft-tissue loss, maintaining gingival and periodontal integrity with fewer complications. In this study, for adverse events, the samples had low heterogeneity (I2 = 21%). For the operating time, the samples showed moderate-to-high heterogeneity (I2 = 79%). Sensitivity analysis by removing the results from Hasan and Shenoi brought the heterogeneity down to 58%. Similarly, for the pain after extraction, the samples showed high heterogeneity (I2 = 96%). Sensitivity analysis by selectively removing the studies did not resolve the heterogeneity. This high heterogeneity may be because of the subjective evaluation of pain on VAS. Although VAS is traditionally treated as a continuous outcome, it is essentially not a numerical scale, and is based on subjective perception. Similarly, various other comparative studies of physics versus conventional forceps in orthodontic extractions also showed better results for physics forceps [17,19,20,25]. Physics forceps showed better results in the extraction of premolars and molars [18,21,24].
Extractions using physics forceps are less invasive than those with conventional forceps, and can be considered a reliable method, requiring significantly less comparative intraoperative time. The physics forceps requires a learning curve, but gives the clinician the unique opportunity to atraumatically undertake conventionally difficult extractions in order to maintain alveolar height, thus facilitating immediate prosthetic rehabilitation. Unlike the use of conventional forceps in training in dental schools, the physics forceps is a novel instrument, however, the learning of wrist movements and the direction of application of force is not difficult for the users of conventional forceps. The physics forceps is more efficient in reducing operating time, and preventing marginal-bone and soft-tissue loss in orthodontically indicated premolar extractions, with comparable clinical outcomes to those of the conventional forceps, associated with few complications.
5. Conclusions
Physics forceps are newer instruments that have not yet been introduced in the teaching of dental graduates. Physics forceps compare well to the conventional extraction forceps in terms of extraction duration, pain after extraction, and lesser trauma to both hard and soft tissue, with fewer complications. We recommend the introduction of physics forceps in regular clinical use and the training of dental graduates. Further trials are required, especially in other population groups, to evaluate the physics forceps as a better alternative and successor to the conventional dental-extraction forceps.
Author Contributions
A.K.S.: Conceptualization, Methodology, Writing—Original draft preparation. N.K.: Data curation, Writing—Original draft preparation. N.A.: Writing—Reviewing and Editing. D.R.: Writing—Reviewing and Editing. T.S.: Writing—Reviewing and Editing. M.R.H.: Writing—Reviewing and Editing. All authors have read and agreed to the published version of the manuscript.
Funding
This work was supported by a Grant-in-Aid for Early-Career Scientists from the Japanese Society for the Promotion of Science KAKENHI-PROJECT (grant number 20K18541).
Institutional Review Board Statement
Not applicable.
Informed Consent Statement
Not applicable.
Data Availability Statement
Medline (PubMed) and Scopus databases.
Conflicts of Interest
The authors declare that they have no competing interest.
Appendix A
Search: physics forceps AND extraction
(“physics” [MeSH Terms] OR “physics” [All Fields] OR “physic” [All Fields]) AND (“surgical instruments” [MeSH Terms] OR (“surgical” [All Fields] AND “instruments” [All Fields]) OR “surgical instruments” [All Fields] OR “forcep” [All Fields] OR “forceps” [All Fields]) AND (“extract” [All Fields] OR “extract s” [All Fields] OR “extractabilities” [All Fields] OR “extractability” [All Fields] OR “extractable” [All Fields] OR “extractables” [All Fields] OR “extractant” [All Fields] OR “extractants” [All Fields] OR “extracted” [All Fields] OR “extractibility” [All Fields] OR “extractible” [All Fields] OR “extracting” [All Fields] OR “extraction” [All Fields] OR “extractions” [All Fields] OR “extractive” [All Fields] OR “extractives” [All Fields] OR “extracts” [All Fields])
References
- McKenzie, W.S. Principles of Exodontia. Oral Maxillofac. Surg. Clin. N. Am. 2020, 32, 511–517. [Google Scholar] [CrossRef] [PubMed]
- Dym, H.; Weiss, A. Exodontia: Tips and techniques for better outcomes. Dent. Clin. N. Am. 2012, 56, 245–266. [Google Scholar] [CrossRef] [PubMed]
- Weiss, A.; Stern, A.; Dym, H. Technological advances in extraction techniques and outpatient oral surgery. Dent. Clin. N. Am. 2011, 55, 501–513. [Google Scholar] [CrossRef] [PubMed]
- De Santis, D.; Sinigaglia, S.; Pancera, P.; Faccioni, P.; Portelli, M.; Luciano, U.; Cosola, S.; Penarrocha, D.; Bertossi, D.; Nocini, R.; et al. An overview of socket preservation. J. Biol. Regul. Homeost. Agents 2019, 33, 55–59. [Google Scholar]
- Quayle, A.A. Atraumatic removal of teeth and root fragments in dental implantology. Int. J. Oral Maxillofac. Implant. 1990, 5, 293–296. [Google Scholar]
- Levitt, D. Atraumatic extraction and root retrieval using the periotome: A precursor to immediate placement of dental implants. Dent. Today 2001, 20, 53–57. [Google Scholar]
- Kubilius, M.; Kubilius, R.; Gleiznys, A. The Preservation of Alveolar Bone Ridge during Tooth Extraction. Stomatologija 2012, 14, 3–11. Available online: http://www.ncbi.nlm.nih.gov/pubmed/22617329 (accessed on 15 October 2021).
- Misch, C.E.; Perez, H.M. Atraumatic Extractions: A Biomechanical Rationale. Dent. Today 2008, 27, 98, 100–101. Available online: http://www.ncbi.nlm.nih.gov/pubmed/18717405 (accessed on 15 October 2021).
- Thomson, P.J. Minimising trauma in dental extractions: The use of the periotome. Br. Dent. J. 1992, 172, 179. [Google Scholar] [CrossRef]
- Sharma, S.D.; Vidya, B.; Alexander, M.; Deshmukh, S. Periotome as an Aid to Atraumatic Extraction: A Comparative Double Blind Randomized Controlled Trial. J. Maxillofac. Oral Surg. 2015, 14, 611–615. [Google Scholar] [CrossRef] [Green Version]
- Krug, R.; Connert, T.; Soliman, S.; Syfrig, B.; Dietrich, T.; Krastl, G. Surgical extrusion with an atraumatic extraction system: A clinical study. J. Prosthet. Dent. 2018, 120, 879–885. [Google Scholar] [CrossRef] [PubMed]
- Al-Harbi, S.H. Minimizing trauma during tooth removal: A systematic sectioning approach. Eur. J. Esthet. Dent. Off. J. Eur. Acad. Esthet. Dent. 2010, 5, 274–287. [Google Scholar]
- Saund, D.; Dietrich, T. Minimally-invasive tooth extraction: Doorknobs and strings revisited! Dent. Update 2013, 40, 325–326, 328–330. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Raghu, K.; Selvakumar, S.R.; Muthukumar, R.; Thangavelu, A.; Sathyanarayanan, R.; Mani, M.; Balasubramaniam, M. Beak and bumper—Physics forceps: Evaluation of new technique in extraction. Indian J. Dent. Res. Off. Publ. Indian Soc. Dent. Res. 2020, 31, 4–13. [Google Scholar] [CrossRef] [PubMed]
- El-Kenawy, M.H.; Ahmed, W.M.S. Comparison Between Physics and Conventional Forceps in Simple Dental Extraction. J. Maxillofac. Oral Surg. 2015, 14, 949–955. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Panchal, K.V.; Shah, N.S.; Panchal, B. Comparative evaluation of efficacy of physics forceps versus conventional forceps in therapeutic extractions of premolars: A prospective clinical study. Int. J. Res. Med. Sci. 2020, 8. [Google Scholar] [CrossRef]
- Kapila, S.; Kaur, T.; Bhullar, R.S.; Sandhu, A.; Dhawan, A.; Kaur, A. Use of Physics Forceps in Atraumatic Orthodontic Extractions of Bilateral Premolars: A Randomized Control Clinical Study. J. Maxillofac. Oral Surg. 2020, 19, 347–354. [Google Scholar] [CrossRef]
- Shenoi, R.; Vadera, S.K.; Moriwal, N. Comparative evaluation of efficacy of physics forceps and conventional extraction forceps in extraction of upper molars—A randomised controlled trial. Int. J. Curr. Adv. Res. 2017, 6, 5467–5471. [Google Scholar]
- Patel, H.S.; Managutti, A.M.; Menat, S.; Agarwal, A.; Shah, D.; Patel, J. Comparative evaluation of efficacy of physics forceps versus conventional forceps in orthodontic extractions: A prospective randomized split mouth study. J. Clin. Diagn. Res. 2016, 10, ZC41. [Google Scholar] [CrossRef]
- Hariharan, S.; Narayanan, V.; Soh, C.L. Split-mouth comparison of Physics forceps and extraction forceps in orthodontic extraction of upper premolars. Br. J. Oral Maxillofac. Surg. 2014, 52, e137–e140. [Google Scholar] [CrossRef]
- Mandal, D.; Gupta, S.K.; Mittal, A.; Garg, R. Collate on the Ability of Physics Forceps V/S Conventional Forceps in Multirooted Mandibular Tooth Extractions. IOSR J. Dent. Med Sci. 2015, 14, 63–66. [Google Scholar]
- Mandal, S.; Mandal, S.B.; Kamal, V.; Kumar, A.; Gorka, K.; Kumar, A. Physics Forceps: A New Sensation in Exodontia? Int. J. Oral Care Res. 2016, 4. [Google Scholar] [CrossRef]
- Hasan, A.M. The Efficiency Of Physics Forceps In Comparison To The Conventional Dental Extraction Forceps: A randomized Clinical Trial. J. Baghdad Coll. Dent. 2019, 31. [Google Scholar] [CrossRef]
- Basheer, S.A. Comparative Evaluation between Physics Forceps and Conventional Extraction Forceps in Extraction of Maxillary Molars. Int. J. Appl. Dent. Sci. 2017, 34, 152. [Google Scholar]
- SonuneAvinash, M.; Borle, R.M.; Jadhav, A.A. Comparative Evaluation between Physics Forceps and Conventional Extraction Forceps in Orthodontic Extraction of Maxillary Premolars: A Prospective, Interventional, Single Blind, Randomized Split Mouth Study. Int. J. Pharm. Sci. Invent. 2017, 6, 4–8. [Google Scholar]
- Abdelwahab, M.; Nørholt, S.E.; Taneja, P. The Efficacy of Physics Forceps for Exodontia: A Systematic Review. J. Oral Maxillofac. Surg. Off. J. Am. Assoc. Oral Maxillofac. Surg. 2021, 79, 989.e1–989.e13. [Google Scholar] [CrossRef]
- Sterne, J.A.C.; Savović, J.; Page, M.J.; Elbers, R.G.; Blencowe, N.S.; Boutron, I.; Cates, C.J.; Cheng, H.-Y.; Corbett, M.S.; Eldridge, S.M. RoB 2: A revised tool for assessing risk of bias in randomised trials. BMJ 2019, 366, l4898. [Google Scholar] [CrossRef] [Green Version]
- Cochrane Handbook for Systematic Reviews of Interventions; Higgins, J.P.T.; Thomas, J.; Chandler, J.; Cumpston, M.; Li, T.; Page, M.J.; Welch, V.A. (Eds.) Version 6.2; John Wiley & Sons: Chichester, UK, 2019; Available online: www.training.cochrane.org/handbook (accessed on 15 October 2021).
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).