by Xiaomei Guo 1, Shidong Yang 2, Xiaojun Li 2, Liang Shi 3, Ertian Hua 1 and Zuchao Zhu 1,2,*
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Processes 2021, 9(9), 1576; https://doi.org/10.3390/pr9091576
Submission received: 4 August 2021 / Revised: 26 August 2021 / Accepted: 30 August 2021 / Published: 2 September 2021

Round 1

Reviewer 1 Report

Dear Authors,

I suggest these modification to improve your articles. 

1- the title is very general. it should be more specific to reflect the research you had done.

2- the problem did not explain well and it needs to be modified. 

3- in section 2.2, figure3 is completely non-related to the test.

4- in computational, you have used laminar flow, why? if you read turbomachinery simulations research, you will find they are turbulent.

5- for any numerical research, mesh and time-step independence is a must. please add related data to your research.

6- the quality of the figures (9 to the end) is very poor. please use better and more clear pictures.

Thanks

Reviewer

Author Response

Dear reviewer: Thank you for your good suggestions. We responded point to point, which can be seen in the attached file. Thank you very much .

Author Response File: Author Response.pdf

Reviewer 2 Report

The authors have done a good research work and it is very interesting for publication in Processes. There are only a few small comments that need to be resolved.
Line 42 and others. The authors mention several references consistent with the document, however, this bibliography is not cited in the text. Add.
Table 1 and others are not in the journal format.
Leave a space between the number and its units. Ex: Line 114, 38 cm
Figures 2 and 3, increase in size.
It would be convenient to support the discussion of the results with some similar studies and reference them in the bibliography.
The references are not in the journal format and the DOI of the mentioned articles must be included.

Author Response

Dear reviewer: Thank you for your good suggestions. We responded the questions point by point, which can be seen in the attached files. Thank you very much.

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

Dear Authors,

I think the current version of your manuscript is good to go.

Regards,

Reviewer