Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker

by
Ramida Dindamrongkul
1,
Thitiworn Choosong
2 and
Wandee Khaimook
1,*
1
Department of Otolaryngology Head and Neck Surgery, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
2
Department of Family and Preventive Medicine, Faculty of Medicine, Prince of Songkla University, Songkhla 90110, Thailand
*
Author to whom correspondence should be addressed.
Healthcare 2025, 13(10), 1113; https://doi.org/10.3390/healthcare13101113
Submission received: 8 April 2025 / Revised: 2 May 2025 / Accepted: 8 May 2025 / Published: 10 May 2025
(This article belongs to the Section Health Assessments)

Abstract

:
Background: Occupational hearing loss (OHL) is a primary concern in industrial settings. In hospitals, the healthcare workers are also exposed to noise and chemical agents, the reported hearing loss in this occupation is underestimated. Hearing examination is routinely evaluated in the range of conventional frequencies, which may not detect hearing problems early. Therefore, this study aimed to reveal the hearing thresholds among medical personnel exposed to loud noise and/or chemical environments, estimating the prevalence of hearing loss using four different audiological methods. Methods: One hundred and thirty-one medical personnel were recruited from different units at the same hospital and grouped into noise, chemical, and mixed exposure categories. The hearing thresholds were assessed using four audiological methods, conventional audiometry (CA), extended high-frequency audiometry (EHFA), standard frequency distortion product otoacoustic emission (DPOAE), and ultra-high-frequency DPOAE. Statistical analyses were performed using R. Results: Ultra-high-frequency DPOAE and EHFA showed a higher prevalence of hearing loss than CA and DPOAE. Even CA usually demonstrated hearing threshold within normal limits, this study found a notch audiogram pattern indicating a decline in hearing loss over time at frequencies of 2, 3, and 4 kHz in each age group and a sign at a frequency of 6 kHz. Conclusions: Evidence of hearing loss can be identified with ultra-high-frequency DPOAE and EHFA, despite conventional audiometry indicating normal hearing thresholds.

1. Introduction

Noise pollution negatively affects industrial workers; however, it also affects healthcare workers [1,2,3]. The World Health Organization (WHO) advises that individuals should not be exposed to noise levels exceeding 85 dB(A) within 1 h and 70 dB(A) within 24 h to reduce the adverse health effects of noise exposure. As a reference, normal conversational speech is usually equivalent to 60 dB(A); whereas, exposure to 85 dB(A) is comparable to the noise level of heavy city traffic or a loud restaurant. For hospital environments, noise levels during the daytime and nighttime should be controlled at <35 dB(A) and 30 dB(A), respectively [4]. Previous studies showed that the average of equivalent sound pressure levels in hospital ranges from 38.7 to 68.8 dB(A) during the day and 37 to 88.6 dB(A) at night, which does not comply with WHO recommendations [3]. Notably, the noise level in hospitals, including operating rooms and intensive care units, usually exceeds the limit, especially in the orthopedic department [1,2,5,6,7]. Sources of noise pollution include therapeutic instruments, bedside dialysis machines, air ventilators, printers, crying infants, public noise, and staff activities.
Occupational hearing loss (OHL) was not only associated with noise pollution but was also affected by chemical agents [8,9,10]. Individuals can inhale or absorb hazardous chemicals during work. Following this exposure, chemical agents can be absorbed into the bloodstream and various locations involving the auditory pathways.
Furthermore, medical personnel may encounter medications that pose a hearing loss risk during work. Ototoxic drugs, such as aminoglycoside antibiotics, salicylates, and platinum-based chemotherapy drugs, can cause hearing loss [11,12]. Previous studies have indicated that the effects of chemical exposure progressively increase over time in hearing disorders [13,14]. Over half of the nurses and pharmacists working in chemotherapeutic units complained of dizziness, and 75% were identified with a notch audiogram configuration at 4 and 6 kHz [10]. Following the high prevalence of cancer, medical personnel have also increased their exposure rate to ototoxic drugs, which may increase the risk of occupational diseases. Furthermore, they are frequently exposed to various factors, such as loud noise and substances that are psychologically and physiologically harmful. The long-term effects of combining these co-exposures increase the severity of emerging risks [15].
OHL is typically diagnosed using conventional audiometry (CA), which examines hearing thresholds across a full range of individuals frequencies from 0.25 to 8 kHz. A characteristic of OHL, particularly from exposure to high-frequency noise sources, is that it initially and primarily affects hearing thresholds at higher frequencies and progressively extends to lower frequencies as the hearing loss worsens [16]. CA typically assesses frequencies up to 8 kHz; therefore, it may fail to detect the early stages of extended high-frequency hearing loss. To identify cochlear damage at an earlier stage, extended high-frequency audiometry (EHFA) may require observation to detect hearing damage early at a frequency above 8 kHz. Although, EHFA is not currently used in routine clinical practice, studies have reported that testing at a frequency of 16 kHz in EHFA is highly sensitive for the early detection of noise-induced hearing loss [17,18]. However, CA and EHFA are subjective hearing tests that require individuals to respond to stimuli. Distortion product otoacoustic emission (DPOAE) and ultra-high-frequency DPOAE are useful objective tools for identifying preclinical hearing loss before it becomes detectable with CA [16,19]. According to the typical pattern of hearing loss, damage generally first occurs at high frequencies. DPOAE can assess cochlear function at frequencies up to 16 kHz with ultra-high-frequency DPOAE, providing an opportunity to detect cochlear dysfunction earlier, even before significant hearing threshold shifts are observed on CA. The DPOAE method is sensitive to detecting both early permanent hearing loss and temporary threshold shifts (TTS) in cochlea function caused by cochlear dysfunction, auditory fatigue, and ototoxic effects [19,20]. TTS is a common effect of loud noise exposure and represents a temporary reduction in hearing threshold. Although hearing may initially recover, repeated exposures can lead to progressive cochlear damage, eventually resulting in permanent hearing loss [21].
Previous studies have used DPOAE to indicate hearing changes attributable to ototoxic drugs [20,22,23]. Consequently, the earliest signs of underlying cochlear damage in medical personnel exposed to loud noise and/or chemicals, although their hearing is within normal limits when measured using the CA method, should be evaluated using EHFA and DPOAE. Therefore, we aim to explore the prevalence of hearing loss, as assessed by the following four audiological methods: CA, EHFA, standard frequency DPOAE, and ultra-high-frequency DPOAE, among medical personnel exposed to loud and/or chemical environments.

2. Methods

2.1. Participants

Medical personnel aged 21–60 years were recruited from many departments, such as medical respiratory care, emergency, dental, pharmacy, chemotherapy, anatomical pathology units, and operating rooms at Songklanagarind Hospital between March and November 2023. All participants were symmetrical hearing thresholds. Audiograms with interaural differences greater than 10 dB HL were excluded, as a standard clinical indicator of possible medical etiology. This criterion ensured the study focused specifically on the occupational impact on hearing loss. The participants were asked to identify their units, and it was grouped into three categories, loud noise, chemical, and mixed exposure, which were based on their self-rated exposure and job roles.

2.2. Hearing Evaluations

This cross-sectional study evaluated the hearing thresholds using four audiological methods, CA, EHFA, standard frequency DPOAE, and ultra-high-frequency DPOAE. All measurements took place in a soundproofed room. For the CA method, pulsed tones were stimulated via air conduction ranging from 0.25 to 8 kHz; whereas, EHFA was measured at 9, 10, 11.2, 12.5, 14, and 16 kHz. Normal hearing was defined as a hearing threshold ≤25 dB HL at each frequency tested. DPOAE was evoked by two pure-tone frequencies (f1 and f2) that maintained an f2/f1 ratio at 1.2, a setting to maximize the distortion product response [24]. The frequencies of f2 ranged from 552 to 7012 Hz and 8838 to 17,671 Hz for standard frequency and ultra-high-frequency DPOAE, respectively. The intensities of f1 and f2 were 65 dB SPL and 55 dB SPL, respectively. A healthy ear was considered as one having a DPOAE amplitude over −10 dB SPL at each frequency [25].

2.3. Statistical Analysis

Statistical analyses were performed using R software software version 4.1.2 [26] with packages “epicalc” [27], “ggplot2” [28], and “Rmisc” [29]; the unit of analysis was one person. Participant information included demographic data, such as exposure group, age group, working unit, duration of working and working hours, and the prevalence of abnormal hearing were recorded and presented in percentages. Hearing thresholds and DPOAE amplitude were presented descriptively as means ± standard deviations. To compare the prevalence of abnormal hearing and hearing thresholds among the loud noise, chemical, and mixed exposure groups, analysis of variance (ANOVA) was used. Statistical significance was set at p-value < 0.05.

3. Results

Demographic data and work-related information were collected from 131 participants using a structured self-administered questionnaire. Participants were asked to self-report their information before conducting hearing evaluations. Those participants were classified as an exposure group by self-reporting. The distribution of loud noise exposure was similar to that of mixed exposure, accounting for 51 participants; whereas, chemical exposure accounted for only 31 participants. Notably, most service sector workers in this study were employed in the operating room compared with workers in all other units. However, the highest prevalence of bilateral hearing loss was observed in the chemotherapy unit, accounting for 25%, with a trend toward greater occurrence among those who had worked for 21–30 years (Table 1). OHL develops slowly after several years of chemical exposure. The longer the working years, the greater the hearing loss observed.
Regarding the CA method, the mean hearing threshold at each frequency was determined to be within normal limits except at 3 kHz in the right ear for those who had been working for over 31 years (Supplementary Figure S1). Conversely, the EHFA method confirmed the early detection of hearing loss in the first 10-year working group at a frequency of 14 kHz. However, the 20-, 30-, and 40-year groups were detected early at 12.5 kHz, 11.2 kHz, and 9 kHz frequencies, respectively (Supplementary Figure S2).
Age is another factor that influences OHL. Supplementary Figure S3 illustrates the accelerated hearing thresholds at 6 and 8 kHz frequencies in those aged > 40 years. Additionally, noise notches in the CA method demonstrated a similar pattern of declined progression in hearing loss over time at frequencies of 2 kHz, 3 kHz, and 4 kHz in each age group. The CA method showed the characteristics of hearing loss in occupational and older participants; however, their hearing thresholds at each frequency were mostly within normal limits. In contrast, early signs of hearing loss can be detected in those aged <40 years at a frequency of 14 kHz, and it was mostly determined at 11.2 and 10 kHz in those aged 41–50 and 51–60 years, respectively (Supplementary Figure S4).
The prevalence of hearing loss in the three exposure groups was assessed using four methods. The EHFA and ultra-high-frequency DPOAE methods identified a higher prevalence of hearing loss than CA and standard frequency DPOAE, performed at frequencies below 8 kHz (Table 2). The prevalence of hearing loss in each exposure group did not show statistically significant differences; however, each hearing examination method was individualized to detect abnormalities within the different exposure groups. The percentage of patients with abnormal hearing detected using CA, EHFA, and standard frequency DPOAE was high in the mixed, chemical, and loud exposure groups, respectively. In addition, ultra-high-frequency DPOAE methods determined abnormal hearing in each exposure group at a high prevalence rate exceeding 82%.
Using the CA method, the mean hearing threshold in each exposure group showed statistically significant differences at 0.25 kHz, 6 kHz, and 8 kHz (Table 3). This indicates that the loud exposure group had the lowest hearing threshold compared with the other groups at these frequencies. Furthermore, the pattern of noise notches in the conventional audiogram was observed at 2 kHz, 3 kHz, and 4 kHz in the loud and mixed exposure groups. However, the chemical exposure group had hearing thresholds in a flat pattern at the frequency ranging from 0.25 to 4 kHz (Supplementary Figure S5).
CA is a standard method in routine clinical practice. However, in this study, the EHFA is recognized as a useful method for the early detection of OHL due to loud noise and/or chemical exposure. Hearing thresholds at extended high frequencies changed earlier than those at conventional frequencies. The mean hearing thresholds at frequencies of 12.5 kHz, proven completely over 25 dB HL, determined abnormal hearing (Supplementary Figure S6). The hearing thresholds of those exposed to chemical agents showed more severe hearing loss than others, especially at a frequency of 9 kHz, significantly different between the loud- and mixed-exposure groups (Table 4).
Notably, under 50% of participants indicated abnormal hearing using standard frequency DPOAE, which is performed at a frequency ranging from 552 to 7012 Hz; whereas, ultra-high-frequency DPOAE recordings from 8838 to 17,671 Hz determined the major prevalence of hearing loss at approximately 88%. The mean DPOAE amplitude was found lower than −10 dB SPL at frequencies of 8970 and 11,304 Hz, which is an ultra-high-frequency DPOAE; whereas, the lower frequency showed a DPOAE amplitude of over −10 dB SPL, indicating a healthy ear (Supplementary Figure S7). Notably, the mixed-exposure group had better DPOAE amplitudes at frequencies ranging from 703 to 2827 Hz than the other exposure groups (Table 5). Additionally, the ultra-high-frequency DPOAE amplitude at each frequency was not significantly different between the exposure groups (Table 6).
This study considered that EHFA and ultra-high-frequency DPOAE were methods for the early detection of hearing loss, even when individuals had normal hearing according to the CA method. One hundred and fifteen participants with normal hearing were assessed for hearing thresholds at extended high-frequency and DPOAE amplitudes. At a frequency of 14 kHz, the hearing threshold dropped to over 25 dB HL in the three exposure groups; whereas, a frequency of 12.5 kHz showed early detection only in the chemical and loud noise exposure groups (Supplementary Figure S8). The DPOAE amplitudes slightly decreased at the standard frequency and rapidly declined at the ultra-high frequency (Supplementary Figure S9). Therefore, the significant audiological methods for the early diagnosis of OHL would be beneficial for monitoring the workplace risks and preserve hearing ability at conventional frequencies before the severity of the loss increases and affects speech communication.

4. Discussion

Notably, in this study, we observed that most participants had normal hearing thresholds when assessed using the CA method; however, EHFA and ultra-high-frequency DPOAE effectively detected a high prevalence of hearing loss in the early stages. CA cannot access hearing function at an extended high-frequency stimulus; however, it is widely used in routine hearing assessment, because it is readily available. Therefore, in this study, we propose the advantages of a useful audiogram configuration for CA. First, we observed a definite decline in hearing thresholds among participants aged over 40 years, particularly at frequencies of 6 and 8 kHz, compared with younger age groups. However, the hearing thresholds at 6 and 8 kHz remained better than those at other frequencies, which may have been elevated owing to occupational factors. It should be noted that age-related hearing loss can also begin after the age of 40 years, particularly at higher frequencies [30,31]. Therefore, this study is limited in that it cannot fully distinguish the contributions of occupational exposure from age-related hearing loss. However, individuals over 40 years old should be closely monitored hearing loss.
Additionally, a noise notch audiogram demonstrated a similar pattern of declined progression in hearing loss over time at frequencies of 2 kHz, 3 kHz, and 4 kHz in each age group. Previous studies have shown that a sign of noise-induced hearing loss is demonstrated by a notch audiogram at 3 kHz, 4 kHz, or 6 kHz [32,33,34]. However, this study revealed that the progression of hearing loss was exacerbated at various frequencies beyond the initial impact of noise exposure. This discovery established a biomarker for the early signs of hearing loss at a frequency of 6 kHz, which resulted in a potentially resulting from multifactorial process involving aging and noise exposure. Aging exacerbates hearing loss through the degeneration of auditory structures [35]. Although our study was cross-sectional and does not demonstrate longitudinal progression, the findings suggest that the combination of aging and occupational exposures could compound the greater severity of hearing loss, particularly among medical personnel aged over 40 years, even when their hearing thresholds remain within normal limits.
The EHFA and ultra-high-frequency DPOAE methods identified a higher prevalence of hearing loss. These measurements have become more widespread in detecting early changes in cochlear function, especially OHL [16,36,37,38]. Furthermore, based on the physiology of hearing, hair cells at the base of the cochlea are harmed more by loud noise and/or chemical agents, which first affect the hearing threshold at higher frequencies and gradually extend to lower frequencies [39].
However, according to the gradual decline in OHL, a previous study reported a two-fold prevalence of hearing loss in those exposed to noise for greater than 10 years compared with those who worked within the first 10 years [40,41,42]. The CA method may require a longer working year duration to detect hearing loss. Therefore, hearing thresholds at extended high frequencies should be evaluated for the early determination of hearing loss. This can be attributed to the research finding that the EHFA method confirmed the early detection of hearing loss in the first 10-year working group. The hearing threshold at a frequency of 14 kHz was over 25 dB HL; whereas, that of the groups with 20, 30, and 40 years of working experience were first detected at frequencies of 12.5, 11.2, and 9 kHz, respectively. Furthermore, EHFA is useful for distinguishing OHL from loud noise and/or chemical exposure. Previous studies have found elevated hearing thresholds at 14 and 16 kHz in individuals exposed to noise [38,43,44]. In our findings, the hearing threshold at a frequency of ≥12.5 kHz is an early indicator of hearing loss, particularly in medical personnel exposed to chemical agents, who appear to have higher hearing thresholds than other groups. While this study acknowledged that these current findings do not fully establish a causal relationship between chemical exposure and hearing loss, they highlighted potential attention that individuals with chemical exposure should be closely monitored in hearing. Further research is needed to explore whether cumulative chemical exposure may contribute to hearing loss.
One approach that has been used to detect hearing loss is DPOAE. Previous studies have shown that DPOAE is more sensitive than CA in detecting noise-induced hearing loss [16,24,44]. The absence of DP amplitude is directly linked to the abnormal functioning of the outer hair cells [37]. Furthermore, in this study, we found an initial reduction in the DP amplitude at a frequency of 2827 Hz, in which the DP amplitude was lower than 0 dB SPL. The magnitude of reduction was also maximally decreased lower than −10 dB SPL at frequencies of 8970 and 11304 Hz. However, the DP amplitude decreased over a higher frequency range, and over 80% of abnormal DPOAE readings were detected at ultra-high- frequencies. The prevalence of hearing abnormalities was high, as detected using the EHFA.
Previous studies have suggested that the DP amplitude of frequency over 8 kHz should be used to indicate cochlear damage, as it is more variable than lower frequency stimuli [16,45]. Furthermore, in this study, we discovered a decline in DP amplitude at ultra-high frequencies and a reduction in hearing thresholds at extended high frequencies in participants with normal hearing. These findings encourage the use of ultra-high-frequency DPOAE and EHFA measures as battery tests in audiological measurements for monitoring OHL, even when individuals do not have changes in hearing at conventional frequencies.
This study has some limitations. Notably, it was conducted on a group of medical personnel who were exposed to low noise levels in hospital. Therefore, our findings may not apply to other occupations involving exposure to loud noise and/or chemicals. However, the outcome of this study demonstrated an additional audiological measurement that should be practically used for the early detection and monitoring of OHL, especially a pre-placement assessment program of the worker instead of CA, which is clinically used in routine practice. These outcomes also raise awareness of hearing loss, even in individuals without confirmation or possibly awareness of hearing problems.
Furthermore, hearing loss risk is associated with age, duration of working years, and recreational events. In future studies, factors associated with hearing should be controlled. Sources of background noise should be differentiated to affect hearing, and the exposure level and duration should be indicated. However, patients with abnormal hearing can be monitored to determine the possibility of hearing loss.

5. Conclusions

The identification of hearing loss using ultra-high-frequency DPOAE and EHFA might have occurred without a reduction in the hearing threshold being observed using CA and standard frequency DPOAE. Therefore, to facilitate early identification, ultra-high-frequency DPOAE and EHFA may be useful as part of a prevention hearing screening to detect and monitor hearing change in risk occupational groups.
Even though the extended high-frequency audiogram pattern appeared generally similar across exposure groups, elevated hearing thresholds of each exposure group were observed at different specific frequencies (e.g., 11.2 kHz in the chemical exposure group and 12.5 kHz in the noise exposure and mixed exposure groups). While these findings were not sufficient to infer causality, these may suggest that clinical assessments should consider prioritizing the evaluation of hearing thresholds at 11.2 and 12.5 kHz, depending on the type of exposure group. This approach could facilitate occupational hearing screening guidelines. Early identification at these frequencies would allow for the implementation of protective measures to preserve normal hearing thresholds at conventional frequencies, preventing the loss from extending into speech frequencies, where it would have a more significant impact on communication.

Supplementary Materials

The following supporting information can be downloaded at https://www.mdpi.com/article/10.3390/healthcare13101113/s1. Figure S1: Conventional audiometry comparing between groups of working years, including under 10 years, 11–20 years, 21–30 years, and 31–40 years; Figure S2: Extended high-frequency audiometry comparing between groups of working years, including under 10 years, 11–20 years, 21–30 years, and 31–40 years; Figure S3: Conventional audiometry comparing between groups of age, including 21–30 years, 31–40 years, 41–50 years, and 51–60 years; Figure S4: Extended high-frequency audiometry comparing between groups of age, including 21–30 years, 31–40 years, 41–50 years, and 51–60 years; Figure S5: Conventional audiometry comparing between groups of exposure, such as chemical exposure, loud exposure, and mixed exposure; Figure S6: Extended high-frequency audiometry comparing between groups of exposure, such as chemical exposure, loud exposure, and mixed exposure; Figure S7: DP-gram comparing between groups of exposure, such as chemical exposure, loud exposure, and mixed exposure; Figure S8: Extended high-frequency audiometry in normal hearing participants comparing between groups of exposure, such as chemical exposure, loud exposure, and mixed exposure; Figure S9: DP-gram in normal hearing participants comparing between groups of exposure, such as chemical exposure, loud exposure, and mixed exposure.

Author Contributions

R.D., T.C. and W.K. contributed to the conceptualization, data curation, methodology, and resources. T.C. contributed to the funding acquisition and project administration. R.D. and W.K. performed formal analysis, investigation, validation, visualization, writing—original draft. All authors have read and agreed to the published version of the manuscript.

Funding

This research was supported by the National Science Research and Innovation Fund (NSRF) and Prince of Songkla University (Grant No. MED66012445-0).

Institutional Review Board Statement

The study was conducted following the Declaration of Helsinki and approved by the Human Research Ethics Committee of the Faculty of Medicine, Prince of Songkla University (approval code REC.65-444-9-2 and date of approval 25 December 2022).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

Data are available on request from authors.

Acknowledgments

The authors would like to acknowledge all the participants and staff for their valuable contributions to conducting the research.

Conflicts of Interest

The authors declare no potential conflicts of interest with respect to the research, authorship, and/or publication of the article.

Abbreviations

OHL: occupational hearing loss; CA: conventional audiometry; EHFA: extended high-frequency audiometry; DPOAE: distortion product otoacoustic emissions.

References

  1. Sampieri, G.; Namavarian, A.; Levin, M.; Philteos, J.; Lee, J.W.; Koskinen, A.; Lin, V.; Lee, J. Noise in Otolaryngology—Head and Neck Surgery operating rooms: A systematic review. J. Otolaryngol.—Head Neck Surg. 2021, 50, 8. [Google Scholar] [CrossRef]
  2. Arabacı, A.; Önler, E. The Effect of Noise Levels in the Operating Room on the Stress Levels and Workload of the Operating Room Team. J. PeriAnesthesia Nurs. 2021, 36, 54–58. [Google Scholar] [CrossRef]
  3. de Lima Andrade, E.; da Cunha e Silva, D.C.; de Lima, E.A.; de Oliveira, R.A.; Zannin, P.H.T.; Martins, A.C.G. Environmental noise in hospitals: A systematic review. Environ. Sci. Pollut. Res. Int. 2021, 28, 19629–19642. [Google Scholar] [CrossRef]
  4. Berglund, B.; Lindvall, T.; Schwela, D. Guidelines for Community Noise [Internet]. 1999. Available online: https://www.who.int/publications-detail-redirect/a68672 (accessed on 18 February 2024).
  5. Maidl-Putz, C.; McAndrew, N.S.; Leske, J.S. Noise in the ICU: Sound levels can be harmful. Nursing2020 Crit. Care 2014, 9, 29. [Google Scholar] [CrossRef]
  6. Katz, J.D. Noise in the Operating Room. Anesthesiology 2014, 121, 894–898. [Google Scholar] [CrossRef]
  7. Nott, M.R.; West, P.D.B. Orthopaedic theatre noise: A potential hazard to patients. Anaesthesia 2003, 58, 784–787. [Google Scholar] [CrossRef]
  8. Cannizzaro, E.; Cannizzaro, C.; Plescia, F.; Martines, F.; Soleo, L.; Pira, E.; Lo Coco, D. Exposure to ototoxic agents and hearing loss: A review of current knowledge. Hear. Balance Commun. 2014, 12, 166–175. [Google Scholar] [CrossRef]
  9. Wang, T.C. Hearing Loss: From Multidisciplinary Teamwork to Public Health [Internet]; IntechOpen: London, UK, 2021. [Google Scholar] [CrossRef]
  10. Fernandes, N.M.; Pelissari, I.G.; Cogo, L.A.; Santos Filha, V.A.V.D. Workplace Activity in Health Professionals Exposed to Chemotherapy Drugs: An Otoneurological Perspective. Int. Arch. Otorhinolaryngol. 2016, 20, 331–338. [Google Scholar] [CrossRef]
  11. Rivetti, S.; Romano, A.; Mastrangelo, S.; Attinà, G.; Maurizi, P.; Ruggiero, A. Aminoglycosides-Related Ototoxicity: Mechanisms, Risk Factors, and Prevention in Pediatric Patients. Pharmaceuticals 2023, 16, 1353. [Google Scholar] [CrossRef]
  12. Schacht, J.; Talaska, A.E.; Rybak, L.P. Cisplatin and Aminoglycoside Antibiotics: Hearing Loss and Its Prevention. Anat. Rec. 2012, 295, 1837–1850. [Google Scholar] [CrossRef]
  13. Gedik Toker, Ö.; Kuru, E. The effect of occupational exposure to noise and chemical agents on hearing abilities. Arch. Environ. Occup. Health 2024, 79, 1–10. [Google Scholar] [CrossRef]
  14. Campo, P.; Morata, T.C.; Hong, O. Chemical exposure and hearing loss. Disease-a-Month 2013, 59, 119–138. [Google Scholar] [CrossRef]
  15. European Agency for safety and Health at Work. Combined Exposure to Noise and Ototoxic Substances|Safety and Health at Work EU-OSHA [Internet]. 2009. Available online: https://osha.europa.eu/en/publications/combined-exposure-noise-and-ototoxic-substances (accessed on 26 February 2024).
  16. Laffoon, S.M.; Stewart, M.; Zheng, Y.; Meinke, D.K. Conventional audiometry, extended high-frequency audiometry, and DPOAEs in youth recreational firearm users. Int. J. Audiol. 2019, 58, S40–S48. [Google Scholar] [CrossRef]
  17. Antonioli, C.A.S.; Momensohn-Santos, T.M.; Benaglia, T.A.S. High-frequency Audiometry Hearing on Monitoring of Individuals Exposed to Occupational Noise: A Systematic Review. Int. Arch. Otorhinolaryngol. 2016, 20, 281–289. [Google Scholar]
  18. Škerková, M.; Kovalová, M.; Mrázková, E. High-frequency audiometry for early detection of hearing loss: A narrative review. Int. J. Environ. Res. Public Health 2021, 18, 4702. [Google Scholar] [CrossRef]
  19. Moepeng, M.; Soer, M.; Vinck, B. Distortion product otoacoustic emissions as a health surveillance technique for hearing screening in workers in the steel manufacturing industry. Occup. Health South. Afr. 2017, 23, 8–13. [Google Scholar]
  20. Poling, G.L.; Vlosich, B.; Dreisbach, L.E. Emerging Distortion Product Otoacoustic Emission Techniques to Identify Preclinical Warning Signs of Basal Cochlear Dysfunction Due to Ototoxicity. Appl. Sci. 2019, 9, 3132. [Google Scholar] [CrossRef]
  21. Kujawa, S.G.; Liberman, M.C. Adding insult to injury: Cochlear nerve degeneration after “temporary” noise-induced hearing loss. J. Neurosci. 2009, 29, 14077–14085. [Google Scholar] [CrossRef]
  22. Brooks, B.; Knight, K. Ototoxicity monitoring in children treated with platinum chemotherapy. Int. J. Audiol. 2018, 57, S62–S68. [Google Scholar] [CrossRef]
  23. Reavis, K.M.; McMillan, G.; Austin, D.; Gallun, F.; Fausti, S.A.; Gordon, J.S.; Helt, W.J.; Konrad-Martin, D. Distortion-Product Otoacoustic Emission Test Performance for Ototoxicity Monitoring. Ear Hear. 2011, 32, 61–74. [Google Scholar] [CrossRef]
  24. Meng, Z.L.; Chen, F.; Zhao, F.; Gu, H.L.; Zheng, Y. Early detection of noise-induced hearing loss. World J. Clin. Cases. 2022, 10, 1815–1825. [Google Scholar] [CrossRef] [PubMed]
  25. Ramos, J.A.; Kristensen, S.G.B.; Beck, D.L. An Overview of OAEs and Normative Data for DPOAEs. Hear. Rev. 2013, 20, 30–33. [Google Scholar]
  26. R Core Team. R: The R Project for Statistical Computing [Internet]; R Foundation for Statistical Computing: Vienna, Austria, 2024; Available online: https://www.r-project.org/ (accessed on 26 April 2025).
  27. Chongsuvivatwong, V. Epicalc: Epidemiological Calculator [Internet]. 2024. Available online: https://cran.rproject.org/web/packages/epicalc/index.html (accessed on 26 April 2025).
  28. Wickham, H. ggplot2: Elegant Graphics for Data Analysis [Internet]; Springer: New York, NY, USA, 2009; Available online: https://link.springer.com/10.1007/978-0-387-98141-3 (accessed on 26 April 2025).
  29. Hope, R.M. Rmisc: Ryan Miscellaneous [Internet]. 2022. Available online: https://cran.rproject.org/web/packages/Rmisc/index.html (accessed on 26 April 2025).
  30. Bowl, M.R.; Dawson, S.J. Age-Related Hearing Loss. Cold Spring Harb. Perspect. Med. 2019, 9, a033217. [Google Scholar] [CrossRef]
  31. Lin, F.R. Age-Related Hearing Loss. New Engl. J. Med. 2024, 390, 1505–1512. [Google Scholar] [CrossRef] [PubMed]
  32. Chang, T.Y.; Liu, C.S.; Huang, K.H.; Chen, R.Y.; Lai, J.S.; Bao, B.Y. High-frequency hearing loss, occupational noise exposure and hypertension: A cross-sectional study in male workers. Environ. Health 2011, 10, 35. [Google Scholar] [CrossRef]
  33. May, J.J. Occupational hearing loss. Am. J. Ind. Med. 2000, 37, 112–120. [Google Scholar] [CrossRef]
  34. McBride, D.I.; Williams, S. Audiometric notch as a sign of noise induced hearing loss. Occup. Environ. Med. 2001, 58, 46–51. [Google Scholar] [CrossRef]
  35. Keithley, E.M. Pathology and mechanisms of cochlear aging. J. Neurosci. Res. 2020, 98, 1674–1684. [Google Scholar] [CrossRef]
  36. Abu-Eta, R.; Gavriel, H.; Pitaro, J. Extended High Frequency Audiometry for Revealing Sudden Sensory Neural Hearing Loss in Acute Tinnitus Patients. Int. Arch. Otorhinolaryngol. 2021, 25, e413–e415. [Google Scholar] [CrossRef]
  37. Jedrzejczak, W.W.; Pilka, E.; Ganc, M.; Kochanek, K.; Skarzynski, H. Ultra-High Frequency Distortion Product Otoacoustic Emissions for Detection of Hearing Loss and Tinnitus. Int. J. Environ. Res. Public Health 2022, 19, 2123. [Google Scholar] [CrossRef]
  38. Somma, G.; Pietroiusti, A.; Magrini, A.; Coppeta, L.; Ancona, C.; Gardi, S.; Messina, M.; Bergamaschi, A. Extended high-frequency audiometry and noise induced hearing loss in cement workers. Am. J. Ind. Med. 2008, 51, 452–462. [Google Scholar] [CrossRef]
  39. Dobie, R.A.; Hemel, S.V. Basics of Sound, the Ear, and Hearing. In Hearing Loss: Determining Eligibility for Social Security Benefits [Internet]; National Academies Press (US): Washington, DC, USA, 2004. Available online: https://www.ncbi.nlm.nih.gov/books/NBK207834/ (accessed on 14 April 2024).
  40. Biswas, N.; Alam, S.; Roy, D.; Rahman, A.; Rudra, R.; Rahman, B.; Arefin, M.; Ahmad, M.S.; Murshed, S.M.M. Prevalence of Hearing Loss among Noise Exposed Industrial Workers. Bangabandhu Sheikh Mujib Med. Coll. J. 2023, 1, 90–95. [Google Scholar]
  41. Gopinath, B.; McMahon, C.; Tang, D.; Burlutsky, G.; Mitchell, P. Workplace noise exposure and the prevalence and 10-year incidence of age-related hearing loss. PLoS ONE 2021, 16, e0255356. [Google Scholar] [CrossRef] [PubMed]
  42. Lie, A.; Skogstad, M.; Johannessen, H.A.; Tynes, T.; Mehlum, I.S.; Nordby, K.C.; Engdahl, B.; Tambs, K. Occupational noise exposure and hearing: A systematic review. Int. Arch. Occup. Environ. Health 2016, 89, 351–372. [Google Scholar] [CrossRef] [PubMed]
  43. Mehrparvar, A.H.; Mirmohammadi, S.J.; Ghoreyshi, A.; Mollasadeghi, A.; Loukzadeh, Z. High-frequency audiometry: A means for early diagnosis of noise-induced hearing loss. Noise Health 2011, 13, 402–406. [Google Scholar] [CrossRef] [PubMed]
  44. Mehrparvar, A.H.; Mirmohammadi, S.J.; Davari, M.H.; Mostaghaci, M.; Mollasadeghi, A.; Bahaloo, M.; Hashemi, S.H. Conventional Audiometry, Extended High-Frequency Audiometry, and DPOAE for Early Diagnosis of NIHL. Iran. Red Crescent Med. J. 2014, 16, e9628. [Google Scholar] [CrossRef]
  45. Dreisbach, L.E.; Long, K.M.; Lees, S.E. Repeatability of high-frequency distortion-product otoacoustic emissions in normal-hearing adults. Ear Hear. 2006, 27, 466–479. [Google Scholar] [CrossRef]
Table 1. Baseline characteristics of participants and prevalence of abnormal hearing in conventional audiometry method.
Table 1. Baseline characteristics of participants and prevalence of abnormal hearing in conventional audiometry method.
Characteristic.TotalBilateral Abnormal Hearing
n%n%
Exposure groupLoud exposure5138.959.8
Chemical exposure2922.1310.3
Mixed exposure5138.9815.7
WorkplacePharmacy department129.218.3
Operating room4836.636.25
Medical respiratory care unit107.6220.0
Emergency unit1713.0211.8
Dental unit1410.7214.3
Chemotherapy unit1612.2425.0
Anatomical pathology unit1410.7214.3
Age group21–303426.038.8
31–405542.011.8
41–503022.9930.0
51–60129.2325.0
Working year group1–107355.768.2
11–203526.738.6
21–30713.0685.7
31–4064.6116.7
Working hourWithin 8 h8564.91214.1
9–12 h4030.5410
Over than 12 h64.600
Table 2. The prevalence of abnormal hearing in exposure groups comparing between four audiological methods.
Table 2. The prevalence of abnormal hearing in exposure groups comparing between four audiological methods.
Audiological MethodsSideTotal
(n = 131)
Loud
Exposure
(n = 51)
Chemical
Exposure
(n = 29)
Mixed
Exposure
(n = 51)
p-Value *
n%n%n%n%
CARight1612.259.8310.3815.70.624
Left1612.259.8310.3815.70.624
EHFARight10781.74384.32586.23976.50.459
Left10983.24384.32793.13976.50.155
Standard
frequency DPOAEs
Right5138.92651.0931.01631.40.078
Left5642.72243.1931.02549.00.294
Ultra-high-
frequency DPOAEs
Right11688.54282.42793.14792.20.204
Left11990.84894.12689.74588.20.570
CA: conventional audiometry; EHFA: extended high-frequency audiometry; DPOAEs: distortion product otoacoustic emissions; p-value * < 0.05.
Table 3. Mean hearing threshold at different frequencies of conventional audiometry in each exposure group.
Table 3. Mean hearing threshold at different frequencies of conventional audiometry in each exposure group.
Frequency (kHz)SideHearing Threshold (dBHL)
Mean (SD)
p-Value *
Total
(n = 131)
Loud
Exposure
(n = 51)
Chemical
Exposure
(n = 29)
Mixed
Exposure
(n = 51)
0.25Right14.5 (5.1)13.8 (4.9)16.7 (5.0)14 (5.1)0.031 *
Left16.8 (4.4)16.2 (4.3)18.4 (4.0)16.5 (4.5)0.066
0.5Right15.5 (4.4)15.6 (3.7)15.7 (4.8)15.4 (4.8)0.952
Left16.1 (4.1)15.5 (3.8)17.2 (4.5)16.0 (4.1)0.185
1Right16.3 (4.7)16.1 (5.3)16.4 (4.2)16.5 (4.4)0.911
Left16.8 (5.2)16.4 (5.1)17.8 (4.5)16.8 (5.6)0.518
2Right18.5 (5.3)18.8 (6.0)18.4 (4.6)18.3 (5.1)0.893
Left16.9 (6.1)16.9 (6.3)16.9 (4.9)16.9 (6.5)1
3Right19.1 (6.3)18.6 (6.3)17.2 (5.8)20.6 (6.5)0.059
Left18.3 (6.0)17.8 (6.5)17.8 (4.5)19.1 (6.1)0.477
4Right18.2 (6.5)17.3 (6.6)17.1 (5.8)19.8 (6.7)0.081
Left19.3 (6.4)18.4 (6.6)19.0 (5.2)20.4 (6.8)0.292
6Right13.3 (7.2)11.9 (6.1)14.3 (6.1)14.1 (8.5)0.194
Left15.1 (8.1)12.9 (7.1)16.2 (7.4)16.7 (9.0)0.047 *
8Right11.9 (8.8)10.1 (8.1)15.5 (10.4)11.8 (8.2)0.029 *
Left12.6 (9.1)10.3 (7.8)16.4 (11.3)12.8 (8.3)0.014 *
dBHL: decibels hearing level; p-value * < 0.05.
Table 4. Mean hearing threshold at different frequencies of extended high-frequency audiometry in exposure group.
Table 4. Mean hearing threshold at different frequencies of extended high-frequency audiometry in exposure group.
Frequency (kHz)SideHearing Threshold (dBHL)
Mean (SD)
p-Value *
Total
(n = 131)
Loud
Exposure
(n = 51)
Chemical
Exposure
(n = 29)
Mixed
Exposure
(n = 51)
9Right10.2 (11.4)8.0 (10.0)16.2 (15.6)8.9 (8.8)0.005 *
Left11.5 (12.3)9.1 (10.5)17.1 (14.9)10.6 (11.5)0.015 *
10Right15.3 (14.4)12.3 (12.9)20.7 (19.2)15.3 (12.1)0.042 *
Left16.0 (14.4)14.7 (13.6)20.5 (16.4)14.7 (13.6)0.157
11.2Right20.6 (18.3)18.5 (16.2)25.7 (22.3)19.8 (17.4)0.223
Left19.8 (17.2)17.1 (14.2)25.7 (22.4)19.2 (16.2)0.093
12.5Right29.5 (21.7)28.4 (19.0)35.5 (25.4)27.1 (21.9)0.226
Left29.1 (21.0)29.1 (20.4)34.7 (23.6)26.0 (19.8)0.208
14Right39.2 (23.0)38.1 (21.4)42.4 (24.1)38.4 (24.2)0.697
Left38.5 (23.2)37.7 (23.0)44.5 (24.2)35.9 (22.8)0.271
16Right44.6 (19.8)44.3 (17.5)48.6 (18.1)42.5 (22.6)0.420
Left44.8 (18.2)45.0 (16.0)50.8 (19.4)41.3 (19.0)0.078
dBHL: decibels hearing level; p-value * < 0.05.
Table 5. DP amplitude at different frequencies of DPOAEs in exposure group.
Table 5. DP amplitude at different frequencies of DPOAEs in exposure group.
Frequency (Hz)SideDP Amplitude (dBSPL)
Mean (SD)
p-Value *
Total (n = 131)Loud
Exposure
(n = 51)
Chemical
Exposure
(n = 29)
Mixed
Exposure
(n = 51)
356Right3.7 (7.3)4.3 (7.7)3.4 (7.9)3.4 (6.5)0.818
Left3.9 (6.6)2.7 (7.3)5.1 (6.5)4.5 (5.8)0.230
444Right−3.3 (7.9)−4.7 (8.7)−1.6 (7.3)−3 (7.4)0.225
Left4.6 (6.5)3.9 (7.3)5.1 (6.2)4.9 (5.8)0.620
557Right5.3 (6.7)5.4 (6.3)4.6 (7.8)5.6 (6.6)0.794
Left5.4 (7.0)3.9 (8.0)6.8 (5.6)6.2 (6.6)0.128
703Right8.0 (6.7)7.4 (6.5)7.0 (6.7)9.2 (6.7)0.262
Left7.8 (6.4)7.0 (7.2)7.8 (5.6)8.5 (6.1)0.481
894Right9.6 (6.2)9.3 (6.4)9.3 (6.5)10.0 (6.0)0.786
Left9.4 (6.4)8.8 (6.9)8.8 (6.1)10.3 (6.1)0.451
1118Right8.5 (6.0)7.4 (6.5)7.2 (5.8)10.2 (5.3)0.025 *
Left8.3 (6.1)8.6 (6.2)6.8 (7.4)8.9 (5.1)0.314
1416Right6.5 (6.7)5.5 (7.9)4.6 (7.0)8.5 (4.4)0.018 *
Left6.6 (6.5)7.0 (6.7)5.0 (6.4)7.0 (6.4)0.332
1777Right5.5 (5.7)5.2 (5.9)4.0 (6.9)6.5 (4.8)0.168
Left4.8 (6.4)4.6 (6.7)4.6 (7.0)5.0 (6.0)0.933
2246Right2.2 (5.8)1.3 (6.0)2.0 (6.7)3.2 (4.9)0.253
Left1.7 (6.8)0.7 (7.4)2.2 (7.3)2.4 (5.8)0.416
2827Right−2.5 (6.6)−3.8 (6.1)−2.6 (7.9)−1.1 (6.0)0.107
Left−3.5 (7.0)−4.8 (7.8)−1.4 (5.0)−3.2 (6.9)0.111
3555Right−3.3 (7.9)−4.7 (8.7)−1.6 (7.3)−3.0 (7.4)0.225
Left−4.6 (8.4)−4.9 (8.5)−2.7 (7.1)−5.3 (9.0)0.380
4482Right−5.2 (8.0)−5.9 (9.4)−4.6 (7.1)−4.7 (6.9)0.670
Left−5.9 (8.0)−5.4 (8.6)−5.2 (6.2)−6.6 (8.3)0.668
5645Right−3.4 (8.7)−1.7 (8.0)−5.7 (10.1)−3.8 (8.4)0.129
Left−4.6 (9.2)−4.1 (10.4)−4.4 (6.9)−5.3 (9.2)0.809
DPOAEs: distortion product otoacoustic emissions; dBSPL: decibels sound pressure level; p-value * < 0.05.
Table 6. DP amplitude at different frequencies of ultra-high-frequency DPOAEs in exposure group.
Table 6. DP amplitude at different frequencies of ultra-high-frequency DPOAEs in exposure group.
Frequency (Hz)SideDP Amplitude (dBSPL)
Mean (SD)
p-Value *
Total (n = 131)Loud
Exposure
(n = 51)
Chemical
Exposure
(n = 29)
Mixed
Exposure
(n = 51)
7119Right−4.2 (8.6)−3.9 (7.9)−5.6 (9.9)−3.6 (8.6)0.582
Left−5.9 (9.1)−7.3 (9.8)−4.1 (8.9)−5.5 (8.5)0.307
8970Right−12.4 (6.1)−11.9 (5.6)−12.5 (6.7)−12.8 (6.4)0.756
Left−13 (6.4)−11.5 (5.8)−13.4 (6.1)−14.2 (6.9)0.103
11,304Right−13.7 (9.7)−11.4 (5.6)−15.8 (6.6)−15 (13.5)0.079
Left−13.5 (5.4)−14.0 (5.3)−12.9 (4.9)−13.4 (5.9)0.651
DPOAEs: distortion product otoacoustic emissions; dBSPL: decibels sound pressure level; p-value * < 0.05.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Dindamrongkul, R.; Choosong, T.; Khaimook, W. Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker. Healthcare 2025, 13, 1113. https://doi.org/10.3390/healthcare13101113

AMA Style

Dindamrongkul R, Choosong T, Khaimook W. Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker. Healthcare. 2025; 13(10):1113. https://doi.org/10.3390/healthcare13101113

Chicago/Turabian Style

Dindamrongkul, Ramida, Thitiworn Choosong, and Wandee Khaimook. 2025. "Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker" Healthcare 13, no. 10: 1113. https://doi.org/10.3390/healthcare13101113

APA Style

Dindamrongkul, R., Choosong, T., & Khaimook, W. (2025). Audiological Methods for Early Detection of Hearing Loss in Healthcare Worker. Healthcare, 13(10), 1113. https://doi.org/10.3390/healthcare13101113

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop