Scientia Pharmaceutica is published by MDPI from Volume 84 Issue 3 (2016). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with Austrian Pharmaceutical Society (Österreichische Pharmazeutische Gesellschaft, ÖPhG).
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Construction and Evaluation of Scopolamine Ion- Selective Electrode

Analytical Chemistry Department, Faculty of Pharmacy - Zagazig University, Zagazig, Egypt
*
Author to whom correspondence should be addressed.
Sci. Pharm. 2000, 68(3), 247-261; https://doi.org/10.3797/scipharm.aut-00-23
Submission received: 24 February 2000 / Revised: 6 June 2000 / Accepted: 6 June 2000 / Published: 6 July 2000

Abstract

The construction of plasticised PVC matrix-type scopolamine ion- selective membrane electrode and its use in the potentiometric determination of scopolamine in pharmaceutical preparations are described. It is based on the use of tlie ion-associate species, fonned by scopolainine cation and 5-nitrobarbitoric counter ion. The basic electrode peifonnance characteristics are evaluated according to IUPAC I-ecoininendatioiis. It exhibited a linear response for 1x10-2–1x10-5 M of scopolamine solutions with a cationic Nernstian slope over the pH range of 4-7. Common organic and inorganic cations showed negligible interference. Direct potentiometric determination of 1x10-2–1x10-5 M aqueous tubocurarine chloride using this membrane electrode system showed an average recovery of 99.05 with a mean standard deviation of 0.12. This electrode system was successfully applied to the potentiometric determination of scopolamine in some pharmaceutical preparations.
Keywords: Scopolamine membrane electrode; potentiometry; pharmaceutical analysis Scopolamine membrane electrode; potentiometry; pharmaceutical analysis

Share and Cite

MDPI and ACS Style

Shalaby, A.; El-Maamly, M.; Abdellatef, H. Construction and Evaluation of Scopolamine Ion- Selective Electrode. Sci. Pharm. 2000, 68, 247-261. https://doi.org/10.3797/scipharm.aut-00-23

AMA Style

Shalaby A, El-Maamly M, Abdellatef H. Construction and Evaluation of Scopolamine Ion- Selective Electrode. Scientia Pharmaceutica. 2000; 68(3):247-261. https://doi.org/10.3797/scipharm.aut-00-23

Chicago/Turabian Style

Shalaby, A., M. El-Maamly, and H. Abdellatef. 2000. "Construction and Evaluation of Scopolamine Ion- Selective Electrode" Scientia Pharmaceutica 68, no. 3: 247-261. https://doi.org/10.3797/scipharm.aut-00-23

Article Metrics

Back to TopTop