Erratum: Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33

1
Department of Electrical Engineering and Computer Science, Control Systems Group, Technical University of Berlin, Einsteinufer 17, D-10587 Berlin, Germany
2
Department VII, Electrical Engineering, Mechatronics and Optometry, Beuth Hochschule Berlin University of Applied Science, Luxemburger Straße 10, D-13353 Berlin, Germany
*
Author to whom correspondence should be addressed.
Actuators 2018, 7(1), 9; https://doi.org/10.3390/act7010009
Submission received: 8 March 2018 / Revised: 8 March 2018 / Accepted: 8 March 2018 / Published: 13 March 2018
The authors would like to correct the content of Table 2 and the text above Table 2 in their article: Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models (https://www.mdpi.com/2076-0825/6/4/33).
The unit of the correction angle d 0 , given in Table 2 of [1] on page 8, and the text above, is not degree but radian. Therefore, the angle correction is:
  • d 0 = 0.10 rad = 5.7296 for the DMSP-10-250 and
  • d 0 = 0.073 rad = 4.1826 for the DMSP-20-300
such that the correction of Table 2 is given by:
c 0 c 1 c 2 c 3 d 0
DMSP-10-250 74.085 MPa 689.20 MPa / m 1.8370 GPa / m 2 848.79 MPa / m 3 5.73
DMSP-20-300 93.232 MPa 715.29 MPa / m 1.5483 GPa / m 2 502.95 MPa / m 3 4.18
The authors apologize this literal mistake, but emphasize that the content of the article is still correct. The manuscript will be updated and the original will remain online on the article webpage, with a reference to this Erratum.

Reference

  1. Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33. [Google Scholar] [CrossRef]

Share and Cite

MDPI and ACS Style

Martens, M.; Boblan, I. Erratum: Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33. Actuators 2018, 7, 9. https://doi.org/10.3390/act7010009

AMA Style

Martens M, Boblan I. Erratum: Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33. Actuators. 2018; 7(1):9. https://doi.org/10.3390/act7010009

Chicago/Turabian Style

Martens, Mirco, and Ivo Boblan. 2018. "Erratum: Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33" Actuators 7, no. 1: 9. https://doi.org/10.3390/act7010009

APA Style

Martens, M., & Boblan, I. (2018). Erratum: Martens, M.; Boblan, I. Modeling the Static Force of a Festo Pneumatic Muscle Actuator: A New Approach and a Comparison to Existing Models. Actuators 2017, 6, 33. Actuators, 7(1), 9. https://doi.org/10.3390/act7010009

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop