Next Article in Journal
Prognostic and Genomic Analysis of Proteasome 20S Subunit Alpha (PSMA) Family Members in Breast Cancer
Next Article in Special Issue
The Pulmonary Artery Catheter in the Perioperative Setting: Should It Still Be Used?
Previous Article in Journal
Age-Related Differences in Cardiac Autonomic Control at Resting State and in Response to Mental Stress
Previous Article in Special Issue
Diagnostic Modalities in Critical Care: Point-of-Care Approach
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

End-Tidal Carbon Dioxide Pressure Measurement after Prolonged Inspiratory Time Gives a Good Estimation of the Arterial Carbon Dioxide Pressure in Mechanically Ventilated Patients

1
Assistance Publique des Hôpitaux de Paris, 94270 Le Kremlin Bicêtre, France
2
Faculty of Medicine, University of Paris-Saclay, 94270 Le Kremlin Bicêtre, France
3
Intensive Care Unit, Gustave Roussy Institute, 94800 Villejuif, France
4
Anesthesia Department, Gustave Roussy Institute, 94800 Villejuif, France
*
Author to whom correspondence should be addressed.
Diagnostics 2021, 11(12), 2219; https://doi.org/10.3390/diagnostics11122219
Submission received: 4 November 2021 / Revised: 23 November 2021 / Accepted: 24 November 2021 / Published: 27 November 2021
(This article belongs to the Special Issue Diagnostic Modalities in Critical Care)

Abstract

:
Background: End-tidal carbon dioxide pressure (PetCO2) is unreliable for monitoring PaCO2 in several conditions because of the unpredictable value of the PaCO2–PetCO2 gradient. We hypothesised that increasing both the end-inspiratory pause and the expiratory time would reduce this gradient in patients ventilated for COVID-19 with Acute Respiratory Distress Syndrome and in patients anaesthetised for surgery. Methods: On the occasion of an arterial blood gas sample, an extension in inspiratory pause was carried out either by recruitment manoeuvre or by extending the end-inspiratory pause to 10 s. The end-expired PCO2 was measured (expiratory time: 4 s) after this manoeuvre (PACO2) in comparison with the PetCO2 measured by the monitor. We analysed 67 Δ(a-et)CO2, Δ(a-A)CO2 pairs for 7 patients in the COVID group and for 27 patients in the anaesthesia group. Results are expressed as mean ± standard deviation. Results: Prolongation of the inspiratory pause significantly reduced PaCO2–PetCO2 gradients from 11 ± 5.7 and 5.7 ± 3.4 mm Hg (p < 0.001) to PaCO2–PACO2 gradients of −1.2 ± 3.3 (p = 0.043) and −1.9 ± 3.3 mm Hg (p < 0.003) in the COVID and anaesthesia groups, respectively. In the COVID group, PACO2 showed the lowest dispersion (−7 to +6 mm Hg) and better correlation with PaCO2 (R2 = 0.92). The PACO2 had a sensitivity of 0.81 and a specificity of 0.93 for identifying hypercapnic patients (PaCO2 > 50 mm Hg). Conclusions: Measuring end-tidal PCO2 after prolonged inspiratory time reduced the PaCO2–PetCO2 gradient to the point of obtaining values close to PaCO2. This measure identified hypercapnic patients in both intensive care and during anaesthesia.

1. Introduction

Lung involvement during SARS-CoV-2 infection frequently dominates the clinical picture of severe forms with both interstitial pneumonia related to the release of pro-inflammatory cytokines and vascular obstruction of thromboembolic origin [1]. According to international recommendations for Acute Respiratory Distress Syndrome (ARDS) management, protective ventilation is the rule. This practice often induces hypercapnia and requires regular checks of arterial CO2 pressure (PaCO2) to adjust the level of ventilation.
In healthy anaesthetised patients, the monitoring of end-tidal CO2 pressure (PetCO2) is mandatory even if it underestimates the PaCO2, with a gradient around 4.5–13 mm Hg [2]. Lung diseases are associated with pulmonary heterogeneity, and the PaCO2–PetCO2 gradient rises in unpredictable proportions [3,4,5,6,7,8]. Therefore, the PetCO2 value cannot be taken as a good estimate of alveolar PCO2 and hence cannot be used as an estimate of PaCO2. In previous studies in patients with acute lung injury, longer inspiratory time without a change in respiratory rate enhanced CO2 exchange [8]. During controlled ventilation in adults, the “expiratory plateau” is usually flat, but several factors, such as age and pulmonary disease, are associated with an increase in the slope of the “expiratory plateau”. A prolonged expiration manoeuvre improves the prediction of PaCO2 from end-tidal PCO2 [9].
Our hypotheses were that end-tidal PCO2 measured immediately after an inspiratory time (PACO2) prolonged by an inspiratory pause or recruitment manoeuvre could improve the estimation of PaCO2 and identify severe hypercapnia during mechanical ventilation in COVID ARDS patients or in patients anaesthetised for major surgery.

2. Methods

This study complied with the National Medical Ethics Regulation and was approved by the institution’s Clinical Research Commission on May 2020. Patients or relatives received information that their anonymous data would be used for research purposes and did not object.

2.1. Study Design

This study was prospective and observational, involving routine care of a unicentric cohort, and conducted at Gustave Roussy, Villejuif, France, in both the ICU and operating theatre. Included were patients with a COVID-19 diagnosis hospitalised for ARDS (COVID group), according to the Berlin definition [10], and patients anaesthetised for major cancer surgery requiring invasive arterial monitoring (anaesthesia group). Patients under protective mechanical ventilation were deeply anaesthetised, with or without muscle relaxation. Increased inspiratory time was used in routine care in two situations: recruitment manoeuvre or prolongation of end-inspiratory pause to measure static compliance. In both groups, measurements were performed only if a bad tolerance of apnoea or recruitment was not predicted because of haemodynamic conditions, and if it would not hinder the surgeon.

2.2. Protocol

In both groups, a 10 s (arbitrarily fixed) period of apnoea was obtained using either the end-inspiratory pause function for static compliance evaluation or an automatic recruitment manoeuvre on the intensive care respirator (Evita) or Perseus anaesthesia respirator. With the Zeus anaesthesia respirator, the manoeuvre consisted of sustained manual inflation of the anaesthesia reservoir bag to a peak inspiratory pressure of 30 cm H2O for 10 s. The fraction of inspired oxygen concentration (FiO2) was not changed during the procedures. Expiration time was set to 4 s by adjusting the respiratory rate to 10 cycles per minute, and an I:E ratio around 1:2, to obtain an expiratory plateau on CO2 recording. PCO2 was measured at the end of the 4 s expiration following the inspiratory pause or recruitment manoeuvre (PACO2).
The same investigator carried out all measurements, using a side-stream CO2 sensor, to ensure their comparability.
An arterial blood gas measurement was collected prior to each measurement of PACO2, to calculate the PaCO2–PetCO2 and the PaCO2–PACO2 gradients and the PaO2/FiO2 ratio. All patients already needed arterial catheters: none were placed expressly for the study.
As the patients’ respiratory and haemodynamic status varied over time, several measurements could be conducted for the same patient.

2.3. Other Collected Data

FiO2, basal EtCO2, tidal volume (Vt), respiratory rate (RR), inspiratory plateau pressure (Pplate), settled positive end expiratory pressure (PEEP), central temperature, and when available, level of muscle relaxation (T4/T1), haemodynamic profile including the heart rate (bpm), mean arterial pressure (mm Hg), and norepinephrine dose (milligrams per hour), were recorded for each measurement.

2.4. Statistical Analysis

Data are presented as mean values ± standard deviations. PaCO2 values were temperature-corrected, according to the Siggaard-Andersen equation [11]. The normal distributions of PetCO2, PACO2, and PaCO2 data were assessed using the Q-Q plot method.
When PACO2 was available from both the inspiratory pause and recruitment, the first measurement was considered for gradient analyses. Indeed, a residual effect of the first recruitment may bias the second measurement.
A paired, two-tailed Student’s t-test was used to compare the different values of PCO2. Correlation coefficients were obtained using the Pearson method to assess the correlation between pairs of PaCO2, PetCO2, and PACO2. PaCO2–PetCO2, PaCO2–PACO2, and PACO2–PetCO2 gradient data were compared using a two-tailed unpaired t-test.
Bland–Altman plots were used to test for paired PetCO2, PACO2, and PaCO2 agreement and reported with the 95% and 99% confidence intervals, for the separate and combined groups.
The statistical performance of PACO2 to detect normocapnia and hypercapnia was calculated for different thresholds of PACO2. It was calculated for the separate and combined groups.
All statistical results were considered significant if the p-value was less than 0.05. All calculations were performed using Microsoft Excel data processing software (2019 version).

3. Results

3.1. Population

From 8 April to 28 May 2020, 67 PACO2 were obtained for 34 patients (35 measures in 7 patients in the COVID group; 32 measures in 27 patients in the anaesthesia group).
Table 1 shows demographic data and baseline characteristics of the study day. Data were similar, except for PaCO2, with more hypercapnia in the COVID group (21 vs. 10), as expected. The COVID group presented worse pulmonary characteristics, with a lower compliance (24 vs. 71 mL cm H2O–1 in the anaesthesia group), and a lower PaO2/FiO2 ratio (264 vs. 337 mm Hg).
In the COVID group, only 29 basal PetCO2 values were available, due to an initial protocol breach (6 missing data for 2 patients). No PaCO2 and no PACO2 values were missing. Five patients were ventilated using an Evita intensive care respirator (corresponding to twelve measurements), and two patients by use of a Perseus anaesthesia respirator, due to a shortage of Evita respirators in the COVID context. In the anaesthesia group, no PetCO2, PACO2, or PaCO2 values were missing.

3.2. Student’s t-Tests

PetCO2 underestimated PaCO2 in both groups, with a mean level of Δ(a-et)CO2 of +11 ± 5.7 mm Hg (95% CI 8.8–13) and +5.7 ± 3.4 mm Hg (4.4–6.9) in the COVID and anaesthesia group, respectively (p < 0.001 for both). Increased inspiratory pause or recruitment manoeuvres significantly reduced the gradient to −1.2 ± 3.3 mm Hg (−2.3 to −0.05) (p = 0.043) in the COVID group, and −1.9 ± 3.3 mm Hg (−3.1 to −0.07) (p < 0.003) in the anaesthetised patients, with no significant difference between the two groups. Table 2.
Both PetCO2 and PACO2 showed statistically significant linear correlation with PaCO2 for the two groups. In both the separate groups and combined groups, increased inspiratory pause or recruitment manoeuvres improved this correlation. COVID–PACO2 showed the best correlation (R2 = 0.92).

3.3. Bland–Altman Dispersion

The Bland–Altman diagram for Δ(a-et)CO2 confirmed the poor estimation of PaCO2 by PetCO2. Considering all patient data, all but two values were within a large 95% confidence interval (−2 to +19), and the gradient increased with PaCO2, with great imprecision beyond 50 mm Hg (Figure 1). Increased inspiratory pause or recruitment manoeuvre induced a decrease in Δ(a-A)CO2, with a lower dispersion from −8 to +8 mm Hg. All but one value (from the anaesthesia group) were in the 99% confidence interval around the mean of the differences. These findings were verified when considering the separate groups (Figure 2).
Five measurements in the COVID group had a gradient higher than +2 mm Hg associated with suspected respiratory movements identified on the respiratory flow curves. Keeping only the measurements on apnoeic patients, the average and 99% confidence interval of Δ(a-A)CO2 decreased slightly (mean −2.1 ± 2.5 mm Hg (−3.1 to −1.0)).
All patients with a PACO2 greater than 50 mm Hg were hypercapnic, with a PaCO2 higher than 45 mm Hg. For both COVID and anaesthetised patients, the PACO2 threshold of 48 mm Hg yielded the best performance in identifying hypercapnic patients, with Sensitivity (Se) = 0.68, Specificity (Sp) = 0.92, Positive Predictive Value (PPV) = 0.88, Negative Predictive Value (NPV) = 0.77, positive Likelihood Ratio (LR+) = 8.1, and negative Likelihood Ratio (LR−) = 0.35. The global performance improved in the COVID group, with Se = 0.81, Sp = 0.93, PPV = 0.94, NPV = 0.77, LR+ = 11, and LR− = 0.21.

4. Discussion

Measuring PCO2 at the end of expiration following a recruitment manoeuvre or an inspiratory pause significantly decreased the gradient Δ(a-et)CO2 in both COVID and anaesthetised patients. The correlation between PACO2 and PaCO2 was better than the correlation between PetCO2 and PaCO2, especially in the COVID group. The measurement of PACO2 after inspiratory pause is completely non-invasive and does not require the patient to disconnect. It nevertheless justifies hygiene precautions such as those commonly observed during the management of suspected, probable, and confirmed cases of COVID-19 [12].
In the presence of correct measurement conditions, the absence of leakage and a respiratory rate < 30 per minute, PetCO2 allows the estimation of PaCO2 in healthy subjects in spontaneous ventilation [13]. Under anaesthesia, especially in mechanical ventilation, the Δ(a-et)CO2 cannot be overlooked. This gradient varies from patient to patient and increases with age, smoking, ASA class, lung disease (especially in cases of pulmonary embolism), and bradycardia. Δ(a-et)CO2 is not stable during anaesthesia, ranging from 4.5 to 13 mm Hg [2,14].
In the ARDS, the Δ(a-et)CO2 tends to increase with lung heterogeneity, as shown by Yousuf and colleagues in 2017: a greater gradient in moderate vs. mild ARDS was reported but no significant difference was found in severe vs. moderate ARDS [15]. A possible explanation could be that severe ARDS was associated with pulmonary hypertension and lower cardiac output, increasing dead-space areas that attenuate the gradient.
Many different methods have been used to estimate the PaCO2. PetCO2 presents a weak correlation in healthy lungs [14,16,17,18,19,20], worsening in sick lungs, with no difference in the accuracy using a main- or side-stream sensor [21,22]. In diseased lungs, results vary greatly between studies, with moderate correlations and large dispersion around the reference PaCO2 value [8,15]. While the measurement of transcutaneous PCO2 yields better results, its use is essentially limited to the paediatric intensive care unit [23].
Inspiratory time influences the PetCO2 value [24]. Some manoeuvres, such as a simple prolonged exhalation, have been proposed to reduce P(a-et)CO2 [9].
Out of a series of 16 patients undergoing thoraco-abdominal oesophagectomy, Tavernier and colleagues [9] showed a decrease in the P(a-et)CO2 gradient after prolonged expiration or prolonged expiration preceded by lung hyperinflation, from 9.8 ± 3.0 to 6.0 ± 3.8 and 4.5 ± 3.8 mm Hg, respectively. The authors concluded, however, that due to extreme inter-individual variability, these manoeuvres did not improve PetCO2’s assessment of PaCO2. However, PetCO2 can identify the most severe hypercapnia and hypocapnia. A PetCO2 between 30 and 35 mm Hg most often corresponds to normocapnia (35 to 45 mm Hg).
Several pathophysiological mechanisms could be involved to explain the effectiveness of our manoeuvre, as follows.
First, maintaining high pressure in the airways for a period of time allows some collapsed alveoli to open, homogenizing the distribution of the ventilation/perfusion ratio. The alveoli recruitment mechanism was evidenced by the greater decrease in the carbon dioxide gradient in the COVID group, demonstrated by a mean difference Δ(a-A)CO2 − Δ(a-et)CO2 of −12.2 vs. −7.5 mm Hg in the anaesthesia group. Several studies have shown that prolongation of the inspiratory time decreases alveolar dead-space [9,25]. Diffusion of CO2 is time-dependent, and this prolongation increases the time available for alveolar gas exchange.
Second, during apnoea, increased inspiratory time allows homogenisation of PCO2 in the alveoli and between the alveoli and blood. During prolonged apnoea, alveolar PCO2 approaches pulmonary venous blood PCO2 due to the absence of alveolar gas movement. This effect has certainly contributed to the reduction of CO2 gradients.
Under ARDS conditions, tidal volume was set to 6 mL/kg with a high respiratory rate to maintain alveolar ventilation and reduced expiratory time. This increased the consequences of inequalities in regional respiratory time constants. Hence, the PetCO2 value depended on short- and long-time constant alveoli gas mix. PACO2 tends toward the central venous PCO2 due to reduced expired volume of poorly ventilated alveoli. Setting the respiratory rate to 10 cycles per minute prior to each PACO2 measurement improved the expiration of long-time constant alveoli. The recruitment of high CO2-concentrated alveoli cumulated with the prolongation of expiration, inducing an increased expiratory CO2 peak, with PACO2 over-estimating the PaCO2 [26,27].
Late emptying of well-perfused alveoli with higher CO2 tensions and better overall ventilation/perfusion matching helped to reduce the gradient between PaCO2 and PetCO2, which became negative in some cases. Negative (a-et) PCO2 gradients have been reported in infants and children, in pregnant patients, and during exercise [11,26]. This late mechanism may play an important role.
Fletcher and Jonson have studied the Vd/Vt ratio and P(a-et)CO2 gradient at two levels of Vt (450 and 750 mL) in anaesthetised patients [28]. Increasing Vt and decreasing the respiratory frequency did not change the airway dead-space but decreased the alveolar dead-space ratio. This improvement with increasing Vt was attributed to beneficial effects on gas distribution and diffusion time. At large Vt, the P(a-et)CO2 gradient decreased from 4.5 to 2.5 mm Hg, with a negative gradient in some patients. It is difficult to distinguish between what amounts to an increase in inspiratory time and expiratory time. Increased inspiratory time improves the distribution of the ventilation/perfusion ratio, and increased expiratory time decreases alveolar dead-space.
Third, PetCO2 and PACO2 are measured by computer analysis of the highest point reached by the capnogram curve at the end of the expiration. The overall performance (response time) of the capnograph including the sample line may be insufficient when high respiratory frequencies are used [24,29]. It is possible that some PetCO2 values may have been underestimated due to insufficient capnograph response time relative to the respiratory rate used. Therefore, the 4 s extended expiration time reduced the expiratory slope and thus reduced the bias in the computer analysis of PetCO2.
Our study also had some limitations. First, the lack of hypocapnic patients does not allow us to draw conclusions about the capacity of the measurement to detect a PaCO2 less than 35 mm Hg under such conditions. Second, some measurements were suspected to have been collected under not completely apnoeic conditions. However, the accuracy of the Δ(A-a)CO2 was relatively unaffected by the inclusion or not of these measures in the Bland–Altman diagram.
Initially, the data analysis protocol did not anticipate how to deal with the PACO2 values obtained using both the inspiratory pause and recruitment methods. We chose to only consider the first of the two measures, hypothesising that the residual effect of the first might bias the interpretation of the second.
According to the Berlin definition [10], there was no severe ARDS in our study, and patients were not haemodynamically unstable. We cannot draw conclusions about the effectiveness of our methods in patients with more severe lung diseases.
To conclude, measuring PCO2 after a prolonged inspiration and expiration improves the estimation of PaCO2 from PetCO2 and the identification of hypercapnic patients mechanically ventilated during anaesthesia and for COVID-related ARDS. Measuring end-tidal PCO2 after prolonged inspiratory time reduced the PaCO2–PetCO2 gradient to the point of obtaining values close to PaCO2. This non-invasive measure seems particularly interesting when using small Vt in the protected ventilation. However, further studies are needed to explore its usefulness in other conditions, such as in brain-injured patients, severe ARDS, and/or hypocapnic patients.

Author Contributions

A.S. (Arthur Salomé) had full access to all of the data in the study and takes responsibility for the acquisition and integrity of the data and the accuracy of the data analysis; A.S. (Arthur Salomé) and J.-L.B. contributed to the conception and design of the study; A.S. (Arthur Salomé) and J.-L.B. contributed to the analysis and interpretation of the data; A.S. (Arthur Salomé) wrote the first draft of the manuscript; A.S. (Arthur Salomé), J.-L.B., and A.S. (Annabelle Stoclin) critically revised the manuscript; C.M. and P.S. critically revised the manuscript; A.S. (Arthur Salomé) was responsible for the statistical analysis. All authors approved the final version of the manuscript.

Funding

This research received no external funding.

Institutional Review Board Statement

The study was conducted according to the guidelines of the Declaration of Helsinki, and approved by the Institutional Review Board of Gustave Roussy Hopsital. (20-05-20).

Informed Consent Statement

Patients consent was waived as no change in current practice was performed.

Data Availability Statement

Data available on demand ([email protected]).

Conflicts of Interest

The authors declare that they have no conflict of interest.

References

  1. Maiese, A.; Manetti, A.C.; La Russa, R.; Di Paolo, M.; Turillazzi, E.; Frati, P.; Fineschi, V. Autopsy findings in COVID-19-related deaths: A literature review. Forensic Sci. Med. Pathol. 2021, 17, 279–296. [Google Scholar] [CrossRef] [PubMed]
  2. Raemer, D.B.; Francis, D.; Philip, J.H.; Gabel, R.A. Variation in PCO2 between arterial blood and peak expired gas during anesthesia. Anesth. Analg. 1983, 62, 1065–1069. [Google Scholar] [CrossRef]
  3. Belpomme, V.; Ricard-Hibon, A.; Devoir, C.; Dileseigres, S.; Devaud, M.L.; Chollet, C.; Marty, J. Correlation of arterial PCO2 and PETCO2 in prehospital controlled ventilation. Am. J. Emerg. Med. 2005, 23, 852–859. [Google Scholar] [CrossRef]
  4. Strang, C.M.; Hachenberg, T.; Fredén, F.; Hedenstierna, G. Development of atelectasis and arterial to end-tidal PCO2-difference in a porcine model of pneumoperitoneum. Br. J. Anaesth. 2009, 103, 298–303. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  5. Law, G.T.S.; Wong, C.Y.; Kwan, C.W.; Wong, K.Y.; Wong, F.P.; Tse, H.N. Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting. Hong Kong Med. J. 2009, 15, 440–446. [Google Scholar]
  6. Defilippis, V.; D’Antini, D.; Cinnella, G.; Dambrosio, M.; Schiraldi, F.; Procacci, V. End-tidal arterial CO2 partial pressure gradient in patients with severe hypercapnia undergoing noninvasive ventilation. Open Access Emerg. Med. 2013, 5, 1–7. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  7. Hardman, J.G.; Aitkenhead, A.R. Estimating alveolar dead space from the arterial to end-tidal CO2 gradient: A modeling analysis. Anesth. Analg. 2003, 97, 1846–1851. [Google Scholar] [CrossRef] [PubMed]
  8. Long, B.; Koyfman, A.; Vivirito, M.A. Capnography in the Emergency Department: A Review of Uses, Waveforms, and Limitations. J. Emerg. Med. 2017, 53, 829–842. [Google Scholar] [CrossRef]
  9. Tavernier, B.; Rey, D.; Thevenin, D.; Triboulet, J.P.; Scherpereel, P. Can prolonged expiration manoeuvres improve the prediction of arterial PCO2 from end-tidal PCO2? Br. J. Anaesth. 1997, 78, 536–540. [Google Scholar] [CrossRef]
  10. ARDS Definition Task Force; Ranieri, V.M.; Rubenfeld, G.D.; Thompson, B.T.; Ferguson, N.; Caldwell, E.; Fan, E.; Camporota, L.; Slutsky, A.S. Acute respiratory distress syndrome: The Berlin Definition. JAMA 2012, 307, 2526–2533. [Google Scholar] [CrossRef]
  11. Losa-Reyna, J.; Torres-Peralta, R.; Henriquez, J.J.G.; Calbet, J.A.L. Arterial to end-tidal Pco2 difference during exercise in normoxia and severe acute hypoxia: Importance of blood temperature correction. Physiol. Rep. 2015, 3, e12512. [Google Scholar] [CrossRef]
  12. Fineschi, V.; Aprile, A.; Aquila, I.; Arcangeli, M.; Asmundo, A.; Bacci, M.; Cingolani, M.; Cipolloni, L.; D’Errico, S.; De Casamassimi, I.; et al. Management of the corpse with suspect, probable or confirmed COVID-19 respiratory infection—Italian interim recommendations for personnel potentially exposed to material from corpses, including body fluids, in morgue structures and during autopsy practice. Pathologica 2020, 112, 64–77. [Google Scholar] [CrossRef]
  13. Liu, S.Y.; Lee, T.S.; Bongard, F. Accuracy of capnography in nonintubated surgical patients. Chest 1992, 102, 1512–1515. [Google Scholar] [CrossRef] [PubMed]
  14. Casati, A.; Salvo, I.; Torri, G.; Calderini, E. Arterial to end-tidal carbon dioxide gradient and physiological dead space monitoring during general anaesthesia: Effects of patients’ position. Minerva Anestesiol. 1997, 63, 177–182. [Google Scholar]
  15. Yousuf, T.; Brinton, T.; Murtaza, G.; Wozniczka, D.; Ahmad, K.; Iskandar, J.; Mehta, R.; Keshmiri, H.; Hanif, T. Establishing a gradient between partial pressure of arterial carbon dioxide and end-tidal carbon dioxide in patients with acute respiratory distress syndrome. J. Investig. Med. 2017, 65, 338–341. [Google Scholar] [CrossRef]
  16. Hinkelbein, J.; Floss, F.; Denz, C.; Krieter, H. Accuracy and precision of three different methods to determine Pco2 (Paco2 vs. Petco2 vs. Ptcco2) during interhospital ground transport of critically ill and ventilated adults. J. Trauma Acute Care Surg. 2008, 65, 10–18. [Google Scholar] [CrossRef]
  17. Nassar, B.S.; Schmidt, G.A. Estimating Arterial Partial Pressure of Carbon Dioxide in Ventilated Patients: How Valid Are Surrogate Measures? Ann. Am. Thorac. Soc. 2017, 14, 1005–1014. [Google Scholar] [CrossRef]
  18. Fox, B.D.; Joyal, D.; Schlesinger, R.D.; Eisenberg, M.J.; Langleben, D. Evaluation of the MicrostatTM sublingual PCO2 monitor in ambulatory patients. J. Clin. Monit. Comput. 2016, 30, 77–80. [Google Scholar] [CrossRef] [PubMed]
  19. Robbins, P.A.; Conway, J.; Cunningham, D.A.; Khamnei, S.; Paterson, D.J. A comparison of indirect methods for continuous estimation of arterial PCO2 in men. J. Appl. Physiol. 1990, 68, 1727–1731. [Google Scholar] [CrossRef] [PubMed]
  20. Fierstra, J.; Machina, M.; Battisti-Charbonney, A.; Duffin, J.; Fisher, J.A.; Minkovich, L. End-inspiratory rebreathing reduces the end-tidal to arterial PCO2 gradient in mechanically ventilated pigs. Intensive Care Med. 2011, 37, 1543–1550. [Google Scholar] [CrossRef]
  21. Chan, K.L.; Chan, M.T.V.; Gin, T. Mainstream vs. sidestream capnometry for prediction of arterial carbon dioxide tension during supine craniotomy. Anaesthesia 2003, 58, 149–155. [Google Scholar] [CrossRef]
  22. Kasuya, Y.; Akça, O.; Sessler, D.I.; Ozaki, M.; Komatsu, R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology 2009, 111, 609–615. [Google Scholar] [CrossRef] [Green Version]
  23. Duyu, M.; Çağlar, Y.M.; Karakaya, Z.; Aslan, M.U.; Yılmaz, S.; Leblebici, A.N.; Bektaş, A.D.; Bahar, M.; Yersel, M.N. Comparison of arterial CO2 estimation by end-tidal and transcutaneous CO2 measurements in intubated children and variability with subject related factors. J. Clin. Monit. Comput. 2021, 35, 101–111. [Google Scholar] [CrossRef]
  24. From, R.P.; Scamman, F.L. Ventilatory frequency influences accuracy of end-tidal CO2 measurements. Analysis of seven capnometers. Anesth. Analg. 1988, 67, 884–886. [Google Scholar] [CrossRef] [PubMed]
  25. Sturesson, L.W.; Malmkvist, G.; Allvin, S.; Collryd, M.; Bodelsson, M.; Jonson, B. An appropriate inspiratory flow pattern can enhance CO2 exchange, facilitating protective ventilation of healthy lungs. Br. J. Anaesth. 2016, 117, 243–249. [Google Scholar] [CrossRef] [Green Version]
  26. Bhavani-Shankar, K. Negative arterial to end-tidal CO2 gradients in children. Can. J. Anaesth. 1994, 41, 1125–1126. [Google Scholar] [CrossRef] [Green Version]
  27. Campbell, F.A.; McLeod, M.E.; Bissonnette, B.; Swartz, J.S. End-tidal carbon dioxide measurement in infants and children during and after general anaesthesia. Can. J. Anaesth. 1994, 41, 107–110. [Google Scholar] [CrossRef] [Green Version]
  28. Fletcher, R.; Jonson, B. Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration. Br. J. Anaesth. 1984, 56, 109–119. [Google Scholar] [CrossRef] [PubMed]
  29. Jaffe, M.B. Respiratory Gas Analysis-Technical Aspects. Anesth. Analg. 2018, 126, 839–845. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Bland–Altman diagram for the P(a-et)CO2 gradient, combined group. Red triangles: COVID patients; blue circles: anaesthesia patients.
Figure 1. Bland–Altman diagram for the P(a-et)CO2 gradient, combined group. Red triangles: COVID patients; blue circles: anaesthesia patients.
Diagnostics 11 02219 g001
Figure 2. Bland–Altman diagram for P(a-A)CO2 gradient. Solid red triangles, complete apnoea COVID patients; empty red triangles, incomplete apnoea COVID patient; blue circles, anaesthesia patients.
Figure 2. Bland–Altman diagram for P(a-A)CO2 gradient. Solid red triangles, complete apnoea COVID patients; empty red triangles, incomplete apnoea COVID patient; blue circles, anaesthesia patients.
Diagnostics 11 02219 g002aDiagnostics 11 02219 g002b
Table 1. Patient characteristics.
Table 1. Patient characteristics.
COVIDAnaesthesia
Measure (n)3532
% male (M/F ratio)0.29 (2/5)0.41 (11/16)
Mean Age (years) (range)65 (59–73)59 (23–78)
Ventilator (n)
          Evita20 (5)0
          Perseus12 (2)30 (24)
          Zeus05 (3)
Type of manoeuvre (n)
          Increased inspiratory pause3527
          Recruitment05
Heart rate (bpm) (SD)82 (13)78 (13)
MAP (mm Hg) (SD)81 (13)78 (14)
Norepinephrine (mg h−1)0.21 (0.46)0.24 (0.88)
Temperature (°C) (SD)37 (0.69)36 (0.71)
PaCO2 (mm Hg) (SD)49.3 (11)42.2 (5.0) *
PaCO2 (n)
          ≤35 mm Hg13
          35 to ≤45 mm Hg1319
          ≥45 mm Hg2110
Compliance (mL cm H2O−1)24 (9.8)72 (86) *
PaO2/FiO2 (mm Hg) (SD)224 (53)367 (110) *
MAP, mean arterial pressure; PaCO2, arterial carbon dioxide pressure; compliance = Vt/(Pplate-PEP): Vt, tidal volume; Pplate, plate pressure; PEP, positive end pressure. *, p < 0.05 versus COVID group.
Table 2. Mean PCO2 (mm Hg), and Student’s t-test for comparison of paired values in the COVID group, the anaesthesia group, and the combined groups.
Table 2. Mean PCO2 (mm Hg), and Student’s t-test for comparison of paired values in the COVID group, the anaesthesia group, and the combined groups.
GradientCOVIDAnaesthesiaCombined
MeanSDp-ValueMeanSDp-ValueMeanSDp-Value
PaCO24911 425.0 465.1
PetCO2399 374.0 387.3
PACO25111 444.7 464.6
D(a-et)CO2+115.7<0.001+5.73.4<0.001+8.25.4<0.001
D(a-A)CO2−1.23.30.043−1.93.3<0.003−1.53.3<0.001
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Salomé, A.; Stoclin, A.; Motamed, C.; Sitbon, P.; Bourgain, J.-L. End-Tidal Carbon Dioxide Pressure Measurement after Prolonged Inspiratory Time Gives a Good Estimation of the Arterial Carbon Dioxide Pressure in Mechanically Ventilated Patients. Diagnostics 2021, 11, 2219. https://doi.org/10.3390/diagnostics11122219

AMA Style

Salomé A, Stoclin A, Motamed C, Sitbon P, Bourgain J-L. End-Tidal Carbon Dioxide Pressure Measurement after Prolonged Inspiratory Time Gives a Good Estimation of the Arterial Carbon Dioxide Pressure in Mechanically Ventilated Patients. Diagnostics. 2021; 11(12):2219. https://doi.org/10.3390/diagnostics11122219

Chicago/Turabian Style

Salomé, Arthur, Annabelle Stoclin, Cyrus Motamed, Philippe Sitbon, and Jean-Louis Bourgain. 2021. "End-Tidal Carbon Dioxide Pressure Measurement after Prolonged Inspiratory Time Gives a Good Estimation of the Arterial Carbon Dioxide Pressure in Mechanically Ventilated Patients" Diagnostics 11, no. 12: 2219. https://doi.org/10.3390/diagnostics11122219

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop