Reviewer 1 Report
The reviewed article contains interesting considerations. The extensive practical analysis of issues related to the spatial resolution and data integrity enhancement of microwave radiometer measurements using total variation deconvolution and bilateral fusion technique, but the current version need improved, for details se below:
- line 25-26, left column: give them the name of the author and the title of the article,
- add the extended state of the issue (the authors need to explain the difference between the current study and the available literature more precisely; use publications not older than 2-4 years),
- line 104: change “Table 1. Main characteristics of the FY3DMWRI” to “Table 1. Main characteristics of the FY3DMWRI.”,
- line 348: change “Figure 10.The evaluation” to “Figure 10. The evaluation”,
- line 482, Conclusions: expand your conclusions,
- page 20: add “Data Availability Statement”,
- References: is required Abbreviated Journal Name,
- References: include the digital object identifier (DOI) for all references where available,
- References: please format according to the journal guidelines
https://www.mdpi.com/files/word-templates/remotesensing-template.dot
In future publications, author should devote more time to editing the article according to the requirements of the journal. This will then avoid quite a number of insights into editing.
The reviewed article is a valuable publication. It can serve readers as a set of knowledge that can be used as a basis for further innovative and implementation studies.
Author Response
Please see the attachment
Author Response File: Author Response.docx
Reviewer 2 Report
Comments and suggested revisions are in the attached pdf.
Comments for author File: Comments.pdf
Author Response
Please see the attachment.
Author Response File: Author Response.docx
Reviewer 3 Report
Monor comments:
1. Keywords: should be FengYun instead Fengyun;
2. Line 68: should be Total Variation instead total variation;
3. Figures 6, 8, 10, 11, 13, 14, 16. Variables on the axes are not indicated
Author Response
Please see the attachment.
Author Response File: Author Response.docx