Next Article in Journal
Determinants of the Adoption of Climate-Smart Agricultural Practices by Small-Scale Farming Households in King Cetshwayo District Municipality, South Africa
Next Article in Special Issue
Organized Framework of Main Possible Applications of Sheep Wool Fibers in Building Components
Previous Article in Journal
Belt and Road Initiative (BRI): New Forms of International and Cross-Industry Collaboration for Sustainable Growth and Development
Previous Article in Special Issue
A Study on the Sustainability of the Traditional Sirinić Houses in the Šar Mountain Region, the South-Western Balkans
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Assessment of Passive Retrofitting Strategies to Improve the Thermal Performance of Extra-Virgin Olive Oil Storage Area in Traditional Rural Olive Mills

by
Francesco Barreca
* and
Pasquale Praticò
Department of Agraria, Università degli Studi Mediterranea di Reggio Calabria, 89122 Reggio Calabria RC, Italy
*
Author to whom correspondence should be addressed.
Sustainability 2020, 12(1), 194; https://doi.org/10.3390/su12010194
Submission received: 30 November 2019 / Revised: 23 December 2019 / Accepted: 23 December 2019 / Published: 25 December 2019
(This article belongs to the Special Issue The Exploration of Sustainability in Traditional Rural Buildings)

Abstract

:
The quality of extra-virgin olive oil (EVOO) is strongly correlated to the fatty acid alkyl esters (FAEE) content. High storage temperature leads to degradation of positive oil attributes in the long term, while low temperature develops rancidity quickly, thus reducing the consumer’s acceptance and, therefore, the shelf life of EVOO. In Calabria, there are many traditional olive mills, yet only few are utilized nowadays. This is mainly due to the low building performance—in particular to the temperature control inside the oil storage area. This paper illustrates the thermal analysis carried out on a famous historical olive mill located in Lamezia Terme, the best agricultural land in Calabria. A thermal retrofitting assessment was conducted, and eight different passive strategies were evaluated to improve the sustainability of the buildings.

1. Introduction

In the last 50 years, the crisis of industrial development has led researchers and government associations to become more interested in the traditional rural heritage [1].
Various European and national programmes and financial projects have dealt with the reuse and the valorisation of traditional rural buildings [2]. Their value is considered a social plus-value, because they are strongly linked to the local history, community and landscape of a territory. Unfortunately, owing to the great number of traditional rural buildings, many of which being abandoned or destroyed and to the limited public financial resources available, in Italy, the conservation of this important traditional heritage has become extremely difficult. Thanks to their potential uses, traditional rural buildings have attracted private entrepreneurs [3], who have demonstrated their capacity of reusing traditional rural buildings in different fields and activities: as tourist facilities, meeting places, conference halls, restaurants, hotels, museums, residential centres, recording studios and much more. To keep the original use of traditional rural buildings is often extremely difficult because of the increasing speed of technological innovation in agriculture and in food processing. In particular, modern food processing buildings require a greater number of performances than in the past. They need more flexibility in order to meet the consumer’s demand [4]. They have to be equipped with modern processing machines, to respect new food hygiene rules and to guarantee workers’ safety [5]. For all the above reasons, it is very important to define specific criteria to consider the rehabilitation of traditional rural buildings, since, in general, rehabilitating them costs much more than building modern ones. [6] Nowadays, one of the main operational difficulties in the rehabilitation of traditional buildings is the availability of craftsmen capable of working the local materials with traditional techniques. Nevertheless, reusing an old building on rural land can be advantageous for the local community since it can help protect the architectural heritage and conserve the regional landscape character as long as the new functions introduced are compatible with the original characteristics of the buildings. In fact, reuse is possible if it implies little intervention on the original building structure [7]. However, it is necessary to remark that modern rural buildings and food processing buildings are required to have particular indoor environmental characteristics because the indoor microclimate influences the chemical, physical and biological changes taking place during the production process [8,9].

2. Traditional Oil Mills in Calabria

Spain (1271 × 103 t) and Italy (429 × 103 t) are the main producers of olive oil in Europe and Italy is the major consumer of olive oil (560 × 103 t) [10].
Apulia, in Italy, is the first production region, with 33% of olive grove surface area, followed by Calabria, with 17% (184,000 ha), of which about 1550 ha are table olive groves and about 183 ha are oil olive groves, producing 140,000 tons of olive oil annually [11]. Olive trees are the most cultivated plants and the most important supply chain in Calabria, thus considerably contributing to the local rural economy [12]. The largest surface areas are in the provinces of Cosenza and Reggio Calabria [13]. In particular, the province of Reggio Calabria boasts the highest number of olive mills (304) and the highest quantity of olive oil production (26,555 t) [14].
In the mid-eighteenth century, following the technological improvement in agriculture and the innovation of the olive oil extraction machine (Grimaldi’s method), olive oil mills spread in the south of the region Calabria (Italy). There were two main production areas in Calabria in that period: one in the Gioia Tauro plain, in the province of Reggio Calabria, and the other near Lamezia Terme, in the province of Catanzaro (Figure 1).
In the Gioia Tauro Plain, production focused on husk oil, which was mainly used in the soap industry; while, in Lamezia Terme, production was oriented to high quality olive oil to use in food [15]. The architectural styles of the olive mills in these areas were also different: in the Gioia Tauro Plain, olive mills (type A) were characterized by a very simple architecture with a large plan equipped for getting the most out of the olive paste using washing techniques (Figure 2).
In the area of Lamezia Terme, olive mills (type B) were smaller and higher than in the Gioia Tauro Plain, with two floors to better store the olives on the first floor and to easily move them to the processing area on the ground floor without squeezing the olive fruits (Figure 3). The buildings were erected near streams so that, by means of a water wheel, they could use water energy to move the stone wheels that pressed the olives to obtain the oil.
The processing area was aired and lit by large windows with insect screens. The surface of the floor was in ceramic tiles or wood with a slight slope to let the cleaning water and the oil spilled out during the process drain away. In these buildings, the olive processing area was often divided into different levels: the mill and the presses were located in the upper area, while the containers with the just-pressed must/oil were in the lower area. In this area, the oil was separated from the water and transferred into a special room next to the mill, called chiaritoio. In this room, the oil was clarified by means of decanting cycles using terracotta churns. The olive oil was stored in big clay pots that were placed underground to protect them from high summer temperatures and by recurrent earthquakes [16] (Figure 4).
The indoor environment of the storage room influences the product quality. In particular, the temperature and the light of the storage environment could deteriorate the quality of extra-virgin olive oil (EVOO), which is strongly correlated to the fatty acid alkyl ester (FAEE) content. FAEE determines the organoleptic profile of an EVOO, which plays a relevant role in olive oil classification due to the fact that it is included in the quality parameters [17]. It has been demonstrated that a high FAAE concentration is the result of the use of olive fruits with fermentative alterations and high maturity index for oil extraction. A few studies have highlighted the relationship between FAEE in olive oil and the defects due to olive fermentation which affect its sensory classification. That is the reason why, in 2016, the European Commission Regulation defined the value of legal limit for the EVOO to 30 mg/kg. An incorrect storage temperature interval alters not only the FAEE of the olive oil but also other quality parameters, such as peroxide. In fact, high storage temperature, i.e., over 24 °C, leads to degradation of positive oil attributes in the long term, while low temperature develops rancidity quickly, thus reducing the consumer’s acceptance and, therefore, the shelf life of EVOO [18].
During the storage phase of EVOO, polyphenols tend to decrease and compromise its dietetic and nutritional qualities and taste as well as to produce harmful substances for human health [19]. Low storage temperature also affects the EVOO quality, though less than high storage temperature. Researchers noticed that, over a period of 15 days, storage temperature below 4 °C caused a decrease of about 50% of the total polyphenols compared to freshly made EVOO [20].
A typical Calabrian EVOO is produced with Carolea monovarietal olives, stored in stainless steel tanks placed in a dark environment for an average storage time of 12 months. The best range of temperature is from 8 to 22 °C [20].
Usually, the conservation stage is the major energy consumer in food processing, because the energy spent for product units is related to the time of conservation, which often exceeds one year. For these reasons, the thermal control of the EVOO storage environment is very important and the use of passive solutions could improve the energy savings of the production.
Reggio Calabria has a typical Mediterranean climate, with a mild temperature in winter (T > 0 °C) and warm summers (Tmax > 30 °C), with a strong day time and night time change of temperature. In the summer, the environmental indoor temperature of the EVOO mill storage area is often higher than 35 °C [8].
For this reason, it is very important to control the temperature of the storage environment in the EVOO mills in Calabria. The present study proposes the use of a passive retrofitting solution system on the building envelope.

3. Materials and Methods

The case study analysed is an olive mill which is part of a larger historic rural building complex located in Lamezia Terme, a town in the province of Catanzaro (38°55′20.593″ N 16°19′27.082″ E). This complex dates back to 1750 and it is one of the best preserved rural complexes in Calabria. The olive oil mill has a modern continuous milling system. The extra-virgin olive oil it produces is extracted from Carolea cultivar olives, exclusively grown in the company’s olive groves, which have an annual yield of about 50,000 L. These olive groves have been on this farm for over 300 years and many of the olive trees are hundreds of years old. The olive oil farm covers an area of 300 hectares including a hillside where there are some olive trees on the southern side of the hill. The Carolea olive tree is characterized by small, straight, narrow leaves and produces medium-sized olives which ripen around the middle of October. A high quality extra-virgin olive oil with an excellent organoleptic result is obtained from immediate milling after harvest. Milling starts in the early weeks of October and continues until March. The produced extra-virgin olive oil is kept in stainless steel tanks for a few months and then bottled during the year, according to the market demand.

The Olive Oil Mill Building

The olive oil mill is an ancient brick masonry building with a pitched roof in wood. The layout is very simple; the main processing area is a 50 × 8 m rectangle with a max 6 m height at the roof ridge. In the main area, there is the olive storage area, the pre-processing area with the machine for fruit handling and receival and the machine for removing leaves and washing the drupes. Next to this area, there is the processing area with the crushing and malaxing machines and the oil separation machine (Figure 5). Adjacent to the processing area, there is the service area with a little laboratory for the olive oil analysis, the workers’ restroom and the olive oil storage area. The olive oil storage area is a 7 × 4 m room with an external window without any separation from the main processing area.
The external wall and the window of the storage area are oriented to the south–west. Since this is the part of the building most exposed to sun radiation, in the summer, its indoor temperature is very hot. Specific thermal surveys were carried out [21] to evaluate the thermal indoor condition. In particular, an instrumental analysis was carried out from 19 July to 29 September 2016 to intercept the hottest summer season period. Two surface temperature sensors and two heat flow sensors were installed on the surface of internal walls (T5–F2), while two other pairs of heat flow meters and surface heat sensors were installed on the ceiling and on the roof indoor surface (Tf–Ff; Tr–Fr). Two temperature sensors (T1–T2) were mounted on the surface of external walls and a first class pyranometer for solar irradiance measurement, according to ISO 9060 (Figure 6a) (P), was mounted on the external window. The indoor air temperature was surveyed by means of two specific sensors mounted on two tripods, one located in the centre of the room (Ta) and the other in the attic (Tar). Another surface temperature sensor was installed on the olive oil stainless steel tank (T3). A weather station was placed close to the building to survey the meteorological data (Figure 6b). All the data surveyed by the sensor network were recorded at a time interval of 15 min by a data logger [22]. The surveyed data showed that, during the monitoring period, the temperature in the oil storage area was sometimes above 30 °C, a value far higher than the maximum correct temperature for the proper storage of extra-virgin olive oil.

4. Results

The measured thermal values showed that, during the monitoring period, the indoor air temperature in the oil storage area sometimes reached and exceeded 30 °C and that the building offered inadequate protection from high summer temperatures (Figure 7).
It was necessary to design and verify specific retrofitting solutions to improve the thermal performance of the building.
The thermal analysis of the case-study building was carried out by means of DesignBuilder, a building energy simulation software based on a dynamic thermal simulation method (DTS) [23]. DTS is a method used to predict the way a building responds when subject to external environmental factors. To achieve this, all necessary parameters of design are taken into consideration, such as: occupancy patterns, internal heat gains and building fabric characteristics that could affect the result [24]. It is very important to consider the influence of environmental factors affecting the indoor environment, which depend on weather conditions that are variable during the day and during the yearly seasons. The heat flow through walls is determined not just by the area and the temperatures, but also by the mass characteristics of the walls, which may result in heat flowing out of a wall several hours later [25,26]. Solar energy is absorbed by the exterior walls and roof surfaces as well as through windows. The intensity of solar energy varies according to the position of the sun during the day and over the year. In addition, the ground and the ground floor are an infinite thermal source which has a constant temperature and exchanges heat with the indoor environment [27]. Heat sources within the building, including people, office and other equipment, have an immediate impact on the indoor air (convective heat) and the heat that is absorbed by the surfaces is released slowly over time (radiant heat) [28]. Air conditioning and heating systems can also be used with many different control systems based on the temperature or other conditions within each space of the building and their operation accounts for a large portion of the energy consumed in a building. By means of Energy+, the dynamic simulation engine of DesignBuilder, it was possible to consider all these parameters and estimate the indoor temperature and the energy spent by an HAVC system to maintain the optimal olive oil storage temperature in the range (8–21 °C) suitable to guarantee the quality of the EVOO produced (Figure 8) [29].
The results of the building analysis (model A) highlighted that the indoor temperature was never below 8 °C, but, during the summer, it was often over 21 °C. For this reason, the energy spent was only to cool the indoor environment of the olive oil storage room. Seven different building retrofitting solutions were analysed to assess the best energy saving solution.
Solution 1: the oil storage area was separated from the processing area by means of a 6 cm thick polyurethane wall sandwich panel.
Solution 2: the external wall was shaded by outdoor shading elements.
Solution 3: the walls and the roof of the olive oil storage room were insulated by 6 cm thick polyurethane panels (Figure 9) and the external window was eliminated.
Solution 4: a space ventilation was made on the roof and natural ventilation was activated from 20:00 to 08:00.
Solution 5: a Canadian well was installed to ventilate indoors from 20:00 to 08:00.
Solution 6: an internal fan was installed to force ventilation from 20:00 to 08:00.
Solution 7: the walls and the roof of the olive oil storage were insulated by means of an 18 °C phase change material layer.
The energy analysis was carried out considering building models with different combinations of solutions. In particular, model A was the real building without any retrofitting intervention; model I was the model with the external wall shaded by means of outdoor shading elements and the wall and roof insulated by means of a 18 °C phase change material layer; the other models analysed were the different combinations of the solutions mentioned above (Table 1).
The dynamic thermal analysis was carried out considering the closest World Meteorological Organization (WMO) weather located about 35 km west from the case study (38°12′ N, 15°33′ E). The weather file is part of the Italian Climate Data Set elaborated by Gianni de Giorgio with yearly data from 1951 until 1970.
For each building energy model, a specific energy simulation was carried out to assess the energy spent by an electric HAVC to obtain the mean environmental temperature of 21 °C inside the olive oil storage room.
The results of the daily thermal simulation are shown in Figure 10, while the energy spent for each model is shown in Figure 11.

5. Discussion

The energy spent to maintain the temperature below 21 °C inside the original olive oil storage room by means of a HAVC system was about 4161 KW/year (model A), while for the other models, which adopted the passive retrofitting, it was lower. The analysis highlighted a great difference in the results between the models considered. In solution 3, it was possible to notice that the insulation of the roof and of the wall of the building with 6 cm thick polyurethane panels (Figure 9), and the removal of the external window (considered in model D-E-F-G), improved the energy performance of the building of about 80% compared to model C, which had a simple partition separating the EVOO storage room from the processing area and a shading effect produced by the outdoor shading element. Moreover, models with the Canadian well installation, such as model G, did not allow lower energy consumption; on the contrary, they increased the energy consumption of about 25%, especially in model F. The possible reason could be that the Canadian carried external hot air well, exceeding 21 °C, into the olive oil storage room. However, the most interesting result was that the insulation of the olive oil storage walls and roof by means of an 18 °C phase change material layer (model H) did not improve energy saving compared to model F, which did not have any PCM layer. This is due to the fact that stone walls have a high thermal capacity and, therefore, an increase in the building walls thermal inertia by means of PCM was negligible. The olive oil storage room with insulated walls and roof by means of a 18 °C phase change material layer, separated from the processing area and with external wall shaded by outdoor shading elements (model I) allowed an energy saving similar to model C. model E showed the best energy saving. In this model, there were some passive retrofitting solutions, such as: a simple partition separating the EVOO storage room from the processing area; a shading effect produced by the outdoor shading system; roof and wall insulation of the olive oil storage room with 6 cm thick polyurethane panels; removal of the external window; and natural roof ventilation. The analysis of this model showed an energy saving over 90% compared to the original olive oil mill model (model A). However, using only the separation of the EVOO storage room from the processing area and the insulation of the roof and walls of the olive oil room allowed an energy saving of more than 80%.

6. Conclusions

The retrofitting of ancient rural buildings needs a specific energy analysis because their structures and materials have anomalous behaviours compared to new buildings, which are used differently from how they were in the past. Modern building solutions are not always appropriate to increase the performance of old traditional rural buildings. This is often due to the building materials used in the past, because they have different physical properties compared to modern building materials. For example, the solution with the use of PCM (solution 7) showed good results in improving the thermal performance in modern buildings [9]. By means of this material, it is possible to obtain a great thermal inertia for the envelope, but, in traditional old rural buildings, the walls of stones already have a big thermal mass. The functions of modern rural buildings and food processing buildings are different from the past, because, lately, new food safety and quality laws have been introduced and the indoor environment characteristics also influence the chemical, physical and biological changes that take place during the production process, especially during the storage stage. In this paper, an ancient olive oil mill building was studied and different passive retrofitting strategies were considered and analysed.
The study highlights the best efficient retrofitting strategy, which was the thermal insulation of the walls and roof of the storage room, because the old rural building had massive stone walls with high thermal capacity but low thermal resistance. Future work will evaluate the economic advantage and return on investment related to cost of retrofit measures.

Author Contributions

F.B. developed the methodology and wrote the paper, P.P. collaborated in developing the literature review, data acquisition and analysis under the supervision of F.B. All authors have read and agreed to the published version of the manuscript.

Funding

This research was partly funded by project PON03PE_00090_2, in the framework of National Operational Programme (NOP) for Research and Competitiveness 2007–2013 of the Italian Ministry of Edu-cation, University and Research (MIUR) and Ministry of Economic Development (MiSE) and co-funded by the European Regional Development Fund (ERDF).

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Di Fazio, S. Vernacular architecture: A threatened heritage to protect and a resource for rural development. In Proceedings of the 9th International Scientific Conference “Tusnad 2000: Built Heritage and Society”, Cluj-Napoca, Romania, 5–7 April 2000; Foundation, T.T., Ed.; Utilitas: Tusnad, Romania, 2000; pp. 10–24. [Google Scholar]
  2. Kelliher, F.; Reinl, L.; Johnson, T.G.; Joppe, M. The role of trust in building rural tourism micro firm network engagement: A multi-case study. Tour. Manag. 2018, 68, 1–12. [Google Scholar] [CrossRef]
  3. Picuno, P.; Cillis, G.; Statuto, D. Investigating the time evolution of a rural landscape: How historical maps may provide environmental information when processed using a GIS. Ecol. Eng. 2019, 139, 105580. [Google Scholar] [CrossRef]
  4. Dal Sasso, P.; Caliandro, L.P. The role of historical agro-industrial buildings in the study of rural territory. Landsc. Urban Plan. 2010, 96, 146–162. [Google Scholar] [CrossRef]
  5. Barreca, F.; Cardinali, G.; Fichera, C.R.; Lamberto, L.; Modica, G. A fuzzy-based model to implement the global safety buildings index assessment for agri-food buildings. J. Agric. Eng. 2014, 45. [Google Scholar] [CrossRef] [Green Version]
  6. Statuto, D.; Tortora, A.; Picuno, P. A GIS approach for the quantification of forest and agricultural biomass in the Basilicata region. J. Agric. Eng. 2013, 44, 627–631. [Google Scholar] [CrossRef]
  7. Barreca, F.; Martinez Gabarron, A.; Flores Yepes, J.A.; Pastor Pérez, J.J. Innovative use of giant reed and cork residues for panels of buildings in Mediterranean area. Resour. Conserv. Recycl. 2019, 140, 259–266. [Google Scholar] [CrossRef]
  8. Barreca, F.; Praticò, P. Post-Occupancy Evaluation of Buildings for Sustainable Agri-Food Production—A Method Applied to an Olive Oil Mill. Buildings 2018, 8, 83. [Google Scholar] [CrossRef] [Green Version]
  9. Barreca, F.; Praticò, P. Environmental indoor thermal control of extra virgin olive oil storage room with phase change materials. J. Agric. Eng. 2019, 947, 208–214. [Google Scholar] [CrossRef]
  10. Valenti, F.; Porto, S.; Cascone, G.; Arcidiacono, C. Potential biogas production from agricultural by-products in Sicily: A case study of citrus pulp and olive pomace. J. Agric. Eng. 2017, 48. [Google Scholar] [CrossRef] [Green Version]
  11. Unaprol. Filiera Olivicola-Analisi di Scenario; Unaprol: Roma, Italy, 2016. [Google Scholar]
  12. Stillitano, T.; De Luca, A.I.; Iofrida, N.; Falcone, G.; Spada, E.; Gulisano, G. Economic analysis of olive oil production systems in southern Italy. Calitatea 2017, 18, 107–112. [Google Scholar]
  13. Bernardi, B.; Falcone, G.; Stillitano, T.; Benalia, S.; Bacenetti, J.; Irene, A.; Luca, D. Science of the Total Environment Harvesting system sustainability in Mediterranean olive cultivation. Sci. Total Environ. 2018, 625, 1446–1458. [Google Scholar] [CrossRef] [PubMed]
  14. Abenavoli, L.M.; Proto, A.R. Effects of the divers olive harvesting systems on oil quality. Agron. Res. 2015, 13, 7–16. [Google Scholar]
  15. De Luca, A.I.; Falcone, G.; Stillitano, T.; Iofrida, N.; Gulisano, G. Evaluation of sustainable innovations in olive growing systems: A Life Cycle Sustainability Assessment case study in southern Italy. J. Clean. Prod. 2018, 171. [Google Scholar] [CrossRef]
  16. Fichera, C.R.; Di Fazio, S.; Bonomo, G. Old factory buildings for the production of olive oil in Calabria. Current situation and conservation strategies. In International Conference on “Vernacular architectural heritage”; Foundation, T.T., Ed.; Utilitas Publisher: Cluj, Romania, 1999; pp. 103–108. [Google Scholar]
  17. Gómez-Coca, R.B.; Fernandes, G.D.; del Pérez-Camino, M.C.; Moreda, W. Fatty acid ethyl esters (FAEE) in extra virgin olive oil: A case study of a quality parameter. LWT Food Sci. Technol. 2016, 66, 378–383. [Google Scholar] [CrossRef] [Green Version]
  18. Ayton, J.; Mailer, R.; Kerrie, G. The Effect of Storage Conditions on Extra Virgin Olive Oil Quality; Kingston: Fountain Valley, CA, USA, 2012. [Google Scholar]
  19. Lo Curto, S.; Dugo, G.; Mondello, L.; Errante, G.; Russo, M.T. Variation in tocopherol content in Italian virgin olive oils. Ital. J. Food Sci. 2001, 13, 221–228. [Google Scholar]
  20. Piscopo, A.; Poiana, M. Packaging and Storage of Olive Oil. In Olive Germplasm—The Olive Cultivation, Table Olive and Olive Oil Industry in Italy; IntechOpen: London, UK, 2012. [Google Scholar] [CrossRef] [Green Version]
  21. Porto, S.M.C.; Valenti, F.; Cascone, G.; Arcidiacono, C. Thermal insulation of a flour mill to improve effectiveness of the heat treatment for insect pest control. Agric. Eng. Int. CIGR J. 2015, 2015, 94–104. [Google Scholar]
  22. Barreca, F.; Modica, G.; Di Fazio, S.; Tirella, V.; Tripodi, R.; Fichera, C.R. Improving building energy modelling by applying advanced 3D surveying techniques on agri-food facilities. J. Agric. Eng. 2017, 48, 203–208. [Google Scholar] [CrossRef] [Green Version]
  23. Day, J.K.; Gunderson, D.E. Understanding high performance buildings: The link between occupant knowledge of passive design systems, corresponding behaviors, occupant comfort and environmental satisfaction. Build. Environ. 2015, 84, 114–124. [Google Scholar] [CrossRef]
  24. Porto, S.M.C.; Valenti, F.; Bella, S.; Russo, A.; Cascone, G.; Arcidiacono, C. Improving the effectiveness of heat treatment for insect pest control in flour mills by thermal simulations. Biosyst. Eng. 2017, 164, 189–199. [Google Scholar] [CrossRef]
  25. Barreca, F.; Fichera, C.R. Wall panels of Arundo donax L. for environmentally sustainable agriculture buildings: Thermal performance evaluation. J. Food Agric. Environ. 2013, 11, 1353–1357. [Google Scholar]
  26. Barbaresi, A.; De Maria, F.; Torreggiani, D.; Benni, S.; Tassinari, P. Performance assessment of thermal simulation approaches of wine storage buildings based on experimental calibration. Energy Build. 2015, 103, 307–316. [Google Scholar] [CrossRef]
  27. Barbaresi, A.; Torreggiani, D.; Benni, S.; Tassinari, P. Underground cellar thermal simulation: Definition of a method for modelling performance assessment based on experimental calibration. Energy Build. 2014, 76, 363–372. [Google Scholar] [CrossRef]
  28. Faye, M.; Lartigue, B.; Sambou, V. A new procedure for the experimental measurement of the effective heat capacity of wall elements. Energy Build. 2015, 103, 62–69. [Google Scholar] [CrossRef]
  29. Dabaieh, M.; Wanas, O.; Hegazy, M.A.; Johansson, E. Reducing cooling demands in a hot dry climate: A simulation study for non-insulated passive cool roof thermal performance in residential buildings. Energy Build. 2015, 89, 142–152. [Google Scholar] [CrossRef] [Green Version]
Figure 1. Main olive oil production areas in the mid-eighteenth century in Calabria.
Figure 1. Main olive oil production areas in the mid-eighteenth century in Calabria.
Sustainability 12 00194 g001
Figure 2. Typical olive oil mill in Gioia Tauro (type A). (a) Facade (b) Layout.
Figure 2. Typical olive oil mill in Gioia Tauro (type A). (a) Facade (b) Layout.
Sustainability 12 00194 g002
Figure 3. Typical olive oil mill in Lamezia Terme (type B). (a) Facade (b) Layout.
Figure 3. Typical olive oil mill in Lamezia Terme (type B). (a) Facade (b) Layout.
Sustainability 12 00194 g003
Figure 4. Chiaritoio with clay pot placed underground to store olive oil.
Figure 4. Chiaritoio with clay pot placed underground to store olive oil.
Sustainability 12 00194 g004
Figure 5. Layout of the olive oil mill.
Figure 5. Layout of the olive oil mill.
Sustainability 12 00194 g005
Figure 6. (a) Installed instrumental network; (b) outdoor weather station.
Figure 6. (a) Installed instrumental network; (b) outdoor weather station.
Sustainability 12 00194 g006
Figure 7. Outdoor and indoor measured air temperature.
Figure 7. Outdoor and indoor measured air temperature.
Sustainability 12 00194 g007
Figure 8. Temperature inside the olive oil storage room (model A).
Figure 8. Temperature inside the olive oil storage room (model A).
Sustainability 12 00194 g008
Figure 9. Solution 3: the stone wall of the olive oil storage area insulated by 6 cm thick polyurethane panels.
Figure 9. Solution 3: the stone wall of the olive oil storage area insulated by 6 cm thick polyurethane panels.
Sustainability 12 00194 g009
Figure 10. Daily energy spent by HAVC to cool the olive oil storage room for different building models.
Figure 10. Daily energy spent by HAVC to cool the olive oil storage room for different building models.
Sustainability 12 00194 g010
Figure 11. Yearly energy spent by HAVC to cool the olive oil storage room by different building models.
Figure 11. Yearly energy spent by HAVC to cool the olive oil storage room by different building models.
Sustainability 12 00194 g011
Table 1. Models analysed obtained from the different combinations of the proposed solutions.
Table 1. Models analysed obtained from the different combinations of the proposed solutions.
OriginalSOL 1SOL 2SOL 3SOL 4SOL 5SOL 6SOL 7
MODEL Sustainability 12 00194 i001 Sustainability 12 00194 i002 Sustainability 12 00194 i003 Sustainability 12 00194 i004 Sustainability 12 00194 i005 Sustainability 12 00194 i006 Sustainability 12 00194 i007 Sustainability 12 00194 i008
AX
B X
C XX
D XXX
E XXXX
F XXXXX
G XXXXXX
H XXXXXXX
I XX X

Share and Cite

MDPI and ACS Style

Barreca, F.; Praticò, P. Assessment of Passive Retrofitting Strategies to Improve the Thermal Performance of Extra-Virgin Olive Oil Storage Area in Traditional Rural Olive Mills. Sustainability 2020, 12, 194. https://doi.org/10.3390/su12010194

AMA Style

Barreca F, Praticò P. Assessment of Passive Retrofitting Strategies to Improve the Thermal Performance of Extra-Virgin Olive Oil Storage Area in Traditional Rural Olive Mills. Sustainability. 2020; 12(1):194. https://doi.org/10.3390/su12010194

Chicago/Turabian Style

Barreca, Francesco, and Pasquale Praticò. 2020. "Assessment of Passive Retrofitting Strategies to Improve the Thermal Performance of Extra-Virgin Olive Oil Storage Area in Traditional Rural Olive Mills" Sustainability 12, no. 1: 194. https://doi.org/10.3390/su12010194

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop