2. Literature Review
Many studies can be found on the relationship between green certifications and indoor environmental quality (IEQ) investigating occupant satisfaction with factors such as thermal comfort, air quality, lighting, and noise. There are also papers considering other parameters in relation to building design and facilities management (BD&FM) such as privacy, environmental control, cleanliness, operation and maintenance, design, aesthetics, image, needs, ease of interaction with co-workers, furniture, health, and productivity.
The available survey data from the Centre of the Built Environment (CBE) at the University of Berkley in California have been used in several studies analyzing LEED (Leadership in Energy and Environmental Design) buildings [
5,
9,
10,
11], resulting in a large amount of data being used in these papers. In terms of thermal comfort satisfaction, most studies detected a higher performance in LEED buildings compared with in conventional buildings. However, several studies indicated no significant difference in the thermal performance of LEED and non-LEED buildings [
5]. Indoor air quality (IAQ) was also perceived more satisfactory in LEED buildings when compared with non-green buildings [
9,
10,
11,
12,
13]. The lighting and noise performance of LEED buildings showed significant inconsistency in the literature. In terms of lighting performance in LEED buildings, most papers detected no significant differences [
5,
9,
11]. However, two studies indicated a higher satisfaction score [
12,
13], and two papers [
10,
14] reported a lower satisfaction score in LEED buildings. As reflected in the literature, LEED buildings are the least successful in terms of noise performance as the majority of papers either reported no significant differences [
5,
9,
11], or lower satisfaction scores [
10,
12,
14] in LEED buildings in comparison with in non-LEED buildings. One paper [
15], however, reported a higher satisfaction score in overall noise performance of LEED buildings, and another study [
15] indicated that noise from HVAC (Heating, ventilation, and air conditioning) was perceived to be more satisfactory in LEED buildings. Abbaszade et al. [
9] emphasized the necessity for improvements in lighting controls and sound privacy through the accommodation of innovative strategies in open-plan offices in both LEED and non-LEED buildings. In terms of BD&FM, most papers [
10,
13,
14,
15] reflected a more satisfactory performance in LEED buildings.
Studies focused on BREEAM (Building Research Establishment Environmental Assessment Method) (the most common certification tool in Europe) reflected an inconsistent result in analyzing various IEQ and BD&FM parameters. In terms of overall thermal performance, two studies [
16,
17] reported lower satisfaction scores, while another paper [
3] showed satisfaction scores were comparable in BREEAM and non-BREEAM buildings with no significant differences. All papers studying IAQ [
3,
18] reported lower satisfactory results in BREEAM buildings compared with in their conventional counterparts. Lighting performance in BREEAM buildings, however, was slightly better than other IEQ parameters, as two papers [
16,
17] detected higher and two papers [
3,
18] reported no significant differences in satisfaction in the green and non-green groups. No significant differences in the noise performance of BREEAM and non-BREEAM buildings were perceived according to the literature [
3,
16,
17,
18]. In one study [
18], noise from outside was scored lower in BREEAM buildings than in non-green buildings. One study [
3] reported that the satisfaction results in BREEAM and non-BREEAM buildings were not significantly different, particularly in regard to sound privacy, the ease of interaction with colleagues, cleanliness, and workplace satisfaction. The study also reported a lower satisfaction level in visual privacy in BREEAM-certified buildings compared with in conventional buildings [
3]. Indoor environmental controls in BREEAM buildings scored no significant differences in the two compared groups [
16]. In one study [
16], operation and maintenance achieved higher satisfaction in BREEAM buildings when compared with their conventional counterparts.
Some studies have investigated Green Star buildings in Australia, and have particular relevance for our study. Some papers reported no significant differences in the performance of Green Star buildings compared with conventional buildings, particularly in overall perceived thermal comfort [
19,
20], lighting [
19], ventilation [
19], and noise [
19] performance. In another Australian-based study [
21], a wide spectrum of Green Star building performances was evident, with some high-profile green buildings outperforming their conventional counterparts, but some green buildings underperformed when compared with conventional buildings. The same study [
18] reported less satisfactory performances for Green Star buildings by showing green buildings underperforming their conventional counterparts in terms of thermal comfort satisfaction and perceived productivity. The study [
21] also demonstrated that Green Star buildings generally outperformed the conventional buildings in terms of perceived health, building image, and addressing occupant needs.
5. Results
5.1. IEQ Satisfaction
Figure 2 compares green and non-green buildings in terms of IEQ satisfaction. It shows similarities and differences between the two groups. The inferential
t-test revealed statistically significant differences between the performance of Green Star and conventional buildings in terms of most IEQ parameters, particularly in overall thermal comfort (
p-value = 0.004 in winter;
p-value = 0.001 in summer), overall air satisfaction (
p-value = 0.000 in winter;
p-value = 0.000 in summer), and overall noise satisfaction (
p-value = 0.006). Green buildings outperformed conventional buildings in thermal (ΔM = 0.34 in winter; ΔM = 0.54) and IAQ parameters (ΔM = 0.52 in winter; ΔM = 0.68 in summer). In terms of noise, conventional buildings outperformed Green Star buildings (ΔM = −0.45). No significant differences in lighting scores (
p-value = 0.301) were detected in the two comparison groups. The IAQ and thermal performance of green buildings scored slightly higher in summer (ΔM = 0.68 in IAQ; ΔM = 0.54 in thermal) than in winter (ΔM = 0.52 in IAQ; ΔM = 0.34 in thermal).
A more detailed analysis of the 27 IEQ parameters showing the mean values, standard deviations, the difference in standard errors, the difference in mean values, effect sizes, and the statistical significances (
p-value) of satisfaction scores in Green Star and conventional buildings is presented in
Table 6. Numbers in bold italics show statistically significant
t-tests with
p-values less than 0.05, and substantive effect sizes with values more than 0.20.
Green buildings achieved significantly higher satisfaction in some IEQ parameters including overall air in summer (Rho = 0.35), overall comfort in summer (Rho = 0.28), air dryness in winter (Rho = 0.22), overall air in winter (Rho = 0.26), air movement in winter (Rho = 0.35), natural light (Rho = 0.31), and inside noise (Rho = 0.30).
However, the green building set gained lower satisfaction scores in a number of IEQ parameters, such as air freshness in both summer (Rho = −0.44) and winter (Rho = −0.36), air odors in summer (Rho = −0.26), artificial lighting (Rho = −0.22), and overall noise (Rho = −0.22). The maximum differences in the mean values of satisfaction scores belonged to air freshness in summer with a negative difference in mean values of −0.81 (the mean score of green buildings minus the mean score of conventional buildings), and air overall in summer with a positive difference in mean values of 0.68.
The inferential tests showed that users of Green Star and non-Green Star buildings had similar satisfaction scores, with p-value more than 0.05 in regard to some IEQ factors, such as temperature in winter (Rho = −0.05), temperature stability in winter (Rho = −0.05), air odors in winter (Rho = −0.14), air movement in summer (Rho = 0.12), air dryness in summer (Rho = −0.01), noise from colleagues (Rho = 0.03), noise from outside (Rho = 0.14), unwanted interruptions (Rho = 0.03), overall lighting (Rho = 0.07), and glare from natural lighting (Rho = 0.16).
In regard to IEQ parameters, the comparative analysis of satisfaction scores in green and conventional buildings detected a significant correlation between Green Star certifications and occupant satisfaction with workplace environments.
5.2. BD&FM Satisfaction
Figure 3 compares green and non-green buildings in terms of BD&FM satisfaction. The mean satisfaction scores, standard deviations, the difference in standard errors, mean differences, effect sizes, and statistical significances of satisfaction scores regarding BD&FM parameters are presented in
Table 7. Figures in bold italics show statistically significant
t-tests with
p-values less than 0.05, and substantive effect sizes with values more than 0.20.
In terms of BD&FM factors, green buildings had significantly higher scores compared with non-green buildings, particularly in parameters such as image (Rho = 0.84) and cleaning (Rho = 0.81) with large effect sizes. With medium effect sizes, health (Rho = 0.47) and productivity (Rho = 0.22) scored higher in green buildings than in their conventional counterparts. The maximum difference in mean satisfaction scores regarding BD&FM parameters belonged to image (ΔM = 1.65), and cleaning (ΔM = 1.55), both with positive values in mean differences (the mean score of green buildings minus the mean score of conventional buildings).
These results confirm that the green building users were more significantly satisfied than the non-green building users with most BD&FM parameters, such as design, needs from facilities, building image, cleaning, the availability of meeting rooms, and storage. Perceived productivity and health was also reported higher in green buildings. Although occupant satisfaction was higher in green buildings, there were also more reported requests to fix problems in these buildings. This suggests that expectations and hopes of fixing problems are higher in green buildings than in conventional buildings. In green buildings, the most common complaint was noise, whereas in conventional buildings, more complaints about HVAC systems and temperatures were reported.
5.3. The Influence of Environmental Factors
To study the effect of indoor environmental factors on satisfaction scores, we conducted pairwise correlation studies to analyze the influence of individual controls and ventilation types.
5.3.1. Individual Control
Although research has shown that personal control could significantly improve thermal comfort perceptions [
33], the extent and comparison of the effect of personal controls in green and non-green buildings has not been studied. We analyzed the impact of perceived individual controls on satisfaction scores concerning five parameters including heating, cooling, ventilation, lighting, and noise. A pairwise correlation analysis showing the relationship between the following parameters is presented in
Table 8: (1) heating control and thermal comfort in winter; (2) cooling control and thermal comfort in summer; (3) ventilation control and overall air quality satisfaction; (4) lighting control and overall lighting satisfaction; and (5) noise control and overall noise satisfaction.
Perceived controls in all five parameters were only significantly correlated with satisfaction scores in non-green buildings. Perceived heating control had a significant correlation (p-value = 0.000) with thermal comfort satisfaction in winter in non-green buildings, while no significant correlations were found between perceived heating control and winter thermal comfort in green building group. Cooling control was also strongly correlated with summer thermal comfort in the non-green building set (p-value = 0.000). Ventilation control significantly influenced overall air satisfaction (p-value = 0.018) in non-green buildings. Perceived control over lighting and noise in non-green buildings significantly correlated with satisfaction with overall lighting (p-value = 0.000) and acoustics (p-value = 0.000), whereas in green buildings, no significant correlations were detected between perceived control and satisfaction.
5.3.2. Ventilation
This section reports the results of the influence of ventilation systems on occupant satisfaction in the green and non-green buildings. The difference in mean scores, effect sizes, and correlation significances is reported in
Table 9.
In thermal comfort, green buildings outperformed non-green air-conditioned (AC) buildings, while in mixed-mode (MM) buildings, no differences were detected in the thermal performance of the two comparison groups (green and non-green). In AC buildings, satisfaction with overall IAQ achieved higher scores in green buildings compared with in non-green buildings. Overall IAQ in MM buildings achieved comparable scores in green and non-green buildings. In terms of overall IAQ, the performance of green buildings in winter was perceived to be more satisfactory than in summer. In winter, indoor air was scored significantly more humid in AC green buildings and more stable in MM green buildings. In terms of air freshness, no significant differences in MM buildings were detected; nevertheless, non-green AC buildings achieved higher air freshness scores compared with green AC buildings.
This analysis showed that ventilation type affected satisfaction scores. The green buildings which had AC systems underperformed non-green buildings in terms of air freshness. Overall IAQ and overall thermal comfort in AC green buildings scored significantly higher when compared with non-green buildings, while no significant differences in overall scores were detected in MM buildings.
5.4. The Influence of Non-Environmental Factors
To conduct a deeper analysis of the results, the influence of non-environmental factors such as age, gender, being close to a window, houses spent in the building and in the workstation, and number of people sharing office space was analyzed (
Table 10). Statistical analysis of the mean comparison test was undertaken and effect sizes were calculated to explore whether non-environmental factors significantly affected satisfaction in green and non-green buildings.
The analysis of age groups (under 30, and 30 or above) revealed that for the group aged under 30, no statistical difference in satisfaction scores was detected between green and non-green buildings (Rho = −0.09). However, for the group aged 30 or above, the green building group achieved slightly higher satisfaction scores than the non-green building group (Rho = 0.28), suggesting that participant age might have an influence on satisfaction scores when comparing green and non-green buildings.
The statistical analysis of t-tests and the effect size of mean differences showed that gender had no significant influence on occupant satisfaction in Green Star and non-Green Star buildings. Negligible effect sizes were detected for both gender groups of male (Rho = 0.14 and p-value = 0.256) and female (Rho = 0.18 and p-value = 0.212).
As participants were divided into two groups of sitting next to a window and not sitting next to a window, a small difference in the performance of green and non-green buildings was detected among participants in the group of sitting next to a window. A small effect size of mean differences between satisfaction scores in green and non-green buildings was observed in the group of sitting next to a window (Rho = 0.27 and p-value = 0.051). This suggests that the performance of green and non-green buildings was comparable among participants who sit far from a window, whereas green buildings achieved slightly higher scores from participants who sit next to a window.
To investigate the effect of the length of time occupants had been working in their current buildings and workstations, participants were grouped into two groups of less than a year, and a year or more. Participants who had been working in their buildings for a year or more reflected significant differences in satisfaction scores (Rho = 0.39 and p-value = 0.002) between green and non-green buildings, whereas for those who had worked in their current building for less than a year, satisfaction scores were comparable in green and non-green buildings (Rho = 0.08 and p-value = 0.698). Similar results were found in regard to time spent in workstations, showing that participants who spent less than one year in their workstations reflected no significant differences between green and non-green buildings. High statistical differences between satisfaction scores in green and non-green buildings were marked by participants who spent a year or more in their workstations (Rho = 0.40 and p-value = 0.002). This finding showed that becoming used to changes and settling down in current workplaces affects occupant satisfaction and should be considered as an influential factor when comparing green and non-green buildings.
To explore the effect of office sharing on occupant satisfaction, the five office sharing conditions were as follows: Type 1, used only by one person; Type 2, used by two people; Type 3, used by three to five people; Type 4, used by six to nine people; and Type 5, used by more than nine people. An analysis of satisfaction scores in regard to office sharing with colleagues showed that participants in Type 5 delivered significantly higher scores in green buildings compared with in non-green buildings (Rho = 0.24 and
p-value = 0.000). Although the effect sizes for Type 2 and Type 4 were more than 0.20, the p-values showed that the results were not statistically significant. The effect size for Type 2 was large (Rho = 0.82), while the
p-value was 0.177. Similarly, for Type 4, the effect size was just above 0.20 (Rho = 0.21) showing a small effect size, but the
p-value (0.422) showed that the findings were not statistically significant. This can be explained by the sample size presented in
Table 11. The sample sizes, particularly in the green building groups for Type 2 (sample size = 3) and Type 4 (sample size = 18), were small.
These findings suggest that office sharing affects occupant experiences of buildings and thus influences satisfaction scores when comparing green and non-green buildings. Due to the sample sizing, the comparison of Types 2, 3, and 4 showed no statistically significant results. For Types 1 and 5, sample sizes were comparable, suggesting that green buildings were more favorable among participants in Type 5, whereas no significant differences between green and non-green buildings were reflected by occupants in Type 1.
6. Discussion
This study compared the occupant satisfaction and perceived indoor environmental conditions of Green Star higher education office buildings with their conventional counterparts regarding several IEQ and BD&FM parameters. The two comparison building groups were consistent in terms of building size, year of construction or renovation, climate, function, cultural background, urban setting, and data collection period. This study showed that Green Star buildings were more successful in delivering satisfactory workplace environments regarding some IEQ and BD&FM parameters, while some weaknesses were also detected that showed occupant dissatisfaction with Green Star buildings.
The results support Hypothesis 1 that on BD&FM, Green Star buildings consistently showed a better performance compared with non-green buildings, particularly with overall building comfort, building design, needs, building image, cleaning, availability of meeting rooms, and storage space. Higher perceived health and productivity were found in Green Star buildings. This agrees with findings from previous studies [
14,
21,
34].
The results also support Hypothesis 2 that on IEQ satisfaction, green buildings outperforming non-green buildings is inconclusive. It was shown that the occupants of Green Star buildings were more satisfied with thermal comfort and overall IAQ, a finding which is supported by previous studies [
4,
13,
29,
35,
36,
37]. Participants reflected slightly higher satisfaction with the winter performance of Green Star buildings. In winter, satisfaction scores were higher in Green Star buildings for air movement and humidity when compared with non-green buildings, while in summer, non-green buildings achieved a higher score for air odors when comparing Green Star with non-green buildings. This might be explained by the Australian subtropical climate holding more suitable conditions for natural ventilation in winter than in summer due to high humidity. Air freshness was also scored significantly lower in Green Star buildings than in conventional buildings. This could be explained by the lack of fresh air penetration through ventilation openings in the Green Star buildings.
Our study also confirmed lower satisfaction levels with noise in green-rated buildings, a finding which is in line with earlier studies [
13,
38,
39]. Although noise interruption and noise from colleagues achieved no significant differences in green and non-green buildings, a more detailed analysis of noise satisfaction revealed that noise from other people and general inside noise resulted in higher satisfaction in Green Star than non-green buildings. In agreement with previous studies [
40], the analysis of open comments confirmed that although participants in open-plan offices complained about noise interruptions, they favored the ease of interactions with colleagues.
Slightly higher satisfaction scores with natural lighting were reported in Green Star buildings. However, satisfaction with overall lighting showed no significant differences between green and non-green buildings. This finding contradicted with earlier studies which showed higher [
39] and lower [
10] perceived lighting satisfaction in green buildings. Surprisingly, artificial lighting and glare from artificial lighting attained a lower score in Green Star buildings, yet the effect size was very small (0.22 and 0.20). Issues related to artificial lighting in green buildings were reported in previous research [
41], where too little artificial lighting was perceived in green buildings. This might be explained by the fact that more attention is paid to the design of natural lighting in green buildings, and artificial lighting designs are overlooked by many green designers.
In response to Hypothesis 3, the study of the influence of environmental factors on satisfaction results showed that the perceived control of IEQ parameters strongly correlated with satisfaction scores in non-green buildings, while no significant correlations were detected between the two in green buildings. This might be explained by Kano’s theory of customer satisfaction. In Kano’s model of product quality attributes [
42], three product types are identified in regard to customer satisfaction: (1) must-be; (2) one-dimensional; and (3) attractive. Must-be types are those that, if not completely fulfilled, result in customer dissatisfaction [
43]. In one-dimensional qualities, customer satisfaction is proportional to the level of fulfilment [
44]. Attractive qualities are those which, if present, result in higher satisfaction, but if not present do not result in dissatisfaction [
43]. The finding in our research suggests that IEQ controls are a must-be quality in green buildings, and a one-dimensional quality in non-green buildings.
Ventilation type as an important environmental factor affects occupant satisfaction as the study showed that occupant satisfaction was inconsistent in AC and MM buildings when comparing green with non-green buildings. In AC buildings, green buildings generally showed higher satisfaction scores, particularly in parameters related to thermal comfort and IAQ. In MM buildings, satisfaction levels were comparable in green and non-green buildings except in air freshness. Ventilation and provision of fresh air was found to be the weakness in MM buildings, because air freshness scored lower in MM green buildings compared with in non-green buildings, suggesting a lack of appropriate air circulation and ventilation in MM Green Star buildings.
To investigate Hypothesis 4, which is about the influence of non-environmental factors on occupant satisfaction, the survey data was partitioned into groups based on gender, age, sitting next to a window, working history in buildings and in workstations, and office layout. In line with findings from previous research [
3], gender did not significantly affect satisfaction scores in Green Star and non-green buildings. However, earlier research [
3,
40,
45] detected slightly higher satisfaction scores by male participants, a result which is not in line with our findings. In our study, female participants showed slightly higher satisfaction scores than male participants, yet the statistical difference was insignificant, a finding which has been confirmed by a previous study [
39]. Results related to the influence of participant age on satisfaction scores reflected contradictory findings with previous studies [
46], suggesting that age might affect satisfaction. A significantly higher satisfaction score was detected in Green Star buildings, in our study, among participants aged 30 or over, yet for participants under 30, no significant differences between green and non-green buildings were noticed. Earlier research has shown that occupant expectations and perceived thermal comfort can be shifted by comfortable thermal experiences [
47]. It could be inferred that participant age or previous thermal comfort experiences affect how green buildings are perceived in workplace environments, emphasizing psychological aspects.
In line with earlier research [
48,
49], our study showed that the history of working in buildings and at workstations influences satisfaction scores by manifesting artificially higher satisfaction scores by participants who spent less than a year in their current buildings and at current workstations. This phenomenon is explained by a study by Singh and Syal [
49], which suggested that perceived satisfaction levels are higher immediately after moving into a green building (also known as the “honeymoon” effect).
Results related to the consideration of office sharing on occupant satisfaction revealed an agreement with earlier studies [
3] that the number of people using the office would affect occupant experiences and satisfaction. In our study, no significant differences were detected between green and non-green buildings in offices used only by one individual, while in offices used by more than 9 people, significantly higher satisfaction scores were reflected in Green Star buildings. However, the sample of office sharing types in the study was not consistent or evenly distributed. Future studies are recommended to create more consistent sample sizes regarding all office sharing types.
The studied Green Star buildings seemed to be more successful in meeting user needs and achieving higher satisfaction with BD&FM parameters such as overall building comfort, building design, needs, building image, cleaning, the availability of meeting rooms, storage, and occupant health and productivity. Some of the design strategies common in the five Green Star buildings could be the central atrium and open-plan offices, the use of plants and vegetation in the interior design of buildings, and the utilization of biophilic design such as the use of natural ventilation and maximizing natural lighting in buildings. However, the same strategies resulted in some weaknesses in the performance of Green Star buildings, such as noise, air freshness, air odors, and artificial lighting. Particularly, open-plan office design resulted in higher satisfaction in parameters such as building design and building image but also resulted in lower satisfaction in noise parameters. Some weaknesses of Green Star rating systems could be related to noise and air quality. Improvements in rating buildings related to noise and air quality in the Green Star Design guide could help the improvement of building performance.
This paper focused only on subjective evaluations and user perspectives on green building performance. The objective evaluation of building performance and its correlation with green building certifications was not performed here; this is recommended for future studies. Another limitation of the paper is that the operational factors of the studied buildings, such as occupancy hours, ventilation operations, and facility management, were not correlated with building performance factors. However, it should be considered that the studied buildings were consistent in terms of operational factors because all the buildings were higher education buildings under the same management systems.
7. Conclusions
This research compared Green Star buildings with their non-green counterparts by evaluating occupant satisfaction and perceived indoor environmental conditions in office workplace environments. The study showed that Green Star buildings were generally more satisfactory when compared with non-green buildings, particularly in BD&FM parameters such as overall building comfort, building design, needs, building image, cleaning, the availability of meeting rooms, storage, and occupant health and productivity. However, some weaknesses were detected, particularly in regard to IEQ parameters such as noise, air freshness, air odors, and artificial lighting.
Noise interruptions were particularly higher in open-plan offices; however, occupants in open-plan spaces favored the ease of interactions with colleagues. This suggests that innovative acoustic design and noise control in open-plan spaces are needed to enhance the acoustic performance of Green Star buildings. Low satisfaction scores with air freshness and air odors in summer could be explained by the efficiency of natural ventilation and the lack of air circulation in Green Star buildings. A study of fluid dynamics and air circulation in buildings at the design stage and green certification process seems appropriate to enhance the quality of air in Green Star buildings. Our study indicated that issues related to artificial lighting in green buildings have been generally overlooked in the past, as most green buildings put greater emphasis on natural lighting design.
Our research also identified indoor environmental controls as a must-be quality in green buildings, and as a one-dimensional quality in non-green buildings based on the definitions of Kano’s theory. This suggests that the availability of indoor environmental control positively correlates with the level of perceived satisfaction in non-green buildings, but it does not necessarily increase perceived satisfaction in green buildings. However, the absence of indoor environmental controls would result in perceived dissatisfaction in green buildings.
The study of occupant satisfaction is recommended to consider participant background information regarding gender, age, sitting next to a window, the history of work in buildings and in workstations, and office layout, because our research has indicated that these non-environmental factors affect satisfaction in buildings.