Next Article in Journal
Double Decompression of Presacral Collection by Heald Anal Stent and Foley Catheter Combination
Previous Article in Journal
Using a Curved Kirschner Wire for Fixation of Unstable Distal Radius Fractures in Children
 
 
Surgical Techniques Development is published by MDPI from Volume 11 Issue 1 (2022). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Removal of Locking Plates: New Implant, New Challenges and New Solutions

1
Department of Orthopaedics, All India Institute of Medical Sciences, New Delhi, India
2
287 Heaton Road, Newcastle Upon Tyne NE6 5QD, UK
*
Author to whom correspondence should be addressed.
Surg. Tech. Dev. 2011, 1(2), e25; https://doi.org/10.4081/std.2011.e25
Submission received: 7 July 2011 / Revised: 8 September 2011 / Accepted: 19 September 2011 / Published: 3 November 2011

Abstract

Removal of locking plates in many ways poses novel challenges compared to conventional plates. None of the techniques described for the removal of locking plates are adequate for all situations. We report our experience of 27 patients from whom a total of 33 locking plates were removed. We also describe a novel technique for the removal of locking plates which in our experience could be used in most of these patients because it is appropriate for all situations and, from a technical point of view, is easy to use. Our new technique consists of removing the problematic locking screw by cutting the plate on both sides of the screw hole and using the screw head-plate hole unit for removal. We analyzed all these patients for the location of the plate, number of locking screws, time of implant removal since the initial surgery, reason for removal of the plate, nature of the difficulties encountered during surgery, and any perioperative complications. A total of 43 (17.34%) screws were difficult to remove. Twenty screws were found to be stripped, 15 were jammed and 8 were broken. Fourteen of the 20 stripped screws and all 15 jammed screws were removed using our technique. We found this technique of locking plate removal to be very versatile and useful in most of the cases in which removal was difficult. At the same time, it also causes less damage to the bone compared to other techniques.
Keywords: locking plates; jammed screws; implant removal locking plates; jammed screws; implant removal

Share and Cite

MDPI and ACS Style

Garg, B.; Goyal, T.; Kumar, V.; Malhotra, R.; Kotwal, P.P. Removal of Locking Plates: New Implant, New Challenges and New Solutions. Surg. Tech. Dev. 2011, 1, e25. https://doi.org/10.4081/std.2011.e25

AMA Style

Garg B, Goyal T, Kumar V, Malhotra R, Kotwal PP. Removal of Locking Plates: New Implant, New Challenges and New Solutions. Surgical Techniques Development. 2011; 1(2):e25. https://doi.org/10.4081/std.2011.e25

Chicago/Turabian Style

Garg, Bhavuk, Tarun Goyal, Vijay Kumar, Rajesh Malhotra, and Prakash P. Kotwal. 2011. "Removal of Locking Plates: New Implant, New Challenges and New Solutions" Surgical Techniques Development 1, no. 2: e25. https://doi.org/10.4081/std.2011.e25

APA Style

Garg, B., Goyal, T., Kumar, V., Malhotra, R., & Kotwal, P. P. (2011). Removal of Locking Plates: New Implant, New Challenges and New Solutions. Surgical Techniques Development, 1(2), e25. https://doi.org/10.4081/std.2011.e25

Article Metrics

Back to TopTop