Next Article in Journal
Enterococcus raffinosus Infection with Atypical Hemolytic Uremic Syndrome in a Multiple Myeloma Patient after Autologous Stem Cell Transplant
Previous Article in Journal
Managing Acute Promyelocytic Leukemia in Patients Belonging to the Jehovah’s Witness Congregation
 
 
Hematology Reports is published by MDPI from Volume 14 Issue 1 (2022). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Case Report

Gluteal Artery Injuries Including Pseudoaneurysm Associated with Powered Bone Marrow Biopsies

1
Department of Hematology/Oncology, Albert Einstein College of Medicine/Montefiore Medical Center, Bronx, NY 10461, USA
2
Division of Hematology/Oncology, Department of Medicine, Jacobi Medical Center, 1400 Pelham Parkway S, Bronx, NY 10461, USA
3
Department of Radiology, Jacobi Medical Center, Bronx, NY 10461, USA
4
Division of Laboratory Medicine, Jacobi Medical Center, Bronx, NY 10461, USA
*
Author to whom correspondence should be addressed.
Hematol. Rep. 2017, 9(3), 7131; https://doi.org/10.4081/hr.2017.7131
Submission received: 12 March 2017 / Revised: 21 June 2017 / Accepted: 22 June 2017 / Published: 26 September 2017

Abstract

The bone marrow procedure (BMP) is a frequently performed procedure, with over 700,000 recorded in the U.S. annually. It is a fundamental component in the evaluation and management of both malignant and benign hematologic conditions. Adult patients are generally assured that the BMP is a safe procedure with minimal risk, albeit briefly painful. Traditionally performed using a manual Jamshidi needle, the procedure is increasingly being performed using powered bone marrow kits, which have shown consistently good results. In the current review we describe three cases of gluteal artery injuries following the powered driver procedure, one of which resulted in the formation of a pseudoaneurysm requiring radiology-guided intervention. We highlight the need for both hematologists and patients to be aware of this potentially life threatening complication as well as how to recognize it clinically and institute timely diagnostic and therapeutic measures.
Keywords: bone marrow biopsy; gluteal artery injuries; pseudoaneurysm bone marrow biopsy; gluteal artery injuries; pseudoaneurysm

Share and Cite

MDPI and ACS Style

Singh, A.P.; Pendurti, G.; Singh, S.; Shestopalov, A.; Pacello, T.; Reed, L.J. Gluteal Artery Injuries Including Pseudoaneurysm Associated with Powered Bone Marrow Biopsies. Hematol. Rep. 2017, 9, 7131. https://doi.org/10.4081/hr.2017.7131

AMA Style

Singh AP, Pendurti G, Singh S, Shestopalov A, Pacello T, Reed LJ. Gluteal Artery Injuries Including Pseudoaneurysm Associated with Powered Bone Marrow Biopsies. Hematology Reports. 2017; 9(3):7131. https://doi.org/10.4081/hr.2017.7131

Chicago/Turabian Style

Singh, Aditi P., Gopichand Pendurti, Shashi Singh, Alexander Shestopalov, Thomas Pacello, and Louis Juden Reed. 2017. "Gluteal Artery Injuries Including Pseudoaneurysm Associated with Powered Bone Marrow Biopsies" Hematology Reports 9, no. 3: 7131. https://doi.org/10.4081/hr.2017.7131

APA Style

Singh, A. P., Pendurti, G., Singh, S., Shestopalov, A., Pacello, T., & Reed, L. J. (2017). Gluteal Artery Injuries Including Pseudoaneurysm Associated with Powered Bone Marrow Biopsies. Hematology Reports, 9(3), 7131. https://doi.org/10.4081/hr.2017.7131

Article Metrics

Back to TopTop