Next Article in Journal
The Artificial Intelligence in Teledermatology: A Narrative Review on Opportunities, Perspectives, and Bottlenecks
Previous Article in Journal
Combined Effects of Multiple Per- and Polyfluoroalkyl Substances Exposure on Allostatic Load Using Bayesian Kernel Machine Regression
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Kitchen Characteristics and Practices Associated with Increased PM2.5 Concentration Levels in Zimbabwean Rural Households

by
Shamiso Muteti-Fana
1,2,*,
Jafta Nkosana
1 and
Rajen N. Naidoo
1
1
Discipline of Occupational and Environmental Health, School of Nursing and Public Health, Howard College Campus, University of KwaZulu Natal, Durban 4041, South Africa
2
Unit of Family Medicine, Global and Public Health, Department of Primary Care Sciences, Faculty of Medicine and Health Sciences, University of Zimbabwe, 3rd Floor, Parirenyatwa Hospital Grounds, Harare P.O. Box A178, Zimbabwe
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2023, 20(10), 5811; https://doi.org/10.3390/ijerph20105811
Submission received: 20 March 2023 / Revised: 8 May 2023 / Accepted: 9 May 2023 / Published: 12 May 2023

Abstract

:
Household air pollution (HAP) from biomass fuels significantly contributes to cardio-respiratory morbidity and premature mortality globally. Particulate matter (PM), one of the pollutants generated, remains the most accurate indicator of household air pollution. Determining indoor air concentration levels and factors influencing these levels at the household level is of prime importance, as it objectively guides efforts to reduce household air pollution. This paper describes household factors associated with increased PM2.5 levels in Zimbabwean rural household kitchens. Our HAP and lung health in women study enrolled 790 women in rural and urban households in Zimbabwe between March 2018 and December 2019. Here, we report data from 148 rural households using solid fuel as the primary source of fuel for cooking and heating and where indoor air samples were collected. Data on kitchen characteristics and practices were collected cross-sectionally using an indoor walk-through survey and a modified interviewer-administered questionnaire. An Air metrics miniVol Sampler was utilized to collect PM2.5 samples from the 148 kitchens over a 24 h period. To identify the kitchen features and practices that would likely influence PM2.5 concentration levels, we applied a multiple linear regression model. The measured PM2.5 ranged from 1.35 μg/m3 to 1940 μg/m3 (IQR: 52.1–472). The PM2.5 concentration levels in traditional kitchens significantly varied from the townhouse type kitchens, with the median for each kitchen being 291.7 μg/m3 (IQR: 97.2–472.2) and 1.35 μg/m3 (IQR: 1.3–97.2), respectively. The use of wood mixed with other forms of biomass was found to have a statistically significant association (p < 0.001) with increased levels of PM2.5 concentration. In addition, cooking indoors was strongly associated with higher PM2.5 concentrations (p = 0.012). Presence of smoke deposits on walls and roofs of the kitchens was significantly associated with increased PM2.5 concentration levels (p = 0.044). The study found that kitchen type, energy type, cooking place, and smoke deposits were significant predictors of increased PM2.5 concentrations in the rural households. Concentrations of PM2.5 were high as compared to WHO recommended exposure limits for PM2.5. Our findings highlight the importance of addressing kitchen characteristics and practices associated with elevated PM2.5 concentrations in settings where resources are limited and switching to cleaner fuels may not be an immediate feasible option.

1. Introduction

An estimated 2.6 billion people worldwide are at risk of ill health and premature deaths annually due to household air pollution (HAP) from domestic use of biomass fuel [1] (wood, manure, crop wastes, coal, charcoal, and cow dung) for cooking, heating, and lighting [1]. HAP was associated with 3.2 million deaths in the year 2020, with low- and middle-income countries (LMICs) being disproportionately affected [2]. Most people who use biomass as their primary source of fuel live in rural areas [3], and close to 700 million [4] of them live in Africa, predominantly in sub-Saharan Africa [5,6]. Roughly 60% of the burden of disease related to HAP is borne by women, who have increased exposure to HAP due to gender-based domestic roles [7,8].
Inefficient burning cookstoves used with biomass fuels generate a wide range of air pollutants [9], including particulate matter (PM) [10]. The levels of pollutants that household members are exposed to daily when cooking with solid fuels over an open fire or on inefficient stoves are midway between those of passive smoking and active smoking [11]. PM is responsible for some of the most harmful impacts of biomass fuel exposure on its own [12,13]. The concentration of PM of diameter ≤ 2.5 μm (PM2.5) is an important metric to estimate the risk of respiratory illness since these very small particles have the capacity to penetrate deep into the lungs when inhaled [14]. The World Health Organization (WHO) has recommended exposure threshold limits of 15 μg/m3 24 h mean for PM2.5 [15].
Indoor concentrations of pollutants are affected by several household-level factors [9], which may vary between places. Understanding of these factors in various environments crucial, as some of them can be modified to reduce indoor air pollution levels. Typically, these characteristics are context-dependent, as they are influenced by economic conditions and cultural differences. Previous research has examined the household characteristics associated with PM2.5 concentration levels in diverse environments [16,17,18]. Pollard et al. (2014), after multivariate analysis, found that thatched roof and hours spent cooking were positively associated with increased 24 h PM2.5 concentrations, whilst the presence of a chimney did not [19]. Shupler et al. (2022) carried out a multinational study in which they predicted household and personal exposure to PM2.5 and concluded that stove type, heating fuel, and presence of a chimney partially explained the variation of PM2.5 kitchen concentrations [20]. In all these various studies, context played a major role in the indoor concentration levels. Clark et al. (2010) found a link between the concentration levels and the wall type [21]. Another study in Uganda by Nakora et al. (2020) concluded that kitchens with mud and concrete walls wear out faster than those with other types of material, creating dust particles and thereby causing high PM2.5 concentrations [22]. In their study, Jafta et al. (2017) emphasized the contribution of low-quality building materials to indoor air pollution by dispersing particles into the air when disturbed [23]. From these studies, it is evident that there are contextual and cultural differences that affect HAP, which makes it difficult to generalize findings across and within countries. It is therefore important to understand the context-specific determinants of HAP in the Zimbabwean setting.
In Zimbabwe, about 67.7% of people live in rural regions [24], and mostly rely on biomass as their primary fuel source, putting a significant percentage at risk of effect of exposure to HAP. Recommendations from various studies have been to shift from dirty fuels to clean fuels [25,26,27]. However, currently, in the Zimbabwean context, this may not be feasible due to other social and public health priorities, such as malnutrition, overcrowding, poor housing conditions, and poverty. Given the probability that the use of biomass is likely to continue, it is important to understand the exposure patterns to HAP in order to design and implement context-specific interventions. Contextual differences in kitchen characteristics and cooking practices can result in a wide range of HAP concentrations, hence the need to carry out studies to evaluate exposures across various settings [10]. To accurately estimate exposure to PM2.5, it is necessary to understand a number of factors at the household level [9], including the type of fuel used, the design and location of the kitchen, and the type of stove. These will enable mechanisms to plan, implement, and evaluate preventative programs. The aim of this paper was to identify the kitchen characteristics and household practices that influence PM2.5 concentration levels in rural Zimbabwean households.

2. Materials and Methods

2.1. Setting and Study Design

In the rural district of Goromonzi in the Mashonaland East province of Zimbabwe, a community-based, cross-sectional study was conducted among women aged 18 years and older who use biomass as their primary source of fuel. We evaluated the 24 h kitchen area concentrations of PM2.5 in 148 of the 790 households recruited for the Biomass smoke and lung health in adult women in Zimbabwean families study.
The district directory of enumeration areas of Zimbabwe was used as the sampling frame to randomly select Goromonzi as the study area. The villages were selected using a multistage stratified sampling design to obtain a representative sample. At each household, we chose one woman who was 18 years old or above to aid with the walkthrough survey and respond to the questionnaire on kitchen characteristics. The woman who headed the household and did most of the cooking in the homestead was chosen when there were many women in a household who matched the inclusion criteria. All rural households (n = 466 out of the 790 households in the parent study) were using biomass as their primary source of fuel. However, for this paper, we selected only those households (n = 148) where indoor air samples had been collected (see Figure 1). Data were collected between March 2018 and December 2019. All air samples were collected during the hot/summer season.

2.2. Environmental Exposure Assessment

2.2.1. Indoor Walkthrough Assessment and Questionnaire Administration

The walkthrough assessment involved observing and recording the kitchen characteristics including ventilation (presence or absence of windows, presence, or absence of a chimney), construction material used (type of roof, type of floor, and wall material), as well as evidence of exposure to biomass smoke (residue on surfaces with categories such as heavy—dark smoke deposits with black visible soot substances with some hanging from the roof surfaces; moderate—lightly stained surfaces which evidently shows accumulation of smoke particles; or none—surfaces that have not been stained by smoke). Kitchen types were categorized into traditional (thatched kitchens) and townhouse (brick under asbestos/tile/corrugated iron kitchens), while cooking areas were categorized as separate kitchen indoors and hut/detached building and outdoors. We further categorized stoves as traditional solid fuel stoves and improved solid fuel stoves. For this study, a traditional solid fuel stove is one with an open fire and no smoke exhaust. An improved solid fuel stove is one that has an exhaust, such as a chimney or a hole in the side of the stove, which channels smoke outside of the room.

2.2.2. Fine Particulate Matter (PM2.5) Sample Collection

The primary use of solid fuel for cooking was used as an indicator of HAP exposure among rural participants. We measured the indoor (kitchen area) concentration of airborne particulate matter with an aerodynamic diameter < 2.5 µm (PM2.5) over a 24 h period continuously using a calibrated battery-operated Air Metrics Minivol model TAS 5.0 portable air sampler equipped with a 47 mm PTFE (Teflon/polytetrafluoroethylene) filter with 2.0 μm pore size [28,29]. Calibration of the sampler flowrate was performed at the start and at the end of each sampling period using a rotameter. The sampling equipment was placed in the kitchen about 1.5 m high to simulate the breathing zone and at least 1.0 m away from the wall. The air samplers were operated at a flowrate of 5 L/min as per manufacturer guidelines. At the end of the sampling period (24 h), the filters were carefully removed from the samplers, put back into filter cassettes, and transported back to the laboratory for analysis. Sampling results were reported in micrograms/cubic meter. A field blank filter was included for each batch of filters used to sample PM2.5, and we analyzed gravimetrically as part of quality control. We recorded activities done during the sampling period at the end of the sampling time to determine any other possible sources of PM2.5 during the sampling period.

2.3. Gravimetric Analysis

Weighing of filters was done using a micrometric balance (Sartorius entris Ag, Cole Parmer, Wertheim am Main, Germany) with accuracy of 0.001 mg in a laboratory with controlled humidity of 36% to 41% and temperature of 18–23 °C. Prior to the pre-sampling and post-sampling weighing sessions, all filters were equilibrated for 24 h. The filters were pre-weighed until the 0.01st milligram was stable according to the American Society for Testing and Materials (ASTM) D 1739. Filters were then stored in filter cassettes in a box and transported to the field at room temperature. The flow rate of the sampler was calibrated during deployment, and at the conclusion of the sampling time, the flow rate was once more measured using a rotameter. The change in mass at the end of the sampling period minus the blank mass change was simply divided by the volume of air sampled, and a concentration level was produced, as indicated in Equation (1). The measured PM2.5 concentration in μg/m3 was calculated according to the following equation:
C = ( M 2 M 1 B ) V s
where:
  • C = PM2.5 concentration levels in mg/m3;
  • M1 = filter mass before sampling (mg);
  • M2 = filter mass after sampling (mg);
  • B = average mass change of blanks (mg);
  • VS = volume of air sampled (m3) [30].
It was calculated using the typical sample flow rate, the sampling duration, and the surrounding pressure and temperature. As a result, each household had its air tested for about 7200 L (7.2 m3) throughout the course of a 24 h period. The ultimate mass concentration was estimated in mg/m3. The limit of detection (LOD) of the weighing procedure was determined from three times the standard deviation of the weight changes of field blank filters [31]. We used a total of 11 blank filters in computing the limit of detection at 2.71 μg/m3 [32]. We then substituted left-censored data with LOD/2, which is 1.35 μg/m3.

2.4. Statistical Methods

The statistical data analysis was conducted in R statistical computing software version 3.6.3. The descriptive statistics were presented in the form of counts and percentages for categorical variables whereas the numeric variables displayed as minimum, maximum, and quartiles. The PM2.5 distribution was highly skewed such that either the Wilcoxon [33] or Kruskal–Wallis test [34] was used to assess the difference in the PM2.5 levels between the categories of the variables. Multiple linear regression was fitted on the log-transformed PM2.5. Stepwise regression was used to determine the predictors of the PM2.5 levels. All the tests were conducted at 5% level of significance.

3. Results

Samples from 148 kitchens that used biomass as their primary source of fuel were analyzed for this work. The median PM2.5 concentrations in the 148 houses was 278 μg/m3 (IQR: 52.1, 472).

3.1. Kitchen Characteristics and PM2.5

Table 1 below shows that most participants (92.6%) had traditional kitchens as opposed to townhouse kitchens. There was a statistically significant difference in PM2.5 concentration between traditional kitchens and townhouse-type kitchens, with median concentration levels being 291.7 μg/m3 (IQR = 97.2–472.2 μg/m3) and 1.35 μg/m3 (IQR = 1.3–97.2 μg/m3), respectively (p = 0.008). In addition, it was observed that kitchens that had mud walls had increased PM2.5 concentration levels compared to kitchens that had walls made of tile, asbestos, or corrugated iron (p = 0.134). However, this discrepancy did not reach statistical significance. A limited number of kitchens (22.3%) included in the study were found to have chimneys. These kitchens exhibited elevated levels of PM2.5 concentration in comparison to those without chimneys (p = 0.102). However, the observed difference was not statistically significant. The study findings indicate that a minority of the participants (38.4%) reported preparing meals more than three times a day, and their kitchens had lower PM2.5 concentration levels compared to those who prepared less than three meals per day, but the observed difference was not statistically significant (p = 0.100).
Construction year of the kitchen (pre or post 1985 (p = 0.286), roof type (p = 0.618), floor type (p = 0.944), having ever stayed with a smoker (p = 0.656), biomass use duration (p = 0.898), time spent cooking per day (p = 0.902), window opening frequency (p = 0.944), and monthly income (p = 0.966) had no statistically significant associations with the PM2.5 concentration levels in the sampled households (Table 1).

3.2. Sources of PM2.5 Levels

Evidence of tobacco smoking was reported by few participants (4.7%); however, it was significantly associated with an increase in PM2.5 concentration levels, with a median concentration level of 597.2 μg/m3 (IQR of 326.4–1319.4) compared to 263.9 μg/m3 (IQR (1.3–97.2) in the kitchens of those who did not report it. The most used type of stove in this study was the traditional solid fuel stove (87.8%), and its use was significantly associated with increased PM2.5 concentration levels as compared to the improved solid fuel stove (p = 0.072). Most of the participants in this study (87.8%) used wood in combination with other biomass fuels to enhance the fire during cooking times. Comparing use of wood only and use of wood mixed with other types of biomass fuels such as cow dung and crop residues, using wood only was associated with decreased PM2.5 concentration levels (p = 0.001). Most participants (70.3%) reported cooking inside the hut, while the rest of the respondents reported that they cooked outdoors or in other separate rooms. Cooking indoors was significantly associated with increased PM2.5 concentration levels, with the median being 333.3 μg/m3 compared to 118.1 μg/m3 among those who did not cook indoors. More than half (53.4%) of the kitchens that were sampled had heavy smoke deposits on the walls and roof. These kitchens were significantly associated with increased PM2.5 levels (p = 0.018) as compared to the kitchen that had none to modest smoke deposits.
Scented candles (p = 0.786), incense use (p = 0.263), and use of a space heater (p = 0.632) had no significant association with PM2.5 levels in the sampled households (Table 2).

3.3. Multiple Linear Regression Model with PM Concentrations as Dependent Variables

Table 3 presents the outcomes of a multiple regression analysis that was conducted to model the relationship between PM2.5 and the variables related to kitchen characteristics and exposure. The variables included in the model were those with a p-value below 0.25 in the univariate analysis. The statistical analysis revealed a significant association (p = 0.033) between the traditional kitchen type and elevated levels of PM2.5 in comparison to the townhouse kitchen type. The study also found a significant correlation between increased levels of PM2.5 concentration and the energy type, cooking in a hut, and heavy smoke deposits. In addition, the use of wood in combination with other forms of biomass such as cow dung and crop residue were found to be correlated with heightened levels of PM2.5.
Contrary to the univariate analysis findings, use of traditional solid fuel stoves was associated with decreased PM2.5 concentration levels. Preparing meals more than three times was found to have a statistically significant correlation with low PM2.5 concentration levels (p = 0.054). Compared to households that had none to modest smoke deposits on the kitchen roofs and windows, heavy smoke deposits in the kitchen were associated with increased PM2.5 concentration levels, and the difference was statistically significant (p = 0.043). There was a positive correlation between households that had evidence of tobacco smoking and elevated levels of PM2.5 (p = 0.056), but it was not statistically significant. Having a chimney (p = 0.622) and cement/wood/corrugated iron wall type (p = 0.251) were not associated with the PM2.5 concentration levels.

3.4. Predictive Multiple Linear Regression Modelling with Strongest Predictors

Table 4 displays the primary factors influencing PM2.5 concentration levels as determined by the stepwise multiple linear regression model. The statistical model exhibited a superior fit, as evidenced by a significant overall goodness-of-fit (p-value < 0.001) and an adjusted R2 value of 0.355. The findings of the study indicate a statistically significant association between traditional kitchens and elevated levels of PM2.5 as compared to townhouse kitchens (p = 0.033). Statistically significant correlations were also noted between elevated levels of PM2.5 concentration levels and energy type (p = 0.001), cooking in a hut (p = 0.001), and heavy smoke deposits (p = 0.044). Furthermore, the use of wood in conjunction with other types of biomass such as cow dung and crop residue was associated with increased PM2.5 concentration (p = 0.001) compared to the use of wood only.
Whilst there was a positive correlation between households with evidence of tobacco smoking and elevated levels of PM2.5 (p = 0.056), the relationship was not statistically significant. Even though use of traditional solid fuel stove was initially found to be associated with increased PM2.5, it became significantly associated with reduced PM2.5 concentration levels after the multivariate analysis (p = 0.006). Comparing the number of meals prepared per day, those who prepared more than three meals per day had decreased PM2.5 concentration levels compared to those who prepared less than three meals per day; however, the difference was not statistically significant (p = 0.056).
E log PM 2.5 = β k 1 I Kitehen   type   =   Traditional +   β k 2 I Evidence   of   tobacco   smoke =   Yes +   β k 4 I Stove _ type =   Traditional   solid   fuel   stove / Open   fire / Other +   β s 1 I Energy _ type =   Wood / Other +   β s 2 I Cooking   place =   Indoors +   β s 3 I Food _ preparation _ frequency   = 3 + +   β s 5 I Smoke   deposits   =   Heavy

4. Discussion

Our study showed that PM2.5 concentration levels in Zimbabwean rural households are high, with most of them having levels above the WHO-recommended exposure limits for PM2.5. This is congruent with previous studies done in Zimbabwe, where levels of >40 μg/m3 have been reported [36,37,38], and elsewhere, including South Africa [10,16,17,18,23,39]. The factors that proved to be the best predictors of PM2.5 concentration after stepwise regression model were kitchen type, energy type, cooking place, and smoke deposits.
Consistent with previous studies, traditional type of kitchens had significantly higher levels of PM2.5 [16]. These kitchens are usually made of poles, mud, and grass and have thatched roofs, which have a higher likelihood of accumulating indoor contaminants [17]. It is also important to note that most respondents with traditional-style kitchens were in the low socio-economic group earning below USD 150 monthly even though income was not statistically significantly associated with PM2.5 concentration levels in the univariate analysis. The energy ladder depicts socioeconomic status as an important determinant of fuel preferences at the household level [40,41,42].
Additionally, income influences other factors such as kitchen characteristics, stove type, and food preparation frequency. Fandiño-Del-Rio et al. (2020) also reported that higher kitchen PM concentrations were likewise related to lower levels of wealth in Peru [17]. The assumption is that low-income households are more likely to utilize biomass and other inexpensive, dirty fuels since they are less likely to be able to afford alternative, cleaner fuels. Additionally, with fewer resources, it is possible that the kitchen’s design and construction materials are of poor quality, which encourages the buildup of pollutants indoors [23]. In a study examining the patterns and predictors of indoor air pollution in India, Baumgartner et al. (2021) found kitchen structure as one of the significant predictors of personal PM2.5 exposure among people who used biomass as the primary source of fuel [43].
A significant percentage of the study participants (88.4%) indicated that they used traditional solid fuel stoves. Contrary to what other studies have found, these households exhibited lower PM2.5 concentration levels compared to those households that use the improved solid fuel stoves. This finding is opposed to what Clark et al. (2016) found, where improved cooking stoves were associated with reduced indoor air concentration levels [21]. However, the study also highlighted the limitation of using the type of stove to assign exposure, as there is a great deal of variation in different stove types and levels of PM2.5 concentrations associated with each type [21]. Yip et al. in Kenya also found that the mean 48 h concentrations of PM2.5 were lower in improved solid fuel stoves than in traditional solid fuel stoves [44].
When compared to the use of wood alone, the use of wood combined with other types of biomass such as cow dung and crop residues resulted in a significant increase in PM2.5 concentration levels. This could be because the other types of biomass are regarded as the least-efficient burning types of biomass fuels on the energy ladder [41]. Research has highlighted that most solid fuel users do not utilize a single type of fuel but rather a mixture of multiple types depending on availability [25]. It is therefore appropriate to urge rural communities such as the one that was included in our study to use wood as their only fuel source in situations where there are no other cleaner alternatives.
It is well known that using biomass fuels indoors for cooking causes HAP, especially when the area is not well ventilated. Throughout this study, we detected higher PM2.5 concentrations in kitchens where cooking occurred inside. When cooking is done inside, the released smoke remains suspended in the atmosphere for prolonged periods of time mainly due to poor ventilation, exposing residents to home air pollution. The element of cooking inside is connected to kitchen type since it determines whether or not indoor air pollutants will accumulate; it all relies on the type of the kitchen.
In this investigation, there were smoke deposits in around 53.4% of the kitchens, and this was statistically significant. It is widely known that higher PM2.5 concentration levels are linked to the presence of smoke deposits in the kitchen or cooking area. Previous studies have highlighted how certain contaminants are deposited on kitchen walls before leaving the kitchens [45]. This phenomenon, when it occurs more often, continues to leave dark marks on the roof and walls, and this is a common scenario in the majority of rural homes: some particulate matter is retained on the kitchen walls or roof rather than escaping outside [45,46].
Approximately 38.4% of the study participants reported that they prepared more than three meals per day, and their kitchens recorded lower PM2.5 concentration levels compared to those who prepared less than three meals per day. It may be difficult to use this variable as a proxy for indoor PM2.5 concentration levels unless there are more details about the types of meals that were prepared and the duration it took to prepare each meal. There are many contextual differences in the way that meals are prepared in one household or another. Therefore, it is difficult to interpret the association between the measured PM2.5 concentration levels and the number of prepared meals per day. A person may report making one or two meals per day but may spend more time doing so than someone who prepares more than three meals per day.

Strengths and Limitations of the Study

While previous studies have demonstrated that monitoring both indoor and outdoor air sampling is necessary for characterizing HAP, such monitoring was not possible in this investigation due limited resources and logistical constraints. However, some studies have argued that the background ambient PM2.5 concentrations in rural areas, as in the case of our context, are unlikely to significantly contribute to the exposures experienced by individuals who cook with biomass [19], while the case maybe different in urban areas, where there is a great deal of traffic and other industrial activities that generate particulate matter that infiltrates indoors. Another study by Shupler et al. (2022) indicated that ambient air pollution influences HAP exposure though sometimes it may not be feasible to quantify the effect of ambient air on HAP [20]. In a different context, in India, Anand et al. (2021) concluded that ambient PM2.5 was the most significant predictor for indoor concentration levels [47] such that with adequate conditions, polluted air can infiltrate indoors. The infiltration of contaminants from ambient air into interior spaces has been documented in most industrialized countries when the ratio of indoor to outside pollution is less than one [48]. The majority of developing countries, on the other hand, have discovered that interior air pollution levels were much higher than outdoor air pollution levels, especially in rural areas where the indoor/outdoor ratio is greater than one, and pollutant exfiltration from inside to outside is projected [45].
However, there are important strengths in our study; for instance, we used the gravimetric sampling technique, which is considered the gold standard in air sampling because it is precise and accurate. Furthermore, we were able to collect detailed data from the households and carried out indoor walk-through assessments to aid with gathering adequate information about the households.

5. Conclusions and Recommendations

When compared to the WHO-recommended exposure limits for PM2.5, the PM2.5 concentrations in this study were excessive. Significant predictors of PM2.5 concentrations included kitchen type, energy type, cooking place, and smoke deposits. Our findings underscore the need to educate the public on the impact of HAP exposure and the best practices for minimizing exposure in the home as a means of lowering pollution levels. A coordinated effort including all stakeholders might produce encouraging outcomes. An acceptable strategy would include a nationwide public awareness campaign on the link between indoor air pollution and poor health and practical action. It is important to look at how the traditional kitchens are designed and aim to improve kitchen design to reduce indoor accumulation of smoke. There is a need to instill behavior change among the at-risk population by adopting low-cost methods to prevent HAP. Policymakers can also play a role by enacting measures to ensure that kitchens are built to a certain standard using materials that may not promote accumulation of pollutants indoors. To reduce the indoor PM2.5 levels in rural kitchens in Zimbabwe, alterations to the kitchen’s physical characteristics to ensure that it allows air exchange during cooking times may be of benefit.

Author Contributions

S.M.-F., study design conceptualization, methodology, initial analysis, and writing—original draft preparation; R.N.N., conceptualization, supervision, and review of subsequent drafts; J.N., training on air sampling, supervision, initial analysis, and first draft and review of subsequent versions. All authors have read and agreed to the published version of the manuscript.

Funding

Research reported in this publication was supported by the College of Health Sciences, UKZN, and also the Fogarty International Center (Office Of The Director, National Institutes Of Health (OD); National Institute Of Nursing Research (NINR), National Institute Of Mental Health (NIMH); National Institute Of Dental and Craniofacial Research (NIDCR); National Institute Of Neurological Disorders And Stroke (NINDS); National Heart, Lung, and Blood Institute (NHLBI); and Fogarty International Center (FIC) of the National Institutes of Health under Award Number D43 TW010137). The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Institutional Review Board of Medical Research Council of Zimbabwe (Ref Number: MRCZ/A/2172) and the Biomedical Research Ethics Committee of the University of KwaZulu-Natal (Ref Number: BE 060/19).

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author.

Acknowledgments

We would like to thank the women who participated in the study. We also like to thank the biostatistician for the assistance with the analysis process for this paper.

Conflicts of Interest

The authors declare no conflict of interest. The funders had no role in the design of the study; in the collection, analyses, or interpretation of data; in the writing of the manuscript; or in the decision to publish the results.

References

  1. World Health Organisation. WHO Publishes New Global Data on the Use of Clean and Polluting Fuels for Cooking by Fuel Type. Available online: https://www.who.int/news/item/20-01-2022-who-publishes-new-global-data-on-the-use-of-clean-and-polluting-fuels-for-cooking-by-fuel-type (accessed on 20 February 2022).
  2. Lee, K.K.; Bing, R.; Kiang, J.; Bashir, S.; Spath, N.; Stelzle, D.; Mortimer, K.; Bularga, A.; Doudesis, D.; Joshi, S.S.; et al. Adverse Health Effects Associated with Household Air Pollution: A Systematic Review, Meta-Analysis, and Burden Estimation Study. Lancet Glob. Health 2020, 8, e1427–e1434. [Google Scholar] [CrossRef] [PubMed]
  3. Arku, R.E.; Birch, A.; Shupler, M.; Yusuf, S.; Hystad, P.; Brauer, M. Characterizing Exposure to Household Air Pollution within the Prospective Urban Rural Epidemiology (PURE) Study. Environ. Int. 2018, 114, 307–317. [Google Scholar] [CrossRef] [PubMed]
  4. Lambe, F.; Jürisoo, M.; Wanjiru, H.; Senyagwa, J. Bringing Clean, Safe, Affordable Cooking Energy to Households across Africa: An Agenda for Action; New Climate Economy: Washington, DC, USA, 2015; 32p. [Google Scholar]
  5. Aemro, Y.B.; Moura, P.; de Almeida, A.T. Inefficient Cooking Systems a Challenge for Sustainable Development: A Case of Rural Areas of Sub-Saharan Africa. Environ. Dev. Sustain. 2021, 23, 14697–14721. [Google Scholar] [CrossRef]
  6. Karimu, A.; Dramani, J.B. Energy Consumption Patterns in Africa: The Role of Biomass Fuels for Cooking and Fuel Use in the Transportation Sector. In Sustainable Consumption and Production, Volume I: Challenges and Development; Bali Swain, R., Sweet, S., Eds.; Springer International Publishing: Cham, Switzerland, 2021; pp. 315–341. ISBN 978-3-030-56371-4. [Google Scholar]
  7. Gordon, S.B.; Bruce, N.G.; Grigg, J.; Hibberd, P.L.; Kurmi, O.P.; Lam, K.H.; Mortimer, K.; Asante, K.P.; Balakrishnan, K.; Balmes, J.; et al. Respiratory Risks from Household Air Pollution in Low and Middle Income Countries. Lancet Respir. Med. 2014, 2, 823–860. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  8. Okello, G.; Devereux, G.; Semple, S. Women and Girls in Resource Poor Countries Experience Much Greater Exposure to Household Air Pollutants than Men: Results from Uganda and Ethiopia. Environ. Int. 2018, 119, 429–437. [Google Scholar] [CrossRef]
  9. Balakrishnan, K.; Ghosh, S.; Ganguli, B.; Sambandam, S.; Bruce, N.; Barnes, D.F.; Smith, K.R. State and National Household Concentrations of PM2.5 from Solid Cookfuel Use: Results from Measurements and Modeling in India for Estimation of the Global Burden of Disease. Environ. Health 2013, 12, 77. [Google Scholar] [CrossRef] [Green Version]
  10. Chen, C.; Zeger, S.; Breysse, P.; Katz, J.; Checkley, W.; Curriero, F.C.; Tielsch, J.M. Estimating Indoor PM2.5 and CO Concentrations in Households in Southern Nepal: The Nepal Cookstove Intervention Trials. PLoS ONE 2016, 11, e0157984. [Google Scholar]
  11. Bonjour, S.; Adair-Rohani, H.; Wolf, J.; Bruce, N.G.; Mehta, S.; Prüss-Ustün, A.; Lahiff, M.; Rehfuess, E.A.; Mishra, V.; Smith, K.R. Solid Fuel Use for Household Cooking: Country and Regional Estimates for 1980–2010. Environ. Health Perspect. 2013, 121, 784–790. [Google Scholar] [CrossRef] [Green Version]
  12. Ezzati, M.; Kammen, D.M. Quantifying the Effects of Exposure to Indoor Air Pollution from Biomass Combustion on Acute Respiratory Infections in Developing Countries. Environ. Health Perspect. 2001, 109, 8. [Google Scholar] [CrossRef] [PubMed]
  13. Ezzati, M.; Kammen, D.M. The Health Impacts of Exposure to Indoor Air Pollution from Solid Fuels in Developing Countries: Knowledge, Gaps, and Data Needs. Environ. Health Perspect. 2002, 110, 1057–1068. [Google Scholar] [CrossRef] [Green Version]
  14. Shupler, M.; Godwin, W.; Frostad, J.; Gustafson, P.; Arku, R.E.; Brauer, M. Global Estimation of Exposure to Fine Particulate Matter (PM2.5) from Household Air Pollution. Environ. Int. 2018, 120, 354–363. [Google Scholar] [CrossRef]
  15. World Health Organisation. WHO Global Air Quality Guidelines; World Health Organisation: Geneva, Switzerland, 2021. [Google Scholar]
  16. Colbeck, I.; Nasir, Z.A.; Ali, Z. Characteristics of Indoor/Outdoor Particulate Pollution in Urban and Rural Residential Environment of Pakistan. Indoor Air 2010, 20, 40–51. [Google Scholar] [CrossRef] [PubMed]
  17. Fandiño-Del-Rio, M.; Kephart, J.L.; Williams, K.N.; Moulton, L.H.; Steenland, K.; Checkley, W.; Koehler, K. Household Air Pollution Exposure and Associations with Household Characteristics among Biomass Cookstove Users in Puno, Peru. Environ. Res. 2020, 191, 110028. [Google Scholar] [CrossRef] [PubMed]
  18. Shezi, B.; Jafta, N.; Sartorius, B.; Naidoo, R.N. Developing a Predictive Model for Fine Particulate Matter Concentrations in Low Socio-Economic Households in Durban, South Africa. Indoor Air 2018, 28, 228–237. [Google Scholar] [CrossRef] [PubMed]
  19. Pollard, S.L.; Williams, D.L.; Breysse, P.N.; Baron, P.A.; Grajeda, L.M.; Gilman, R.H.; Miranda, J.J.; Checkley, W. A Cross-Sectional Study of Determinants of Indoor Environmental Exposures in Households with and without Chronic Exposure to Biomass Fuel Smoke. Environ. Health 2014, 13, 21. [Google Scholar] [CrossRef] [Green Version]
  20. Shupler, M.; Hystad, P.; Birch, A.; Chu, Y.L.; Jeronimo, M.; Miller-Lionberg, D.; Gustafson, P.; Rangarajan, S.; Mustaha, M.; Heenan, L.; et al. Multinational Prediction of Household and Personal Exposure to Fine Particulate Matter (PM2.5) in the PURE Cohort Study. Environ. Int. 2022, 159, 107021. [Google Scholar] [CrossRef]
  21. Clark, M.L.; Reynolds, S.J.; Burch, J.B.; Conway, S.; Bachand, A.M.; Peel, J.L. Indoor Air Pollution, Cookstove Quality, and Housing Characteristics in Two Honduran Communities. Environ. Res. 2010, 110, 12–18. [Google Scholar] [CrossRef]
  22. Nakora, N.; Byamugisha, D.; Birungi, G. Indoor Air Quality in Rural Southwestern Uganda: Particulate Matter, Heavy Metals and Carbon Monoxide in Kitchens Using Charcoal Fuel in Mbarara Municipality. SN Appl. Sci. 2020, 2, 2037. [Google Scholar] [CrossRef]
  23. Jafta, N.; Barregard, L.; Jeena, P.M.; Naidoo, R.N. Indoor Air Quality of Low and Middle Income Urban Households in Durban, South Africa. Environ. Res. 2017, 156, 47–56. [Google Scholar] [CrossRef]
  24. Zimbabwe Rural Population, Percent—Data, Chart. Available online: https://www.theglobaleconomy.com/Zimbabwe/rural_population_percent/ (accessed on 19 January 2023).
  25. Karakara, A.A.; Osabuohien, E.S. Clean versus Dirty Energy: Empirical Evidence from Fuel Adoption and Usage by Households in Ghana. Afr. J. Sci. Technol. Innov. Dev. 2021, 13, 785–795. [Google Scholar] [CrossRef]
  26. Shen, G. Quantification of Emission Reduction Potentials of Primary Air Pollutants from Residential Solid Fuel Combustion by Adopting Cleaner Fuels in China. J. Environ. Sci. 2015, 37, 1–7. [Google Scholar] [CrossRef] [PubMed]
  27. Acharya, B.; Marhold, K. Determinants of Household Energy Use and Fuel Switching Behavior in Nepal. Energy 2019, 169, 1132–1138. [Google Scholar] [CrossRef]
  28. MiniVol TAS—Portable Air Sampler by AirMetrics. Available online: https://www.environmental-expert.com/products/minivol-tas-portable-air-sampler-42632 (accessed on 9 November 2021).
  29. Lane, D.D.; Baldauf, R.W.; Marotz, G.A. Performance Characterization of the Portable MiniVOL Particulate Matter Sampler. WIT Trans. Ecol. Environ. 2001, 47, 12. [Google Scholar]
  30. Methods for the Determination of Hazardous Substances. Available online: Mdhs_14_general_methods_for_sampling_and_gravimetric_analysis_of_respirable_and_inhalable_dust.Pdf (accessed on 20 February 2022).
  31. Health and Safety Executive. General Methods for Sampling and Gravimetric Analysis of Respirable, Thoracic and Inhalable Aerosols. Available online: https://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf (accessed on 20 February 2022).
  32. Vaughan, N.P.; Milligan, B.D.; Ogden, T.L. Filter weighing reproducibility and the gravimetric detection limit. Ann. Occup. Hyg. 1989, 33, 331–337. [Google Scholar] [CrossRef]
  33. Wilcoxon, F. Individual Comparisons by Ranking Methods. Biom. Bull. 1945, 1, 80–83. [Google Scholar] [CrossRef]
  34. Kruskal, W.H.; Wallis, W.A. Use of Ranks in One-Criterion Variance Analysis. J. Am. Stat. Assoc. 1952, 47, 583–621. [Google Scholar] [CrossRef]
  35. Wilcoxon Test in R: How to Compare 2 Groups under the Non-Normality Assumption? Available online: https://statsandr.com/blog/wilcoxon-test-in-r-how-to-compare-2-groups-under-the-non-normality-assumption/ (accessed on 21 April 2023).
  36. Collings, D.; Sithole, S.; Martin, K. Indoor Woodsmoke Pollution Causing Lower Respiratory Disease in Children. Trop. Dr. 1990, 20, 151–155. [Google Scholar] [CrossRef]
  37. Rumchev, K.; Spickett, J.T.; Brown, H.L.; Mkhweli, B. Indoor Air Pollution from Biomass Combustion and Respiratory Symptoms of Women and Children in a Zimbabwean Village. Indoor Air 2007, 17, 468–474. [Google Scholar] [CrossRef]
  38. Shupler, M.; Hystad, P.; Birch, A.; Miller-Lionberg, D.; Jeronimo, M.; Arku, R.E.; Chu, Y.L.; Mushtaha, M.; Heenan, L.; Rangarajan, S.; et al. Household and Personal Air Pollution Exposure Measurements from 120 Communities in Eight Countries: Results from the PURE-AIR Study. Lancet Planet. Health 2020, 4, e451–e462. [Google Scholar] [CrossRef]
  39. Fullerton, D.G.; Suseno, A.; Semple, S.; Kalambo, F.; Malamba, R.; White, S.; Jack, S.; Calverley, P.M.; Gordon, S.B. Wood Smoke Exposure, Poverty and Impaired Lung Function in Malawian Adults. Int. J. Tuberc. Lung Dis. 2011, 15, 391–398. [Google Scholar]
  40. Adamu, M.B.; Adamu, H.; Ade, S.M.; Akeh, G.I. Household Energy Consumption in Nigeria: A Review on the Applicability of the Energy Ladder Model. J. Appl. Sci. Environ. Manag. 2020, 24, 237–244. [Google Scholar] [CrossRef]
  41. Meried, E.W. Rural Household Preferences in Transition from Traditional to Renewable Energy Sources: The Applicability of the Energy Ladder Hypothesis in North Gondar Zone. Heliyon 2021, 7, e08418. [Google Scholar] [CrossRef]
  42. Kurmi, O.P.; Lam, K.B.H.; Ayres, J.G. Indoor Air Pollution and the Lung in Low- and Medium-Income Countries. Eur. Respir. J. 2012, 40, 239–254. [Google Scholar] [CrossRef]
  43. Baumgartner, J.; Schauer, J.J.; Ezzati, M.; Lu, L.; Cheng, C.; Patz, J.; Bautista, L.E. Patterns and Predictors of Personal Exposure to Indoor Air Pollution from Biomass Combustion among Women and Children in Rural China. Indoor Air 2011, 21, 479–488. [Google Scholar] [CrossRef] [PubMed]
  44. Yip, F.; Christensen, B.; Sircar, K.; Naeher, L.; Bruce, N.; Pennise, D.; Lozier, M.; Pilishvili, T.; Loo Farrar, J.; Stanistreet, D.; et al. Assessment of Traditional and Improved Stove Use on Household Air Pollution and Personal Exposures in Rural Western Kenya. Environ. Int. 2017, 99, 185–191. [Google Scholar] [CrossRef] [PubMed]
  45. Adhikari, S.; Mahapatra, P.S.; Pokheral, C.P.; Puppala, S.P. Cookstove Smoke Impact on Ambient Air Quality and Probable Consequences for Human Health in Rural Locations of Southern Nepal. Int. J. Environ. Res. Public Health 2020, 17, 550. [Google Scholar] [CrossRef] [Green Version]
  46. Soneja, S.I.; Tielsch, J.M.; Curriero, F.C.; Zaitchik, B.; Khatry, S.K.; Yan, B.; Chillrud, S.N.; Breysse, P.N. Determining Particulate Matter and Black Carbon Exfiltration Estimates for Traditional Cookstove Use in Rural Nepalese Village Households. Environ. Sci. Technol. 2015, 49, 5555–5562. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  47. Anand, A.; Phuleria, H.C. Modeling Indoor Exposure to PM2.5 and Black Carbon in Densely Populated Urban Slums. Build. Environ. 2021, 200, 107940. [Google Scholar] [CrossRef]
  48. He, C.; Morawska, L.; Hitchins, J.; Gilbert, D. Contribution from Indoor Sources to Particle Number and Mass Concentrations in Residential Houses. Atmos. Environ. 2004, 38, 3405–3415. [Google Scholar] [CrossRef]
Figure 1. Flow diagram of the recruitment process.
Figure 1. Flow diagram of the recruitment process.
Ijerph 20 05811 g001
Table 1. PM2.5 and kitchen characteristics and lifestyle for rural participants in 148 households.
Table 1. PM2.5 and kitchen characteristics and lifestyle for rural participants in 148 households.
Characteristicn
(%)
PM2.5 Concentration Median (IQR)p-Value
Kitchen type
Townhouse11 (7.4%)1.3 (1.3, 97.2)0.008 *
Traditional137 (92.6%)291.7 (97.2, 472.2)
Construction year ϕ
Pre 198526 (20.5%)305.6 (138.9, 649.3)0.286
Post 1985101 (79.5%)263.9 (27.8, 430.6)
Roof type
Thatch102 (68.9%)291.7 (114.6, 430.6)0.618
Tile/Asbestos/Corrugated iron46 (31.1%)215.3 (27.8, 677.1)
Wall type
Mud71 (48.0%)291.7 (152.8, 500)0.134
Cement/Wood/Corrugated iron77 (52.0%)250 (27.8, 430.6)
Floor type
Cement136 (91.9%)277.8 (55.6, 472.2)0.944
Wood floor/Tile/Other12 (8.1%)298.6 (1.3, 506.9)
Chimney
No115 (77.7%)291.7 (118.1, 468.7)0.102
Yes33 (22.3%)111.1 (27.8, 513.9)
Ever stayed with a smoker
No70 (47.3%)256.9 (55.6, 468.7)0.656
Yes78 (52.7%)291.7 (55.6, 501.7)
Biomass fuel use duration ϕ
≤30 years66 (45.2%)284.7 (27.8, 451.4)0.898
>30 years80 (54.8%)263.9 (97.2, 531.3)
Time spent cooking/day ϕ
<2 h32 (22.2%)263.9 (131.9, 395.8)0.902
≥2 h112 (77.8%)277.8 (27.8, 479.2)
Food preparation frequency/day ϕ
<390 (61.6%)277.8 (114.6, 513.9)0.100
3+56 (38.4%)270.8 (1.3, 430.6)
Window opening frequency
Most of the time119 (80.4%)277.8 (41.7, 486.1)0.944
Never/occasionally29 (19.6%)263.9 (111.1, 388.9)
Monthly income
<$150129 (87.2%)278(52.1–472)0.966
$150+19 (12.8%)148(1.35–1940)
ϕ Variables with less than 148 responses. * p-value considered significant at <0.05.
Table 2. Household characteristics and indoor PM2.5 concentration in 148 households.
Table 2. Household characteristics and indoor PM2.5 concentration in 148 households.
Characteristic n
(%)
PM2.5 Concentration Median (IQR)p-Value &
Evidence of tobacco smoking
No141 (95.3%)263.9 (41.7, 458.3)0.045 *
Yes7 (4.7%)597.2 (326.4, 1319.4)
Scented candles use ϕ
No135 (92.5%)277.8 (48.6, 472.2)0.786
Yes11 (7.5%)291.7 (132.6, 458.3)
Incense use ϕ
No141 (96.6%)277.8 (55.6, 500)0.263
Yes5 (3.4%)263.9 (1.3, 291.7)
Stove type
Traditional solid fuel stove 130 (87.8%)277.8 (100.7, 472.2)0.072
Improved solid fuel stove18 (12.2%)1.3 (1.3, 444.4)
Energy type ϕ
Wood only17 (11.6%)1.3 (1.3, 41.7)<0.001 *
Wood and other130 (88.4%)291.7 (114.6, 500)
Cooking place
Outdoors44 (29.7%)118.1 (1.3, 277.8)<0.001 *
Indoors104 (70.3%)333.3 (159.7, 531.3)
Ventilation method
Doors/Windows146 (98.6%)277.8 (45.1, 472.2)#
Other2 (1.4%)284.7 (267.4, 302.1)
Visible smoke deposits
None to modest69 (46.6%)250 (27.8, 388.9)0.018 *
Heavy79 (53.4%)347.2 (125, 534.7)
Space heater
No143 (96.6%)277.8 (48.6, 468.7)0.632
Yes5 (3.4%)277.8 (208.3, 722.2)
# The data were not enough for statistical inference; ϕ variables with missing data are therefore less than 148 responses; & Wilcoxon test [35]; * p-value considered significant at <0.05.
Table 3. Multiple linear regression model with PM concentrations as dependent variables.
Table 3. Multiple linear regression model with PM concentrations as dependent variables.
Explanatoryβ95% CIp-Value
Kitchen_typeTraditional1.510.12 to 2.900.033 *
Wall_typeCement/Wood/Corrugated iron−0.38−1.03 to 0.270.251
ChimneyYes0.21−0.62 to 1.040.622
Evidence_of_tobacco_smokingYes1.46−0.04 to 2.960.056
Stove_typeTraditional solid fuel stove/Open fire/Other−1.34−2.31 to −0.370.007 *
Energy_typeWood/Other2.051.00 to 3.090.001*
Cooking_placeIndoors1.260.54 to 1.980.001 *
Food_preparation_frequency3+−0.671.36 to 0.010.054 *
Smoke_depositsHeavy0.660.02 to 1.30 0.043 *
* p-value considered significant at <0.05.
Table 4. Multiple linear regression model with the strongest predictors.
Table 4. Multiple linear regression model with the strongest predictors.
Explanatoryβ95% CIp-Value
Kitchen_typeTraditional1.550.29 to 2.820.016 *
Evidence_of_tobacco_smokingYes1.46−0.04 to 2.950.056
Stove_typeTraditional solid fuel stove/Open fire/Other−1.36−2.33 to −0.390.006 *
Energy_typeWood/Other2.101.06 to 3.130.001 *
Cooking_placeIndoors1.210.50 to 1.930.001 *
Food_preparation_frequency3+−0.67−1.35 to 0.020.056
Smoke_depositsHeavy0.650.02 to 1.280.044 *
* p-value considered significant at <0.05. Note: Predictor variables were used in Equation (2) as follows.
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Muteti-Fana, S.; Nkosana, J.; Naidoo, R.N. Kitchen Characteristics and Practices Associated with Increased PM2.5 Concentration Levels in Zimbabwean Rural Households. Int. J. Environ. Res. Public Health 2023, 20, 5811. https://doi.org/10.3390/ijerph20105811

AMA Style

Muteti-Fana S, Nkosana J, Naidoo RN. Kitchen Characteristics and Practices Associated with Increased PM2.5 Concentration Levels in Zimbabwean Rural Households. International Journal of Environmental Research and Public Health. 2023; 20(10):5811. https://doi.org/10.3390/ijerph20105811

Chicago/Turabian Style

Muteti-Fana, Shamiso, Jafta Nkosana, and Rajen N. Naidoo. 2023. "Kitchen Characteristics and Practices Associated with Increased PM2.5 Concentration Levels in Zimbabwean Rural Households" International Journal of Environmental Research and Public Health 20, no. 10: 5811. https://doi.org/10.3390/ijerph20105811

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop