Next Article in Journal
High Prevalence and Genetic Polymorphisms of Legionella in Natural and Man-Made Aquatic Environments in Wenzhou, China
Previous Article in Journal
Implementing a Public Health Objective for Alcohol Premises Licensing in Scotland: A Qualitative Study of Strategies, Values, and Perceptions of Evidence
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Simultaneous Detection of Nine Key Bacterial Respiratory Pathogens Using Luminex xTAG® Technology

1
State Key Laboratory for Infectious Disease Prevention and Control, National Institute for Communicable Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
2
Department of Respiratory Medicine, Shengjing Hospital of China Medical University, Shenyang 110004, China
3
Department of Respiratory Medicine, Zhejiang Provincial People’s Hospital, Hangzhou 310014, China
*
Authors to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2017, 14(3), 223; https://doi.org/10.3390/ijerph14030223
Submission received: 22 November 2016 / Revised: 13 February 2017 / Accepted: 20 February 2017 / Published: 23 February 2017
(This article belongs to the Section Environmental Health)

Abstract

:
Early diagnosis and treatment are crucial to the outcome of lower respiratory tract infections (LRTIs). In this study, we developed an assay combining multiplex PCR and Luminex technology (MPLT) for the detection of nine important respiratory bacterial pathogens, which frequently cause LRTIs. These were Streptococcus pneumoniae, Moraxella catarrhalis, Staphylococcus aureus, Streptococcus pyogenes, Haemophilus influenzae, Mycoplasma pneumoniae, Legionella spp., Pseudomonas aeruginosa, and Klebsiella pneumoniae. Through the hybridization reaction between two new synthesized multiplex PCR products and MagPlex-TAG Microspheres, we demonstrate that the detection limits for these nine pathogens were as low as 102–103 CFU/mL. Furthermore, 86 clinical bronchoalveolar lavage fluid specimens were used to evaluate this method. Compared with the results of nine simplex real-time PCR reactions targeting these nine pathogens, this MPLT assay demonstrated a high diagnostic accuracy for Streptococcus pneumoniae (sensitivity, 87.5% and specificity, 100%). Furthermore, sensitivity and specificity for the other eight pathogens all attained 100% diagnostic accuracy. In addition, the consistency between MPLT and the nine real-time PCR reactions exceeded 98.8%. In conclusion, MPLT is a high-throughput, labor-saving and reliable method with high sensitivity and specificity for identifying nine respiratory pathogens responsible for LRTIs. Indeed, this assay may be a promising supplement to conventional methods used to diagnose LRTIs.

1. Introduction

Lower respiratory tract infections (LRTIs) are caused by numerous pathogens and, if untreated, these can progress to severe infections and even death. As reported by The Global Burden of Disease Study, LRTIs were the second-leading cause of deaths in 2013 [1]. The age-standardized mortality rate of LRTIs has been reported to be 41.7 per 100,000 (95% CI 37.1–44.1 per 100,000) [2]. The elderly and people with weakened immune systems are particularly susceptible to these types of infections [3].
A large and increasing number of pathogens, including bacteria, atypical agents and viruses, are responsible for LRTIs [4,5,6]. The clinical presentations and radiology of LRTIs caused by different pathogens are very similar, and this makes it difficult to differentiate these pathogens using only clinical symptoms and lung imaging. The identification of pathogens in severe LRTIs would be of great value in facilitating prompt and successful medical treatment. Therefore, a powerful assay that can simultaneously detect multiple pathogens both quickly and accurately is urgently needed.
Traditional methods used to identify respiratory pathogens include microbial culture, staining methods, urinary antigen tests, and serological tests [7]. These traditional methods can help identify respiratory pathogens to some extent. However, they usually have particular disadvantages: staining methods have poor sensitivity, culture of pathogens is time-consuming, and the specialized culture media for atypical agents and viruses are not accessible in most hospitals and clinical institutions. Serological responses may occur late, thus requiring paired sera at least a week apart, and such serological assays are commonly used in retrospective diagnosis and systematic surveys [8,9].
Molecular methods such as polymerase chain reaction (PCR) and real-time PCR offer high sensitivity and specificity, and have been generated for the rapid identification of respiratory pathogens [10,11,12]. These methods can be used to analyze clinical samples, including sputum, bronchoalveolar lavage fluid (BALF) and blood. However, the throughput of most molecular methods is relatively limited, and most molecular methods cannot detect more than five pathogens in one reaction [10,12,13,14]. Therefore, designing a high-throughput, labor-saving, and rapid method to identify and differentiate respiratory pathogens would be important in enhancing rapid response for the prompt treatment of LRTIs.
Compared with other methods, the Luminex xTAG® technology is a high-throughput, rapid, labor-saving multiplex assay offering both high sensitivity and specificity. This technology is reported to detect up to 100 different targets in a single reaction vessel simultaneously [15,16,17]. This technology is also very useful because of its flexibility in detecting a broad range of pathogens, which means it can be organized into different multiplex assays for different diagnostic targets, as required.
In this study, we aimed to develop a high-throughput and useful multiplex molecular method for the rapid detection of respiratory bacteria of public health importance. We developed an assay combining multiplex PCR and Luminex xTAG® technology (MPLT) for detection of nine key respiratory bacteria, including Streptococcus pneumoniae, Moraxella catarrhalis, Staphylococcus aureus, Streptococcus pyogenes, Haemophilus influenzae, Mycoplasma pneumoniae, Legionella spp., Pseudomonas aeruginosa, and Klebsiella pneumoniae. These pathogens account for most of the respiratory bacteria that precipitate LRTIs [3]. The sensitivity and specificity of the MPLT assay was evaluated, and 86 clinical BALF specimens from LRTI patients were assayed for simultaneous bacteriological detection using the MPLT assay. Using this new method, we compared the results with the data from the nine individual real-time PCRs.

2. Materials and Methods

2.1. Ethics

Ethical approval for this study was obtained from the Institutional Review Boards of the Shengjing Hospital of China Medical University, China (2016PS238K).

2.2. Bacterial Strains

The nine target respiratory bacterial pathogens used in this study are listed in Table 1 (numbered 1 to 9). The other four respiratory bacteria listed in Table 1 (numbered 10 to 13) were used as negative control organisms for the evaluation of specificity. All bacterial organisms and DNA extracts were stored at −80 °C until they were tested.

2.3. Clinical Specimens

A total of 86 clinical BALF specimens were collected from 2014 to 2016 at two hospitals in China. All specimens were obtained from patients with LRTI, including those with pneumonia, acute bronchitis, capillary bronchitis, or other respiratory tract infections. A total of 86 clinical BALF specimens were gathered from 86 individual patients. The following criteria were used to diagnose LRTI: presence of fever and/or an increased leukocyte count (≥11 × 109 /L), increased focal symptoms from the lower airways, with at least one of the following three incident symptoms: increase in dyspnea, coughing, and/or purulent sputum [18]. All clinical BALF specimens were stored at −80 °C until they were tested.

2.4. DNA Extraction

The DNA of 11 bacteria (13 bacteria in Table 1 except for M. pneumoniae and M. tuberculosis complex) was extracted using a QIAamp DNA Mini Kit (Qiagen, Hilden, Germany), according to the manufacturer’s instructions. The 8 bacterial specimens (9 target respiratory pathogens except M. pneumoniae) were serially diluted ten-fold from 108 to 100 CFU/mL, and DNA concentrations were measured by NanoDrop 2000 (Thermo Fisher Scientific, Shanghai, China). The DNA extracts of M. pneumoniae were also diluted ten-fold from 101 ng to 10−6 ng.
The clinical BALF specimens comprised a volume of 1–2 mL, and were centrifuged at 8000 rpm for 10 min; one part of the sediment (200 μL) was used for DNA extraction, which was carried out using the QIAamp blood kit (Qiagen) according to the manufacturer’s instructions (Qiagen). The DNA was eluted in a final volume of 100 μL and stored at −20 °C.

2.5. Primers for Pathogen Amplification

Nine sets of primers were used in this assay. The primers for these nine pathogens were selected from previously published studies, and primers were selected on the basis of having similar melting temperatures so that simultaneous amplification using the same conditions could occur for all multiplex reactions. The expected amplicon sizes were between 94 and 650 bp. It is commonly known that small amplicons provide improved signal intensity and hybridization efficiency in the MPLT system [16,17].
Each forward primer targeting the nine pathogens was modified by a unique 24-base oligonucleotide “TAG” sequence at the 5’ terminus and was used to connect with the MagPlex-xTAG Microsphere (Luminex Corporation, Toronto, ON, Canada). The MagPlex-xTAG Microspheres are MagPlex beads (6.5-micron superparamagnetic beads) where each bead region is covalently pre-coupled with the 24-base oligonucleotide “anti-TAG” sequence (complementary to the “TAG” sequence). A 12-carbon amine was incorporated between the “TAG” sequence and primer. All reverse primers were biotinylated at the 5′ terminus. The primer sequences, their target genes, and the size of the resulting amplicons are shown in Table 2. All primers were synthesized by Tsingke (Beijing, China).

2.6. Multiplex PCR (mPCR) Amplification

First, nine sets of primers targeting the nine target bacterial organisms were confirmed by the simplex PCR reactions. The mPCR was affected by many factors such as annealing time, annealing temperature, and primer concentrations. These conditions were optimized for the mPCR to ensure specific amplification of the selected targets. Finally, two mPCR reactions were generated.
The first multiplex PCR amplification was performed in a total volume of 30 µL containing the following: 15 μL of Premix TaqTM (Takara Bio Inc., Shiga, Japan); 2 µL genomic DNA template; 1 μL of each primer (Table 2) for S. pneumoniae, M. catarrhalis, S. aureus, and S. pyogenes; and 5 μL of distilled water. The mPCR amplification conditions were as follows: denaturation at 95 °C for 10 min; followed by 35 cycles of 95 °C for 30 s, 54 °C for 45 s, and 72 °C for 1 min; a final extension at 72 °C for 10 min was performed. PCR reactions were performed in a ThermoCycler. The reaction products were stored at 4 °C.
The reaction volume of the second mPCR was also 30 µL and it contained 2 µL of genomic DNA template; 15 µL of Premix TaqTM (TaKaRa TaqTM Version 2.0); 1 µL of each primer for H. influenzae, M. pneumoniae, Legionella spp., P. aeruginosa and K. pneumoniae; and 3 µL of distilled water. The mPCR cycling parameters were as follows: denaturation at 95 °C for 10 min; followed by 35 cycles of 95 °C for 30 s, 60 °C for 45 s, and 72 °C for 1 min; a final extension at 72 °C for 10 min was performed. PCR reactions were performed in a ThermoCycler. The reaction products were stored at 4 °C.

2.7. PCR Product Identification

To examine the amplified DNA, the reaction products were resolved on a 2.0% agarose gel stained with GoldView, visualized under UV light, and analyzed using a Gel Doc system (BioRad, Hercules, CA, USA). The target gene fragments for S. pneumoniae, M. catarrhalis, S. aureus, S. pyogenes, H. influenzae, M. pneumoniae, Legionella spp., P. aeruginosa, and K. pneumoniae were 350 bp, 140 bp, 270 bp, 93 bp, 296 bp, 209 bp, 650 bp, 504 bp, and 364 bp, respectively.

2.8. Luminex Assay

The PCR-Luminex assay procedure can be read on the Luminex Corporation website (http://info.luminexcorp.com/download-the-xmap-cookbook). The assay was conducted according to these instructions.
The amplified sequences were labeled with the fluorescent reporter and hybridization to MagPlex-TAG Microspheres, which were pre-coupled with “anti-TAG” sequences. A bead mixture consisted of 2500 Microspheres of each set, per reaction. The working MagPlex-xTAG Microsphere mixture was prepared by diluting microspheres to 125 of each microsphere per set per μL in 1× Tm Hybridization Buffer (0.2 M NaCl, 0.1 M Tris, 0.08% Triton X-100, pH 8.0, filter sterilized) and was then vortexed for 20 s. The pink indicator was composed of diluting Streptavidin, R-Phycoerythrin Conjugate (SAPE, Invitrogen Corporation, Carlsbad, CA, USA) to 10 μg/mL in 1× Tm Hybridization Buffer. For each reaction, 5 μL of each amplified PCR product or distilled water, 75 μL of pink SAPE solution, and 20 μL of the MagPlex-TAG Microsphere mixture were added together before mixing in a 100 μL reaction tube (Applied Biosystem Corporation, Foster City, CA, USA). Finally, the MagPlex-TAG Microsphere-PCR product-SAPE mixtures were incubated and hybridized in a thermocycler for 30 min at 40 °C. After the hybridization reaction, the products were analyzed on the Luminex 200 analyzer (Luminex Corporation, Toronto, ON, Canada) according to the system manual. The sample size was set to 100 µL with a minimum of 100 beads per target to be analyzed.

2.9. MPLT Data Analysis

The data analyzed by the Luminex xPONENT software, version 3.1 (Luminex Corporation) were reported as median fluorescence intensity (MFI). The cut-off values for nine target pathogens were obtained from the mean MFIs of 46 no-template controls run during the study period, and the determination of cut-off values were also referred to from previous studies [30,31,32]. A corrected MFI (cMFI) which was normalized to background fluorescence were defined as follows: cMFI = [MFI (sample) − MFI (background)]/MFI (background). Additionally, the cMFI values of samples were shown as the mean ± standard error of the mean (SEM).

2.10. The Evaluation of Sensitivity

To determine the sensitivities of the MPLT assay, serial ten-fold dilutions (108–100 CFU/mL) of the 8 target bacterial DNA samples (9 target bacteria except for M. pneumoniae) with known starting concentrations were extracted. The M. pneumoniae DNA was diluted to different concentrations from 102 ng/μL to 10−6 ng/μL. For all DNA samples in this study, they were used as the templates. The sensitivity results were confirmed in triplicate.

2.11. The Evaluation of Specificity

The bacterial species used to assess the specificity of the assay are listed in Table 1. For each pathogen, monoplex PCR assays were performed with its own target DNA, and negative controls (other DNA excepting the target template) were simultaneously tested for each organism. To determine the specificity of the MPLT assay, DNA from the 9 bacteria were analyzed in the two mPCR reactions and after amplification, the 9 mPCR products (5 μL each) were mixed with the MagPlex-TAG Microsphere and SAPE mixtures, before further analysis on the Luminex 200 analyzer.

2.12. Detection of DNA from Clinical BALF Samples

A total of 86 BALF samples were collected from two hospitals in China. DNA was extracted from the samples and tested by both the MPLT assay and the single real-time PCR assays.

2.13. Real-Time PCR for Bacterial Detection

The 9 pairs of specific primers and probes used in 9 single real-time PCR reactions are shown in Table 3. We used a Stratagene Mx3000P PCR system (Stratagene, La Jolla, CA, USA) for the real-time PCR assay. The reaction system comprised 12.5 μL of Premix Ex Taq (Takara) and 1.25 μL of each primer and fluorescent probe. The final volume of the system was adjusted to 25 μL with 0.5 μL of ROX Reference Dye II (Takara) and distilled water. The specificities of the 9 real-time PCR reactions have been confirmed in previous studies [33,34,35,36,37,38], and the relevant references are listed in Table 3. The analytical sensitivities for these 9 pathogens were measured by ten-fold serial dilutions (108–100 CFU/mL) of the 8 target bacterial DNA samples (9 target bacteria except for M. pneumoniae), and the M. pneumoniae DNA diluted from 102 ng/μL to 10−6 ng/μL. The threshold cycle (CT) values of all the dilutions for these 9 pathogens were confirmed in triplicate. All the reaction systems, amplification conditions and results of these nine real-time PCR assays are listed in Supplementary Materials.

2.14. Statistical Analyses

Consistency between the results of the MPLT assay and real-time PCR assays was verified using Cohen’s kappa test in SPSS software, version 17.0 (IBM SPSS, Armonk, NY, USA). The kappa value was graded as follows: <0, no agreement; 0–0.20, slight; 0.21–0.40, fair; 0.41–0.60, moderate; 0.61–0.80, substantial; and 0.81–1, almost perfect agreement.

3. Results

3.1. Specificity of the Two mPCR Assays and the MPLT Assay

First, nine sets of specific primers and DNA templates extracted from thirteen respiratory pathogens were used and the specificity of nine primers was confirmed using nine simplex PCR reactions. Then, two mPCR reactions were generated. The resultant amplicon sizes from the two mPCR reactions for the pathogens were similar to their corresponding target sequences in Table 2. The results (Figure 1) showed that these two mPCR reactions were feasible and could achieve effective amplification for nine target respiratory pathogens with no cross-reactions being observed. The MPLT assay for each target pathogen (Figure 2A,B) showed a single and specific fluorescence signal. Cross hybridization and non-specific hybridization between sequences was not observed.

3.2. Sensitivity of the MPLT Assay

The sensitivity of the MPLT assay was examined by testing serial ten-fold dilutions of the nine target bacterial DNA samples, and distilled water was used as negative control. The detection limits in the MPLT assay are demonstrated in Figure 3A–I. The results showed that the limit of detection was 102 CFU/mL for S. pneumoniae, M. catarrhalis, S. aureus and K. pneumoniae and 103 CFU/mL for S. pyogenes, H. influenzae, Legionella spp. and P. aeruginosa. Finally, the detection limit for M. pneumoniae was 10−3 ng/μL.

3.3. Application to Clinical Samples

A total of 86 clinical BALF specimens were analyzed using the MPLT assay on the Luminex 200 analyzer. The results were confirmed by the simplex real-time PCR for the nine pathogens. The MPLT assay successfully detected and differentiated between all nine target respiratory pathogens. Compared with the results of the simplex real-time PCR, the consistency of MPLT assay exceeded 98.8% for all nine target pathogens (Table 4).
For S. pneumoniae, 8 of 86 clinical BALF samples were considered to be positive by MPLT assay, while 7 of 86 clinical BALF samples were detected as positive by the simplex real-time PCR assay. Furthermore, the sample which was considered to be positive by the MPLT assay but negative by the real-time PCR assay was then confirmed as a true positive by 16S rDNA sequence analysis. Coinfections were identified in 10 samples for both MPLT assay and real-time PCR assay.
The MPLT assay and the simplex real-time PCR assay both identified the same number of positive samples for S. aureus, H. influenzae, M. pneumonia, P. aeruginosa and K. pneumoniae.
The obtained sensitivity and specificity of this MPLT assay relative to those of real-time PCR were as follows: 87.5% and 100% for S. pneumoniae, and 100% and 100% for S. aureus, H. influenzae, M. pneumonia, P. aeruginosa and K. pneumoniae, respectively.

4. Discussion

S. pneumoniae, M. catarrhalis, S. aureus, S. pyogenes, H. influenzae, M. pneumoniae, Legionella spp., P. aeruginosa, and K. pneumoniae are the most commonly reported causative respiratory pathogens in LRTI worldwide [2,3,4,5,6]. All these bacteria have similar clinical features, and may cause multiple infections, which may increase their morbidity. Etiologic diagnosis of the causative pathogen for LRTI can pose problems, with causative organisms identified in approximately 50% of community-acquired pneumonia (CAP) cases [39,40,41]. Indeed for LRTI, the proportion of identified organisms is even lower. This is mainly due to difficulties in generating efficient associated methods that have both high sensitivity and good specificity for detection of these pathogens.
The Luminex xTAG® platform is a rapid, accurate and high-throughput nucleic acid detection method which permits multiplex PCR analysis, therefore it is both attractive and reproducible. Furthermore, this method can be expanded to include more pathogens, further increasing the potential ability of the diagnostic platform. Recently, several commercial kits have been developed based on this technology. For example, the Luminex xTAG® Gastrointestinal Pathogen Panel (xTAG® GPP) can detect the 15 most common gastrointestinal pathogens and toxins in a single assay [42]. The Luminex xTAG® Cerebrospinal Fluid Pathogens Bacterial Panel (xTAG® CSF Bacteria) and the Luminex xTAG® Cerebrospinal Fluid Pathogens Viral Panel (xTAG® CSF Virus) can be used to detect common bacterial and viral pathogens from cerebrospinal fluid [30,31]. The Luminex xTAG® Bloodstream Pathogen Panel (xTAG® BPP) can be used to detect 23 pathogens commonly identified in bloodstream infections [43]. Previously, the Luminex xTAG® technology has been successfully applied to simultaneously detect 18 respiratory viral pathogens (xTAG® RVP FAST v2) [44]. However, there are still no commercially-available kits to detect respiratory bacterial pathogens. Recently, a Luminex assay for the detection of pathogens in acute respiratory tract infections has been built [45], however the target respiratory bacterial pathogens for this assay are limited. In addition to S. pneumoniae, S. aureus, M. pneumoniae, P. aeruginosa, and K. pneumoniae mentioned in this assay, we also involved M. catarrhalis, S. pyogenes, Legionella spp., H. influenzae as our target respiratory bacterial pathogens. Now, we have successfully generated this MPLT assay to investigate nine bacterial pathogens responsible for LRTI using this Luminex xTAG® technology.
Other analysis platforms, such as the flow-based microarray analysis platform MCR 3 [46] and stopped polymerase chain reaction combined with chemiluminescence flow-through DNA microarray analysis platform [47], have been built. Compared with our Luminex platform, all these platfoms are characterized by low limits of detection, high reproducibility and reduced assay time [46,47]. Although multiplex real-time PCR is a direct format and is cheaper than Luminex technology, the throughput of it is low. Furthermore, due to the limitation of its fluorescence, it can detect only a limited number of bacterial pathogens in one reaction [10,12,13,14].
The results of our study showed that this MPLT assay had high specificity, sensitivity and excellent consistency compared to the real-time PCR reaction. Furthermore, we found the detection limits for these nine pathogens were as low as 102–103 CFU/mL (10−3–10−4 ng/μL). These results strongly suggest that the development of the MPLT assay for identification of these nine pathogens is both feasible and useful.
The sensitivity and specificity of Luminex technology is closely related to primers [48,49,50,51], and good, specific primers can avoid non-specific amplification while ensuring stability of the assay. Consequently, the primers used in our assay were carefully selected from different primers, according to the GC content of the primers and the annealing temperature. In addition, the results of the MPLT assay also showed that all primers were chosen appropriately and the nine target pathogens could be detected effectively.
A previous study [52] showed that a ten-plex PCR-coupled liquid bead array system had lower detection limits than a single PCR. Therefore, it was important in this study to optimise the conditions of the multiplex PCR reactions. To ensure the specificity and sensitivity of this developed MPLT assay, we also optimized the hybridization reaction conditions and confirmed that 40 °C was the optimal hybridization temperature, while 30 min appeared to be the optimal hybridization time. Furthermore, proper MagPlex-TAG Microspheres were chosen for this assay, which appear to be an essential constituent of this diagnostic platform.
A total of 86 BALF samples collected over three years from patients with LRTIs were investigated by MPLT, and we found that eight samples were diagnostically positive for S. pneumoniae, 11 samples were positive for S. aureus, eight samples were positive for H. influenzae, one sample was positive for M. pneumoniae, 10 samples were positive for P. aeruginosa and five samples were positive for K. pneumoniae. Of these diagnoses, most of the results (42/43 (97.7%)) obtained from the MPLT method were consistent with those from real-time PCR assay. The only conflicting result, which was MPLT-positive but negative by the real-time PCR assay, was eventually confirmed as a true positive by 16S rDNA sequence analysis. From these data, we demonstrated that the MPLT assay had a high diagnostic accuracy for S. pneumoniae, S. aureus, M. catarrhalis, S. pyogenes, H. influenzae, M. pneumoniae, Legionella spp., P. aeruginosa and K. pneumoniae, respectively. The MPLT assay could simultaneously detect nine pathogens using a quick, high-throughput assay.
The limitation of the MPLT assay is that the cost of MagPlex-TAG Microspheres and Luminex equipment used in this MPLT assay is relatively high. Although the initial outlay is expensive, this assay might be economical by ensuring prompt and effective treatment of LRTIs before they develop into serious diseases. Despite the limitation, the MPLT assay is a high-throughput method that can detect a wide range of pathogens and is easy to operate with high reliability. Based on the findings of the present study, we believe this is a promising method with potential use in the clinical setting in identifying respiratory pathogens that frequently precipitate LRTI.

5. Conclusions

We have established a high-throughput, labor-saving, rapid (3 h) and reliable MPLT assay with high sensitivity and specificity for the identification of nine common respiratory pathogens responsible for LRTIs. This study gives an insight into a diagnostic platform that could be a promising adjunct to the conventional and molecular methods for diagnosing LRTIs.

Supplementary Materials

The following are available online at www.mdpi.com/1660-4601/14/3/223/s1, Real-time PCR assays for detection of nine respiratory pathogens.

Acknowledgments

This work was supported by the Priority Project on Infectious Disease Control and Prevention (grant numbers 2012ZX10004215, 2013ZX10004610) from Ministry of Health, China, the Science Foundation for the State Key Laboratory for Infectious Disease Prevention and Control of China (grant number 2015SKLID508), and the National Natural Science Foundation of China (grant numbers 81671985, 81201251, 81170009).

Author Contributions

Luxi Jiang, Hongyu Ren and Haijian Zhou designed and conducted the experiments, collected and analyzed the data, and wrote the paper. Haijian Zhou, Tian Qin and Yu Chen designed the experiments and contributed to revising the paper. Luxi Jiang, Hongyu Ren, Haijian Zhou, Tian Qin and Yu Chen conducted the experiments, collected and processed the clinical specimens.

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

LRTIlower respiratory tract infection
LRTIslower respiratory tract infections
MPLTmultiplex PCR and Luminex technology
PCRpolymerase chain reaction
BALFbronchoalveolar lavage fluid
S. pneumoniaStreptococcus pneumoniae
M. catarrhalisMoraxella catarrhalis
S. aureusStaphylococcus aureus
S. pyogenesStreptococcus pyogenes
H. influenzaHaemophilus influenzae
M. pneumoniaMycoplasma pneumoniae
P. aeruginosaPseudomonas aeruginosa
K. pneumoniaKlebsiella pneumoniae
mPCRmultiplex PCR; SAPE, Streptavidin, R-Phycoerythrin Conjugate
MFImedian fluorescence intensity
cMFIcorrected MFI
SEMstandard error of the mean
CFUcolony forming unit
Ctthreshold cycle

References

  1. Woodhead, M.; Blasi, F.; Ewig, S.; Garau, J.; Huchon, G.; Ieven, M.; Ortqvist, A.; Schaberg, T.; Torres, A.; van der Heijden, G.; et al. Joint Taskforce of the European Respiratory Society and European Society for Clinical Microbiology and Infectious Diseases Guidelines for the management of adult lower respiratory tract infections—Full version. Clin. Microbiol. Infect. 2011, 17, E1–E59. [Google Scholar] [CrossRef] [PubMed]
  2. Prina, E.; Ranzani, O.T.; Torres, A. Community-acquired pneumonia. Lancet 2015, 386, 1097–1108. [Google Scholar] [CrossRef]
  3. Carroll, K.C. Laboratory diagnosis of lower respiratory tract infections: Controversy and conundrums. J. Clin. Microbiol. 2002, 40, 3115–3120. [Google Scholar] [CrossRef] [PubMed]
  4. Johansson, N.; Kalin, M.; Tiveljung-Lindell, A.; Giske, C.G.; Hedlund, J. Etiology of community-acquired pneumonia: Increased microbiological yield with new diagnostic methods. Clin. Infect. Dis. 2010, 50, 202–209. [Google Scholar] [CrossRef] [PubMed]
  5. Lim, W.S.; Baudouin, S.V.; George, R.C.; Hill, A.T.; Jamieson, C.; Le Jeune, I.; Macfarlane, J.T.; Read, R.C.; Roberts, H.J.; Levy, M.L.; et al. Pneumonia Guidelines Committee of the BTS Standards of Care Committee BTS guidelines for the management of community acquired pneumonia in adults: Update 2009. Thorax 2009, 64, iii1–iii55. [Google Scholar] [CrossRef] [PubMed]
  6. Mandell, L.A.; Wunderink, R.G.; Anzueto, A.; Bartlett, J.G.; Campbell, G.D.; Dean, N.C.; Dowell, S.F.; File, T.M.; Musher, D.M.; Niederman, M.S.; et al. Infectious Diseases Society of America/American Thoracic Society Consensus Guidelines on the Management of Community-Acquired Pneumonia in Adults. Clin. Infect. Dis. 2007, 44, S27–S72. [Google Scholar] [CrossRef] [PubMed]
  7. Mandell, L.A. Community-acquired pneumonia: An overview. Postgrad. Med. 2015, 127, 607–615. [Google Scholar] [CrossRef] [PubMed]
  8. Strålin, K. Usefulness of aetiological tests for guiding antibiotic therapy in community-acquired pneumonia. Int. J. Antimicrob. Agents 2008, 31, 3–11. [Google Scholar] [CrossRef] [PubMed]
  9. Saranglao, A.; Smith, P.R. Diagnostic tests for CAP: Current approaches and future perspectives. Expert Rev. Mol. Diagn. 2002, 2, 329–336. [Google Scholar] [CrossRef] [PubMed]
  10. Pai, R.; Gertz, R.E.; Beall, B. Sequential multiplex PCR approach for determining capsular serotypes of Streptococcus pneumoniae isolates. J. Clin. Microbiol. 2006, 44, 124–131. [Google Scholar] [CrossRef] [PubMed]
  11. Mangold, K.A.; Santiano, K.; Broekman, R.; Krafft, C.A.; Voss, B.; Wang, V.; Hacek, D.M.; Usacheva, E.A.; Thomson, R.B.; Kaul, K.L.; et al. Real-time detection of blaKPC in clinical samples and surveillance specimens. J. Clin. Microbiol. 2011, 49, 3338–3339. [Google Scholar] [CrossRef] [PubMed]
  12. Thong, K.L.; Lai, M.Y.; Teh, C.S.J.; Chua, K.H. Simultaneous detection of methicillin-resistant Staphylococcus aureus, Acinetobacter baumannii, Escherichia coli, Klebsiella pneumoniae and Pseudomonas aeruginosa by multiplex PCR. Trop. Biomed. 2011, 28, 21–31. [Google Scholar] [PubMed]
  13. Tian, G.Z.; Zhang, L.J.; Wang, X.L.; Zhang, L.; Li, S.F.; Gu, C.M.; Sun, J.; Cui, B.Y. Rapid detection of Haemophilus influenzae and Haemophilus parainfluenzae in nasopharyngeal swabs by multiplex PCR. Biomed. Environ. Sci. 2012, 25, 367–371. [Google Scholar] [PubMed]
  14. Gok, U.; Bulut, Y.; Keles, E.; Yalcin, S.; Doymaz, M.Z. Bacteriological and PCR analysis of clinical material aspirated from otitis media with effusions. Int. J. Pediatr. Otorhinolaryngol. 2001, 60, 49–54. [Google Scholar] [CrossRef]
  15. Lynch, H.E.; Sanchez, A.M.; D’Souza, M.P.; Rountree, W.; Denny, T.N.; Kalos, M.; Sempowski, G.D. Development and implementation of a proficiency testing program for Luminex bead-based cytokine assays. J. Immunol. Methods 2014, 409, 62–71. [Google Scholar] [CrossRef] [PubMed]
  16. Bai, X.; Liu, Z.; Ji, S.; Gottschalk, M.; Zheng, H.; Xu, J. Simultaneous detection of 33 Streptococcus suis serotypes using the luminex xTAG® assayTM. J. Microbiol. Methods 2015, 117, 95–99. [Google Scholar] [CrossRef] [PubMed]
  17. Dunbar, S.A. Applications of Luminex xMAP technology for rapid, high-throughput multiplexed nucleic acid detection. Clin. Chim. Acta 2006, 363, 71–82. [Google Scholar] [CrossRef] [PubMed]
  18. Abdeldaim, G.M.K.; Strålin, K.; Korsgaard, J.; Blomberg, J.; Welinder-Olsson, C.; Herrmann, B. Multiplex quantitative PCR for detection of lower respiratory tract infection and meningitis caused by Streptococcus pneumoniae, Haemophilus influenzae and Neisseria meningitidis. BMC Microbiol. 2010, 10, 310. [Google Scholar] [CrossRef] [PubMed]
  19. Park, H.K.; Lee, S.-J.; Yoon, J.W.; Shin, J.W.; Shin, H.-S.; Kook, J.-K.; Myung, S.C.; Kim, W. Identification of the cpsA gene as a specific marker for the discrimination of Streptococcus pneumoniae from viridans group streptococci. J. Med. Microbiol. 2010, 59, 1146–1152. [Google Scholar] [CrossRef] [PubMed]
  20. Hall-Stoodley, L.; Hu, F.Z.; Gieseke, A.; Nistico, L.; Nguyen, D.; Hayes, J.; Forbes, M.; Greenberg, D.P.; Dice, B.; Burrows, A.; et al. Direct detection of bacterial biofilms on the middle-ear mucosa of children with chronic otitis media. JAMA 2006, 296, 202–211. [Google Scholar] [CrossRef] [PubMed]
  21. Brakstad, O.G.; Aasbakk, K.; Maeland, J.A. Detection of Staphylococcus aureus by polymerase chain reaction amplification of the nuc gene. J. Clin. Microbiol. 1992, 30, 1654–1660. [Google Scholar] [PubMed]
  22. Karmakar, A.; Dua, P.; Ghosh, C. Biochemical and Molecular Analysis of Staphylococcus aureus Clinical Isolates from Hospitalized Patients. Can. J. Infect. Dis. Med. Microbiol. 2016, 2016, 9041636. [Google Scholar] [PubMed]
  23. Slinger, R.; Goldfarb, D.; Rajakumar, D.; Moldovan, I.; Barrowman, N.; Tam, R.; Chan, F. Rapid PCR detection of group A Streptococcus from flocked throat swabs: A retrospective clinical study. Ann. Clin. Microbiol. Antimicrob. 2011, 10, 33. [Google Scholar] [CrossRef] [PubMed]
  24. Strålin, K.; Bäckman, A.; Holmberg, H.; Fredlund, H.; Olcén, P. Design of a multiplex PCR for Streptococcus pneumoniae, Haemophilus influenzae, Mycoplasma pneumoniae and Chlamydophila pneumoniae to be used on sputum samples. APMIS 2005, 113, 99–111. [Google Scholar] [CrossRef] [PubMed]
  25. Ursi, J.P.; Ursi, D.; Ieven, M.; Pattyn, S.R. Utility of an internal control for the polymerase chain reaction. Application to detection of Mycoplasma pneumoniae in clinical specimens. APMIS 1992, 100, 635–639. [Google Scholar] [CrossRef] [PubMed]
  26. Loens, K.; Ursi, D.; Goossens, H.; Ieven, M. Molecular diagnosis of Mycoplasma pneumoniae respiratory tract infections. J. Clin. Microbiol. 2003, 41, 4915–4923. [Google Scholar] [CrossRef] [PubMed]
  27. Rafiee, M.; Jahangiri-Rad, M.; Hajjaran, H.; Mesdaghinia, A.; Hajaghazadeh, M. Detection and identification of Legionella species in hospital water supplies through Polymerase Chain Reaction (16S rRNA). J. Environ. Health Sci. Eng. 2014, 12, 83. [Google Scholar] [CrossRef]
  28. De Vos, D.; Lim, A.; Pirnay, J.P.; Struelens, M.; Vandenvelde, C.; Duinslaeger, L.; Vanderkelen, A.; Cornelis, P. Direct detection and identification of Pseudomonas aeruginosa in clinical samples such as skin biopsy specimens and expectorations by multiplex PCR based on two outer membrane lipoprotein genes, oprI and oprL. J. Clin. Microbiol. 1997, 35, 1295–1299. [Google Scholar] [PubMed]
  29. Sun, Z.; Chen, Z.; Hou, X.; Li, S.; Zhu, H.; Qian, J.; Lu, D.; Liu, W. Locked nucleic acid pentamers as universal PCR primers for genomic DNA amplification. PLoS ONE 2008, 3. [Google Scholar] [CrossRef] [PubMed]
  30. Bøving, M.K.; Pedersen, L.N.; Møller, J.K. Eight-plex PCR and liquid-array detection of bacterial and viral pathogens in cerebrospinal fluid from patients with suspected meningitis. J. Clin. Microbiol. 2009, 47, 908–913. [Google Scholar] [CrossRef] [PubMed]
  31. Taniuchi, M.; Verweij, J.J.; Sethabutr, O.; Bodhidatta, L.; Garcia, L.; Maro, A.; Kumburu, H.; Gratz, J.; Kibiki, G.; Houpt, E.R. Multiplex polymerase chain reaction method to detect Cyclospora, Cystoisospora, and Microsporidia in stool samples. Diagn. Microbiol. Infect. Dis. 2011, 71, 386–390. [Google Scholar] [CrossRef] [PubMed]
  32. Zhou, L.; Wu, R.; Shi, X.; Feng, D.; Feng, G.; Yang, Y.; Dai, W.; Bian, T.; Liu, T.; He, Y.; et al. Simultaneous Detection of Five Pathogens from Cerebrospinal Fluid Specimens Using Luminex Technology. Int. J. Environ. Res. Public Health 2016, 13, 193. [Google Scholar] [CrossRef] [PubMed]
  33. Maria da Gloria, S.C.; Tondella, M.L.; McCaustland, K.; Weidlich, L.; McGee, L.; Mayer, L.W.; Steigerwalt, A.; Whaley, M.; Facklam, R.R.; Fields, B. Evaluation and improvement of real-time PCR assays targeting lytA, ply, and psaA genes for detection of pneumococcal DNA. J. Clin. Microbiol. 2007, 45, 2460–2466. [Google Scholar]
  34. Hirama, T.; Yamaguchi, T.; Miyazawa, H.; Tanaka, T.; Hashikita, G.; Kishi, E.; Tachi, Y.; Takahashi, S.; Kodama, K.; Egashira, H.; et al. Prediction of the pathogens that are the cause of pneumonia by the battlefield hypothesis. PLoS ONE 2011, 6, e24474. [Google Scholar] [CrossRef] [PubMed]
  35. Chiba, N.; Murayama, S.Y.; Morozumi, M.; Nakayama, E.; Okada, T.; Iwata, S.; Sunakawa, K.; Ubukata, K. Rapid detection of eight causative pathogens for the diagnosis of bacterial meningitis by real-time PCR. J. Infect. Chemother. 2009, 15, 92–98. [Google Scholar] [CrossRef] [PubMed]
  36. Gosiewski, T.; Szaał, L.; Pietrzyk, A.; Brzychczy-Wołch, M.; Heczko, P.B.; Bulanda, M. Comparison of methods for isolation of bacterial and fungal DNA from human blood. Curr. Microbiol. 2014, 68, 149–155. [Google Scholar] [CrossRef] [PubMed]
  37. Morozumi, M.; Nakayama, E.; Iwata, S.; Aoki, Y.; Hasegawa, K.; Kobayashi, R.; Chiba, N.; Tajima, T.; Ubukata, K. Simultaneous detection of pathogens in clinical samples from patients with community-acquired pneumonia by real-time PCR with pathogen-specific molecular beacon probes. J. Clin. Microbiol. 2006, 44, 1440–1446. [Google Scholar] [CrossRef] [PubMed]
  38. Welti, M.; Jaton, K.; Altwegg, M.; Sahli, R.; Wenger, A.; Bille, J. Development of a multiplex real-time quantitative PCR assay to detect Chlamydia pneumoniae, Legionella pneumophila and Mycoplasma pneumoniae in respiratory tract secretions. Diagn. Microbiol. Infect. Dis. 2003, 45, 85–95. [Google Scholar] [CrossRef]
  39. Al-Marzooq, F.; Imad, M.A.M.; How, S.H.; Kuan, Y.C. Development of multiplex real-time PCR for the rapid detection of five bacterial causes of community acquired pneumonia. Trop. Biomed. 2011, 28, 545–556. [Google Scholar] [PubMed]
  40. Nolte, F.S. Molecular diagnostics for detection of bacterial and viral pathogens in community-acquired pneumonia. Clin. Infect. Dis. 2008, 47, S123–S126. [Google Scholar] [CrossRef] [PubMed]
  41. Chan, Y.R.; Morris, A. Molecular diagnostic methods in pneumonia. Curr. Opin. Infect. Dis. 2007, 20, 157–164. [Google Scholar] [CrossRef] [PubMed]
  42. Wessels, E.; Rusman, L.G.; Bussel, M.J.; Claas, E.C. Added value of multiplex Luminex Gastrointestinal Pathogen Panel (xTAG® GPP) testing in the diagnosis of infectious gastroenteritis. Clin. Microbiol. Infect. 2014, 20, O182–O187. [Google Scholar] [CrossRef] [PubMed]
  43. Stentzel, S.; Sundaramoorthy, N.; Michalik, S.; Nordengrün, M.; Schulz, S.; Kolata, J.; Kloppot, P.; Engelmann, S.; Steil, L.; Hecker, M.; et al. Specific serum IgG at diagnosis of Staphylococcus aureus bloodstream invasion is correlated with disease progression. J. Proteom. 2015, 128, 1–7. [Google Scholar] [CrossRef] [PubMed]
  44. Jokela, P.; Piiparinen, H.; Mannonen, L.; Auvinen, E.; Lappalainen, M. Performance of the Luminex xTAG Respiratory Viral Panel Fast in a clinical laboratory setting. J. Virol. Methods 2012, 182, 82–86. [Google Scholar] [CrossRef] [PubMed]
  45. Chen, Y.-S.; Li, H.-R.; Zhang, W.; Hua, Z.-D.; Lin, X.-H.; Lin, M.-Q.; Huang, W.-S.; Huang, L.-P.; Yu, X.-L.; Xu, N.-L.; et al. Development of a bead-based suspension array for the detection of pathogens in acute respiratory tract infections. Exp. Biol. Med. 2016, 241, 1551–1558. [Google Scholar] [CrossRef] [PubMed]
  46. Lengger, S.; Otto, J.; Elsässer, D.; Schneider, O.; Tiehm, A.; Fleischer, J.; Niessner, R.; Seidel, M. Oligonucleotide microarray chip for the quantification of MS2, ΦX174, and adenoviruses on the multiplex analysis platform MCR 3. Anal. Bioanal. Chem. 2014, 406, 3323–3334. [Google Scholar] [CrossRef] [PubMed]
  47. Donhauser, S.C.; Niessner, R.; Seidel, M. Sensitive quantification of Escherichia coli O157:H7, Salmonella enterica, and Campylobacter jejuni by combining stopped polymerase chain reaction with chemiluminescence flow-through DNA microarray analysis. Anal. Chem. 2011, 83, 3153–3160. [Google Scholar] [CrossRef] [PubMed]
  48. Booth, S.A.; Drebot, M.A.; Martin, I.E.; Ng, L.K. Design of oligonucleotide arrays to detect point mutations: Molecular typing of antibiotic resistant strains of Neisseria gonorrhoeae and hantavirus infected deer mice. Mol. Cell. Probes 2003, 17, 77–84. [Google Scholar] [CrossRef]
  49. Chou, C.-C.; Chen, C.-H.; Lee, T.-T.; Peck, K. Optimization of probe length and the number of probes per gene for optimal microarray analysis of gene expression. Nucleic Acids Res. 2004, 32, e99. [Google Scholar] [CrossRef] [PubMed]
  50. Binder, H.; Preibisch, S. Specific and nonspecific hybridization of oligonucleotide probes on microarrays. Biophys. J. 2005, 89, 337–352. [Google Scholar] [CrossRef] [PubMed]
  51. Steel, A.B.; Levicky, R.L.; Herne, T.M.; Tarlov, M.J. Immobilization of nucleic acids at solid surfaces: Effect of oligonucleotide length on layer assembly. Biophys. J. 2000, 79, 975–981. [Google Scholar] [CrossRef]
  52. Wilson, W.J.; Erler, A.M.; Nasarabadi, S.L.; Skowronski, E.W.; Imbro, P.M. A multiplexed PCR-coupled liquid bead array for the simultaneous detection of four biothreat agents. Mol. Cell. Probes 2005, 19, 137–144. [Google Scholar] [CrossRef] [PubMed]
Figure 1. Results of the two mPCR reactions for nine target pathogens. Agarose gel electrophoresis showing the results of the four-plex PCR amplification and five-plex PCR amplification. Each DNA sample was successfully amplified and lanes are as follows: M, DNA Marker 100; 1, S. pneumoniae 350 bp; 2, M. catarrhalis 140 bp; 3, S. aureus 270 bp; 4, S. pyogenes 93 bp; B, negative control (distilled water); M, DNA Marker 100; 5, H. influenzae 296 bp; 6, M. pneumoniae 209 bp; 7, Legionella spp. 650 bp; 8, P. aeruginosa 249 bp; 9, K. pneumoniae 364 bp; B, negative control (distilled water).
Figure 1. Results of the two mPCR reactions for nine target pathogens. Agarose gel electrophoresis showing the results of the four-plex PCR amplification and five-plex PCR amplification. Each DNA sample was successfully amplified and lanes are as follows: M, DNA Marker 100; 1, S. pneumoniae 350 bp; 2, M. catarrhalis 140 bp; 3, S. aureus 270 bp; 4, S. pyogenes 93 bp; B, negative control (distilled water); M, DNA Marker 100; 5, H. influenzae 296 bp; 6, M. pneumoniae 209 bp; 7, Legionella spp. 650 bp; 8, P. aeruginosa 249 bp; 9, K. pneumoniae 364 bp; B, negative control (distilled water).
Ijerph 14 00223 g001
Figure 2. Results of the MPLT assay for nine target pathogens. (A) Detection of target products by the four-plex PCR-Luminex showed a high specificity. Distilled water was used as the negative control (NC). Each bar represents the average median fluorescence intensity (MFI) of triplicate samples. The error bars indicate standard deviations. SP, S. pneumoniae; MC, M. catarrhalis; SA, S. aureus; SPY, S. pyogenes; (B) Detection of target products by the five-plex PCR-Luminex showed a high specificity. Distilled water was used as the negative control (NC). Each bar represents the average MFI of triplicate samples. The error bars indicate standard deviations. HI, H. influenzae; MP, M. pneumoniae; LP, Legionella spp.; PA, P. aeruginosa; KP, K. pneumonia.
Figure 2. Results of the MPLT assay for nine target pathogens. (A) Detection of target products by the four-plex PCR-Luminex showed a high specificity. Distilled water was used as the negative control (NC). Each bar represents the average median fluorescence intensity (MFI) of triplicate samples. The error bars indicate standard deviations. SP, S. pneumoniae; MC, M. catarrhalis; SA, S. aureus; SPY, S. pyogenes; (B) Detection of target products by the five-plex PCR-Luminex showed a high specificity. Distilled water was used as the negative control (NC). Each bar represents the average MFI of triplicate samples. The error bars indicate standard deviations. HI, H. influenzae; MP, M. pneumoniae; LP, Legionella spp.; PA, P. aeruginosa; KP, K. pneumonia.
Ijerph 14 00223 g002
Figure 3. Sensitivity of the nine target bacteria in MPLT assay. Correlation of Ct values derived from the real-time PCR assay and different bacterial concentration. (A) S. pneumoniae; (B) M. catarrhalis; (C) S. aureus; (D) S. pyogenes; (E) H. influenzae; (F) M. pneumoniae (DNA); (G) Legionella spp.; (H) P. aeruginosa; (I) K. pneumoniae. Cut-off cMFI = 3.0. All samples were performed in triplicate. If the results from a duplicate sample analysis exceeded the cut-off cMFI, the sample was defined as MPLT-positive.
Figure 3. Sensitivity of the nine target bacteria in MPLT assay. Correlation of Ct values derived from the real-time PCR assay and different bacterial concentration. (A) S. pneumoniae; (B) M. catarrhalis; (C) S. aureus; (D) S. pyogenes; (E) H. influenzae; (F) M. pneumoniae (DNA); (G) Legionella spp.; (H) P. aeruginosa; (I) K. pneumoniae. Cut-off cMFI = 3.0. All samples were performed in triplicate. If the results from a duplicate sample analysis exceeded the cut-off cMFI, the sample was defined as MPLT-positive.
Ijerph 14 00223 g003
Table 1. List of bacterial pathogens used in this study.
Table 1. List of bacterial pathogens used in this study.
NumberSpeciesStrain ID and Description
1Streptococcus pneumoniaeATCC 49619
2Haemophilus influenzaeL3 (clinical isolates from China)
3Moraxella catarrhalisATCC 25238
4Pseudomonas aeruginosaATCC 27853
5Klebsiella pneumoniaeA915 (clinical isolates from China)
6Staphylococcus aureusATCC 25923
7Legionella pneumophilaATCC 33152
8Streptococcus pyogenesATCC 19615
9Mycoplasma pneumonia *ATCC 29342
10Escherichia coliATCC 25922
11Bordetella pertussisATCC 9797
12Corynebacterium diphtheriaeCMCC 38106
13Mycobacterium tuberculosis complex *H37R
* Mycobacterium tuberculosis complex (20.1 ng/μL) and M. pneumoniae (15.5 ng/μL) were supplied as DNA extracts by the Chinese Center for Disease Control and Prevention.
Table 2. List of target bacteria, genes, primers, and their amplicon sizes.
Table 2. List of target bacteria, genes, primers, and their amplicon sizes.
OrganismTarget GeneNo. of Beads Coupled with “Anti-TAG” SequencesSequences (5′-3′)Working Concentration (μM)Length (bp)Detection LimitsSource
S. pneumoniaecpsA21F-TCAAACTCTCAATTCTTACTTAAT-12C-ACGCAACTGACGAGTGTGAC
R-biotin-GATCGCGACACCGAACTAAT
0.33500.1 pg[19]
M. catarrhalis16SrRNA8F-AAATAACTCACTATTTCACTTACA-12C-TTGGCTTGTGCTAAAATATC
R-biotin-GTCATCGCTATCATTCACCT
0.31400.1 pg[20]
S. aureusnuc12F-CATAATCAATTTCAACTTTCTACT-12C-GCGATTGATGGTGATACGGTT
R-biotin-AGCCAAGCCTTGACGAACTAAAGC
0.32700.1 pg[21,22]
S. pyogenesdnaseB9F-CACATCTAATACTTTATACAATTC-12C-TGATTCCAAGAGCTGTCGTG
R-biotin-TGGTGTAGCCATTAGCTGTGTT
0.3930.1 pg[23]
H. influenzaep68F-AAATAACTCACTATTTCACTTACA-12C-TTGGCGGWTACTCTGTTGCT
R-biotin-TGCAGGTTTTTCTTCACCGT
0.32960.1 pg[24]
M. pneumoniaeP112F-CATAATCAATTTCAACTTTCTACT-12C-GCCACCCTCGGGGGCAGTCAG
R-biotin-GAGTCGGGATTCCCCGCGGAGG
0.32091 pg[25,26]
Legionella spp.16SrRNA9F-CACATCTAATACTTTATACAATTC-12C-AAGATTAGCCTGCGTCCGAT
R-biotin-GTCAACTTATCGCGTTTGCT
0.36501 pg[27]
P. aeruginosaoprI14F-AATTTCTTCTCTTTCTTTCACAAT-12C-ATGAACAACGTTCTGAAATTCTCTGCT
R-biotin-CTTGCGGCTGGCTTTTTCCAG
0.32491 pg[28]
K. pneumoniaeMdh15F-TACTTCTTTACTACAATTTACAAC-12C-GCGTGGCGGTAGATCTAAGTCATA
R-biotin-TTCAGCTCCGCCACAAAGGTA
0.33640.1 pg[12,29]
Table 3. Real-time PCR assays for detection of nine respiratory pathogens.
Table 3. Real-time PCR assays for detection of nine respiratory pathogens.
OrganismGene TargetOligonucleotide/Oligo SequenceReference
S. pneumoniaelytAForward: ACGCAATCTAGCAGATGAAGCA
Reverse: TCGTGCGTTTTAATTCCAGCT
Probe: FAM-GCCGAAAACGCTTGATACAGGGAG-BHQ1
[33]
M. catarrhaliscopBForward: CGTGCGTGTTGACCGTTTTGACTTTA
Reverse: CACGCTGCCAAAAATAACTGCCAAAG
Probe: FAM-CAGCGGTAACCTAATCTATGCCACTC-BHQ1
[34]
S. aureusspaForward: TACATGTCGTTAAACCTGGTG
Reverse: TACAGTTGTACCGATGAATGG
Probe: FAM-CGCGATCCAAGAACTTGTTGTTGATAAGAAGCAACCGATCGCG-BHQ1
[35,36]
S. pyogenes16SrRNAForward: GAGAGACTAACGCATGTTAGTA
Reverse: TAGTTACCGTCACTTGGTGG
Probe: FAM-CGCGATCGCGACGATACATAGCCGACCTGGATCGCG-BHQ1
[37]
H. influenzae16SrRNAForward: TTGACATCCTAAGAAGAGCTCAGAGA
Reverse: CTTCCCTCTGTATACGCCATTGTAGC
Probe: FAM-ATGGCTGTCGTCAGCTCGTGTT-BHQ1
[34]
M. pneumoniaeP1Forward: CCAACCAAACAACAACGTTCA
Reverse: ACCTTGACTGGAGGCCGTTA
Probe: FAM-TCAATCCGAATAACGGTGACTTCTTACCACTG-BHQ1
[38]
Legionella spp.16SrRNAForward: AGGCTAATCTTAAAGCGCCAGGCC
Reverse: GCATGCTTAACACATGCAAGTCGAAC
Probe: FAM-CATATTCCTACGCGTTACTCACCCGT-BHQ1
[34]
P. aeruginosa16SrRNAForward: GACGGGTGAGTAATGCCTAGGA
Reverse: CCACTGGTGTTCCTTCCTATATCT
Probe: FAM-AGTGGGGGATCTTCGGACCTCA-BHQ1
[34]
K. pneumoniaegapAForward: TGAAGTATGACTCCACTCACGGT
Reverse: CTTCAGAAGCGGCTTTGATGGCTT
Probe: FAM-CCGGTATCTTCCTGACCGACGA-BHQ1
[34]
Table 4. Performance of the MPLT assay compared to the real-time PCR assay.
Table 4. Performance of the MPLT assay compared to the real-time PCR assay.
PathogensReal-Time PCR AssayMPLT AssayPerformance of the MPLT AssayMeasures of Agreement Kappa Values
PositiveNegativeConsistency (%)Sensitivity (%)Specificity (%)
S. pneumoniaePositive7098.887.51000.927 (p < 0.001)
Negative178
M. catarrhalisPositive00---*
Negative086
S. aureusPositive1101001001001.000 (p < 0.001)
Negative075
S. pyogenesPositive00---*
Negative086
H. influenzaePositive801001001001.000 (p < 0.001)
Negative078
M. pneumoniaePositive101001001001.000 (p < 0.001)
Negative085
Legionella spp.Positive00---*
Negative086
P. aeruginosaPositive1001001001001.000 (p < 0.001)
Negative076
K. pneumoniaePositive501001001001.000 (p < 0.001)
Negative081
* No statistics were computed because the MPLT assay and real-time PCR assay for M. catarrhalis, S. pyogenes, and Legionella spp. are constants.

Share and Cite

MDPI and ACS Style

Jiang, L.; Ren, H.; Zhou, H.; Qin, T.; Chen, Y. Simultaneous Detection of Nine Key Bacterial Respiratory Pathogens Using Luminex xTAG® Technology. Int. J. Environ. Res. Public Health 2017, 14, 223. https://doi.org/10.3390/ijerph14030223

AMA Style

Jiang L, Ren H, Zhou H, Qin T, Chen Y. Simultaneous Detection of Nine Key Bacterial Respiratory Pathogens Using Luminex xTAG® Technology. International Journal of Environmental Research and Public Health. 2017; 14(3):223. https://doi.org/10.3390/ijerph14030223

Chicago/Turabian Style

Jiang, Luxi, Hongyu Ren, Haijian Zhou, Tian Qin, and Yu Chen. 2017. "Simultaneous Detection of Nine Key Bacterial Respiratory Pathogens Using Luminex xTAG® Technology" International Journal of Environmental Research and Public Health 14, no. 3: 223. https://doi.org/10.3390/ijerph14030223

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop