Next Article in Journal
Workout Classification Using a Convolutional Neural Network in Ensemble Learning
Next Article in Special Issue
Developing a Portable Autofluorescence Detection System and Its Application in Biological Samples
Previous Article in Journal
Retention of Improved Plantar Sensation in Patients with Type II Diabetes Mellitus and Sensory Peripheral Neuropathy after One Month of Vibrating Insole Therapy: A Pilot Study
Previous Article in Special Issue
Impact of Reducing Statistically Small Population Sampling on Threshold Detection in FBG Optical Sensing
 
 
Article
Peer-Review Record

Raman Spectroscopy of Disperse Systems with Varying Particle Sizes and Correction of Signal Losses

Sensors 2024, 24(10), 3132; https://doi.org/10.3390/s24103132
by Erik Spoor 1,*, Viktoria Oerke 1, Matthias Rädle 1 and Jens-Uwe Repke 2
Reviewer 1: Anonymous
Reviewer 2: Anonymous
Reviewer 3: Anonymous
Sensors 2024, 24(10), 3132; https://doi.org/10.3390/s24103132
Submission received: 11 April 2024 / Revised: 6 May 2024 / Accepted: 13 May 2024 / Published: 15 May 2024
(This article belongs to the Special Issue Spectral Detection Technology, Sensors and Instruments)

Round 1

Reviewer 1 Report

Comments and Suggestions for Authors

The manuscript must be improved before publication.

Comments for author File: Comments.pdf

Comments on the Quality of English Language

Only minor modifications.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 2 Report

Comments and Suggestions for Authors

A correction method for Raman spectral signal loss in a variable particle size dispersion system is proposed in this manuscript. The proposed method can effectively solve the interference caused by sample particle size on Raman spectra, and it is believed that this manuscript will receive attention from Raman related research and applications. It is recommended that the manuscript be accepted after clarification of the comments.

1.The introduction should complement other relevant monitoring techniques for process analysis and highlight the advantages of Raman spectroscopy in this field. In addition, correction methods related to Raman spectroscopy should also be mentioned and completed in this section.

2.The second part should further analyse the reasons for the influence of particle size on Raman spectroscopy.

3. In the study of this method, the author selected four sample sizes. How does this method perform in correcting Raman spectroscopy for other sample sizes?

4. If the best regression equation is shown in Figure 9, is the fitted line consistent with the characteristic peaks of the sample?

5. Is the rightmost column in Table 2 the average RMSEP? This should be shown in the Table 2.

Comments on the Quality of English Language

Minor editing of English language required.

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Reviewer 3 Report

Comments and Suggestions for Authors

See attached file.

Comments for author File: Comments.pdf

Author Response

Please see the attachment.

Author Response File: Author Response.pdf

Round 2

Reviewer 1 Report

Comments and Suggestions for Authors

Modifications are adequate. The manuscript should be published

Back to TopTop