Article

Palm Temperature Differences after Static and Dynamic Load on High Bar

1
Faculty of Sport, University of Ljubljana, SI-1000 Ljubljana, Slovenia
2
Faculty of Electrical Engineering, University of Ljubljana, SI-1000 Ljubljana, Slovenia
*
Author to whom correspondence should be addressed.
Sensors 2021, 21(13), 4497; https://doi.org/10.3390/s21134497
Submission received: 25 May 2021 / Revised: 24 June 2021 / Accepted: 28 June 2021 / Published: 30 June 2021
(This article belongs to the Special Issue Thermal Imaging Sensors and Their Applications)

Abstract

Thermal imaging is used in various fields of industry and research to measure temperature and its possible differences. Since there is a lack of research and literature on palm temperatures and prevention of blisters on hands, our question was how palm temperature differs in human hands after different loads (Hang and Swing in Hang) for 30 s on a high bar. Thirty-eight students from the Faculty of Sport at the University of Ljubljana were measured with a high-quality thermal imaging camera. Palm temperatures were measured before the load was applied, immediately after and every 30 s for a period of 5 min after the load. Each hand was divided into nine different regions of interest (ROIs). Mean (XA), standard deviation (SD), maximum and minimum, and number of pixels were calculated. We found that there was no difference between the left and right hand. The temperature right after the load was applied decreased significantly for both loads and then increased above the level before the load was applied. After the static load, the temperature reached a constant higher level after 3 min. After the dynamic load, the temperatures continued to increase throughout the measurement period. Further investigation is needed to determine the time period in which the hand temperature reaches the temperature before the load is applied.
Keywords: palm temperature; thermal imaging; hang; swing in hang palm temperature; thermal imaging; hang; swing in hang

Share and Cite

MDPI and ACS Style

Šibanc, K.; Čuk, I.; Pajek, M.; Pušnik, I. Palm Temperature Differences after Static and Dynamic Load on High Bar. Sensors 2021, 21, 4497. https://doi.org/10.3390/s21134497

AMA Style

Šibanc K, Čuk I, Pajek M, Pušnik I. Palm Temperature Differences after Static and Dynamic Load on High Bar. Sensors. 2021; 21(13):4497. https://doi.org/10.3390/s21134497

Chicago/Turabian Style

Šibanc, Karmen, Ivan Čuk, Maja Pajek, and Igor Pušnik. 2021. "Palm Temperature Differences after Static and Dynamic Load on High Bar" Sensors 21, no. 13: 4497. https://doi.org/10.3390/s21134497

APA Style

Šibanc, K., Čuk, I., Pajek, M., & Pušnik, I. (2021). Palm Temperature Differences after Static and Dynamic Load on High Bar. Sensors, 21(13), 4497. https://doi.org/10.3390/s21134497