Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = tilted membrane panel

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 2462 KiB  
Article
Filterability of Polysulfone Membrane in a Tilted Panel System for Activated Sludge Filtration
by Ahmad Aliyan Alif Ismail, Sri Mulyati, Sri Aprilia, Mohd Hizami Mohd Yusoff, Normi Izati Mat Nawi, Muhammad Roil Bilad, Ahmad Fauzi Ismail and Nasrul Arahman
Water 2020, 12(12), 3533; https://doi.org/10.3390/w12123533 - 16 Dec 2020
Cited by 1 | Viewed by 2429
Abstract
Membrane bioreactors (MBRs) are established technology for treatment of domestic and industrial wastewater because they offer a small footprint and high quality of effluent, in addition to lower excess sludge. However, their widespread applications are still limited by higher expenditure for compensating for [...] Read more.
Membrane bioreactors (MBRs) are established technology for treatment of domestic and industrial wastewater because they offer a small footprint and high quality of effluent, in addition to lower excess sludge. However, their widespread applications are still limited by higher expenditure for compensating for membrane fouling. In this study, polysulfone (PSF)-based ultrafiltration membranes were developed and integrated with a tilted panel system for fouling control in activated sludge filtration. The results show an enhanced performance of filtration system thanks to the mutual advantage of the tilted panel system and the membrane properties. Both membranes showed a clear trend of higher permeability with respect to the tilted panel parameters, namely, higher tilting angle, higher aeration rate, and shorter intermittent/switching period. PSF-1 (1 wt% polyethylene glycol (PEG) additive) shows significantly better performance than PSF-3 (3 wt% PEG additive) although their mean flow pore size, structural properties, and contact angle do not differ significantly. PSF-1 shows superior filterability performance of about 45% for panel tilting angles of 20° at an aeration rate of 1.8 L·min−1, and 11% for a switching period of 1 min compared with PSF-3. The key property enhancing the performance of the PSF-1 is its narrower distribution of pore size. Overall results suggest that an optimum system could be achieved by optimizing both the filtration system and the membrane material properties. Full article
(This article belongs to the Special Issue Membrane Filtration for Water Reuse)
Show Figures

Figure 1

9 pages, 5909 KiB  
Article
Detergent and Water Recovery from Laundry Wastewater Using Tilted Panel Membrane Filtration System
by Nafiu Umar Barambu, Derrick Peter, Mohd Hizami Mohd Yusoff, Muhammad Roil Bilad, Norazanita Shamsuddin, Lisendra Marbelia, Nik Abdul Hadi Nordin and Juhana Jaafar
Membranes 2020, 10(10), 260; https://doi.org/10.3390/membranes10100260 - 27 Sep 2020
Cited by 21 | Viewed by 5544
Abstract
Increasing global concern on clean water scarcity and environmental sustainability drive invention in water reclamation technology. Laundry wastewater reclamation via membrane technology faces the challenge of membrane fouling. This paper assesses a tilting-the-filtration-panel filtration system for the treatment of real laundry wastewater filtration [...] Read more.
Increasing global concern on clean water scarcity and environmental sustainability drive invention in water reclamation technology. Laundry wastewater reclamation via membrane technology faces the challenge of membrane fouling. This paper assesses a tilting-the-filtration-panel filtration system for the treatment of real laundry wastewater filtration aimed for water and detergent reuse. Results showed that the panel tilting significantly improved fouling control and enhanced permeability due to enhanced contact of air bubbles with the membrane surface, which induced continuous detachment of foulant from the membrane surface. The combination of aeration rate and tilting angle resulted in up to 83% permeability enhancement from 109 to 221.4 ± 10.8 (L/m2·h·bar). The system also offers 32% detergent recovery. Overall findings suggest that the system offers an attractive approach for both fouling management and detergent recovery and can potentially be applied under a simple setup in which filtration can be driven by gravity/hydrostatic pressure. Full article
(This article belongs to the Special Issue Enhancing the Efficiency of Membrane Processes for Water Treatment)
Show Figures

Figure 1

12 pages, 2305 KiB  
Article
Patterned Membrane in an Energy-Efficient Tilted Panel Filtration System for Fouling Control in Activated Sludge Filtration
by Aisyah Osman, Normi Izati Mat Nawi, Shafirah Samsuri, Muhammad Roil Bilad, Norazanita Shamsuddin, Asim Laeeq Khan, Juhana Jaafar and Nik Abdul Hadi Nordin
Polymers 2020, 12(2), 432; https://doi.org/10.3390/polym12020432 - 12 Feb 2020
Cited by 21 | Viewed by 3421
Abstract
A membrane bioreactor enhances the overall biological performance of a conventional activated sludge system for wastewater treatment by producing high-quality effluent suitable for reuse. However, membrane fouling hinders the widespread application of membrane bioreactors by reducing the hydraulic performance, shortening membrane lifespan, and [...] Read more.
A membrane bioreactor enhances the overall biological performance of a conventional activated sludge system for wastewater treatment by producing high-quality effluent suitable for reuse. However, membrane fouling hinders the widespread application of membrane bioreactors by reducing the hydraulic performance, shortening membrane lifespan, and increasing the operational costs for membrane fouling management. This study assesses the combined effect of membrane surface corrugation and a tilted panel in enhancing the impact of air bubbling for membrane fouling control in activated sludge filtration, applicable for membrane bioreactors. The filterability performance of such a system was further tested under variable parameters: Filtration cycle, aeration rate, and intermittent aeration. Results show that a combination of surface corrugation and panel tilting enhances the impact of aeration and leads to 87% permeance increment. The results of the parametric study shows that the highest permeance was achieved under short filtration–relaxation cycle of 5 min, high aeration rate of 1.5 L/min, and short switching period of 2.5 min, to yield the permeances of 465 ± 18, 447 ± 2, and 369 ± 9 L/(m2h bar), respectively. The high permeances lead to higher operational flux that helps to lower the membrane area as well as energy consumption. Initial estimation of the fully aerated system yields the energy input of 0.152 kWh/m3, much lower than data from the full-scale references of <0.4 kWh/m3. Further energy savings and a lower system footprint can still be achieved by applying the two-sided panel with a switching system, which will be addressed in the future. Full article
(This article belongs to the Special Issue Polymer-Based Membrane Technology and Applications)
Show Figures

Graphical abstract

11 pages, 2901 KiB  
Article
Improved Nylon 6,6 Nanofiber Membrane in A Tilted Panel Filtration System for Fouling Control in Microalgae Harvesting
by Normi Izati Mat Nawi, Nur Syakinah Abd Halim, Leong Chew Lee, Mohd Dzul Hakim Wirzal, Muhammad Roil Bilad, Nik Abdul Hadi Nordin and Zulfan Adi Putra
Polymers 2020, 12(2), 252; https://doi.org/10.3390/polym12020252 - 21 Jan 2020
Cited by 28 | Viewed by 4485
Abstract
The competitiveness of algae as biofuel feedstock leads to the growth of membrane filtration as one of promising technologies for algae harvesting. Nanofiber membrane (NFM) was found to be efficient for microalgae harvesting via membrane filtration, but it is highly limited by its [...] Read more.
The competitiveness of algae as biofuel feedstock leads to the growth of membrane filtration as one of promising technologies for algae harvesting. Nanofiber membrane (NFM) was found to be efficient for microalgae harvesting via membrane filtration, but it is highly limited by its weak mechanical strength. The main objective of this study is to enhance the applicability of nylon 6,6 NFM for microalgae filtration by optimizing the operational parameters and applying solvent vapor treatment to improve its mechanical strength. The relaxation period and filtration cycle could be optimized to improve the hydraulic performance. For a cycle of 5 min., relaxation period of ≤2 min shows the highest steady-state permeability of 365 ± 14.14 L m−2 h−1 bar−1, while for 10 min cycle, 3 min. of relaxation period was found optimum that yields permeability of 402 ± 34.47 L m−2 h−1 bar−1. The treated nylon 6,6 NFM was also used to study the effect of aeration rate. It is confirmed that the aeration rate enhances the steady-state performance for both intermittent and continuous mode of aeration. Remarkably, intermittent aeration shows 7% better permeability than the full aeration for all tested condition, which is beneficial for reducing the total energy consumption. Full article
(This article belongs to the Special Issue Electrospun Nanofibers: Theory and Its Applications)
Show Figures

Graphical abstract

Back to TopTop