22 pages, 5839 KB  
Article
Fire Safety of Curtain Walling: Evidence-Based Critical Review and New Test Configuration Proposal for EN 1364-4
by Arritokieta Eizaguirre-Iribar, Raya Stoyanova Trifonova, Peter Ens and Xabier Olano-Azkune
Fire 2025, 8(8), 311; https://doi.org/10.3390/fire8080311 - 6 Aug 2025
Viewed by 4249
Abstract
This article focuses on the fire safety risks associated with conventional glass–aluminum façades—with a particular focus on stick and unitized curtain walling systems—providing an overview of possible fire spread mechanisms, considering the role of the curtain wall in maintaining compartmentation at the spandrel [...] Read more.
This article focuses on the fire safety risks associated with conventional glass–aluminum façades—with a particular focus on stick and unitized curtain walling systems—providing an overview of possible fire spread mechanisms, considering the role of the curtain wall in maintaining compartmentation at the spandrel zone. First, it analyzes some of the relevant requirements of different European building regulations. Then, it provides a test evidence-based critical analysis of the gaps and loopholes in the relevant fire resistance standard for partial curtain wall configurations (EN 1364-4), where the evaluation of the propagation within the façade system is not necessarily considered in the fire-resistant spandrel zone. Finally, it presents a proposal for addressing these gaps in the form of a theoretical concept for a new test configuration and additional assessment criteria. This is followed by an initial experimental analysis of the concept. The standard testing campaign showed that temperature rise in mullions can exceed 180 °C after 30 min if limiting measures are not considered in the façade design. However, this can be only detected if framing is in the non-exposed area of the sample, being part of the evaluation surface. Meanwhile, differences are detected between the results from standard and new assessment criteria in the new configuration proposed, including a more rapid temperature rise for framing elements (207 K in a second level mullion at minute 90) than for the common non-exposed assessment surface of the sample (172 K at the same time) in cases where cavities are not protected. Accordingly, the proposed configuration successfully detected vertical temperature transfer within mullions, which can remain undetected in standard EN 1364-4 tests, highlighting the potential for fire spread even in EI120-rated assemblies. Full article
Show Figures

Figure 1

19 pages, 9316 KB  
Article
Shaking Table Testing of a Low-Rise Reinforced Concrete Intermediate Moment Resisting Frame
by Sida Hussain, Hamna Shakeel, Asif Ali, Muhammad Rizwan and Naveed Ahmad
Buildings 2022, 12(12), 2104; https://doi.org/10.3390/buildings12122104 - 1 Dec 2022
Cited by 1 | Viewed by 4267
Abstract
Multi-level shaking table tests were performed on a 1:3 reduced scale two-story reinforced concrete (RC) intermediate moment resisting frame (IMRF) conforming to the requirements given in the ACI-318-19. The exterior joints lacked shear reinforcement to assess the viability of the ACI model recommended [...] Read more.
Multi-level shaking table tests were performed on a 1:3 reduced scale two-story reinforced concrete (RC) intermediate moment resisting frame (IMRF) conforming to the requirements given in the ACI-318-19. The exterior joints lacked shear reinforcement to assess the viability of the ACI model recommended for determining the design shear strength of the beam–column joint panel. One of the horizontal components of the 1994 Northridge earthquake accelerogram (090 CDMG Station 24278, Source: PEER strong motion database) was input to the frame for multi-level shaking table testing. Plastic hinges developed in beams under base input motion with a maximum acceleration equal to 0.40 g. The exterior joints incurred extensive damage under base input motion with a maximum acceleration equal to 0.70 g. The frame achieved displacement ductility and overstrength factors (determined as the ratio of the maximum resistance of the frame to the design base share force) equal to 2.40 and 2.50, respectively. This gives a response modification factor equal to 6. The satisfactory performance of the frame is attributed to the high efficiency of the beam–column joint, which was confined by spandrel beams on two faces and the high strength of the concrete. The inherent minimal confinement is sufficient to ensure satisfactory seismic behavior. The analysis confirmed overstrength equal to 1.58 for joint shear strength in comparison to the design strength determined using the ACI model. The data might serve as a reference for calibrating and validating numerical modeling techniques for performance evaluation, which are crucial in the context of performance-based engineering. Full article
(This article belongs to the Special Issue Advanced Research and Prospect of Buildings Seismic Performance)
Show Figures

Graphical abstract

16 pages, 7503 KB  
Article
Thermal Comfort Assessment of the Perimeter Zones by Using CFD Simulation
by Taesub Lim and Daeung Danny Kim
Sustainability 2022, 14(23), 15647; https://doi.org/10.3390/su142315647 - 24 Nov 2022
Cited by 3 | Viewed by 3144
Abstract
Most perimeter zones are thermally susceptible to the variation of outdoor conditions, especially due to a large amount of heat gain through glazing. To reduce heat gain, spandrel panels are generally installed in curtain walls of commercial buildings. For the present study, thermal [...] Read more.
Most perimeter zones are thermally susceptible to the variation of outdoor conditions, especially due to a large amount of heat gain through glazing. To reduce heat gain, spandrel panels are generally installed in curtain walls of commercial buildings. For the present study, thermal performance in an office located in the perimeter zone was investigated using Computational Fluid Dynamics (CFD) simulation. By varying the spandrel panel heights, thermal comfort was assessed quantitatively. The findings suggest that when the spandrel panel height was 0 m, the highest temperature was observed in all cases. As the height of the spandrel panel was increased, the temperature decreased. For thermal comfort evaluation, Predicted Mean Vote (PMV) values at 1.5 m from the floor in all cases were larger than zero. PMV values in all cases were within the range of slightly cool to warm. When the spandrel panel height was 0 m, the highest thermal sensation (warm) among the cases was observed, which may cause thermal dissatisfaction for occupants. In addition, thermal comfort was deemed satisfactory based on the criteria of ASHRAE standard 55, when the height of the spandrel panel was higher than 0.6 m. Full article
(This article belongs to the Special Issue Low Energy Architecture and Design for Thermal Comfort)
Show Figures

Figure 1

28 pages, 11772 KB  
Article
In Situ Experimental Investigation of Slim Curtain Wall Spandrel Integrated with Vacuum Insulation Panel
by Fred Edmond Boafo, Jin-Hee Kim, Jong-Gwon Ahn, Sang-Myung Kim and Jun-Tae Kim
Buildings 2022, 12(2), 199; https://doi.org/10.3390/buildings12020199 - 9 Feb 2022
Cited by 1 | Viewed by 15424
Abstract
Almost every major city’s skyline is known for high-rise iconic buildings with some level of curtain wall system (CWS) installed. Although complex, a CWS can be designed for energy efficiency by integrating insulated spandrel components in space-constrained areas, such as slabs/plenums. The main [...] Read more.
Almost every major city’s skyline is known for high-rise iconic buildings with some level of curtain wall system (CWS) installed. Although complex, a CWS can be designed for energy efficiency by integrating insulated spandrel components in space-constrained areas, such as slabs/plenums. The main aim of this study was to experimentally examine the thermal performance of an optimized curtain wall spandrel system integrated with vacuum insulation panel (VIP) as spandrel insulation. The study is based on robust experimental evaluations, augmented with appropriate numerical computations. The main study is constituted of six parts: (1) evaluation of VIP specifications and thermal properties; (2) analysis of VIP spandrel configuration, fabrication, and installation in a test building facility; (3) thermal bridge characterization of VIP spandrels; (4) monitoring and assessment of VIP durability within the spandrel cavities; (5) thermal performance analysis; and (6) assessment of related limitations and challenges, along with some further reflections. In all, 22 VIPs (each of size 600 mm2) were used. The effective thermal conductivity of VIPs ranged from 5.1–5.4 (10−3 W/mK) and the average value for initial inner pressure was approximately 4.3–5.9 mbar. Three VIP spandrel cases were fabricated and tested. The results proved that the Case 3 VIP spandrel configuration (composed of a double-layer VIP) was the most improved alternative for integrating VIPs. Full article
Show Figures

Figure 1

19 pages, 1104 KB  
Article
Introduction of an Innovative Cladding Panel System for Multi-Story Buildings
by Hathairat Maneetes and Ali M. Memari
Buildings 2014, 4(3), 418-436; https://doi.org/10.3390/buildings4030418 - 14 Aug 2014
Cited by 11 | Viewed by 7776
Abstract
An Energy Dissipating Cladding System has been developed for use in buildings designed based on the concept of damage-controlled structure in seismic design. This innovative cladding panel system is capable of functioning both as a structural brace, as well as a source of [...] Read more.
An Energy Dissipating Cladding System has been developed for use in buildings designed based on the concept of damage-controlled structure in seismic design. This innovative cladding panel system is capable of functioning both as a structural brace, as well as a source of energy dissipation, without demanding inelastic action and ductility from the basic lateral force resisting system. The structural systems of many modern buildings typically have large openings to accommodate glazing systems, and a popular type of construction uses spandrel precast cladding panels at each floor level that supports strip window systems. The present study focuses on developing spandrel type precast concrete cladding panels as supplementary energy dissipating devices that are added to the basic structural system. Through a series of analytical studies, the result of evaluating the ability of the proposed Energy Dissipating Cladding system to improve the earthquake resistance of the buildings is presented here. Full article
(This article belongs to the Special Issue Seismic-Resistant Building Design)
Show Figures