Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = size-adjustable cryo-balloon

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
13 pages, 1833 KB  
Article
Pulmonary Vein Isolation with Pulsed Field Ablation and Size-Adjustable Cryo-Balloon: A Comparative Procedural Analysis of First-Time Use
by Lyuboslav Katov, Yannick Teumer, Carlo Bothner, Wolfgang Rottbauer and Karolina Weinmann-Emhardt
J. Clin. Med. 2024, 13(11), 3113; https://doi.org/10.3390/jcm13113113 - 26 May 2024
Cited by 3 | Viewed by 2471
Abstract
Background: Pulmonary vein isolation (PVI) is the standard of care for the treatment of symptomatic atrial fibrillation (AF). Novel techniques for PVI are the thermal size-adjustable cryo-balloon (CB) system and non-thermal pulsed field ablation (PFA) system. There are currently no data available for [...] Read more.
Background: Pulmonary vein isolation (PVI) is the standard of care for the treatment of symptomatic atrial fibrillation (AF). Novel techniques for PVI are the thermal size-adjustable cryo-balloon (CB) system and non-thermal pulsed field ablation (PFA) system. There are currently no data available for a direct comparison between these two systems. Furthermore, with new techniques, it is important to ensure a high level of efficiency and safety during treatment right from initial use. Therefore, the aim of this study was to directly compare the procedural data and safety of these two new PVI techniques in first-time users. Methods: We conducted a single-center prospective study involving 100 consecutive patients with symptomatic atrial fibrillation who underwent first-time PVI using either size-adjustable CB PVI or PFA PVI from July 2023 to March 2024. Results: Acute PVI was achieved in 100% of patients in both groups. First-pass isolation (FPI) was more frequently achieved in the PFA group compared to the size-adjustable CB group. The mean procedural duration and fluoroscopy dose were significantly shorter in the PFA cohort (p < 0.001). Furthermore, a significant reduction in fluoroscopy time was observed during the learning curve within the PFA group (p = 0.023). There were no major complications in both groups. Conclusions: Both systems demonstrate good effectiveness and safety during PVI performed by first-time users. However, the PFA group exhibited a significantly shorter procedural duration. Full article
(This article belongs to the Special Issue Clinical Updates in Cardiac Electrophysiology)
Show Figures

Figure 1

9 pages, 557 KB  
Article
Pulmonary Vein Isolation with a Novel Size-Adjustable Cryo-Balloon Catheter: A Tailored Ablation Protocol
by Yannick Teumer, Franziska Hilgarth, Lyuboslav Katov, Rima Melnic, Wolfgang Rottbauer, Carlo Bothner and Karolina Weinmann
J. Clin. Med. 2024, 13(8), 2262; https://doi.org/10.3390/jcm13082262 - 13 Apr 2024
Cited by 5 | Viewed by 1744
Abstract
Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments [...] Read more.
Background: Pulmonary vein isolation (PVI) is a common therapeutic approach for symptomatic atrial fibrillation (AF). Among various techniques, cryo-balloon (CB) PVI is widely adopted, but, to date, established CB systems have had fixed balloon sizes. A novel size-adjustable CB, allowing balloon size adjustments during ablation, lacks sufficient data on optimal utilization in patient care. This study aims to systematically investigate this feature with a tailored ablation protocol. Methods: Our single-center prospective study included patients with paroxysmal or persistent atrial fibrillation undergoing first-time PVI with the size-adjustable CB from July 2023 to February 2024. Ablation was performed using the balloon size that provided better occlusion. The ablation protocol involved an initial occlusion test with the small balloon size (28 mm). If optimal occlusion (occlusion level 4) could not be achieved, an attempt with the larger balloon (31 mm) was initiated. Ablation was conducted using the balloon configuration that provided better occlusion of the pulmonary vein ostium. Results: Our prospective study includes 50 patients (median age [interquartile range, IQR]: 72 [65; 79] years, 24 [48.0%] females, and 35 [70.0%] patients with paroxysmal AF). The median procedure duration (IQR) was 77 (65; 96) minutes, and the median fluoroscopy time (IQR) was 17.7 (12.5; 22.0) min. PVI was successfully accomplished in each treated pulmonary vein (PV), with 87.4% of PVs isolated during the first freeze. The large balloon configuration was used to isolate 16.8% of PVs. Conclusions: The utilization of the size-adjustable CB, combined with the presented tailored ablation workflow, appears to facilitate effective and efficient pulmonary vein isolation. The use of a larger balloon configuration appears beneficial in isolating a significant proportion of the PVs. Full article
(This article belongs to the Special Issue Clinical Updates in Cardiac Electrophysiology)
Show Figures

Graphical abstract

10 pages, 3794 KB  
Article
Early Clinical Outcomes and Advantages of a Novel-Size Adjustable Second-Generation Cryoballoon: A Proof-of-Concept Study
by Marco Schiavone, Gaetano Fassini, Massimo Moltrasio, Benedetta Majocchi, Fabrizio Tundo, Francesca Casati and Claudio Tondo
J. Clin. Med. 2024, 13(5), 1259; https://doi.org/10.3390/jcm13051259 - 22 Feb 2024
Cited by 7 | Viewed by 1698
Abstract
(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance [...] Read more.
(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study’s limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods. Full article
(This article belongs to the Special Issue Current and Emerging Treatment Options in Atrial Fibrillation)
Show Figures

Figure 1

Back to TopTop