Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = silicon micro pre-concentrator

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 6228 KiB  
Article
The Role of APTES as a Primer for Polystyrene Coated AA2024-T3
by John Halford and Cheng-fu Chen
Micromachines 2024, 15(1), 93; https://doi.org/10.3390/mi15010093 - 31 Dec 2023
Cited by 3 | Viewed by 3397
Abstract
(3-Aminopropyl)triethoxysilane (APTES) silane possesses one terminal amine group and three ethoxy groups extending from each silicon atom, acting as a crucial interface between organic and inorganic materials. In this study, after APTES was deposited on the aluminum alloy AA2024-T3 as a primer for [...] Read more.
(3-Aminopropyl)triethoxysilane (APTES) silane possesses one terminal amine group and three ethoxy groups extending from each silicon atom, acting as a crucial interface between organic and inorganic materials. In this study, after APTES was deposited on the aluminum alloy AA2024-T3 as a primer for an optional top coating with polystyrene (PS), its role with regard to stability as a protection layer and interaction with the topcoat were studied via combinatorial experimentation. The aluminum alloy samples primed with APTES under various durations of concentrated vapor deposition (20, 40, or 60 min) with an optional post heat treatment and/or PS topcoat were comparatively characterized via electrochemical impedance spectroscopy (EIS) and surface energy. The samples top-coated with PS on an APTES layer primed for 40 min with a post heat treatment revealed excellent performance regarding corrosion impedance. A primed APTES surface with higher surface energy accounted for this higher corrosion impedance. Based on the SEM images and the surface energy calculated from the measured contact angles on the APTES-primed surfaces, four mechanisms are suggested to explain that the good protection performance of the APTES/PS coating system can be attributed to the enhanced wettability of PS on the cured APTES primer with higher surface energy. The results also suggest that, in the early stages of exposure to the corrosion solution, a thinner APTES primer (deposited for 20 min) enhances protection against corrosion, which can be attributed to the hydrolytic stability and hydrolyzation/condensation of the soaked APTES and the dissolution of the naturally formed aluminum oxide pre-existing in the bare samples. An APTES primer subjected to additional heat treatment will increase the impedance of the coating system significantly. APTES, and silanes, in general, used as adherent agents or surface modifiers, have a wide range of potential applications in micro devices, as projected in the Discussion section. Full article
(This article belongs to the Special Issue Nanomaterials for Micro/Nano Devices)
Show Figures

Figure 1

14 pages, 2882 KiB  
Article
Opto-Electronic Nose Coupled to a Silicon Micro Pre-Concentrator Device for Selective Sensing of Flavored Waters
by Sami Slimani, Etienne Bultel, Thomas Cubizolle, Cyril Herrier, Tristan Rousselle and Thierry Livache
Chemosensors 2020, 8(3), 60; https://doi.org/10.3390/chemosensors8030060 - 31 Jul 2020
Cited by 27 | Viewed by 4694
Abstract
Headspace analysis of highly humid samples remains a challenge for artificial olfaction. Based on surface plasmon resonance imaging and bio-based sensors, the NeOse Pro olfactive analyzer yields multivariate data and enhances the statistical discrimination capacity of odor patterns. However, the presence of a [...] Read more.
Headspace analysis of highly humid samples remains a challenge for artificial olfaction. Based on surface plasmon resonance imaging and bio-based sensors, the NeOse Pro olfactive analyzer yields multivariate data and enhances the statistical discrimination capacity of odor patterns. However, the presence of a high background signal, such as water vapor from aqueous samples, may deteriorate its discriminant ability. Recently, miniaturized pre-concentrators packed with hydrophobic adsorbent have been developed to improve the detection limit of gas analysis methods and to enhance their selectivity by reducing the water’s background signal. This work presents, for the first time, the coupling of a miniaturized silicon micro pre-concentration unit (µPC) to a bio-based opto-electronic nose (NeOse Pro). The results showed that the coupling of a silicon µPC with the NeOse Pro led to an improvement in the detection limit of n-nonane by at least a factor of 125. Additionally, principal component analysis (PCA) of eight different flavored waters showed an enhanced discrimination ability of the coupled set-up in highly humid conditions. Full article
(This article belongs to the Special Issue Chemosensors and Biosensors for Food Quality and Safety)
Show Figures

Figure 1

Back to TopTop