Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = segmented ring-shaped magnets

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 4717 KiB  
Article
Analysis of Effect of the Magnetization Distribution of Multi-Pole PM on SPMSM Performance Using Equivalent Magnetic Circuit Considering Dead Zone
by Jae-Hyun Kim, Kyoung-Soo Cha, Sung-Woo Hwang, Soo-Gyung Lee, Min-Ro Park, Young-Doo Yoon and Myung-Seop Lim
Energies 2021, 14(11), 3279; https://doi.org/10.3390/en14113279 - 3 Jun 2021
Cited by 1 | Viewed by 2551
Abstract
In multi-pole permanent magnets (PMs) such a ring-type PMs, as multi-poles are magnetized in one segment, the ends of each pole are weakly magnetized, which is known as the dead zone. Thus, when analyzing characteristics of the motor with multi-pole PMs, accurate results [...] Read more.
In multi-pole permanent magnets (PMs) such a ring-type PMs, as multi-poles are magnetized in one segment, the ends of each pole are weakly magnetized, which is known as the dead zone. Thus, when analyzing characteristics of the motor with multi-pole PMs, accurate results can be obtained by considering the magnetization distribution. For this reason, this paper proposed an equivalent magnetic circuit (EMC) for external-rotor surface-mounted permanent magnet synchronous motors (SPMSMs) considering the dead zone to analyze the effects of the dead zone on the characteristics of the motor. As the magnetization in the dead zone gradually decreases toward the end of the pole, the magnetization distribution is assumed to have a trapezoidal shape. To describe the magnetization distribution, each pole was divided into several elements, and the equivalent residual magnetic flux density was applied to the elements of the dead zone. Finally, the validity of the proposed EMC was verified by comparing the back electro-motive force and air-gap magnetic flux density obtained by the EMC, finite-element analysis, and test. Full article
(This article belongs to the Special Issue Analysis, Design and Optimization of Electric Machines)
Show Figures

Figure 1

20 pages, 3215 KiB  
Article
Synthesis and Self-Assembly of Poly(N-Vinylcaprolactam)-b-Poly(ε-Caprolactone) Block Copolymers via the Combination of RAFT/MADIX and Ring-Opening Polymerizations
by Rodolfo M. Moraes, Layde T. Carvalho, Gizelda M. Alves, Simone F. Medeiros, Elodie Bourgeat-Lami and Amilton M. Santos
Polymers 2020, 12(6), 1252; https://doi.org/10.3390/polym12061252 - 30 May 2020
Cited by 20 | Viewed by 4671
Abstract
Well-defined amphiphilic, biocompatible and partially biodegradable, thermo-responsive poly(N-vinylcaprolactam)-b-poly(ε-caprolactone) (PNVCL-b-PCL) block copolymers were synthesized by combining reversible addition-fragmentation chain transfer (RAFT) and ring-opening polymerizations (ROP). Poly(N-vinylcaprolactam) containing xanthate and hydroxyl end groups (X–PNVCL–OH) was first synthesized [...] Read more.
Well-defined amphiphilic, biocompatible and partially biodegradable, thermo-responsive poly(N-vinylcaprolactam)-b-poly(ε-caprolactone) (PNVCL-b-PCL) block copolymers were synthesized by combining reversible addition-fragmentation chain transfer (RAFT) and ring-opening polymerizations (ROP). Poly(N-vinylcaprolactam) containing xanthate and hydroxyl end groups (X–PNVCL–OH) was first synthesized by RAFT/macromolecular design by the interchange of xanthates (RAFT/MADIX) polymerization of NVCL mediated by a chain transfer agent containing a hydroxyl function. The xanthate-end group was then removed from PNVCL by a radical-induced process. Finally, the hydroxyl end-capped PNVCL homopolymer was used as a macroinitiator in the ROP of ε-caprolactone (ε-CL) to obtain PNVCL-b-PCL block copolymers. These (co)polymers were characterized by Size Exclusion Chromatography (SEC), Fourier-Transform Infrared spectroscopy (FTIR), Proton Nuclear Magnetic Resonance spectroscopy (1H NMR), UV–vis and Differential Scanning Calorimetry (DSC) measurements. The critical micelle concentration (CMC) of the block copolymers in aqueous solution measured by the fluorescence probe technique decreased with increasing the length of the hydrophobic block. However, dynamic light scattering (DLS) demonstrated that the size of the micelles increased with increasing the proportion of hydrophobic segments. The morphology observed by cryo-TEM demonstrated that the micelles have a pointed-oval-shape. UV–vis and DLS analyses showed that these block copolymers have a temperature-responsive behavior with a lower critical solution temperature (LCST) that could be tuned by varying the block copolymer composition. Full article
Show Figures

Graphical abstract

18 pages, 1100 KiB  
Article
Influence of Segmentation of Ring-Shaped NdFeB Magnets with Parallel Magnetization on Cylindrical Actuators
by Paulo Roberto Eckert, Evandro Claiton Goltz and Aly Ferreira Flores Filho
Sensors 2014, 14(7), 13070-13087; https://doi.org/10.3390/s140713070 - 21 Jul 2014
Cited by 5 | Viewed by 7449
Abstract
This work analyses the effects of segmentation followed by parallel magnetization of ring-shaped NdFeB permanent magnets used in slotless cylindrical linear actuators. The main purpose of the work is to evaluate the effects of that segmentation on the performance of the actuator and [...] Read more.
This work analyses the effects of segmentation followed by parallel magnetization of ring-shaped NdFeB permanent magnets used in slotless cylindrical linear actuators. The main purpose of the work is to evaluate the effects of that segmentation on the performance of the actuator and to present a general overview of the influence of parallel magnetization by varying the number of segments and comparing the results with ideal radially magnetized rings. The analysis is first performed by modelling mathematically the radial and circumferential components of magnetization for both radial and parallel magnetizations, followed by an analysis carried out by means of the 3D finite element method. Results obtained from the models are validated by measuring radial and tangential components of magnetic flux distribution in the air gap on a prototype which employs magnet rings with eight segments each with parallel magnetization. The axial force produced by the actuator was also measured and compared with the results obtained from numerical models. Although this analysis focused on a specific topology of cylindrical actuator, the observed effects on the topology could be extended to others in which surface-mounted permanent magnets are employed, including rotating electrical machines. Full article
Show Figures

Back to TopTop