Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = reliable DC-link voltage restoration

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
27 pages, 3529 KiB  
Article
Coordinated Sliding Mode and Model Predictive Control for Enhanced Fault Ride-Through in DFIG Wind Turbines
by Ahmed Muthanna Nori, Ali Kadhim Abdulabbas and Tawfiq M. Aljohani
Energies 2025, 18(15), 4017; https://doi.org/10.3390/en18154017 - 28 Jul 2025
Viewed by 205
Abstract
This work proposes an effective control technique for enhancing the stability of Doubly Fed Induction Generator-Based Wind Turbines (DFIG-WTs) connected to the grid during voltage sag and swell events, ensuring the reliable and efficient operation of wind energy systems integrated with the grid. [...] Read more.
This work proposes an effective control technique for enhancing the stability of Doubly Fed Induction Generator-Based Wind Turbines (DFIG-WTs) connected to the grid during voltage sag and swell events, ensuring the reliable and efficient operation of wind energy systems integrated with the grid. The proposed approach integrates a Dynamic Voltage Restorer (DVR) in series with a Wind Turbine Generator (WTG) output terminal to enhance the Fault Ride-Through (FRT) capability during grid disturbances. To develop a flexible control strategy for both unbalanced and balanced fault conditions, a combination of feedforward and feedback control based on a sliding mode control (SMC) for DVR converters is used. This hybrid strategy allows for precise voltage regulation, enabling the series compensator to inject the required voltage into the grid, thereby ensuring constant generator terminal voltages even during faults. The SMC enhances the system’s robustness by providing fast, reliable regulation of the injected voltage, effectively mitigating the impact of grid disturbances. To further enhance system performance, Model Predictive Control (MPC) is implemented for the Rotor-Side Converter (RSC) within the back-to-back converter (BTBC) configuration. The main advantages of the predictive control method include eliminating the need for linear controllers, coordinate transformations, or modulators for the converter. Additionally, it ensures the stable operation of the generator even under severe operating conditions, enhancing system robustness and dynamic response. To validate the proposed control strategy, a comprehensive simulation is conducted using a 2 MW DFIG-WT connected to a 120 kV grid. The simulation results demonstrate that the proposed control approach successfully limits overcurrent in the RSC, maintains electromagnetic torque and DC-link voltage within their rated values, and dynamically regulates reactive power to mitigate voltage sags and swells. This allows the WTG to continue operating at its nominal capacity, fully complying with the strict requirements of modern grid codes and ensuring reliable grid integration. Full article
Show Figures

Figure 1

27 pages, 6621 KiB  
Article
An Improved Power Management Strategy for MAS-Based Distributed Control of DC Microgrid under Communication Network Problems
by Thanh Van Nguyen and Kyeong-Hwa Kim
Sustainability 2020, 12(1), 122; https://doi.org/10.3390/su12010122 - 22 Dec 2019
Cited by 8 | Viewed by 3805
Abstract
In this paper, an improved power management strategy (PMS) for multi-agent system (MAS)-based distributed control of DC microgrid (DCMG) under communication network problems is presented in order to enhance the reliability of DCMG and to ensure the system power balance under various conditions. [...] Read more.
In this paper, an improved power management strategy (PMS) for multi-agent system (MAS)-based distributed control of DC microgrid (DCMG) under communication network problems is presented in order to enhance the reliability of DCMG and to ensure the system power balance under various conditions. To implement MAS-based distributed control, a communication network is constructed to exchange information among agents. Based on the information obtained from communication and local measurements, the decision for the local controller and communication is optimally given to guarantee the system power balance under various conditions. The operating modes of the agents can be determined locally without introducing any central controller. Simultaneously, the agents can operate in a deliberative and cooperative manner to ensure global optimization by means of the communication network. Furthermore, to prevent the system power imbalance caused by the delay in grid fault detection and communication in case of the grid fault, a DC-link voltage (DCV) restoration algorithm is proposed in this study. In addition, to avoid the conflict in the DCV control among power agents in case of the grid recovery under communication failure, a grid recovery identification algorithm is also proposed to improve the reliability of DCMG operation. In this scheme, a special current pattern is generated on the DC-link at the instant of the grid recovery by the grid agent, and other power agents identify the grid recovery by detecting this current pattern. Comprehensive simulations and experiments based on DCMG testbed have been carried out to prove the effectiveness of the PMS and the proposed control schemes under various conditions. Full article
(This article belongs to the Special Issue Integration of AC/DC Microgrids into Power Grids)
Show Figures

Figure 1

27 pages, 6504 KiB  
Article
Power Flow Control Strategy and Reliable DC-Link Voltage Restoration for DC Microgrid under Grid Fault Conditions
by Thanh Van Nguyen and Kyeong-Hwa Kim
Sustainability 2019, 11(14), 3781; https://doi.org/10.3390/su11143781 - 10 Jul 2019
Cited by 14 | Viewed by 3980
Abstract
In this paper, an effective power flow control strategy (PFCS) based on the centralized control method and a reliable DC-link voltage (DCV) restoration algorithm for a DC microgrid (DCMG) under grid fault conditions are proposed. Considering the relationship of supply-demand power and the [...] Read more.
In this paper, an effective power flow control strategy (PFCS) based on the centralized control method and a reliable DC-link voltage (DCV) restoration algorithm for a DC microgrid (DCMG) under grid fault conditions are proposed. Considering the relationship of supply-demand power and the statuses of system units, thirteen operating modes are presented to ensure the power balance in DCMG under various conditions. In the PFCS, the battery charging/discharging procedure is implemented considering the battery power limit to avoid overheating and damage. Moreover, load shedding and load reconnection algorithms are presented to maintain the system power balance, even in critical cases. To prevent the system power imbalance in DCMG caused by the delay of grid fault detection, a reliable DCV restoration algorithm is also proposed in this paper. In the proposed scheme, as soon as abnormal behavior of the DCV is detected, the battery or wind power generation system instantly enters a local emergency control mode to restore the DCV rapidly to the nominal value, regardless of the control mode assigned from the central controller. Comprehensive simulations and experiments based on the DCMG testbed are carried out to prove the effectiveness of the PFCS and the proposed DCV restoration algorithm. Full article
(This article belongs to the Special Issue Integration of AC/DC Microgrids into Power Grids)
Show Figures

Figure 1

Back to TopTop