Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = paraneural area

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2333 KiB  
Technical Note
Technical Report on the New Ultrasound Lateral Mid-Shaft Approach to the Sciatic Nerve: A Never-Ending Story
by Giuseppe Sepolvere, Mario Tedesco, Mario Cibelli, Dario Cirillo, Angelo Sparaco, Giuseppe Gagliardi, Giuseppina Costagliola, Loredana Cristiano, Valeria Rita Scialdone, Maria Rosaria Pasquariello, Fabrizio Di Zazzo, Luigi Merola, Mirco Della Valle, Daniela Arminio, Leonardo Maria Bottazzo, Marco Folliero, Giorgio Ranieri, Domenico Pietro Santonastaso and Antonio Coviello
Medicina 2025, 61(1), 100; https://doi.org/10.3390/medicina61010100 - 10 Jan 2025
Cited by 1 | Viewed by 2001
Abstract
The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this [...] Read more.
The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners. Since 2010, more than 5000 procedures have been performed by both experienced anesthesiologists and novice trainees in several hospitals. The ultrasound lateral mid-shaft technique appears to be a safe and effective method for performing a sciatic nerve block, even in obese patients with significant subcutaneous fat and unclear ultrasound images. This approach is particularly beneficial given the various anatomical variations that can occur. By targeting the mid-thigh area, the ultrasound beam accesses anatomical structures that are more superficial, improving the technique’s efficacy. Various hospital groups have been performing this technique as a routine procedure, achieving a success rate of nearly 100%. This impressive success rate exceeds that of other conventional techniques documented in the literature. Additionally, there have been significant improvements in comfort and ease for anesthetists. This method allows the anesthetic to spread around the paraneural sheath, covering the posterior femoral cutaneous nerve. Finally, it is performed in the supine position without the need to mobilize the lower limbs, ensuring patient comfort, especially in cases of fractures or lower limb injuries. Further studies are needed to confirm these results. Full article
(This article belongs to the Special Issue Update on Orthopedic Anesthesia)
Show Figures

Figure 1

11 pages, 2659 KiB  
Article
Quantitative Evaluation of the Echo Intensity of Paraneural Area and Myofascial Structure around Median Nerve in Carpal Tunnel Syndrome
by Chenglei Fan, Caterina Fede, Carmelo Pirri, Diego Guidolin, Carlo Biz, Veronica Macchi, Raffaele De Caro and Carla Stecco
Diagnostics 2020, 10(11), 914; https://doi.org/10.3390/diagnostics10110914 - 8 Nov 2020
Cited by 9 | Viewed by 3006
Abstract
The aim of this study was to investigate whether the echo intensity (EI) of the paraneural area (PA), the median nerve (MN) at the carpal tunnel, the EI of the myofascial structure (MS) around MN, the ‘PA and MN’ at the mid-forearm, and [...] Read more.
The aim of this study was to investigate whether the echo intensity (EI) of the paraneural area (PA), the median nerve (MN) at the carpal tunnel, the EI of the myofascial structure (MS) around MN, the ‘PA and MN’ at the mid-forearm, and the MN transversal displacement at both sites differs between persons with carpal tunnel syndrome (CTS) and control subjects. Methods: In total, 16 CTS patients and 16 controls, age- and gender-matched, were recruited. Cross-sectional ultrasound images of MN were obtained to evaluate the EI of the PA, the MN at carpal tunnel, the EI of MS, and the ‘PA and MN’ at the mid-forearm in a natural position, then images were taken after a whole-hand grasp movement, to evaluate MN transversal displacement. Inter-rater and intra-rater reliability in control, and differences in the EI and MN displacement between CTS and control, were analyzed. In addition, the correlations between ultrasound parameters and MN displacement were evaluated. Results: The quantitative EI of PA, MN, EI of MS, ‘PA and MN’ had high inter-rater and intra-rater reliability in the control. The EI of PA, MS and ‘PA and MN’ were significantly higher in CTS subjects (p < 0.01), whilst there was no significant difference in the EI of MN at the carpal tunnel. MN displacement was significantly decreased both at the carpal tunnel and the mid-forearm in CTS subjects (p < 0.01). In addition, there were negative correlations among the EI of PA (rs = −0.484, p = 0.004), EI of MS (rs = −0.479, p = 0.002), EI of ‘PA and MN’ (rs = −0.605, p < 0.001) and MN transversal displacement. Conclusions: The higher EI of PA and MS around MN in CTS may indicate greater fibrosis along the course of MN, reducing fascial adaptability, influencing the synergy and coordination of the MS, and increasing the shear stress between MS and MN, and it may further increase the abnormal pressure on the MN not only at the carpal tunnel, but also at the mid-forearm. These results may partly explain the role of PA and MS in CTS pathogenesis. Full article
(This article belongs to the Special Issue Skeletal Muscle Diagnostics and Managements)
Show Figures

Figure 1

Back to TopTop