Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (5)

Search Parameters:
Keywords = outdoor porcelain insulators

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
24 pages, 3839 KiB  
Article
Case Study: Optimizing Grading Ring Design for High Voltage Polymeric Insulators in Power Transmission Systems for Enhanced Electric Field and Voltage Distribution by Using a Finite Element Method
by Esraa Aziz, Fatiha Aouabed, Hossam Abdellah and Adrienn Dineva
Energies 2023, 16(13), 5235; https://doi.org/10.3390/en16135235 - 7 Jul 2023
Cited by 13 | Viewed by 3475
Abstract
This research paper aims to investigate the optimal design of grading rings for high-voltage polymeric insulators in an actual power transmission system, with a focus on improving the electrical representation of the insulator strings. One such subsidiary accessory commonly used with porcelain and [...] Read more.
This research paper aims to investigate the optimal design of grading rings for high-voltage polymeric insulators in an actual power transmission system, with a focus on improving the electrical representation of the insulator strings. One such subsidiary accessory commonly used with porcelain and polymer insulator strings is the grading ring, which is employed to improve the electric field and voltage distribution surrounding the insulator string. The efficiency of insulator strings can be enhanced by grading rings, as they facilitate a more linear potential division along the strings. The design parameters of grading rings significantly influence their performance on insulator strings. In this study, we examine the optimal design of the grading rings of high-voltage polymer insulators, since no uniform design methodology has been developed for high-voltage polymer insulators, and their optimization is currently the subject of many research studies. The electric field on an outdoor polymeric insulator is examined using finite element method (FEM) software and COMSOL Multi-Physics program. A 2D model is utilized to simulate a 220 kV polymeric insulator. The effectiveness of high-voltage polymeric insulators greatly depends on the dimensions and locations of the grading rings. Therefore, the impacts of the radius of the grading ring and that of its tube and the tube’s vertical position are thoroughly investigated, under dry and humid conditions. To achieve this objective, a search algorithm is employed to adjust the dimensions and locations of the grading ring. The optimization approach in this study is based on determining the maximum electric field across the insulator surface, while ensuring that it remains below the corona initiation level. Full article
(This article belongs to the Topic Power System Modeling and Control, 2nd Edition)
Show Figures

Figure 1

19 pages, 7207 KiB  
Article
Improvement of the Electrical Performance of Outdoor Porcelain Insulators by Utilization of a Novel Nano-TiO2 Coating for Application in Railway Electrification Systems
by Pichai Muangpratoom, Issaraporn Khonchaiyaphum and Wanwilai Vittayakorn
Energies 2023, 16(1), 561; https://doi.org/10.3390/en16010561 - 3 Jan 2023
Cited by 1 | Viewed by 3541
Abstract
The present study aimed to develop the electrical performance of outdoor insulators using a nano-TiO2 coating for railway electrification systems. The prototype design of porcelain insulators with normal coatings and using a nano-TiO2 coating is based on IEC 60815-1. The first [...] Read more.
The present study aimed to develop the electrical performance of outdoor insulators using a nano-TiO2 coating for railway electrification systems. The prototype design of porcelain insulators with normal coatings and using a nano-TiO2 coating is based on IEC 60815-1. The first test was performed to measure the low-frequency flashover AC voltage under both dry and wet conditions. In addition, the other test was conducted to measure the lightning impulse critical-flashover voltage at positive and negative polarity under dry-normal and wet-contaminated conditions. X-ray diffraction (X-RD) and Scanning electron microscopy (SEM) were used to examine the micro surface and show that the nano-TiO2 coating was adhered to the surface of the outdoor porcelain insulator and exists in an amorphous state. Additionally, it was observed and discovered that scattered nano-TiO2 strengthens the glassy matrix and creates a sturdy barrier that causes flashover voltage to be reduced under conditions of high dielectric strength. Nanostructured ceramic formulations outperform ordinary porcelain in terms of breakdown voltage strength, particularly for the insulators’ low-frequency flashover performances under dry and wet test conditions. However, a significant change in the lightning impulse critical-flashover voltage characteristics is observed and is not much better when adding the nano-TiO2 coating to the porcelain insulators. Full article
(This article belongs to the Special Issue Testing, Monitoring and Diagnostic of High Voltage Equipment)
Show Figures

Figure 1

14 pages, 11662 KiB  
Article
Application of Infrared Spectroscopy in Research on Aging of Silicone Rubber in Harsh Environment
by Zhijin Zhang, Tian Liang, Zhenglong Jiang, Xingliang Jiang, Jianlin Hu and Guohui Pang
Polymers 2022, 14(21), 4728; https://doi.org/10.3390/polym14214728 - 4 Nov 2022
Cited by 14 | Viewed by 6349
Abstract
Polymer insulators using silicone rubber materials as sheds and sheaths are widely used in power systems to replace traditional porcelain and glass insulators which are heavy, inconvenient to install, and prone to pollution flashover. However, in recent years, polymer insulators that have been [...] Read more.
Polymer insulators using silicone rubber materials as sheds and sheaths are widely used in power systems to replace traditional porcelain and glass insulators which are heavy, inconvenient to install, and prone to pollution flashover. However, in recent years, polymer insulators that have been operating in harsh outdoor environments for many years have experienced different degrees of aging. The aging degree and aging products of silicone rubber are the focus of research. Fourier transform infrared spectroscopy (FTIR) is a technical method to analyze the internal molecular bonds and functional groups of materials, and it is often used to study the aging degree and aging products of silicone rubber. In this paper, the aging characteristics of silicone rubber samples in a high altitude area, salt fog environment, and acid environment were studied by FTIR. The results showed that the silicone rubber in a harsh environment, such as strong radiation, salt fog, and acid fog was degraded to some extent, and its main chain was cut off, the degree of polymerization was reduced, and the content of hydrophobic functional groups was reduced. Infrared spectroscopy can be used to analyze the aging phenomenon of polymers. Full article
(This article belongs to the Special Issue Spectroscopy Applied to Polymers)
Show Figures

Figure 1

24 pages, 10548 KiB  
Article
Autonomous Vision-Based Primary Distribution Systems Porcelain Insulators Inspection Using UAVs
by Ehab Ur Rahman, Yihong Zhang, Sohail Ahmad, Hafiz Ishfaq Ahmad and Sayed Jobaer
Sensors 2021, 21(3), 974; https://doi.org/10.3390/s21030974 - 2 Feb 2021
Cited by 60 | Viewed by 6332
Abstract
The early detection of damaged (partially broken) outdoor insulators in primary distribution systems is of paramount importance for continuous electricity supply and public safety. Unmanned aerial vehicles (UAVs) present a safer, autonomous, and efficient way to examine the power system components without closing [...] Read more.
The early detection of damaged (partially broken) outdoor insulators in primary distribution systems is of paramount importance for continuous electricity supply and public safety. Unmanned aerial vehicles (UAVs) present a safer, autonomous, and efficient way to examine the power system components without closing the power distribution system. In this work, a novel dataset is designed by capturing real images using UAVs and manually generated images collected to overcome the data insufficiency problem. A deep Laplacian pyramid-based super-resolution network is implemented to reconstruct high-resolution training images. To improve the visibility of low-light images, a low-light image enhancement technique is used for the robust exposure correction of the training images. A different fine-tuning strategy is implemented for fine-tuning the object detection model to increase detection accuracy for the specific faulty insulators. Several flight path strategies are proposed to overcome the shuttering effect of insulators, along with providing a less complex and time- and energy-efficient approach for capturing a video stream of the power system components. The performance of different object detection models is presented for selecting the most suitable one for fine-tuning on the specific faulty insulator dataset. For the detection of damaged insulators, our proposed method achieved an F1-score of 0.81 and 0.77 on two different datasets and presents a simple and more efficient flight strategy. Our approach is based on real aerial inspection of in-service porcelain insulators by extensive evaluation of several video sequences showing robust fault recognition and diagnostic capabilities. Our approach is demonstrated on data acquired by a drone in Swat, Pakistan. Full article
(This article belongs to the Section Electronic Sensors)
Show Figures

Figure 1

19 pages, 3518 KiB  
Article
Flashover Characteristics of Silicone Rubber Sheets under Various Environmental Conditions
by Arshad, Azam Nekahi, Scott G. McMeekin and Masoud Farzaneh
Energies 2016, 9(9), 683; https://doi.org/10.3390/en9090683 - 26 Aug 2016
Cited by 29 | Viewed by 7460
Abstract
Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive [...] Read more.
Silicone rubber insulators are replacing the conventional ceramic and porcelain insulators rapidly in power transmission and distribution industry. Very limited field knowledge is available about the performance of silicone rubber insulators in polluted and contaminated environments and therefore need further investigation. A comprehensive analysis of silicone rubber sheets (intended for coating outdoor insulators) was carried out in this paper based on experimental results. The main performance parameters analyzed were arc inception voltage and flashover voltage. Dependence of these parameters on equivalent salt deposit density (ESDD), non-soluble salt deposit density (NSDD), relative humidity, ambient temperature, fog rate, dry band formation, dry band location and number of dry bands were investigated extensively. Insulator orientation and its effect on performance were also studied. The authors believe that this paper will provide a comprehensive knowledge about the flashover characteristics of silicone rubber insulators under humid, contaminated and dry band conditions. These results could be used in the selection and design of silicone rubber insulators for polluted environments. Full article
Show Figures

Figure 1

Back to TopTop