Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = nanomagnetic immunosensor

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2228 KB  
Article
Nano-Magnetic Immunosensor Based on Staphylococcus Protein A and the Amplification Effect of HRP-Conjugated Phage Antibody
by Xihui Mu, Zhaoyang Tong, Qibin Huang, Bing Liu, Zhiwei Liu, Lanqun Hao, Jinping Zhang, Chuan Gao and Fenwei Wang
Sensors 2015, 15(2), 3896-3910; https://doi.org/10.3390/s150203896 - 9 Feb 2015
Cited by 14 | Viewed by 7709
Abstract
In this research, super-paramagnetic Fe3O4 nanoparticles (magnetic particles) were coated with Staphylococcus protein A (SPA) and coupled with polyclonal antibody (pcAb) to construct magnetic capturing probes, and HRP-conjugated phage antibody was then used as specific detecting probe to design a [...] Read more.
In this research, super-paramagnetic Fe3O4 nanoparticles (magnetic particles) were coated with Staphylococcus protein A (SPA) and coupled with polyclonal antibody (pcAb) to construct magnetic capturing probes, and HRP-conjugated phage antibody was then used as specific detecting probe to design a labeled immunosensor for trace detection of Staphylococcus aureus enterotoxin B (SEB). The linear detection range of the sensor was 0.008~125 µg/L, the regression equation was Y = 0.487X + 1.2 (R = 0.996, N = 15, p < 0.0001), the limit of detection (LOD) was 0.008 µg/L, and the limit of quantification (LOQ) was 0.008 µg/L. HRP-conjugated phage antibody, SPA and magnetic particles can enhance the sensitivity 4-fold, 3-fold and 2.6-fold higher, respectively. Compared with conventional double-antibody sandwich ELISA, the detection sensitivity of the sensor was 31-fold higher resulting from the integrated amplifying effect. The immunosensor integrates the unique advantages of SPA-oriented antibody as magnetic capturing probe, HRP-conjugated phage antibody as detecting probe, magnetic separation immunoassay technique, and several other advanced techniques, so it achieves high sensitivity, specificity and interference-resistance. It is proven to be well suited for analysis of trace SEB in various environmental samples with high recovery rate and reproducibility. Full article
(This article belongs to the Special Issue Immunosensors 2014)
Show Figures

15 pages, 443 KB  
Article
An Ultrasensitive Electrochemical Immunosensor for HIV p24 Based on Fe3O4@SiO2 Nanomagnetic Probes and Nanogold Colloid-Labeled Enzyme–Antibody Copolymer as Signal Tag
by Ning Gan, Xiaowen Du, Yuting Cao, Futao Hu, Tianhua Li and Qianli Jiang
Materials 2013, 6(4), 1255-1269; https://doi.org/10.3390/ma6041255 - 25 Mar 2013
Cited by 62 | Viewed by 9165
Abstract
An ultrasensitive portable electrochemical immunosensor for human immunodeficiency virus p24 (HIV p24) antigen detection has been developed, whereby the detection sensitivity was 1000 times higher than that of the ELISA method. Firstly, a novel HRP enzyme–antibody copolymer (EV-p24 Ab2) was synthesized through an [...] Read more.
An ultrasensitive portable electrochemical immunosensor for human immunodeficiency virus p24 (HIV p24) antigen detection has been developed, whereby the detection sensitivity was 1000 times higher than that of the ELISA method. Firstly, a novel HRP enzyme–antibody copolymer (EV-p24 Ab2) was synthesized through an EnVision regent (EV, a dextrin amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of anti IgG), then incubated in the secondary antibody of p24. Secondly, the copolymer was immobilized on the gold nanocolloids (AuNPs) to fabricate a novel signal tag (AuNPs/EV-p24 Ab2). Subsequently, a sandwich-type immunoreaction would take place between the capture probe (silicon dioxide-coated magnetic Fe3O4 nanoparticles (MNPs) labeled with the primary p24 antibody (MNPs-p24 Ab1)), p24 (different concentrations) and the signal tag [AuNPs/EV-p24 Ab2)] to form the immunocomplex. Finally, the immunocomplex was absorbed on the surface of screen printed carbon electrode (SPCE) by a magnet and immersed in the o-hydroxyl phenol (HQ) and H2O2. The large amounts of HRP on the signal tag can catalyze the oxidation of HQ by H2O2, which can induce an amplified reductive current. Moreover, the capture probe could improve the accumulation ability of p24 and facilitate its separation from the substrate through the magnet. Under optimal conditions, the proposed immunoassay exhibited good sensitivity to p24 within a certain concentration range from 0.001 to 10.00 ng/mL, with a detection limit of 0.5 pg/mL (S/N = 3). The proposed method can be used for real-time and early detection of HIV-infected people. Full article
(This article belongs to the Special Issue Advances in Nanoscale Biomaterials)
Show Figures

Figure 1

Back to TopTop