Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = multilayer piezoelectric cantilever actuator

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 2331 KiB  
Article
Design of a Piezoelectrically Actuated Ultrananocrystalline Diamond (UNCD) Microcantilever Biosensor
by Villarreal Daniel, Orlando Auciello and Elida de Obaldia
Appl. Sci. 2025, 15(12), 6902; https://doi.org/10.3390/app15126902 - 19 Jun 2025
Viewed by 1697
Abstract
This work presents the theoretical design and finite element modeling of high-sensitivity microcantilevers for biosensing applications, integrating piezoelectric actuation with novel ultrananocrystalline diamond (UNCD) structures. Microcantilevers were designed based on projections to grow a multilayer metal/AlN/metal/UNCD stack on silicon substrates, optimized to detect [...] Read more.
This work presents the theoretical design and finite element modeling of high-sensitivity microcantilevers for biosensing applications, integrating piezoelectric actuation with novel ultrananocrystalline diamond (UNCD) structures. Microcantilevers were designed based on projections to grow a multilayer metal/AlN/metal/UNCD stack on silicon substrates, optimized to detect adsorption of biomolecules on the surface of exposed UNCD microcantilevers at the picogram scale. A central design criterion was to match the microcantilever’s eigenfrequency with the resonant frequency of the AlN-based piezoelectric actuator, enabling efficient dynamic excitation. The beam length was tuned to ensure a ≥2 kHz resonant frequency shift upon adsorption of 1 pg of mass distributed on the exposed surface of a UNCD-based microcantilever. Subsequently, a Gaussian distribution mass function with a variance of 5 µm was implemented to evaluate the resonant frequency shift upon mass addition at a certain point on the microcantilever where a variation from 600 Hz to 100 Hz was observed when the mass distribution center was located at the tip of the microcantilever and the piezoelectric borderline, respectively. Both frequency and time domain analyses were performed to predict the resonance behavior, oscillation amplitude, and quality factor. To ensure the reliability of the simulations, the model was first validated using experimental results reported in the literature for an AlN/nanocrystalline diamond (NCD) microcantilever. The results confirmed that the AlN/UNCD architecture exhibits higher resonant frequencies and enhanced sensitivity compared to equivalent AlN/Si structures. The findings demonstrate that using a UNCD-based microcantilever not only improves biocompatibility but also significantly enhances the mechanical performance of the biosensor, offering a robust foundation for the development of next-generation MEMS-based biochemical detection platforms. The research reported here introduces a novel design methodology that integrates piezoelectric actuation with UNCD microcantilevers through eigenfrequency matching, enabling efficient picogram-scale mass detection. Unlike previous approaches, it combines actuator and cantilever optimization within a unified finite element framework, validated against experimental data published in the literature for similar piezo-actuated sensors using materials with inferior biocompatibility compared with the novel UNCD. The dual-domain simulation strategy offers accurate prediction of key performance metrics, establishing a robust and scalable path for next-generation MEMS biosensors. Full article
Show Figures

Figure 1

14 pages, 1460 KiB  
Article
Theoretical Modeling of Piezoelectric Cantilever MEMS Loudspeakers
by Wei Liu, Jie Huang, Yong Shen and Jiazheng Cheng
Appl. Sci. 2021, 11(14), 6323; https://doi.org/10.3390/app11146323 - 8 Jul 2021
Cited by 6 | Viewed by 3130
Abstract
Piezoelectric microelectromechanical system (MEMS) loudspeakers have received extensive attention in recent years. In particular, the piezoelectric cantilever MEMS loudspeaker, which uses multilayer piezoelectric cantilever actuators (MPCAs), has attracted attention because of its small size, low cost, ease of manufacture, and desirable piston movement. [...] Read more.
Piezoelectric microelectromechanical system (MEMS) loudspeakers have received extensive attention in recent years. In particular, the piezoelectric cantilever MEMS loudspeaker, which uses multilayer piezoelectric cantilever actuators (MPCAs), has attracted attention because of its small size, low cost, ease of manufacture, and desirable piston movement. However, owing to the complex driving principles of MPCAs, no adequately efficient and appropriate method currently exists that can be used to analyze and predict the performance of piezoelectric cantilever MEMS loudspeakers. In this study, the equivalent circuit method (ECM) is adopted to theoretically model piezoelectric cantilever MEMS loudspeakers, and an ECM model with a special MPCA transformer for electromechanical conversion is proposed. With the proposed ECM model, the performance characteristics of piezoelectric cantilever MEMS loudspeakers, such as the displacement and sound pressure response, can be calculated efficiently and conveniently. To verify the accuracy of the ECM model, the finite element method is adopted for simulation, and the simulated results are compared with those of the ECM models. A satisfactory agreement was found, which verifies the accuracy of the proposed ECM model. Full article
(This article belongs to the Special Issue Sound Field Control)
Show Figures

Figure 1

Back to TopTop