Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (11)

Search Parameters:
Keywords = imaging photoplethysmogram

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 3074 KiB  
Article
Electrophysiological Characteristics of Inhibitive Control for Adults with Different Physiological or Psychological Obesity
by Jiaqi Guo, Xiaofang Wan, Junwei Lian, Hanqing Ma, Debo Dong, Yong Liu and Jia Zhao
Nutrients 2024, 16(9), 1252; https://doi.org/10.3390/nu16091252 - 23 Apr 2024
Cited by 3 | Viewed by 1707
Abstract
Individuals exhibiting high scores on the fatness subscale of the negative-physical-self scale (NPSS-F) are characterized by heightened preoccupation with body fat accompanied by negative body image perceptions, often leading to excessive dieting behaviors. This demographic constitutes a considerable segment of the populace in [...] Read more.
Individuals exhibiting high scores on the fatness subscale of the negative-physical-self scale (NPSS-F) are characterized by heightened preoccupation with body fat accompanied by negative body image perceptions, often leading to excessive dieting behaviors. This demographic constitutes a considerable segment of the populace in China, even among those who are not obese. Nonetheless, scant empirical inquiries have delved into the behavioral and neurophysiological profiles of individuals possessing a healthy body mass index (BMI) alongside elevated NPSS-F scores. This study employed an experimental paradigm integrating go/no-go and one-back tasks to assess inhibitory control and working memory capacities concerning food-related stimuli across three adult cohorts: those with normal weight and low NPSS-F scores, those with normal weight and high NPSS-F scores, and individuals classified as obese. Experimental stimuli comprised high- and low-caloric-food pictures with concurrent electroencephalogram (EEG) and photoplethysmogram (PPG) recordings. Individuals characterized by high NPSS-F scores and normal weight exhibited distinctive electrophysiological responses compared to the other two cohorts, evident in event-related potential (ERP) components, theta and alpha band oscillations, and heart rate variability (HRV) patterns. In essence, the findings underscore alterations in electrophysiological reactivity among individuals possessing high NPSS-F scores and a healthy BMI in the context of food-related stimuli, underscoring the necessity for increased attention to this demographic alongside individuals affected by obesity. Full article
(This article belongs to the Special Issue Healthy Eating and Determinants of Food Choice)
Show Figures

Figure 1

32 pages, 5164 KiB  
Article
Biometric-Based Human Identification Using Ensemble-Based Technique and ECG Signals
by Anfal Ahmed Aleidan, Qaisar Abbas, Yassine Daadaa, Imran Qureshi, Ganeshkumar Perumal, Mostafa E. A. Ibrahim and Alaa E. S. Ahmed
Appl. Sci. 2023, 13(16), 9454; https://doi.org/10.3390/app13169454 - 21 Aug 2023
Cited by 13 | Viewed by 3428
Abstract
User authentication has become necessary in different life domains. Traditional authentication methods like personal information numbers (PINs), password ID cards, and tokens are vulnerable to attacks. For secure authentication, methods like biometrics have been developed in the past. Biometric information is hard to [...] Read more.
User authentication has become necessary in different life domains. Traditional authentication methods like personal information numbers (PINs), password ID cards, and tokens are vulnerable to attacks. For secure authentication, methods like biometrics have been developed in the past. Biometric information is hard to lose, forget, duplicate, or share because it is a part of the human body. Many authentication methods focused on electrocardiogram (ECG) signals have achieved great success. In this paper, we have developed cardiac biometrics for human identification using a deep learning (DL) approach. Cardiac biometric systems rely on cardiac signals that are captured using the electrocardiogram (ECG), photoplethysmogram (PPG), and phonocardiogram (PCG). This study utilizes the ECG as a biometric modality because ECG signals are a superior choice for accurate, secure, and reliable biometric-based human identification systems, setting them apart from PPG and PCG approaches. To get better performance in terms of accuracy and computational time, we have developed an ensemble approach based on VGG16 pre-trained transfer learning (TL) and Long Short-Term Memory (LSTM) architectures to optimize features. To develop this authentication system, we have fine-tuned this ensemble network. In the first phase, we preprocessed the ECG biosignal to remove noise. In the second phase, we converted the 1-D ECG signals into a 2-D spectrogram image using a transformation phase. Next, the feature extraction step is performed on spectrogram images using the proposed ensemble DL technique, and finally, those features are identified by the boosting machine learning classifier to recognize humans. Several experiments were performed on the selected dataset, and on average, the proposed system achieved 98.7% accuracy, 98.01% precision, 97.1% recall, and 0.98 AUC. In this paper, we have compared the developed approach with state-of-the-art biometric authentication systems. The experimental results demonstrate that our proposed system outperformed the human recognition competition. Full article
(This article belongs to the Special Issue Recent Advances in Biomedical Image and Signal Processing)
Show Figures

Figure 1

17 pages, 2917 KiB  
Article
Heart Rate Estimation from Facial Image Sequences of a Dual-Modality RGB-NIR Camera
by Wen-Nung Lie, Dao-Quang Le, Chun-Yu Lai and Yu-Shin Fang
Sensors 2023, 23(13), 6079; https://doi.org/10.3390/s23136079 - 1 Jul 2023
Cited by 9 | Viewed by 4175
Abstract
This paper presents an RGB-NIR (Near Infrared) dual-modality technique to analyze the remote photoplethysmogram (rPPG) signal and hence estimate the heart rate (in beats per minute), from a facial image sequence. Our main innovative contribution is the introduction of several denoising techniques such [...] Read more.
This paper presents an RGB-NIR (Near Infrared) dual-modality technique to analyze the remote photoplethysmogram (rPPG) signal and hence estimate the heart rate (in beats per minute), from a facial image sequence. Our main innovative contribution is the introduction of several denoising techniques such as Modified Amplitude Selective Filtering (MASF), Wavelet Decomposition (WD), and Robust Principal Component Analysis (RPCA), which take advantage of RGB and NIR band characteristics to uncover the rPPG signals effectively through this Independent Component Analysis (ICA)-based algorithm. Two datasets, of which one is the public PURE dataset and the other is the CCUHR dataset built with a popular Intel RealSense D435 RGB-D camera, are adopted in our experiments. Facial video sequences in the two datasets are diverse in nature with normal brightness, under-illumination (i.e., dark), and facial motion. Experimental results show that the proposed method has reached competitive accuracies among the state-of-the-art methods even at a shorter video length. For example, our method achieves MAE = 4.45 bpm (beats per minute) and RMSE = 6.18 bpm for RGB-NIR videos of 10 and 20 s in the CCUHR dataset and MAE = 3.24 bpm and RMSE = 4.1 bpm for RGB videos of 60-s in the PURE dataset. Our system has the advantages of accessible and affordable hardware, simple and fast computations, and wide realistic applications. Full article
(This article belongs to the Special Issue Intelligent Health Monitoring Systems Based on Sensor Processing)
Show Figures

Figure 1

10 pages, 1216 KiB  
Communication
GRGB rPPG: An Efficient Low-Complexity Remote Photoplethysmography-Based Algorithm for Heart Rate Estimation
by Fridolin Haugg, Mohamed Elgendi and Carlo Menon
Bioengineering 2023, 10(2), 243; https://doi.org/10.3390/bioengineering10020243 - 12 Feb 2023
Cited by 21 | Viewed by 10358
Abstract
Remote photoplethysmography (rPPG) is a promising contactless technology that uses videos of faces to extract health parameters, such as heart rate. Several methods for transforming red, green, and blue (RGB) video signals into rPPG signals have been introduced in the existing literature. The [...] Read more.
Remote photoplethysmography (rPPG) is a promising contactless technology that uses videos of faces to extract health parameters, such as heart rate. Several methods for transforming red, green, and blue (RGB) video signals into rPPG signals have been introduced in the existing literature. The RGB signals represent variations in the reflected luminance from the skin surface of an individual over a given period of time. These methods attempt to find the best combination of color channels to reconstruct an rPPG signal. Usually, rPPG methods use a combination of prepossessed color channels to convert the three RGB signals to one rPPG signal that is most influenced by blood volume changes. This study examined simple yet effective methods to convert the RGB to rPPG, relying only on RGB signals without applying complex mathematical models or machine learning algorithms. A new method, GRGB rPPG, was proposed that outperformed most machine-learning-based rPPG methods and was robust to indoor lighting and participant motion. Moreover, the proposed method estimated the heart rate better than well-established rPPG methods. This paper also discusses the results and provides recommendations for further research. Full article
Show Figures

Figure 1

12 pages, 3826 KiB  
Article
Effectiveness of Remote PPG Construction Methods: A Preliminary Analysis
by Fridolin Haugg, Mohamed Elgendi and Carlo Menon
Bioengineering 2022, 9(10), 485; https://doi.org/10.3390/bioengineering9100485 - 20 Sep 2022
Cited by 20 | Viewed by 6761
Abstract
The contactless recording of a photoplethysmography (PPG) signal with a Red-Green-Blue (RGB) camera is known as remote photoplethysmography (rPPG). Studies have reported on the positive impact of using this technique, particularly in heart rate estimation, which has led to increased research on this [...] Read more.
The contactless recording of a photoplethysmography (PPG) signal with a Red-Green-Blue (RGB) camera is known as remote photoplethysmography (rPPG). Studies have reported on the positive impact of using this technique, particularly in heart rate estimation, which has led to increased research on this topic among scientists. Therefore, converting from RGB signals to constructing an rPPG signal is an important step. Eight rPPG methods (plant-orthogonal-to-skin (POS), local group invariance (LGI), the chrominance-based method (CHROM), orthogonal matrix image transformation (OMIT), GREEN, independent component analysis (ICA), principal component analysis (PCA), and blood volume pulse (PBV) methods) were assessed using dynamic time warping, power spectrum analysis, and Pearson’s correlation coefficient, with different activities (at rest, during exercising in the gym, during talking, and while head rotating) and four regions of interest (ROI): the forehead, the left cheek, the right cheek, and a combination of all three ROIs. The best performing rPPG methods in all categories were the POS, LGI, and OMI methods; each performed well in all activities. Recommendations for future work are provided. Full article
Show Figures

Figure 1

12 pages, 1686 KiB  
Communication
Estimating Resting HRV during fMRI: A Comparison between Laboratory and Scanner Environment
by Andy Schumann, Stefanie Suttkus and Karl-Jürgen Bär
Sensors 2021, 21(22), 7663; https://doi.org/10.3390/s21227663 - 18 Nov 2021
Cited by 6 | Viewed by 3034
Abstract
Heart rate variability (HRV) is regularly assessed in neuroimaging studies as an indicator of autonomic, emotional or cognitive processes. In this study, we investigated the influence of a loud and cramped environment during magnetic resonance imaging (MRI) on resting HRV measures. We compared [...] Read more.
Heart rate variability (HRV) is regularly assessed in neuroimaging studies as an indicator of autonomic, emotional or cognitive processes. In this study, we investigated the influence of a loud and cramped environment during magnetic resonance imaging (MRI) on resting HRV measures. We compared recordings during functional MRI sessions with recordings in our autonomic laboratory (LAB) in 101 healthy subjects. In the LAB, we recorded an electrocardiogram (ECG) and a photoplethysmogram (PPG) over 15 min. During resting state functional MRI, we acquired a PPG for 15 min. We assessed anxiety levels before the scanning in each subject. In 27 participants, we performed follow-up sessions to investigate a possible effect of habituation. We found a high intra-class correlation ranging between 0.775 and 0.996, indicating high consistency across conditions. We observed no systematic influence of the MRI environment on any HRV index when PPG signals were analyzed. However, SDNN and RMSSD were significantly higher when extracted from the PPG compared to the ECG. Although we found a significant correlation of anxiety and the decrease in HRV from LAB to MRI, a familiarization session did not change the HRV outcome. Our results suggest that psychological factors are less influential on the HRV outcome during MRI than the methodological choice of the cardiac signal to analyze. Full article
(This article belongs to the Special Issue Neurophysiological Monitoring)
Show Figures

Figure 1

27 pages, 2460 KiB  
Article
Assessment of Non-Invasive Blood Pressure Prediction from PPG and rPPG Signals Using Deep Learning
by Fabian Schrumpf, Patrick Frenzel, Christoph Aust, Georg Osterhoff and Mirco Fuchs
Sensors 2021, 21(18), 6022; https://doi.org/10.3390/s21186022 - 8 Sep 2021
Cited by 98 | Viewed by 18964
Abstract
Exploiting photoplethysmography signals (PPG) for non-invasive blood pressure (BP) measurement is interesting for various reasons. First, PPG can easily be measured using fingerclip sensors. Second, camera based approaches allow to derive remote PPG (rPPG) signals similar to PPG and therefore provide the opportunity [...] Read more.
Exploiting photoplethysmography signals (PPG) for non-invasive blood pressure (BP) measurement is interesting for various reasons. First, PPG can easily be measured using fingerclip sensors. Second, camera based approaches allow to derive remote PPG (rPPG) signals similar to PPG and therefore provide the opportunity for non-invasive measurements of BP. Various methods relying on machine learning techniques have recently been published. Performances are often reported as the mean average error (MAE) on the data which is problematic. This work aims to analyze the PPG- and rPPG based BP prediction error with respect to the underlying data distribution. First, we train established neural network (NN) architectures and derive an appropriate parameterization of input segments drawn from continuous PPG signals. Second, we use this parameterization to train NNs with a larger PPG dataset and carry out a systematic evaluation of the predicted blood pressure. The analysis revealed a strong systematic increase of the prediction error towards less frequent BP values across NN architectures. Moreover, we tested different train/test set split configurations which underpin the importance of a careful subject-aware dataset assignment to prevent overly optimistic results. Third, we use transfer learning to train the NNs for rPPG based BP prediction. The resulting performances are similar to the PPG-only case. Finally, we apply different personalization techniques and retrain our NNs with subject-specific data for both the PPG-only and rPPG case. Whilst the particular technique is less important, personalization reduces the prediction errors significantly. Full article
(This article belongs to the Special Issue Contactless Sensors for Healthcare)
Show Figures

Figure 1

18 pages, 3098 KiB  
Article
Machine Learning-Based Pulse Wave Analysis for Early Detection of Abdominal Aortic Aneurysms Using In Silico Pulse Waves
by Tianqi Wang, Weiwei Jin, Fuyou Liang and Jordi Alastruey
Symmetry 2021, 13(5), 804; https://doi.org/10.3390/sym13050804 - 5 May 2021
Cited by 24 | Viewed by 6182
Abstract
An abdominal aortic aneurysm (AAA) is usually asymptomatic until rupture, which is associated with extremely high mortality. Consequently, the early detection of AAAs is of paramount importance in reducing mortality; however, most AAAs are detected by medical imaging only incidentally. The aim of [...] Read more.
An abdominal aortic aneurysm (AAA) is usually asymptomatic until rupture, which is associated with extremely high mortality. Consequently, the early detection of AAAs is of paramount importance in reducing mortality; however, most AAAs are detected by medical imaging only incidentally. The aim of this study was to investigate the feasibility of machine learning-based pulse wave (PW) analysis for the early detection of AAAs using a database of in silico PWs. PWs in the large systemic arteries were simulated using one-dimensional blood flow modelling. A database of in silico PWs representative of subjects (aged 55, 65 and 75 years) with different AAA sizes was created by varying the AAA-related parameters with major impacts on PWs—identified by parameter sensitivity analysis—in an existing database of in silico PWs representative of subjects without AAAs. Then, a machine learning architecture for AAA detection was trained and tested using the new in silico PW database. The parameter sensitivity analysis revealed that the AAA maximum diameter and stiffness of the large systemic arteries were the dominant AAA-related biophysical properties considerably influencing the PWs. However, AAA detection by PW indexes was compromised by other non-AAA related cardiovascular parameters. The proposed machine learning model produced a sensitivity of 86.8 % and a specificity of 86.3 % in early detection of AAA from the photoplethysmogram PW signal measured in the digital artery with added random noise. The number of false positive and negative results increased with increasing age and decreasing AAA size, respectively. These findings suggest that machine learning-based PW analysis is a promising approach for AAA screening using PW signals acquired by wearable devices. Full article
(This article belongs to the Special Issue Biofluids in Medicine: Models, Computational Methods and Applications)
Show Figures

Figure 1

11 pages, 2140 KiB  
Article
Recurrence Plot and Machine Learning for Signal Quality Assessment of Photoplethysmogram in Mobile Environment
by Donggeun Roh and Hangsik Shin
Sensors 2021, 21(6), 2188; https://doi.org/10.3390/s21062188 - 20 Mar 2021
Cited by 34 | Viewed by 4796
Abstract
The purpose of this study was to develop a machine learning model that could accurately evaluate the quality of a photoplethysmogram based on the shape of the photoplethysmogram and the phase relevance in a pulsatile waveform without requiring complicated pre-processing. Photoplethysmograms were recorded [...] Read more.
The purpose of this study was to develop a machine learning model that could accurately evaluate the quality of a photoplethysmogram based on the shape of the photoplethysmogram and the phase relevance in a pulsatile waveform without requiring complicated pre-processing. Photoplethysmograms were recorded for 76 participants (5 min for each participant). All recorded photoplethysmograms were segmented for each beat to obtain a total of 49,561 pulsatile segments. These pulsatile segments were manually labeled as ‘good’ and ‘poor’ classes and converted to a two-dimensional phase space trajectory image using a recurrence plot. The classification model was implemented using a convolutional neural network with a two-layer structure. As a result, the proposed model correctly classified 48,827 segments out of 49,561 segments and misclassified 734 segments, showing a balanced accuracy of 0.975. Sensitivity, specificity, and positive predictive values of the developed model for the test dataset with a ‘poor’ class classification were 0.964, 0.987, and 0.848, respectively. The area under the curve was 0.994. The convolutional neural network model with recurrence plot as input proposed in this study can be used for signal quality assessment as a generalized model with high accuracy through data expansion. It has an advantage in that it does not require complicated pre-processing or a feature detection process. Full article
(This article belongs to the Special Issue Mobile Healthcare Based on IoT)
Show Figures

Figure 1

19 pages, 1031 KiB  
Article
Stress Classification Using Photoplethysmogram-Based Spatial and Frequency Domain Images
by Sami Elzeiny and Marwa Qaraqe
Sensors 2020, 20(18), 5312; https://doi.org/10.3390/s20185312 - 17 Sep 2020
Cited by 13 | Viewed by 4391
Abstract
Stress is subjective and is manifested differently from one person to another. Thus, the performance of generic classification models that classify stress status is crude. Building a person-specific model leads to a reliable classification, but it requires the collection of new data to [...] Read more.
Stress is subjective and is manifested differently from one person to another. Thus, the performance of generic classification models that classify stress status is crude. Building a person-specific model leads to a reliable classification, but it requires the collection of new data to train a new model for every individual and needs periodic upgrades because stress is dynamic. In this paper, a new binary classification (called stressed and non-stressed) approach is proposed for a subject’s stress state in which the inter-beat intervals extracted from a photoplethysomogram (PPG) were transferred to spatial images and then to frequency domain images according to the number of consecutive. Then, the convolution neural network (CNN) was used to train and validate the classification accuracy of the person’s stress state. Three types of classification models were built: person-specific models, generic classification models, and calibrated-generic classification models. The average classification accuracies achieved by person-specific models using spatial images and frequency domain images were 99.9%, 100%, and 99.8%, and 99.68%, 98.97%, and 96.4% for the training, validation, and test, respectively. By combining 20% of the samples collected from test subjects into the training data, the calibrated generic models’ accuracy was improved and outperformed the generic performance across both the spatial and frequency domain images. The average classification accuracy of 99.6%, 99.9%, and 88.1%, and 99.2%, 97.4%, and 87.6% were obtained for the training set, validation set, and test set, respectively, using the calibrated generic classification-based method for the series of inter-beat interval (IBI) spatial and frequency domain images. The main contribution of this study is the use of the frequency domain images that are generated from the spatial domain images of the IBI extracted from the PPG signal to classify the stress state of the individual by building person-specific models and calibrated generic models. Full article
(This article belongs to the Special Issue Sensing and Data Analysis Techniques for Intelligent Healthcare)
Show Figures

Figure 1

18 pages, 5595 KiB  
Article
Detection of Stress Levels from Biosignals Measured in Virtual Reality Environments Using a Kernel-Based Extreme Learning Machine
by Dongrae Cho, Jinsil Ham, Jooyoung Oh, Jeanho Park, Sayup Kim, Nak-Kyu Lee and Boreom Lee
Sensors 2017, 17(10), 2435; https://doi.org/10.3390/s17102435 - 24 Oct 2017
Cited by 122 | Viewed by 10285
Abstract
Virtual reality (VR) is a computer technique that creates an artificial environment composed of realistic images, sounds, and other sensations. Many researchers have used VR devices to generate various stimuli, and have utilized them to perform experiments or to provide treatment. In this [...] Read more.
Virtual reality (VR) is a computer technique that creates an artificial environment composed of realistic images, sounds, and other sensations. Many researchers have used VR devices to generate various stimuli, and have utilized them to perform experiments or to provide treatment. In this study, the participants performed mental tasks using a VR device while physiological signals were measured: a photoplethysmogram (PPG), electrodermal activity (EDA), and skin temperature (SKT). In general, stress is an important factor that can influence the autonomic nervous system (ANS). Heart-rate variability (HRV) is known to be related to ANS activity, so we used an HRV derived from the PPG peak interval. In addition, the peak characteristics of the skin conductance (SC) from EDA and SKT variation can also reflect ANS activity; we utilized them as well. Then, we applied a kernel-based extreme-learning machine (K-ELM) to correctly classify the stress levels induced by the VR task to reflect five different levels of stress situations: baseline, mild stress, moderate stress, severe stress, and recovery. Twelve healthy subjects voluntarily participated in the study. Three physiological signals were measured in stress environment generated by VR device. As a result, the average classification accuracy was over 95% using K-ELM and the integrated feature (IT = HRV + SC + SKT). In addition, the proposed algorithm can embed a microcontroller chip since K-ELM algorithm have very short computation time. Therefore, a compact wearable device classifying stress levels using physiological signals can be developed. Full article
Show Figures

Figure 1

Back to TopTop