Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = hydro-viscous clutch

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
28 pages, 12978 KiB  
Article
A Novel Double Closed Loop Control of Temperature and Rotational Speed for Integrated Multi-Parameter Hydro-Viscous Speed Control System (HSCS)
by Kai Zhao, Yuan Wang, Shoukun Wang, Feiyue Gao, Xiang Feng, Hu Shen, Lin Zhang, Liang Wang, Bin Yu and Kaixian Ba
Machines 2024, 12(6), 394; https://doi.org/10.3390/machines12060394 - 10 Jun 2024
Viewed by 1430
Abstract
Hydro-viscous clutch has already become an inevitable choice for special vehicle transmission in the present and future. As a nonlinear system with a large hysteresis loop, its speed control performance is affected by input rotational speed, lubricating oil temperature, lubrication pressure, and other [...] Read more.
Hydro-viscous clutch has already become an inevitable choice for special vehicle transmission in the present and future. As a nonlinear system with a large hysteresis loop, its speed control performance is affected by input rotational speed, lubricating oil temperature, lubrication pressure, and other factors. The traditional control method cannot adjust the temperature and rotational speed, which will lead to problems of narrow speed range, poor rotational speed stability, and large dynamic load impact. In order to solve the above problems, this paper studies the control method of an integrated multi-parameter hydro-viscous speed control system (HSCS) in a controlled environment. Through the mechanism analysis of the law of HSCS, the influence law of speed and temperature during the system operation is found. The temperature closed loop based on model predictive control (MPC) is introduced to control the rotational speed, and then the traditional PID control results are compensated according to the speed closed loop. Next, a novel double closed loop control method of temperature and rotational speed for HSCS is formed. Finally, the simulating verification is carried out. Compared with the traditional control method, the design method in this paper can adjust the control parameters according to the temperature of the lubricating oil and the input rotational speed and effectively expand the domain of HSCS and the speed control stability. The effective transmission ratio is extended to 0.2~0.8, and the hydro-viscous torque and speed fluctuation under the engine rotational speed fluctuation are reduced by more than 30%. The novel control method of HSCS designed in this paper can effectively improve the influence of input rotational speed and lubricating oil temperature on the speed control performance of HSCS and can be widely used in nonlinear HSCS such as hydro-viscous clutch. Full article
(This article belongs to the Special Issue Control and Mechanical System Engineering)
Show Figures

Figure 1

15 pages, 3732 KiB  
Article
Control Performance Improvement of Hydro-Viscous Clutch Based on Fuzzy-PID Controller
by Xiangping Liao, Shuai Yang, Dong Hu, Guofang Gong and Xiongbin Peng
Energies 2021, 14(24), 8282; https://doi.org/10.3390/en14248282 - 9 Dec 2021
Cited by 4 | Viewed by 2420
Abstract
As a rotational speed controller, a hydro-viscous clutch (HVC) is usually used in the constant pressure water supply system to maintain the needed water pressure constant. However, when the hydro-viscous clutch is working, it often suffers from the problem of output rotational speed [...] Read more.
As a rotational speed controller, a hydro-viscous clutch (HVC) is usually used in the constant pressure water supply system to maintain the needed water pressure constant. However, when the hydro-viscous clutch is working, it often suffers from the problem of output rotational speed fluctuation since the spool of proportional relief valve can easily get stuck. Consequently, water pressure will fluctuate too. A special pump control system of HVC was proposed based on the Fuzzy-PID controller for the purpose of reducing the fluctuation rate. The MATLAB simulation was carried out according to the mathematical model and the results show that the Fuzzy-PID control strategy is superior to traditional PID control. The corresponding experiment was performed and the result indicate that through applying the Fuzzy-PID controller based pump control system, the rotational output speed fluctuation of HVC can be inhibited from ±60π to ±6π rad/min, and the water pressure fluctuation is dropped from ±0.1 to ±0.002 MPa. Full article
(This article belongs to the Special Issue New Challenges in Electrohydraulic Control System and Energy Saving)
Show Figures

Figure 1

14 pages, 4290 KiB  
Article
Analysis and Revision of Torque Formula for Hydro-viscous Clutch
by Xiangping Liao, Shuai Yang, Dong Hu and Guofang Gong
Energies 2021, 14(23), 7884; https://doi.org/10.3390/en14237884 - 24 Nov 2021
Cited by 5 | Viewed by 2792
Abstract
Hydro-viscous clutch is a speed-regulating device for heavy fans and water pumps. It has important engineering significance in the fields of soft-start for rotating machinery. More and more attention has been paid to its torque and control characteristics. This paper is focused on [...] Read more.
Hydro-viscous clutch is a speed-regulating device for heavy fans and water pumps. It has important engineering significance in the fields of soft-start for rotating machinery. More and more attention has been paid to its torque and control characteristics. This paper is focused on the torque formula for hydro-viscous clutch (HVC), assuming that multi-friction plates distribute ununiformly with different oil film thickness. A mathematical model of friction plates was constructed, then the distribution formula of the oil film thickness was obtained. A new expression was presented using a modified factor. Parameters such as pressure, viscous torque, and oil film thickness were obtained. The results show that each clearance of friction plates is not the same and the distribution of oil film thickness is influenced by pressing force, groove depth, angular ratio of groove/non-groove, and static friction force. To verify the proposed expression, relevant experiments were carried out on an HVC with multi-friction plates, and the experimental results indicate that the new expression is more accurate compared to the original one. Full article
(This article belongs to the Special Issue New Challenges in Electrohydraulic Control System and Energy Saving)
Show Figures

Figure 1

Back to TopTop