Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = hollow coaxial cable

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
16 pages, 4139 KiB  
Article
An All-Solid-State Coaxial Structural Battery Using Sodium-Based Electrolyte
by Federico Danzi, Pedro Ponces Camanho and Maria Helena Braga
Molecules 2021, 26(17), 5226; https://doi.org/10.3390/molecules26175226 - 28 Aug 2021
Cited by 23 | Viewed by 5282
Abstract
The transition to a sustainable society is paramount and requires the electrification of vehicles, the grid, industry, data banks, wearables, and IoT. Here, we show an all-solid-state structural battery where a Na+-based ferroelectric glass electrolyte is combined with metallic electrodes/current collectors [...] Read more.
The transition to a sustainable society is paramount and requires the electrification of vehicles, the grid, industry, data banks, wearables, and IoT. Here, we show an all-solid-state structural battery where a Na+-based ferroelectric glass electrolyte is combined with metallic electrodes/current collectors (no traditional cathode present at fabrication) and thin-ply carbon-fiber laminates to obtain a coaxial multifunctional beam. This new concept aims to optimize the volume of any hollow beam-like structure by integrating an electrochemical system capable of both harvesting thermal and storing electrical energy while improving its mechanical performance. The coaxial cell is a coaxial cable where the dielectric is ferroelectric. The electrochemical results demonstrated the capability of performing three-minute charges to one-day discharges (70 cycles) and long-lasting discharges (>40 days at 1 mA) showing an energy density of 56.2 Wh·L−1 and specific energy of 38.0 Wh·kg−1, including the whole volume and weight of the structural cell. This is the highest specific energy among safe structural cells, while no Na+-based structural cells were found in the literature. The mechanical tests, instead, highlighted the coaxial cell capabilities to withstand severe inelastic deformation without compromising its functionalities, while increasing the flexural strength of the hosting structure. Moreover, the absence of alkali metals and liquid electrolytes together with its enhanced thermal properties makes this coaxial structural battery a valid and safe alternative as an energy reservoir for all the applications where traditional lithium-ion batteries are not suitable. Full article
(This article belongs to the Special Issue Dielectrics in Materials and Devices)
Show Figures

Figure 1

14 pages, 7270 KiB  
Article
Displacement and Strain Measurement up to 1000 °C Using a Hollow Coaxial Cable Fabry-Perot Resonator
by Chen Zhu, Yizheng Chen, Yiyang Zhuang and Jie Huang
Sensors 2018, 18(5), 1304; https://doi.org/10.3390/s18051304 - 24 Apr 2018
Cited by 32 | Viewed by 5460
Abstract
We present a hollow coaxial cable Fabry-Perot resonator for displacement and strain measurement up to 1000 °C. By employing a novel homemade hollow coaxial cable made of stainless steel as a sensing platform, the high-temperature tolerance of the sensor is dramatically improved. A [...] Read more.
We present a hollow coaxial cable Fabry-Perot resonator for displacement and strain measurement up to 1000 °C. By employing a novel homemade hollow coaxial cable made of stainless steel as a sensing platform, the high-temperature tolerance of the sensor is dramatically improved. A Fabry-Perot resonator is implemented on this hollow coaxial cable by introducing two highly-reflective reflectors along the cable. Based on a nested structure design, the external displacement and strain can be directly correlated to the cavity length of the resonator. By tracking the shift of the amplitude reflection spectrum of the microwave resonator, the applied displacement and strain can be determined. The displacement measurement experiment showed that the sensor could function properly up to 1000 °C. The sensor was also employed to measure the thermal strain of a steel plate during the heating process. The stability of the novel sensor was also investigated. The developed sensing platform and sensing configurations are robust, cost-effective, easy to manufacture, and can be flexibly designed for many other measurement applications in harsh high-temperature environments. Full article
(This article belongs to the Special Issue Resonator Sensors 2018)
Show Figures

Figure 1

Back to TopTop