Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = corneo-scleral contact lens

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 1950 KiB  
Article
Pilot Study Evaluating the Early Clinical Outcomes Obtained with a Novel, Customized, Multifocal Corneo-Scleral Contact Lens for Presbyopia Correction
by Laura Barberán-Bernardos, Daniel Soriano Salcedo, Sergio Díaz-Gómez and David P. Piñero
Life 2025, 15(5), 700; https://doi.org/10.3390/life15050700 - 25 Apr 2025
Viewed by 591
Abstract
Background: The objective was to preliminarily evaluate the short-term clinical outcomes obtained in presbyopic patients with a novel, multifocal, customized corneo-scleral contact lens (CSCL). Methods: A total of 11 presbyopic subjects (age 45–80 years, corrected-distance visual acuity ≤ 0.1 LogMAR, near addition ≥ [...] Read more.
Background: The objective was to preliminarily evaluate the short-term clinical outcomes obtained in presbyopic patients with a novel, multifocal, customized corneo-scleral contact lens (CSCL). Methods: A total of 11 presbyopic subjects (age 45–80 years, corrected-distance visual acuity ≤ 0.1 LogMAR, near addition ≥ +1.00 D) were recruited and fitted with a multifocal corneo-scleral contact lens in this pilot study. Pre-fitting evaluations included stereopsis, contrast sensitivity (CS), and ocular aberrometry, with follow-up assessments conducted at 20 min and 1-month post-fitting. The defocus curve was also measured to assess visual performance across varying distances. Results: Twenty-two eyes from 11 participants (53.9 ± 4.7 years, 10 female) were included in this study. Significant changes were observed post-fitting for primary and secondary spherical aberration, coma, and stereopsis (p ≤ 0.033). No significant changes in Strehl ratio and total root mean square were detected (p ≥ 0.182). Binocular contrast sensitivity was better with spectacles than with the fitted CSCL at all frequencies (p ≤ 0.048), but the change in monocular did not reach statistical significance for 18 cycles per degree (p = 0.109). All patients and 90.9% of patients achieved a visual acuity of 0.0 LogMAR or better at distance and at intermediate, respectively, and 91.8% achieved 0.3 LogMAR or better for near vision. Conclusions: The customized CSCL evaluated provided functional recovery of visual quality across distances, with acceptable reductions of CS and stereopsis that are comparable to those reported for other multifocal contact lenses. Full article
(This article belongs to the Special Issue Vision Science and Optometry)
Show Figures

Figure 1

12 pages, 1172 KiB  
Article
Anterior Scleral Regional Variation between Asian and Caucasian Populations
by Alejandra Consejo, Richard Wu and Ahmed Abass
J. Clin. Med. 2020, 9(11), 3419; https://doi.org/10.3390/jcm9113419 - 25 Oct 2020
Cited by 10 | Viewed by 2267
Abstract
Purpose: To evaluate the anterior scleral shape regional differences between Asian and Caucasian populations. Methods: The study included 250 Asian eyes and 235 Caucasian eyes from participants aged 22 to 67 years (38.5 ± 7.6). Three-dimensional (3D) corneo-scleral maps were acquired using a [...] Read more.
Purpose: To evaluate the anterior scleral shape regional differences between Asian and Caucasian populations. Methods: The study included 250 Asian eyes and 235 Caucasian eyes from participants aged 22 to 67 years (38.5 ± 7.6). Three-dimensional (3D) corneo-scleral maps were acquired using a corneo-scleral topographer (Eye Surface Profiler, Eaglet Eye BV) and used to calculate sagittal height. For each 3D map, the sclera (maximum diameter of 18 mm) and cornea were separated at the limbus using an automated technique. Advanced data processing steps were applied to ensure levelled artefact-free datasets to build an average scleral shape map for each population. Results: Statistically, Asian and Caucasian sclerae are significantly different from each other in sagittal height (overall sclera, p = 0.001). The largest difference in sagittal height between groups was found in the inferior-temporal region (271 ± 203 µm, p = 0.03), whereas the smallest difference was found in the superior-temporal region (84 ± 105 µm, p = 0.17). The difference in sagittal height between Caucasian and Asian sclera increases with the distance from the limbus. Conclusions: Asian anterior sclera was found to be less elevated than Caucasian anterior sclera. However, the nasal area of the sclera is less elevated than the temporal area, independently of race. Gaining knowledge in race-related scleral topography differences could assist contact lens manufacturers in the process of lens design and practitioners during the process of contact lens fitting. Full article
(This article belongs to the Section Ophthalmology)
Show Figures

Figure 1

Back to TopTop