Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = anti-immunocomplex peptide

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 2424 KiB  
Article
Identification and Application of Two Promising Peptide Ligands for the Immunodetection of Imidacloprid Residue
by Tianyang You, Yuan Ding, Yue Huang, Yang Lu, Minghua Wang and Xiude Hua
Foods 2022, 11(20), 3163; https://doi.org/10.3390/foods11203163 - 11 Oct 2022
Cited by 7 | Viewed by 1940
Abstract
As the most widely used neonicotinoid insecticide, it is of great significance to explore the immunoreagents and immunoassays for imidacloprid (IMI) residue. In immunoassays, specific peptide ligands, such as peptidomimetic and anti-immunocomplex peptides, are regarded as promising substitutes for chemical haptens. In the [...] Read more.
As the most widely used neonicotinoid insecticide, it is of great significance to explore the immunoreagents and immunoassays for imidacloprid (IMI) residue. In immunoassays, specific peptide ligands, such as peptidomimetic and anti-immunocomplex peptides, are regarded as promising substitutes for chemical haptens. In the present work, we identified thirty sequences of peptidomimetics and two sequences of anti-immunocomplex peptides for IMI from three phage pVIII display cyclic peptide libraries, in which the anti-immunocomplex peptides are the first reported noncompetitive reagents for IMI. The peptidomimetic 1-9-H and anti-immunocomplex peptide 2-1-H that showed the best sensitivity were utilized to develop competitive and noncompetitive phage enzyme-linked immunosorbent assays (P-ELISAs), with a half inhibition concentration of 0.55 ng/mL for competitive P-ELISA and a half-saturation concentration of 0.35 ng/mL for noncompetitive P-ELISA. The anti-immunocomplex peptide was demonstrated to greatly improve the specificity compared with competitive P-ELISA. In addition, the accuracy of proposed P-ELISAs was confirmed by recovery analysis and HPLC verification in agricultural and environmental samples. These results show that the peptide ligands identified from phage display library can replace chemical haptens in the immunoassays of IMI with the satisfactory performance. Full article
(This article belongs to the Special Issue Application of Immunoassay Technology in Food Inspection)
Show Figures

Figure 1

16 pages, 2463 KiB  
Article
The Role of IgG Fc Region N-Glycosylation in the Pathomechanism of Rheumatoid Arthritis
by Balázs Gyebrovszki, András Ács, Dániel Szabó, Felícia Auer, Soma Novozánszki, Bernadette Rojkovich, Anna Magyar, Ferenc Hudecz, Károly Vékey, László Drahos and Gabriella Sármay
Int. J. Mol. Sci. 2022, 23(10), 5828; https://doi.org/10.3390/ijms23105828 - 23 May 2022
Cited by 13 | Viewed by 3518
Abstract
Anti-citrullinated protein antibodies (ACPAs) are involved in the pathogenesis of rheumatoid arthritis. N-glycosylation pattern of ACPA-IgG and healthy IgG Fc differs. The aim of this study is to determine the relative sialylation and galactosylation level of ACPAs and control IgG to assess their [...] Read more.
Anti-citrullinated protein antibodies (ACPAs) are involved in the pathogenesis of rheumatoid arthritis. N-glycosylation pattern of ACPA-IgG and healthy IgG Fc differs. The aim of this study is to determine the relative sialylation and galactosylation level of ACPAs and control IgG to assess their capability of inducing TNFα production, and furthermore, to analyze the correlations between the composition of Fc glycans and inflammatory markers in RA. We isolated IgG from sera of healthy volunteers and RA patients, and purified ACPAs on a citrulline-peptide column. Immunocomplexes (IC) were formed by adding an F(ab)2 fragment of anti-human IgG. U937 cells were used to monitor the binding of IC to FcγR and to trigger TNFα release determined by ELISA. To analyze glycan profiles, control IgG and ACPA-IgG were digested with trypsin and the glycosylation patterns of glycopeptides were analyzed by determining site-specific N-glycosylation using nano-UHPLC-MS/MS. We found that both sialylation and galactosylation levels of ACPA-IgG negatively correlate with inflammation-related parameters such as CRP, ESR, and RF. Functional assays show that dimerized ACPA-IgG significantly enhances TNFα release in an FcγRI-dependent manner, whereas healthy IgG does not. TNFα production inversely correlates with the relative intensities of the G0 glycoform, which lacks galactose and terminal sialic acid moieties. Full article
(This article belongs to the Special Issue Highlights in Pathophysiology of the Musculoskeletal System)
Show Figures

Figure 1

15 pages, 1345 KiB  
Article
A Pencil-Lead Immunosensor for the Rapid Electrochemical Measurement of Anti-Diphtheria Toxin Antibodies
by Wilson A. Ameku, Vanessa N. Ataide, Eric T. Costa, Larissa R. Gomes, Paloma Napoleão-Pêgo, David William Provance, Thiago R. L. C. Paixão, Maiara O. Salles and Salvatore Giovanni De-Simone
Biosensors 2021, 11(12), 489; https://doi.org/10.3390/bios11120489 - 30 Nov 2021
Cited by 4 | Viewed by 4044
Abstract
Diphtheria is a vaccine-preventable disease, yet immunization can wane over time to non-protective levels. We have developed a low-cost, miniaturized electroanalytical biosensor to quantify anti-diphtheria toxin (DTx) immunoglobulin G (anti-DTx IgG) antibody to minimize the risk for localized outbreaks. Two epitopes specific to [...] Read more.
Diphtheria is a vaccine-preventable disease, yet immunization can wane over time to non-protective levels. We have developed a low-cost, miniaturized electroanalytical biosensor to quantify anti-diphtheria toxin (DTx) immunoglobulin G (anti-DTx IgG) antibody to minimize the risk for localized outbreaks. Two epitopes specific to DTx and recognized by antibodies generated post-vaccination were selected to create a bi-epitope peptide, biEP, by synthesizing the epitopes in tandem. The biEP peptide was conjugated to the surface of a pencil-lead electrode (PLE) integrated into a portable electrode holder. Captured anti-DTx IgG was measured by square wave voltammetry from the generation of hydroquinone (HQ) from the resulting immunocomplex. The performance of the biEP reagent presented high selectivity and specificity for DTx. Under the optimized working conditions, a logarithmic calibration curve showed good linearity over the concentration range of 10−5–10−1 IU mL−1 and achieved a limit of detection of 5 × 10−6 IU mL−1. The final device proved suitable for interrogating the immunity level against DTx in actual serum samples. Results showed good agreement with those obtained from a commercial enzyme-linked immunosorbent assay. In addition, the flexibility for conjugating other capture molecules to PLEs suggests that this technology could be easily adapted to the diagnoses of other pathogens. Full article
(This article belongs to the Section Biosensors and Healthcare)
Show Figures

Graphical abstract

19 pages, 1633 KiB  
Article
Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin
by Sultana Akter, Markus Vehniäinen, Harri T. Kankaanpää and Urpo Lamminmäki
Microorganisms 2017, 5(3), 58; https://doi.org/10.3390/microorganisms5030058 - 12 Sep 2017
Cited by 13 | Viewed by 5271
Abstract
Nodularin (NOD) is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water [...] Read more.
Nodularin (NOD) is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A phage display technique was utilized to interrogate a synthetic antibody phage library for binders recognizing NOD bound to an anti-ADDA (3-Amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4(E),6(E)-dienoic acid) monoclonal antibody (Mab). One of the obtained immunocomplex binders, designated SA32C11, showed very high specificity towards nodularin-R (NOD-R) over to the tested 10 different microcystins (microcystin-LR, -dmLR, -RR, -dmRR, -YR, -LY, -LF, -LW, -LA, -WR). It was expressed in Escherichia coli as a single chain antibody fragment (scFv) fusion protein and used to establish a time-resolved fluorometry-based assay in combination with the anti-ADDA Mab. The detection limit (blank + 3SD) of the immunoassay, with a total assay time of 1 h 10 min, is 0.03 µg/L of NOD-R. This represents the most sensitive immunoassay method for the specific detection of NOD reported so far. The assay was tested for its performance to detect NOD using spiked (0.1 to 3 µg/L of NOD-R) water samples including brackish sea and coastal water and the recovery ranged from 79 to 127%. Furthermore, a panel of environmental samples, including water from different sources, fish and other marine tissue specimens, were analyzed for NOD using the assay. The assay has potential as a rapid screening tool for the analysis of a large number of water samples for the presence of NOD. It can also find applications in the analysis of the bioaccumulation of NOD in marine organisms and in the food chain. Full article
(This article belongs to the Special Issue Toxic Cyanobacteria and Toxic Dinoflagellates)
Show Figures

Figure 1

Back to TopTop