In Situ Monitoring and Assessment of Ischemic Skin Flap by High-Frequency Ultrasound and Quantitative Parameters
by Da-Ming Huang and Shyh-Hau Wang
Sensors 2024, 24(2), 363; https://doi.org/10.3390/s24020363 - 7 Jan 2024
Cited by 2 | Viewed by 1410
Abstract
Skin flap surgery is a critical procedure for treating severe skin injury in which post-surgery lesions must well monitored and cared for noninvasively. In the present study, attempts using high-frequency ultrasound imaging, quantitative parameters, and statistical analysis were made to extensively assess variations [...] Read more.
Skin flap surgery is a critical procedure for treating severe skin injury in which post-surgery lesions must well monitored and cared for noninvasively. In the present study, attempts using high-frequency ultrasound imaging, quantitative parameters, and statistical analysis were made to extensively assess variations in the skin flap. Experiments were arranged by incising the dorsal skin of rats to create a skin flap using the chamber model. Measurements, including photographs, 30 MHz ultrasound B-mode images, skin thickness, echogenicity, Nakagami statistics, and histological analysis of post-surgery skin flap, were performed. Photograph results showed that color variations in different parts of the skin flap may readily correspond to ischemic states of local tissues. Compared to post-surgery skin flap on day 7, both integrated backscatter (IB) and Nakagami parameter (m) of the distal part of tissues were increased, and those of the skin thickness were decreased. Overall, relative skin thickness, IB, and m of the distal part of post-surgery skin flap varied from 100 to 67%, −66 to −61 dB, and 0.48 to 0.36, respectively. These results demonstrate that this modality and quantitative parameters can be feasibly applied for long-term and in situ assessment of skin flap tissues. Full article
(This article belongs to the Section Biosensors)
Show Figures

Figure 1

20 pages, 9170 KiB  
Article
Window-Modulated Compounding Nakagami Parameter Ratio Approach for Assessing Muscle Perfusion with Contrast-Enhanced Ultrasound Imaging
by Huang-Chen Lin and Shyh-Hau Wang
Sensors 2020, 20(12), 3584; https://doi.org/10.3390/s20123584 - 24 Jun 2020
Cited by 4 | Viewed by 2858
Abstract
The assessment of microvascular perfusion is essential for the diagnosis of a specific muscle disease. In comparison with the current available medical modalities, the contrast-enhanced ultrasound imaging is the simplest and fastest means for probing the tissue perfusion. Specifically, the perfusion parameters estimated [...] Read more.
The assessment of microvascular perfusion is essential for the diagnosis of a specific muscle disease. In comparison with the current available medical modalities, the contrast-enhanced ultrasound imaging is the simplest and fastest means for probing the tissue perfusion. Specifically, the perfusion parameters estimated from the ultrasound time-intensity curve (TIC) and statistics-based time–Nakagami parameter curve (TNC) approaches were found able to quantify the perfusion. However, due to insufficient tolerance on tissue clutters and subresolvable effects, these approaches remain short of reproducibility and robustness. Consequently, the window-modulated compounding (WMC) Nakagami parameter ratio imaging was proposed to alleviate these effects, by taking the ratio of WMC Nakagami parameters corresponding to the incidence of two different acoustic pressures from an employed transducer. The time–Nakagami parameter ratio curve (TNRC) approach was also developed to estimate perfusion parameters. Measurements for the assessment of muscle perfusion were performed from the flow phantom and animal subjects administrated with a bolus of ultrasound contrast agents. The TNRC approach demonstrated better sensitivity and tolerance of tissue clutters than those of TIC and TNC. The fusion image with the WMC Nakagami parameter ratio and B-mode images indicated that both the tissue structures and perfusion properties of ultrasound contrast agents may be better discerned. Full article